TN-SM24TAT4XB-FUNCTION-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayString,MacAddress,TEXTUAL-CONVENTION,RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE,OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF ifIndex FROM IF-MIB enterprises,MODULE-IDENTITY,OBJECT-TYPE,NOTIFICATION-TYPE,Unsigned32,Integer32,Counter32,Counter64,IpAddress FROM SNMPv2-SMI -- PortList FROM Q-BRIDGE-MIB InetAddress, InetAddressType FROM INET-ADDRESS-MIB OwnerString FROM RMON-MIB sysObjectID FROM SNMPv2-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB; -- MacAddress FROM BRIDGE-MIB; transition MODULE-IDENTITY LAST-UPDATED "202112300217Z" ORGANIZATION "Corp." CONTACT-INFO " " DESCRIPTION "Managed PoE+ Switch, 24-port 10/100/1000Base-T PoE Plus + (4) 1G/10G SFP+ slots" REVISION "202112300217Z" DESCRIPTION " " REVISION "201405300000Z" DESCRIPTION "Rev 1.0 Initial version." ::= { enterprises 868 } -- ======================================================================================================================= OperState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Oper state." SYNTAX INTEGER { up ( 1 ) , down ( 2 ) } AdminMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The Admin state - default: disable(0)." SYNTAX INTEGER { disable(0), enable(1) } AdminMode2 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The Admin state - default: disable(0)." SYNTAX INTEGER { disable(0), enable(1), notSupported(2) } ActivateCmd ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Used to activate commands. default: noAction(0). " SYNTAX INTEGER { noAction ( 0 ), activate ( 1 ) } KeyType ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The key type specifying the key generated for frames received on the port. 0 : Normal, 1 : Double Tag, 2 : IP Address, 3 : MAC and IP Address." SYNTAX INTEGER { normal ( 0 ), doubleTag ( 1 ), ipAddr ( 2 ), macAndIpAddr ( 3 ) } FrameRate ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The values for frame rate" SYNTAX INTEGER { threeHundredFramesPerSec (0), oneHundredFramesPerSec (1), tenFramesPerSec (2), oneFramePerSec (3), sixFramesPerMin (4), oneFramePerMin (5), sixFramesPerHour (6) } DayOfWeek ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Used to set the days of the week." SYNTAX INTEGER {mon(1),tue(2),wed(3),thur(4), fri(5),sat(6),sun(7) } Month ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Used to set the month." SYNTAX INTEGER {jan(1),feb(2),march(3),april(4), may(5),june(6),july(7),aug(8), sept(9),oct(10),nov(11),dec(12)} switch OBJECT IDENTIFIER ::= { transition 2 } sm24tat4xbProductLevel1 OBJECT IDENTIFIER ::= { switch 77 } sm24tat4xbProductId OBJECT IDENTIFIER ::= { sm24tat4xbProductLevel1 2 } sm24tat4xbSystem OBJECT IDENTIFIER ::= { sm24tat4xbProductId 1 } sm24tat4xbSystemInformation OBJECT IDENTIFIER ::= { sm24tat4xbSystem 1 } sm24tat4xbSystemInfo OBJECT IDENTIFIER ::= { sm24tat4xbSystemInformation 1 } sm24tat4xbSystemInfoModelName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 2 } sm24tat4xbSystemInfoSystemDescript OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 3 } sm24tat4xbSystemInfoLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 4 } sm24tat4xbSystemInfoContact OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 5 } sm24tat4xbSystemInfoSystemName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 6 } sm24tat4xbSystemInfoSystemDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 7 } sm24tat4xbSystemInfoSystemUptime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 8 } sm24tat4xbSystemInfoBootloaderVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 9 } sm24tat4xbSystemInfoFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 10 } sm24tat4xbSystemInfoHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 11 } sm24tat4xbSystemInfoMechanicalVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 12 } sm24tat4xbSystemInfoSeriesNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 13 } sm24tat4xbSystemInfoHostMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 14 } -- sm24tat4xbSystemInfoMemory OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbSystemInfo 15 } -- sm24tat4xbSystemInfoFlash OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbSystemInfo 16 } sm24tat4xbSystemInfoFanSpeed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Fan Speed" ::= { sm24tat4xbSystemInfo 17 } -- sm24tat4xbSystemInfoPowerStatus OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbSystemInfo 19 } -- sm24tat4xbSystemInfoPowers OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbSystemInfo 20 } -- sm24tat4xbSystemInfoTemperatureStatus OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbSystemInfo 21 } sm24tat4xbSystemInfoTemperature1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 22 } sm24tat4xbSystemInfoTemperature2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 23 } sm24tat4xbSystemInfoCPULoad OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "CPU Utilization." ::= { sm24tat4xbSystemInfo 24 } sm24tat4xbSystemInfoPoEFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSystemInfo 32 } -- sm24tat4xbSystemInfoProductionDate OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Production Date." -- ::= { sm24tat4xbSystemInfo 33 } sm24tat4xbSystemTimeConf OBJECT IDENTIFIER ::= { sm24tat4xbSystem 2 } -- sm24tat4xbSystemNTP OBJECT IDENTIFIER ::= { sm24tat4xbSystemTimeConf 1 } sm24tat4xbSystemTime OBJECT IDENTIFIER ::= { sm24tat4xbSystemTimeConf 2 } sm24tat4xbSystemTimeZone OBJECT IDENTIFIER ::= { sm24tat4xbSystemTime 1 } sm24tat4xbSystemTimeDaylightSaving OBJECT IDENTIFIER ::= { sm24tat4xbSystemTime 2 } sm24tat4xbSystemTimeConfiguration OBJECT IDENTIFIER ::= { sm24tat4xbSystemTime 3 } -- -- ======================================================================================================================= -- Objects in the sm24tat4xbSystemNTP Group -- ======================================================================================================================= -- sm24tat4xbSystemNTPMode OBJECT-TYPE -- SYNTAX INTEGER {useLocal(0),useNTP(1)} -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The system NTP Mode. -- useLocal(0) : Use Local Settings, -- useNTP(1) : Use NTP Server." -- DEFVAL { useLocal } -- ::= { sm24tat4xbSystemNTP 1 } -- -- sm24tat4xbSystemNTPServer1 OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Get/Set the NTP Time Server1. -- You can use the IP address or domain name." -- ::= { sm24tat4xbSystemNTP 2 } -- -- sm24tat4xbSystemNTPServer2 OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Get/Set the NTP Time Server2. -- You can use the IP address or domain name." -- ::= { sm24tat4xbSystemNTP 3 } -- -- sm24tat4xbSystemNTPServer3 OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Get/Set the NTP Time Server3. -- You can use the IP address or domain name." -- ::= { sm24tat4xbSystemNTP 4 } -- -- sm24tat4xbSystemNTPServer4 OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Get/Set the NTP Time Server4. -- You can use the IP address or domain name." -- ::= { sm24tat4xbSystemNTP 5 } -- -- sm24tat4xbSystemNTPServer5 OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Get/Set the NTP Time Server5. -- You can use the IP address or domain name." -- ::= { sm24tat4xbSystemNTP 6 } -- -- ======================================================================================================================= -- Objects in the sm24tat4xbSystemTime Group -- ======================================================================================================================= --sm24tat4xbSystemTimeZone sm24tat4xbSystemTimeZoneConf OBJECT-TYPE SYNTAX Integer32(-7200..7201) MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the NTP Time Zone. The value range is between -7200 and 7201 (minutes). 0 : None. -7200 : (GMT-12:00). -6600 : (GMT-11:00). -6000 : (GMT-10:00). -5400 : (GMT-09:00). -4800 : (GMT-08:00)Pacific Time. -4801 : (GMT-08:00)Tijuana, Baja California. -4200 : (GMT-07:00)Arizona. -4201 : (GMT-07:00)Chihuahua, La Paz, Mazatlan - New. -4202 : (GMT-07:00)Chihuahua, La Paz, Mazatlan - Old. -4203 : (GMT-07:00)Mountain Time. -3600 : (GMT-06:00)Central America. -3601 : (GMT-06:00)Central Time. -3602 : (GMT-06:00)Guadalajara, Mexico City, Monterrey - New. -3603 : (GMT-06:00)Guadalajara, Mexico City, Monterrey - Old. -3604 : (GMT-06:00)Saskatchewan. -3000 : (GMT-05:00)Bogota, Lima, Quito, Rio Branco. -3001 : (GMT-05:00)Eastern Time. -3002 : (GMT-05:00)Indiana. -2700 : (GMT-04:30). -2400 : (GMT-04:00)Atlantic Time. -2401 : (GMT-04:00)La Paz. -2402 : (GMT-04:00)Manaus. -2403 : (GMT-04:00)Santiago. -2100 : (GMT-03:30). -1800 : (GMT-03:00)Brasilia. -1801 : (GMT-03:00)Buenos Aires. -1802 : (GMT-03:00)Georgetown. -1803 : (GMT-03:00)Greenland. -1804 : (GMT-03:00)Montevideo. -1805 : (GMT-02:00). -600 : (GMT-01:00)Azores. -601 : (GMT-01:00)Cape Verde Is. 1 : (GMT) Casablanca. 2 : (GMT) Greenwich Mean Time. 3 : (GMT) Monrovia, Reykjavik. 600 : (GMT+01:00) Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna. 601 : (GMT+01:00) Belgrade, Bratislava, Budapest, Ljubljana, Prague. 602 : (GMT+01:00) Brussels, Copenhagen, Madrid, Paris. 603 : (GMT+01:00) Sarajevo, Skopje, Warsaw, Zagreb. 604 : (GMT+01:00) West Central Africa. 1200 : (GMT+02:00) Amman. 1201 : (GMT+02:00) Athens, Bucharest, Istanbul. 1202 : (GMT+02:00) Beirut. 1203 : (GMT+02:00) Cairo. 1204 : (GMT+02:00) Harare, Pretoria. 1205 : (GMT+02:00) Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius. 1206 : (GMT+02:00) Jerusalem. 1207 : (GMT+02:00) Minsk. 1208 : (GMT+02:00) Windhoek. 1800 : (GMT+03:00) Baghdad. 1801 : (GMT+03:00) Kuwait, Riyadh. 1802 : (GMT+03:00) Moscow, St. Petersburg, Volgograd. 1803 : (GMT+03:00) Nairobi. 1804 : (GMT+03:00) Tbilisi. 2100 : (GMT+03:30) Tehran. 2400 : (GMT+04:00) Abu Dhabi, Muscat. 2401 : (GMT+04:00) Baku. 2402 : (GMT+04:00) Caucasus Standard Time. 2403 : (GMT+04:00) Port Louis. 2404 : (GMT+04:00) Yerevan. 2700 : (GMT+04:30) Kabul. 3000 : (GMT+05:00) Ekaterinburg. 3001 : (GMT+05:00) Islamabad, Karachi. 3002 : (GMT+05:00) Tashkent. 3300 : (GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi. 3301 : (GMT+05:30) Sri Jayawardenepura. 3455 : (GMT+05:45) Kathmandu. 3600 : (GMT+06:00) Almaty, Novosibirsk. 3601 : (GMT+06:00) Astana, Dhaka. 3600 : (GMT+06:30) Yangon (Rangoon). 4200 : (GMT+07:00) Bangkok, Hanoi, Jakarta. 4201 : (GMT+07:00) Krasnoyarsk. 4800 : (GMT+08:00) Beijing, Chongqing, Hong Kong, Urumqi. 4801 : (GMT+08:00) Irkutsk, Ulaan Bataar. 4802 : (GMT+08:00) Kuala Lumpur, Singapore. 4803 : (GMT+08:00) Perth. 4804 : (GMT+08:00) Taipei. 5400 : (GMT+09:00) Osaka, Sapporo, Tokyo. 5401 : (GMT+09:00) Seoul. 5402 : (GMT+09:00) Yakutsk. 5700 : (GMT+09:30) Adelaide. 5701 : (GMT+09:30) Darwin. 6000 : (GMT+10:00) Brisbane. 6001 : (GMT+10:00) Canberra, Melbourne, Sydney. 6002 : (GMT+10:00) Guam, Port Moresby. 6003 : (GMT+10:00) Hobart. 6004 : (GMT+10:00) Vladivostok. 6600 : (GMT+11:00) Magadan, Solomon Is., New Caledonia. 7200 : (GMT+12:00) Auckland, Wellington. 7201 : (GMT+12:00) Fiji, Kamchatka, Marshall Is." ::= { sm24tat4xbSystemTimeZone 1 } sm24tat4xbSystemTimeZoneAcronym OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Acronym - User can set the acronym of the time zone. This is a User configurable acronym to identify the time zone. Range : 0 - 16 characters." ::= { sm24tat4xbSystemTimeZone 2 } --sm24tat4xbSystemTimeDaylightSaving sm24tat4xbSystemTimeDaylightSavingMode OBJECT-TYPE SYNTAX INTEGER { disable(0), recurring(1), nonRecurring(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The system Daylight Savings Mode. disable(0) : Disable. recurring(1) : Recurring - configure the Daylight Saving Time duration to repeat the configuration every year. nonRecurring(2): Non-Recurring - configure the Daylight Saving Time duration for single time configuration." DEFVAL { disable } ::= { sm24tat4xbSystemTimeDaylightSaving 1 } sm24tat4xbSystemTimeDaylightSavingStartWeek OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Week. Use in Recurring Mode. Range : 1 - 5. Default : 1." ::= { sm24tat4xbSystemTimeDaylightSaving 2 } sm24tat4xbSystemTimeDaylightSavingStartDay OBJECT-TYPE SYNTAX DayOfWeek MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Day. Use in Recurring Mode." DEFVAL { mon } ::= { sm24tat4xbSystemTimeDaylightSaving 3 } sm24tat4xbSystemTimeDaylightSavingStartMonth OBJECT-TYPE SYNTAX Month MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Month." DEFVAL { jan } ::= { sm24tat4xbSystemTimeDaylightSaving 4 } sm24tat4xbSystemTimeDaylightSavingStartDate OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Date. Use in Non-Recurring Mode. Range : 1 - 31. Default : 1." ::= { sm24tat4xbSystemTimeDaylightSaving 5 } sm24tat4xbSystemTimeDaylightSavingStartYear OBJECT-TYPE SYNTAX Integer32 (2000..2097) MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Year. Use in Non-Recurring Mode. Range : 2000 - 2097. Default : 2000." ::= { sm24tat4xbSystemTimeDaylightSaving 6 } sm24tat4xbSystemTimeDaylightSavingStartHours OBJECT-TYPE SYNTAX Integer32 (0..23) MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Hours. Range : 0 - 23. Default : 0." ::= { sm24tat4xbSystemTimeDaylightSaving 7 } sm24tat4xbSystemTimeDaylightSavingStartMinutes OBJECT-TYPE SYNTAX Integer32 (0..59) MAX-ACCESS read-write STATUS current DESCRIPTION "Start time Minutes. Range : 0 - 59. Default : 0." ::= { sm24tat4xbSystemTimeDaylightSaving 8 } sm24tat4xbSystemTimeDaylightSavingEndWeek OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "End time Week. Use in Recurring Mode. Range : 1 - 5. Default : 1." ::= { sm24tat4xbSystemTimeDaylightSaving 9 } sm24tat4xbSystemTimeDaylightSavingEndDay OBJECT-TYPE SYNTAX DayOfWeek MAX-ACCESS read-write STATUS current DESCRIPTION "End time Day. Use in Recurring Mode." DEFVAL { mon } ::= { sm24tat4xbSystemTimeDaylightSaving 10 } sm24tat4xbSystemTimeDaylightSavingEndMonth OBJECT-TYPE SYNTAX Month MAX-ACCESS read-write STATUS current DESCRIPTION "End time Month." DEFVAL { jan } ::= { sm24tat4xbSystemTimeDaylightSaving 11 } sm24tat4xbSystemTimeDaylightSavingEndDate OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-write STATUS current DESCRIPTION "End time Date. Use in Non-Recurring Mode. Range : 1 - 31. Default : 1." ::= { sm24tat4xbSystemTimeDaylightSaving 12 } sm24tat4xbSystemTimeDaylightSavingEndYear OBJECT-TYPE SYNTAX Integer32 (2000..2097) MAX-ACCESS read-write STATUS current DESCRIPTION "End time Year. Use in Non-Recurring Mode. Range : 2000 - 2097. Default : 2000." ::= { sm24tat4xbSystemTimeDaylightSaving 13 } sm24tat4xbSystemTimeDaylightSavingEndHours OBJECT-TYPE SYNTAX Integer32 (0..23) MAX-ACCESS read-write STATUS current DESCRIPTION "End time Hours. Range : 0 - 23. Default : 0." ::= { sm24tat4xbSystemTimeDaylightSaving 14 } sm24tat4xbSystemTimeDaylightSavingEndMinutes OBJECT-TYPE SYNTAX Integer32 (0..59) MAX-ACCESS read-write STATUS current DESCRIPTION "End time Minutes. Range : 0 - 59. Default : 0." ::= { sm24tat4xbSystemTimeDaylightSaving 15 } sm24tat4xbSystemTimeDaylightSavingOffset OBJECT-TYPE SYNTAX Integer32 (1..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "Offset - the number of minutes to add during Daylight Saving Time. Range : 1 - 1440(Minutes). Default : 1." ::= { sm24tat4xbSystemTimeDaylightSaving 16 } sm24tat4xbSystemTimeConfigurationClockSource OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Use Local Settings. 1:Use NTP Server." ::= { sm24tat4xbSystemTimeConfiguration 1} sm24tat4xbSystemTimeConfigurationSystemDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System date. Default format:yyyy-mm-dd. When ClockSource is Use Local Settings, you can set this field." ::= { sm24tat4xbSystemTimeConfiguration 2} sm24tat4xbSystemTimeConfigurationDateFormat OBJECT-TYPE SYNTAX Integer32 (0|1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "The date format of the system. 0:yyyy-mm-dd 1:mm-dd-yyyy 2:dd-mm-yyyy" ::= { sm24tat4xbSystemTimeConfiguration 3} sm24tat4xbSystemTimeConfigurationTimeFormat OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "The time format of the system. 0:24-hr, format:hh:mm:ss 1:12-hr, format:hh:mm:ss am/pm" ::= { sm24tat4xbSystemTimeConfiguration 4} sm24tat4xbSystemTimeConfigurationSystemTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "System date. 24-hr, format:hh:mm:ss 12-hr, format:hh:mm:ss am/pm When ClockSource is Use Local Settings, you can set this field." ::= { sm24tat4xbSystemTimeConfiguration 5} -- ======================================================================================================================= sm24tat4xbSystemAccount OBJECT IDENTIFIER ::= { sm24tat4xbSystem 3 } sm24tat4xbSystemAccountUsers OBJECT IDENTIFIER ::= { sm24tat4xbSystemAccount 1 } -- -- ======================================================================================================================= -- Start sm24tat4xbUserConfig group -- ======================================================================================================================= --sm24tat4xbUserConfigTable sm24tat4xbUserConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBUserConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The User Config Table. " ::= { sm24tat4xbSystemAccountUsers 1 } sm24tat4xbUserConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBUserConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The User Config Entry." INDEX { sm24tat4xbUserConfigIndex } ::= { sm24tat4xbUserConfigTable 1 } SM24TAT4XBUserConfigEntry ::= SEQUENCE { sm24tat4xbUserConfigIndex Integer32, sm24tat4xbUserConfigUserName DisplayString, sm24tat4xbUserConfigPassword DisplayString, sm24tat4xbUserConfigPrivilegeLevel Integer32, sm24tat4xbUserConfigRowStatus RowStatus } sm24tat4xbUserConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The user Config Index. " ::= { sm24tat4xbUserConfigEntry 1 } sm24tat4xbUserConfigUserName OBJECT-TYPE SYNTAX DisplayString(SIZE (1..31)) MAX-ACCESS read-create STATUS current DESCRIPTION "A string identifying the user name for the entry. string length: 1-31. " ::= { sm24tat4xbUserConfigEntry 2 } sm24tat4xbUserConfigPassword OBJECT-TYPE SYNTAX DisplayString(SIZE (0..31)) MAX-ACCESS read-create STATUS current DESCRIPTION "The password of the user. string length: 0-31. " ::= { sm24tat4xbUserConfigEntry 3 } sm24tat4xbUserConfigPrivilegeLevel OBJECT-TYPE SYNTAX Integer32(1..15) MAX-ACCESS read-create STATUS current DESCRIPTION "The privilege level of the user.If the privilege level value is 15, it can access all groups.range: 1-15. " ::= { sm24tat4xbUserConfigEntry 4 } sm24tat4xbUserConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbUserConfigEntry 5 } -- -- ======================================================================================================================= -- Start sm24tat4xbPrivilegeLevelConfig group -- ======================================================================================================================= --sm24tat4xbPrivilegeLevelConfigTable sm24tat4xbPrivilegeLevelConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPrivilegeLevelConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Privilege Level Config Table. " ::= { sm24tat4xbSystemAccountUsers 2 } sm24tat4xbPrivilegeLevelConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBPrivilegeLevelConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Privilege Level Config Entry." INDEX { sm24tat4xbPrivilegeLevelIndex } ::= { sm24tat4xbPrivilegeLevelConfigTable 1 } SM24TAT4XBPrivilegeLevelConfigEntry ::= SEQUENCE { sm24tat4xbPrivilegeLevelIndex Integer32, sm24tat4xbPrivilegeLevelGroupName DisplayString, sm24tat4xbPrivilegeLevelConfigReadOnly Integer32, sm24tat4xbPrivilegeLevelConfigReadWrite Integer32, sm24tat4xbPrivilegeLevelStatusReadOnly Integer32, sm24tat4xbPrivilegeLevelStatusReadWrite Integer32 } sm24tat4xbPrivilegeLevelIndex OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Privilege Level Index. " ::= { sm24tat4xbPrivilegeLevelConfigEntry 1 } sm24tat4xbPrivilegeLevelGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name identifying the privilege group." ::= { sm24tat4xbPrivilegeLevelConfigEntry 2 } sm24tat4xbPrivilegeLevelConfigReadOnly OBJECT-TYPE SYNTAX Integer32(1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The privilege level of configuration read-only.If the privilege level value is 15,it can access all groups. range: 1-15. " ::= { sm24tat4xbPrivilegeLevelConfigEntry 3 } sm24tat4xbPrivilegeLevelConfigReadWrite OBJECT-TYPE SYNTAX Integer32(1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The privilege level of configuration/execute read/write. If the privilege level value is 15,it can access all groups. range: 1-15. " ::= { sm24tat4xbPrivilegeLevelConfigEntry 4 } sm24tat4xbPrivilegeLevelStatusReadOnly OBJECT-TYPE SYNTAX Integer32(1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The privilege level of status/statistics read-only. If the privilege level value is 15,it can access all groups. range: 1-15. " ::= { sm24tat4xbPrivilegeLevelConfigEntry 5 } sm24tat4xbPrivilegeLevelStatusReadWrite OBJECT-TYPE SYNTAX Integer32(1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "The privilege level of status/statistics read-write. If the privilege level value is 15,it can access all groups. range: 1-15. " ::= { sm24tat4xbPrivilegeLevelConfigEntry 6 } -- ======================================================================================================================= sm24tat4xbIP OBJECT IDENTIFIER ::= { sm24tat4xbSystem 4 } sm24tat4xbIPConfigurationBasic OBJECT IDENTIFIER ::= { sm24tat4xbIP 1 } sm24tat4xbIPConfigIPv4DHCPClientEnable OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 DHCP Client Enabled 0: Disable 1: Enable" ::= {sm24tat4xbIPConfigurationBasic 1 } sm24tat4xbIPConfigIPv4Address OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 Address." ::= {sm24tat4xbIPConfigurationBasic 2 } sm24tat4xbIPConfigSubnetMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 SubnetMask." ::= {sm24tat4xbIPConfigurationBasic 3 } sm24tat4xbIPConfigGateway OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 Gateway." ::= {sm24tat4xbIPConfigurationBasic 4 } sm24tat4xbIPConfigDNSServer OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS Server Source. 0: No DNS configuration is applied 1: DNS configuration is manually set 2: DNS configuration is derived from DHCPv4 3: DNS configuration is derived from DHCPv4 on specific VLAN. 4. DNS configuration is derived from DHCPv6. 5. DNS configuration is derived from DHCPv6 on specific VLAN. " ::= {sm24tat4xbIPConfigurationBasic 5 } sm24tat4xbIPConfigDNSServerValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DNS IPv4 Address or VLAN value." ::= {sm24tat4xbIPConfigurationBasic 6 } sm24tat4xbIPConfiguration OBJECT IDENTIFIER ::= { sm24tat4xbIP 2 } sm24tat4xbMode OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IP Configuration Mode. default:0 0: Host 1: Router" ::= {sm24tat4xbIPConfiguration 2 } sm24tat4xbDNSServerSource1 OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS Server Source. 0: No DNS configuration is applied 1: DNS configuration is manually set 2: DNS configuration is derived from DHCPv4 3: DNS configuration is derived from DHCPv4 on specific VLAN. 4. DNS configuration is derived from DHCPv6. 5. DNS configuration is derived from DHCPv6 on specific VLAN. " ::= {sm24tat4xbIPConfiguration 3 } sm24tat4xbDNSServerSource2 OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS Server Source. 0: No DNS configuration is applied 1: DNS configuration is manually set 2: DNS configuration is derived from DHCPv4 3: DNS configuration is derived from DHCPv4 on specific VLAN. 4. DNS configuration is derived from DHCPv6. 5. DNS configuration is derived from DHCPv6 on specific VLAN. " ::= {sm24tat4xbIPConfiguration 4 } sm24tat4xbDNSServerSource3 OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS Server Source. 0: No DNS configuration is applied 1: DNS configuration is manually set 2: DNS configuration is derived from DHCPv4 3: DNS configuration is derived from DHCPv4 on specific VLAN. 4. DNS configuration is derived from DHCPv6. 5. DNS configuration is derived from DHCPv6 on specific VLAN. " ::= {sm24tat4xbIPConfiguration 5 } sm24tat4xbDNSServerSource4 OBJECT-TYPE SYNTAX Integer32 (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS Server Source. 0: No DNS configuration is applied 1: DNS configuration is manually set 2: DNS configuration is derived from DHCPv4 3: DNS configuration is derived from DHCPv4 on specific VLAN. 4. DNS configuration is derived from DHCPv6. 5. DNS configuration is derived from DHCPv6 on specific VLAN. " ::= {sm24tat4xbIPConfiguration 6 } sm24tat4xbDNSServerValue1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DNS IPv4/IPv6 Address or VLAN value." ::= {sm24tat4xbIPConfiguration 7 } sm24tat4xbDNSServerValue2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DNS IPv4/IPv6 Address or VLAN value." ::= {sm24tat4xbIPConfiguration 8 } sm24tat4xbDNSServerValue3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DNS IPv4/IPv6 Address or VLAN value." ::= {sm24tat4xbIPConfiguration 9 } sm24tat4xbDNSServerValue4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "DNS IPv4/IPv6 Address or VLAN value." ::= {sm24tat4xbIPConfiguration 10 } sm24tat4xbDNSProxy OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "DNS Proxy enable/disable. default:0 0: disable 1: enable" ::= {sm24tat4xbIPConfiguration 11 } sm24tat4xbIPInterfaces OBJECT IDENTIFIER ::= { sm24tat4xbIP 3 } sm24tat4xbIPInterfacesDHCPPerPortMode OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The dhcp per-port mode for the interface. 0: Disable, 1: Enable, default: Disable. " ::= { sm24tat4xbIPInterfaces 1 } sm24tat4xbIPInterfacesDHCPPerPortIPRangeLow OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The dhcp per-port ip low for the interface." ::= { sm24tat4xbIPInterfaces 2 } sm24tat4xbIPInterfacesDHCPPerPortIPRangeHigh OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The dhcp per-port ip high for the interface." ::= { sm24tat4xbIPInterfaces 3 } sm24tat4xbIPInterfacesDHCPPerPortApply OBJECT-TYPE SYNTAX Integer32 (1) MAX-ACCESS read-write STATUS current DESCRIPTION "1: Apply DHCP Per Port settings." ::= { sm24tat4xbIPInterfaces 4 } sm24tat4xbIPInterfacesDHCPPerPortVLAN OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "dhcp per-port VLAN." ::= { sm24tat4xbIPInterfaces 6 } sm24tat4xbIPInterfacesTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPInterfacesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of IP interface for switch." ::= { sm24tat4xbIPInterfaces 5 } sm24tat4xbIPInterfacesEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPInterfacesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the sm24tat4xbIPInterfacesTable." INDEX { sm24tat4xbIPInterfacesIndex } ::= { sm24tat4xbIPInterfacesTable 1 } SM24TAT4XBIPInterfacesEntry ::= SEQUENCE { sm24tat4xbIPInterfacesIndex Integer32, sm24tat4xbIPInterfacesVLAN Integer32, sm24tat4xbIPInterfacesIPv4DHCP Integer32, sm24tat4xbIPInterfacesIPv4DHCPFallback DisplayString, sm24tat4xbIPInterfacesIPv4DHCPCurrentLease IpAddress, sm24tat4xbIPInterfacesIPv4Address IpAddress, sm24tat4xbIPInterfacesIPv4Mask Integer32, sm24tat4xbIPInterfacesIPv6DHCP Integer32, sm24tat4xbIPInterfacesIPv6RapidCommit Integer32, sm24tat4xbIPInterfacesIPv6CurrentLease DisplayString, sm24tat4xbIPInterfacesIPv6Address DisplayString, sm24tat4xbIPInterfacesIPv6Mask Integer32, sm24tat4xbIPInterfacesRowStatus RowStatus } sm24tat4xbIPInterfacesIndex OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS not-accessible STATUS current DESCRIPTION "interface table index" ::= {sm24tat4xbIPInterfacesEntry 1 } sm24tat4xbIPInterfacesVLAN OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN ID for interface, range: 1-4095." ::= {sm24tat4xbIPInterfacesEntry 2 } sm24tat4xbIPInterfacesIPv4DHCP OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 DHCP Setting for interface. default:0 0: disable 1: enable" ::= {sm24tat4xbIPInterfacesEntry 3 } sm24tat4xbIPInterfacesIPv4DHCPFallback OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 DHCP fallbcak. range: 1-4294967295 seconds." ::= {sm24tat4xbIPInterfacesEntry 4 } sm24tat4xbIPInterfacesIPv4DHCPCurrentLease OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IPv4 DHCP Current Lease Address for interface." ::= {sm24tat4xbIPInterfacesEntry 5 } sm24tat4xbIPInterfacesIPv4Address OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 address for interface." ::= {sm24tat4xbIPInterfacesEntry 6 } sm24tat4xbIPInterfacesIPv4Mask OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 mask for interface." ::= { sm24tat4xbIPInterfacesEntry 7 } sm24tat4xbIPInterfacesIPv6DHCP OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv6 DHCP Setting for interface. default:0 0: disable 1: enable" ::= {sm24tat4xbIPInterfacesEntry 8 } sm24tat4xbIPInterfacesIPv6RapidCommit OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Enable the DHCPv6 Rapid-Commit option. default:0 0: disable 1: enable" ::= {sm24tat4xbIPInterfacesEntry 9 } sm24tat4xbIPInterfacesIPv6CurrentLease OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IPv6 DHCP Current Lease Address for interface." ::= {sm24tat4xbIPInterfacesEntry 10 } sm24tat4xbIPInterfacesIPv6Address OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv6 address for interface." ::= { sm24tat4xbIPInterfacesEntry 11 } sm24tat4xbIPInterfacesIPv6Mask OBJECT-TYPE SYNTAX Integer32 (1..128) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv6 mask for interface." ::= { sm24tat4xbIPInterfacesEntry 12 } sm24tat4xbIPInterfacesRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbIPInterfacesEntry 13 } sm24tat4xbIPRoutes OBJECT IDENTIFIER ::= { sm24tat4xbIP 4 } sm24tat4xbIPRoutesTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPRoutesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP routes table for switch." ::= { sm24tat4xbIPRoutes 1 } sm24tat4xbIPRoutesEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPRoutesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in the sm24tat4xbIPRoutesTable." INDEX { sm24tat4xbIPRoutesIndex } ::= { sm24tat4xbIPRoutesTable 1 } SM24TAT4XBIPRoutesEntry ::= SEQUENCE { sm24tat4xbIPRoutesIndex Integer32, sm24tat4xbIPRoutesNetwork DisplayString, sm24tat4xbIPRoutesMaskLength Integer32, sm24tat4xbIPRoutesGateway DisplayString, sm24tat4xbIPRoutesNextHopVLAN Integer32, sm24tat4xbIPRoutesRowStatus RowStatus } sm24tat4xbIPRoutesIndex OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS not-accessible STATUS current DESCRIPTION "routes table index" ::= {sm24tat4xbIPRoutesEntry 2 } sm24tat4xbIPRoutesNetwork OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4/IPv6 Network address. Please don't set IPRoutesNetwork to IPv6 and then Set IPRoutesGateway to IPv4, vice versa. Note: All entries in routes table will be sort by 1.network address 2.mask length 3. gateway 4. next hop VLAN, if you add/modify an entry, all entries will be reordered. Please check all entries in table to find your modified entry after set/add an entry. If Set IPRoutesNetwork, please also set IPRoutesMaskLength, IPRoutesGateway, IPRoutesNextHopVLAN." ::= {sm24tat4xbIPRoutesEntry 3 } sm24tat4xbIPRoutesMaskLength OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4/IPv6 mask length. Please set IPRoutesNetwork first. Note: All entries in routes table will be sort by 1.network address 2.mask length 3. gateway 4. next hop VLAN, if you add/modify an entry, all entries will be reordered. Please check all entries in table to find your modified entry after set/add an entry." ::= { sm24tat4xbIPRoutesEntry 4 } sm24tat4xbIPRoutesGateway OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4/IPv6 Gateway. Please set IPRoutesNetwork first. Please don't set IPRoutesNetwork to IPv6 and then Set IPRoutesGateway to IPv4, vice versa. Note: All entries in routes table will be sort by 1.network address 2.mask length 3. gateway 4. next hop VLAN, if you add/modify an entry, all entries will be reordered. Please check all entries in table to find your modified entry after set/add an entry." ::= {sm24tat4xbIPRoutesEntry 5 } sm24tat4xbIPRoutesNextHopVLAN OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Next Hop VLAN ID, range: 1-4095. Please set IPRoutesNetwork first. This entry only work when 1.network address is IPv6, 2.Gateway is link-local, 3.Interface of specific VLAN ID is IPv6. Note: All entries in routes table will be sort by 1.network address 2.mask length 3. gateway 4. next hop VLAN, if you add/modify an entry, all entries will be reordered. Please check all entries in table to find your modified entry after set/add an entry." ::= {sm24tat4xbIPRoutesEntry 6 } sm24tat4xbIPRoutesRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbIPRoutesEntry 7 } sm24tat4xbIPStatusInterface OBJECT IDENTIFIER ::= { sm24tat4xbIP 8 } sm24tat4xbIPStatusInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPStatusInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The system IP Status table to show all IP interfaces." ::= { sm24tat4xbIPStatusInterface 1 } sm24tat4xbIPStatusInterfaceEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPStatusInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the IP Status Table." INDEX { sm24tat4xbIPStatusInterfaceIndex } ::= { sm24tat4xbIPStatusInterfaceTable 1 } SM24TAT4XBIPStatusInterfaceEntry ::= SEQUENCE { sm24tat4xbIPStatusInterfaceIndex Integer32, sm24tat4xbIPStatusInterfaceName DisplayString, sm24tat4xbIPStatusInterfaceType DisplayString, sm24tat4xbIPStatusInterfaceAddress DisplayString, sm24tat4xbIPStatusInterfaceStatus DisplayString } sm24tat4xbIPStatusInterfaceIndex OBJECT-TYPE SYNTAX Integer32(1..1024) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of table to show all IP interfaces." ::= { sm24tat4xbIPStatusInterfaceEntry 1 } sm24tat4xbIPStatusInterfaceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the interface." ::= { sm24tat4xbIPStatusInterfaceEntry 2 } sm24tat4xbIPStatusInterfaceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The address type of the entry. This may be LINK or IPv4." ::= { sm24tat4xbIPStatusInterfaceEntry 3 } sm24tat4xbIPStatusInterfaceAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current address of the interface (of the given type)." ::= { sm24tat4xbIPStatusInterfaceEntry 4 } sm24tat4xbIPStatusInterfaceStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The status flags of the interface (and/or address)." ::= { sm24tat4xbIPStatusInterfaceEntry 5 } sm24tat4xbIPStatusRoute OBJECT IDENTIFIER ::= { sm24tat4xbIP 9 } sm24tat4xbIPStatusRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPStatusRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Status Route table show all routing entries." ::= { sm24tat4xbIPStatusRoute 1 } sm24tat4xbIPStatusRouteEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPStatusRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry in the IP Status route table." INDEX { sm24tat4xbIPStatusRouteIndex } ::= { sm24tat4xbIPStatusRouteTable 1 } SM24TAT4XBIPStatusRouteEntry ::= SEQUENCE { sm24tat4xbIPStatusRouteIndex Integer32, sm24tat4xbIPStatusRouteNetwork DisplayString, sm24tat4xbIPStatusRouteGateway DisplayString, sm24tat4xbIPStatusRouteAddress DisplayString } sm24tat4xbIPStatusRouteIndex OBJECT-TYPE SYNTAX Integer32(1..2048) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of table to show all routing entries." ::= { sm24tat4xbIPStatusRouteEntry 1 } sm24tat4xbIPStatusRouteNetwork OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The destination IP network or host address of this route." ::= { sm24tat4xbIPStatusRouteEntry 2 } sm24tat4xbIPStatusRouteGateway OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The gateway address of this route." ::= { sm24tat4xbIPStatusRouteEntry 3 } sm24tat4xbIPStatusRouteAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The route address." ::= { sm24tat4xbIPStatusRouteEntry 4 } sm24tat4xbIPStatusNeighborCache OBJECT IDENTIFIER ::= { sm24tat4xbIP 10 } sm24tat4xbIPStatusNeighborCacheTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPStatusNeighborCacheEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Ip Status Neighbor Cache Table." ::= { sm24tat4xbIPStatusNeighborCache 1 } sm24tat4xbIPStatusNeighborCacheEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPStatusNeighborCacheEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Ip Status Neighbor Cache Table." INDEX { sm24tat4xbIPStatusNeighborCacheIndex } ::= { sm24tat4xbIPStatusNeighborCacheTable 1 } SM24TAT4XBIPStatusNeighborCacheEntry ::= SEQUENCE { sm24tat4xbIPStatusNeighborCacheIndex Integer32, sm24tat4xbIPStatusNeighborCacheIPAddress DisplayString, sm24tat4xbIPStatusNeighborCacheLinkAddress DisplayString } sm24tat4xbIPStatusNeighborCacheIndex OBJECT-TYPE SYNTAX Integer32(1..1024) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index for the Ip Status Neighbor Cache Table." ::= { sm24tat4xbIPStatusNeighborCacheEntry 1 } sm24tat4xbIPStatusNeighborCacheIPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the entry." ::= { sm24tat4xbIPStatusNeighborCacheEntry 2 } sm24tat4xbIPStatusNeighborCacheLinkAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Link (MAC) address for which a binding to the IP address given exist." ::= { sm24tat4xbIPStatusNeighborCacheEntry 3 } sm24tat4xbIPStatusDNSServer OBJECT IDENTIFIER ::= { sm24tat4xbIP 11 } sm24tat4xbIPStatusDNSServerType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The configuration type of DNS server." ::= { sm24tat4xbIPStatusDNSServer 1 } sm24tat4xbIPStatusDNSServerIPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the DNS server." ::= { sm24tat4xbIPStatusDNSServer 2 } sm24tat4xbIPStatusDNSServerInterface OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the interface." ::= { sm24tat4xbIPStatusDNSServer 3 } -- ======================================================================================================================= sm24tat4xbSyslog OBJECT IDENTIFIER ::= { sm24tat4xbSystem 5 } sm24tat4xbSyslogConf OBJECT IDENTIFIER ::= { sm24tat4xbSyslog 1 } sm24tat4xbSysLogInfo OBJECT IDENTIFIER ::= { sm24tat4xbSyslog 2 } -- -- ======================================================================================================================= -- Objects in the sm24tat4xbSystemLog Group -- ======================================================================================================================= --sm24tat4xbSystemLogConf sm24tat4xbSystemLogServerMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "The System log server mode admin state." DEFVAL { disable } ::= { sm24tat4xbSyslogConf 1 } sm24tat4xbSystemLogServerAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The Host address of syslog server." ::= { sm24tat4xbSyslogConf 2 } -- sm24tat4xbSystemLogSyslogLevel OBJECT-TYPE -- SYNTAX INTEGER { -- info(0), -- warning(1), -- error(2) -- } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The syslog level. -- info(0) : Info. -- warning(1): Warning. -- error(2) : Error." -- DEFVAL { info } -- ::= { sm24tat4xbSyslogConf 3 } sm24tat4xbSystemLogServerPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "syslog service port number. range : 1-65535, default : 514." ::= { sm24tat4xbSyslogConf 4 } --sm24tat4xbSystemLogInfo sm24tat4xbSystemLogInfoLevel OBJECT-TYPE SYNTAX INTEGER { emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), information(6), debug(7), all(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Level input field is used to filter the display system log entries. 0: Emergency. 1: Alert. 2: Critical. 3: Error. 4: Warning. 5: Notice. 6: Information. 7: Debug. 8: All." DEFVAL { all } ::= { sm24tat4xbSysLogInfo 1 } sm24tat4xbSystemLogInfoClearLevel OBJECT-TYPE SYNTAX INTEGER { emergency(0), alert(1), critical(2), error(3), warning(4), notice(5), information(6), debug(7), all(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Clear Level input field is used to specify which system log entries will be cleared. default: 8 (All). 0: Emergency. 1: Alert. 2: Critical. 3: Error. 4: Warning. 5: Notice. 6: Information. 7: Debug. 8: All." DEFVAL { all } ::= { sm24tat4xbSysLogInfo 2 } sm24tat4xbSystemLogInfoClearCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Command to clear the syslog. noAction(0) : do nothing (read only). activate(1) : Clear Syslog." DEFVAL { noAction } ::= { sm24tat4xbSysLogInfo 3 } sm24tat4xbSystemLogDetailedInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSystemLogDetailedInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The system detailed Log Info table." ::= { sm24tat4xbSysLogInfo 4 } sm24tat4xbSystemLogDetailedInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBSystemLogDetailedInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the system detailed Log Info table." INDEX { sm24tat4xbSystemLogDetailedInfoID } ::= { sm24tat4xbSystemLogDetailedInfoTable 1 } SM24TAT4XBSystemLogDetailedInfoEntry ::= SEQUENCE { sm24tat4xbSystemLogDetailedSwitchIndex Integer32, sm24tat4xbSystemLogDetailedInfoID Integer32, sm24tat4xbSystemLogDetailedInfoLevel DisplayString, sm24tat4xbSystemLogDetailedInfoTime DisplayString, sm24tat4xbSystemLogDetailedInfoMessage DisplayString } sm24tat4xbSystemLogDetailedSwitchIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The switch index for the system detailed Log Info table." ::= { sm24tat4xbSystemLogDetailedInfoEntry 1 } sm24tat4xbSystemLogDetailedInfoID OBJECT-TYPE SYNTAX Integer32(1..999) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index for the system detailed Log Info table." ::= { sm24tat4xbSystemLogDetailedInfoEntry 2 } sm24tat4xbSystemLogDetailedInfoLevel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Info Level." ::= { sm24tat4xbSystemLogDetailedInfoEntry 3 } sm24tat4xbSystemLogDetailedInfoTime OBJECT-TYPE SYNTAX DisplayString(SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The time" ::= { sm24tat4xbSystemLogDetailedInfoEntry 4 } sm24tat4xbSystemLogDetailedInfoMessage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The message of this entry." ::= { sm24tat4xbSystemLogDetailedInfoEntry 5 } -- ======================================================================================================================= sm24tat4xbSnmp OBJECT IDENTIFIER ::= { sm24tat4xbSystem 6 } sm24tat4xbSnmpSystem OBJECT IDENTIFIER ::= { sm24tat4xbSnmp 1 } sm24tat4xbSnmpSystemMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP mode operation. default : 1, 0: disable, 1: enable. " ::= { sm24tat4xbSnmpSystem 1 } sm24tat4xbSnmpSystemVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP supported version. default : snmpv2c. 1: snmpv1 2: snmpv2c 3: snmpv3." ::= { sm24tat4xbSnmpSystem 2 } sm24tat4xbSnmpSystemReadCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the community read access string to permit access to SNMP agent. The allowed string length is 0 to 255. The field is applicable only when SNMP version is SNMPv1 or SNMPv2c." ::= { sm24tat4xbSnmpSystem 3 } sm24tat4xbSnmpSystemWriteCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the community write access string to permit access to SNMP agent. The allowed string length is 0 to 255. The field is applicable only when SNMP version is SNMPv1 or SNMPv2c." ::= { sm24tat4xbSnmpSystem 4 } --sm24tat4xbSnmpSystemEngineID OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the SNMPv3 engine ID. -- The string must contain an even number(in hexadecimal format) with number of digits between 10 and 64, -- but all-zeros and all-'F's are not allowed. -- Allow string length is 10 to 32. -- Change of the Engine ID will clear all original local users." -- ::= { sm24tat4xbSnmpSystem 5 } sm24tat4xbSnmpSystemWriteCommunityMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP write community mode operation. default : 1, 0: disable, 1: enable. " ::= { sm24tat4xbSnmpSystem 6 } sm24tat4xbSnmpSystemReadCommunityMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP read community mode operation. default : 1, 0: disable, 1: enable. " ::= { sm24tat4xbSnmpSystem 7 } --sm24tat4xbSnmpTrapGlobalMode OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the trap mode operation. -- 0:Disable. -- 1:Enable." -- ::= { sm24tat4xbSnmp 2 } sm24tat4xbTrapDestinationConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBTrapDestinationConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of trap host entry. The numbers of entries are given by the value of TrapHostConfNumber." ::= { sm24tat4xbSnmp 3 } sm24tat4xbTrapDestinationConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBTrapDestinationConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for trap host." INDEX { sm24tat4xbTrapDestinationConfIndex } ::= { sm24tat4xbTrapDestinationConfTable 1 } SM24TAT4XBTrapDestinationConfEntry ::= SEQUENCE { sm24tat4xbTrapDestinationConfIndex Integer32, sm24tat4xbTrapDestinationConfTrapConfigName DisplayString, sm24tat4xbTrapDestinationConfTrapMode Integer32, sm24tat4xbTrapDestinationConfTrapVersion Integer32, sm24tat4xbTrapDestinationConfTrapCommunity DisplayString, sm24tat4xbTrapDestinationConfTrapDestinationAddres DisplayString, sm24tat4xbTrapDestinationConfTrapDestinationPort Integer32, -- sm24tat4xbTrapDestinationConfTrapInformMode Integer32, -- sm24tat4xbTrapDestinationConfTrapInformTimeout Integer32, -- sm24tat4xbTrapDestinationConfTrapInformRetryTimes Integer32, -- sm24tat4xbTrapDestinationConfTrapProbeSecurityEngineID Integer32, sm24tat4xbTrapDestinationConfTrapSecurityEngineID DisplayString, sm24tat4xbTrapDestinationConfTrapSecurityName DisplayString, sm24tat4xbTrapDestinationConfTrapRowStatus Integer32 } sm24tat4xbTrapDestinationConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of tarp destination configurations." ::= { sm24tat4xbTrapDestinationConfEntry 1 } sm24tat4xbTrapDestinationConfTrapConfigName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates which trap Configuration's name for configuring. The allowed string length is 0 to 255, and the allowed content is ASCII characters from 33 to 126." ::= { sm24tat4xbTrapDestinationConfEntry 2 } sm24tat4xbTrapDestinationConfTrapMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP mode operation. Possible modes are: 2: Enable TCP SNMP mode operation. 1: Enable UDP SNMP mode operation. 0: Disable SNMP mode operation. " ::= { sm24tat4xbTrapDestinationConfEntry 3 } sm24tat4xbTrapDestinationConfTrapVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0: snmpv1 1: snmpv2c 3: snmpv3. " ::= { sm24tat4xbTrapDestinationConfEntry 4 } sm24tat4xbTrapDestinationConfTrapCommunity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the community access string when sending SNMP trap packet. The allowed string length is 0 to 255, and the allowed content is ASCII characters from 33 to 126." ::= { sm24tat4xbTrapDestinationConfEntry 5 } sm24tat4xbTrapDestinationConfTrapDestinationAddres OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP trap destination address. It allow a valid IP address in dotted decimal notation ('x.y.z.w'). And it also allow a valid hostname. A valid hostname is a string drawn from the alphabet (A-Za-z), digits (0-9), dot (.), dash (-). Spaces are not allowed, the first character must be an alpha character, and the first and last characters must not be a dot or a dash. Indicates the SNMP trap destination IPv6 address. IPv6 address is in 128-bit records represented as eight fields of up to four hexadecimal digits with a colon separating each field (:). For example, 'fe80::215:c5ff:fe03:4dc7'. The symbol '::' is a special syntax that can be used as a shorthand way of representing multiple 16-bit groups of contiguous zeros; but it can appear only once. It can also represent a legally valid IPv4 address. For example, '::192.1.2.34'." ::= { sm24tat4xbTrapDestinationConfEntry 6 } sm24tat4xbTrapDestinationConfTrapDestinationPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP trap destination port. SNMP Agent will send SNMP message via this port, the port range is 1~65535." ::= { sm24tat4xbTrapDestinationConfEntry 7 } --sm24tat4xbTrapDestinationConfTrapInformMode OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the SNMP trap inform mode operation. Possible modes are: -- 1: Enable SNMP trap inform mode operation. -- 0: Disable SNMP trap inform mode operation. " -- ::= { sm24tat4xbTrapDestinationConfEntry 8 } -- --sm24tat4xbTrapDestinationConfTrapInformTimeout OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the SNMP trap inform timeout. The allowed range is 0 to 2147." -- ::= { sm24tat4xbTrapDestinationConfEntry 9 } -- --sm24tat4xbTrapDestinationConfTrapInformRetryTimes OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the SNMP trap inform retry times. The allowed range is 0 to 255." -- ::= { sm24tat4xbTrapDestinationConfEntry 10 } -- --sm24tat4xbTrapDestinationConfTrapProbeSecurityEngineID OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the SNMP trap probe security engine ID mode of operation. -- Possible values are: -- 1: Enable SNMP trap probe security engine ID mode of operation. -- 0: Disable SNMP trap probe security engine ID mode of operation." -- ::= { sm24tat4xbTrapDestinationConfEntry 11 } sm24tat4xbTrapDestinationConfTrapSecurityEngineID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP trap security engine ID. SNMPv3 sends traps and informs using USM for authentication and privacy. A unique engine ID for these traps and informs is needed. When Trap Probe Security Engine ID is enabled, the ID will be probed automatically. Otherwise, the ID specified in this field is used. The string must contain an even number(in hexadecimal format) with number of digits between 10 and 64, but all-zeros and all-'F's are not allowed." ::= { sm24tat4xbTrapDestinationConfEntry 12 } sm24tat4xbTrapDestinationConfTrapSecurityName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP trap security name. SNMPv3 traps and informs using USM for authentication and privacy. A unique security name is needed when traps and informs are enabled. This name from user name of user configuration." ::= { sm24tat4xbTrapDestinationConfEntry 13 } sm24tat4xbTrapDestinationConfTrapRowStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create(5)/delete(6) entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbTrapDestinationConfEntry 14 } sm24tat4xbSNMPCommunityConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSNMPCommunityConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of snmp community configuration entry." ::= { sm24tat4xbSnmp 5 } sm24tat4xbSNMPCommunityConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBSNMPCommunityConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for snmp community configuration." INDEX { sm24tat4xbSNMPCommunityConfIndex } ::= { sm24tat4xbSNMPCommunityConfTable 1 } SM24TAT4XBSNMPCommunityConfEntry ::= SEQUENCE { sm24tat4xbSNMPCommunityConfIndex Integer32, sm24tat4xbSNMPCommunityConfSNMPv3Community DisplayString, sm24tat4xbSNMPCommunityConfSNMPv3SourceIP IpAddress, sm24tat4xbSNMPCommunityConfSNMPv3SourceMask IpAddress, sm24tat4xbSNMPCommunityConfSNMPv3RowStatus Integer32 } sm24tat4xbSNMPCommunityConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Community configuration index." ::= { sm24tat4xbSNMPCommunityConfEntry 1 } sm24tat4xbSNMPCommunityConfSNMPv3Community OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the community access string to permit access to SNMPv3 agent. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126. The community string will be treated as security name and map a SNMPv1 or SNMPv2c community string." ::= { sm24tat4xbSNMPCommunityConfEntry 2 } sm24tat4xbSNMPCommunityConfSNMPv3SourceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP access source address. A particular range of source addresses can be used to restrict source subnet when combined with source mask." ::= {sm24tat4xbSNMPCommunityConfEntry 3 } sm24tat4xbSNMPCommunityConfSNMPv3SourceMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the SNMP access source address mask." ::= {sm24tat4xbSNMPCommunityConfEntry 4 } sm24tat4xbSNMPCommunityConfSNMPv3RowStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create(5)/delete(6) entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbSNMPCommunityConfEntry 5 } sm24tat4xbSNMPv3UserConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSNMPv3UserConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of snmpv3 user configuration entry." ::= { sm24tat4xbSnmp 6 } sm24tat4xbSNMPv3UserConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBSNMPv3UserConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for snmpv3 user configuration." INDEX { sm24tat4xbSNMPv3UserConfIndex } ::= { sm24tat4xbSNMPv3UserConfTable 1 } SM24TAT4XBSNMPv3UserConfEntry ::= SEQUENCE { sm24tat4xbSNMPv3UserConfIndex Integer32, sm24tat4xbSNMPv3UserConfEngineID DisplayString, sm24tat4xbSNMPv3UserConfUserName DisplayString, sm24tat4xbSNMPv3UserConfSecurityLevel Integer32, sm24tat4xbSNMPv3UserConfAuthenticationProtocol Integer32, sm24tat4xbSNMPv3UserConfAuthenticationPassword DisplayString, sm24tat4xbSNMPv3UserConfPrivacyProtocol Integer32, sm24tat4xbSNMPv3UserConfPrivacyPassword DisplayString, sm24tat4xbSNMPv3UserConfRowStatus RowStatus } sm24tat4xbSNMPv3UserConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "User configuration index." ::= { sm24tat4xbSNMPv3UserConfEntry 1 } sm24tat4xbSNMPv3UserConfEngineID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "An octet string identifying the engine ID that this entry should belong to. The string must contain an even number(in hexadecimal format) with number of digits between 10 and 64, but all-zeros and all-'F's are not allowed. The SNMPv3 architecture uses the User-based Security Model (USM) for message security and the View-based Access Control Model (VACM) for access control. For the USM entry, the usmUserEngineID and usmUserName are the entry's keys. In a simple agent, usmUserEngineID is always that agent's own snmpEngineID value. The value can also take the value of the snmpEngineID of a remote SNMP engine with which this user can communicate. In other words, if user engine ID equal system engine ID then it is local user; otherwise it's remote user. " ::= { sm24tat4xbSNMPv3UserConfEntry 2 } sm24tat4xbSNMPv3UserConfUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the user name that this entry should belong to. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126." ::= { sm24tat4xbSNMPv3UserConfEntry 3 } sm24tat4xbSNMPv3UserConfSecurityLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1:NoAuth, NoPriv 2:Auth, NoPriv 3:Auth, Priv" ::= { sm24tat4xbSNMPv3UserConfEntry 4 } sm24tat4xbSNMPv3UserConfAuthenticationProtocol OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:None 1:MD5 2:SHA" ::= { sm24tat4xbSNMPv3UserConfEntry 5 } sm24tat4xbSNMPv3UserConfAuthenticationPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the authentication password phrase. For MD5 authentication protocol, the allowed string length is 8 to 32. For SHA authentication protocol, the allowed string length is 8 to 40. The allowed content is ASCII characters from 33 to 126." ::= { sm24tat4xbSNMPv3UserConfEntry 6 } sm24tat4xbSNMPv3UserConfPrivacyProtocol OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:None 1:DES 2:AES" ::= { sm24tat4xbSNMPv3UserConfEntry 7 } sm24tat4xbSNMPv3UserConfPrivacyPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the privacy password phrase. The allowed string length is 8 to 32, and the allowed content is ASCII characters from 33 to 126." ::= { sm24tat4xbSNMPv3UserConfEntry 8 } sm24tat4xbSNMPv3UserConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create(5)/delete(6) entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbSNMPv3UserConfEntry 9 } sm24tat4xbSNMPv3GroupConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSNMPv3GroupConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of snmpv3 group configuration entry." ::= { sm24tat4xbSnmp 7 } sm24tat4xbSNMPv3GroupConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBSNMPv3GroupConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for snmpv3 group configuration." INDEX { sm24tat4xbSNMPv3GroupConfIndex } ::= { sm24tat4xbSNMPv3GroupConfTable 1 } SM24TAT4XBSNMPv3GroupConfEntry ::= SEQUENCE { sm24tat4xbSNMPv3GroupConfIndex Integer32, sm24tat4xbSNMPv3GroupConfSecurityModel Integer32, sm24tat4xbSNMPv3GroupConfSecurityName DisplayString, sm24tat4xbSNMPv3GroupConfGroupName DisplayString, sm24tat4xbSNMPv3GroupConfRowStatus RowStatus } sm24tat4xbSNMPv3GroupConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Group configuration index." ::= { sm24tat4xbSNMPv3GroupConfEntry 1 } sm24tat4xbSNMPv3GroupConfSecurityModel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1:v1 2:v2c 3:usm" ::= { sm24tat4xbSNMPv3GroupConfEntry 2 } sm24tat4xbSNMPv3GroupConfSecurityName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the security name that this entry should belong to. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126. This name is from the Community of Community configuration." ::= { sm24tat4xbSNMPv3GroupConfEntry 3 } sm24tat4xbSNMPv3GroupConfGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the group name that this entry should belong to. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126. " ::= { sm24tat4xbSNMPv3GroupConfEntry 4 } sm24tat4xbSNMPv3GroupConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create(5)/delete(6) entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbSNMPv3GroupConfEntry 5 } sm24tat4xbSNMPv3ViewsConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSNMPv3ViewsConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of snmpv3 view configuration entry." ::= { sm24tat4xbSnmp 8 } sm24tat4xbSNMPv3ViewsConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBSNMPv3ViewsConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for snmpv3 view configuration." INDEX { sm24tat4xbSNMPv3ViewsConfIndex } ::= { sm24tat4xbSNMPv3ViewsConfTable 1 } SM24TAT4XBSNMPv3ViewsConfEntry ::= SEQUENCE { sm24tat4xbSNMPv3ViewsConfIndex Integer32, sm24tat4xbSNMPv3ViewsConfViewName DisplayString, sm24tat4xbSNMPv3ViewsConfViewType Integer32, sm24tat4xbSNMPv3ViewsConfOIDSubtree DisplayString, sm24tat4xbSNMPv3ViewsConfRowStatus RowStatus } sm24tat4xbSNMPv3ViewsConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "view configuration index." ::= { sm24tat4xbSNMPv3ViewsConfEntry 1 } sm24tat4xbSNMPv3ViewsConfViewName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A string identifying the view name that this entry should belong to. The allowed string length is 1 to 32, and the allowed content is ASCII characters from 33 to 126. " ::= { sm24tat4xbSNMPv3ViewsConfEntry 2 } sm24tat4xbSNMPv3ViewsConfViewType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:included 1:excluded" ::= { sm24tat4xbSNMPv3ViewsConfEntry 3 } sm24tat4xbSNMPv3ViewsConfOIDSubtree OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The OID defining the root of the subtree to add to the named view. The allowed OID length is 1 to 128. The allowed string content is digital number or asterisk(*)" ::= { sm24tat4xbSNMPv3ViewsConfEntry 4 } sm24tat4xbSNMPv3ViewsConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create(5)/delete(6) entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbSNMPv3ViewsConfEntry 5 } sm24tat4xbSNMPv3AccessConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSNMPv3AccessConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of snmpv3 access configuration entry." ::= { sm24tat4xbSnmp 9 } sm24tat4xbSNMPv3AccessConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBSNMPv3AccessConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is the entry information for snmpv3 access configuration." INDEX { sm24tat4xbSNMPv3AccessConfIndex } ::= { sm24tat4xbSNMPv3AccessConfTable 1 } SM24TAT4XBSNMPv3AccessConfEntry ::= SEQUENCE { sm24tat4xbSNMPv3AccessConfIndex Integer32, sm24tat4xbSNMPv3AccessConfGroupName DisplayString, sm24tat4xbSNMPv3AccessConfSecurityModel Integer32, sm24tat4xbSNMPv3AccessConfSecurityLevel Integer32, sm24tat4xbSNMPv3AccessConfReadViewName DisplayString, sm24tat4xbSNMPv3AccessConfWriteViewName DisplayString, sm24tat4xbSNMPv3AccessConfRowStatus RowStatus } sm24tat4xbSNMPv3AccessConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Access configuration index" ::= { sm24tat4xbSNMPv3AccessConfEntry 1 } sm24tat4xbSNMPv3AccessConfGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Group name from Group configuration." ::= { sm24tat4xbSNMPv3AccessConfEntry 2 } sm24tat4xbSNMPv3AccessConfSecurityModel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:any 1:v1 2:v2c 3:usm" ::= { sm24tat4xbSNMPv3AccessConfEntry 3 } sm24tat4xbSNMPv3AccessConfSecurityLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1:NoAuth, NoPriv 2:Auth, NoPriv 3:Auth, Priv" ::= { sm24tat4xbSNMPv3AccessConfEntry 4 } sm24tat4xbSNMPv3AccessConfReadViewName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Read View Name from View configuration." ::= { sm24tat4xbSNMPv3AccessConfEntry 5 } sm24tat4xbSNMPv3AccessConfWriteViewName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Write View Name from View configuration." ::= { sm24tat4xbSNMPv3AccessConfEntry 6 } sm24tat4xbSNMPv3AccessConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create(5)/delete(6) entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbSNMPv3AccessConfEntry 7 } -- ======================================================================================================================= sm24tat4xbDHCPServer OBJECT IDENTIFIER ::= { sm24tat4xbSystem 9 } sm24tat4xbDHCPServerConfig OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 7 } sm24tat4xbDHCPServerConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBDHCPServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPServerConfig 1 } sm24tat4xbDHCPServerConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBDHCPServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbDHCPServerConfigIndex } ::= { sm24tat4xbDHCPServerConfigTable 1 } SM24TAT4XBDHCPServerConfigEntry ::= SEQUENCE { sm24tat4xbDHCPServerConfigIndex Integer32, sm24tat4xbDHCPServerConfigInterfaceVLAN Integer32, sm24tat4xbDHCPServerConfigInterfaceMode Integer32, sm24tat4xbDHCPServerConfigInterfaceStartIPEndIP DisplayString, -- sm24tat4xbDHCPServerConfigInterfaceEndIP IpAddress, sm24tat4xbDHCPServerConfigInterfaceLeaseTime Integer32, sm24tat4xbDHCPServerConfigInterfaceSubnetMask IpAddress, sm24tat4xbDHCPServerConfigInterfaceDefaultRouter IpAddress, sm24tat4xbDHCPServerConfigInterfaceDNSServer IpAddress } sm24tat4xbDHCPServerConfigIndex OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS not-accessible STATUS current DESCRIPTION "table index." ::= {sm24tat4xbDHCPServerConfigEntry 1 } sm24tat4xbDHCPServerConfigInterfaceVLAN OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN in which DHCP server is enabled or disabled. " ::= {sm24tat4xbDHCPServerConfigEntry 2 } sm24tat4xbDHCPServerConfigInterfaceMode OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate the operation mode per VLAN. 0:disable 1:enable" ::= {sm24tat4xbDHCPServerConfigEntry 3 } sm24tat4xbDHCPServerConfigInterfaceStartIPEndIP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Please set SubnetMask first. Start IP and End IP. Format: x.x.x.x-x.x.x.x" ::= {sm24tat4xbDHCPServerConfigEntry 4 } --sm24tat4xbDHCPServerConfigInterfaceEndIP OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "End IP" -- ::= {sm24tat4xbDHCPServerConfigEntry 5 } sm24tat4xbDHCPServerConfigInterfaceLeaseTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The lease time in second." ::= {sm24tat4xbDHCPServerConfigEntry 6 } sm24tat4xbDHCPServerConfigInterfaceSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Configure subnet mask of the DHCP address. " ::= {sm24tat4xbDHCPServerConfigEntry 7 } sm24tat4xbDHCPServerConfigInterfaceDefaultRouter OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the destination IP network or host address of the default route." ::= {sm24tat4xbDHCPServerConfigEntry 8 } sm24tat4xbDHCPServerConfigInterfaceDNSServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the default DNS server. " ::= {sm24tat4xbDHCPServerConfigEntry 9 } sm24tat4xbDHCPServerStatus OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 8 } sm24tat4xbDHCPServerStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBDHCPServerStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPServerStatus 1 } sm24tat4xbDHCPServerStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBDHCPServerStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbDHCPServerStatusIndex } ::= { sm24tat4xbDHCPServerStatusTable 1 } SM24TAT4XBDHCPServerStatusEntry ::= SEQUENCE { sm24tat4xbDHCPServerStatusIndex Integer32, sm24tat4xbDHCPServerStatusInterfaceVLAN Integer32, sm24tat4xbDHCPServerStatusInterfaceType DisplayString, sm24tat4xbDHCPServerStatusInterfaceStartIP IpAddress, sm24tat4xbDHCPServerStatusInterfaceEndIP IpAddress, sm24tat4xbDHCPServerStatusInterfaceLeaseTime Integer32, sm24tat4xbDHCPServerStatusInterfaceSubnetMask IpAddress, sm24tat4xbDHCPServerStatusInterfaceDefaultRouter IpAddress, sm24tat4xbDHCPServerStatusInterfaceDNSServer IpAddress } sm24tat4xbDHCPServerStatusIndex OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS not-accessible STATUS current DESCRIPTION "table index." ::= {sm24tat4xbDHCPServerStatusEntry 1 } sm24tat4xbDHCPServerStatusInterfaceVLAN OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN in which DHCP server is enabled or disabled. " ::= {sm24tat4xbDHCPServerStatusEntry 2 } sm24tat4xbDHCPServerStatusInterfaceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= {sm24tat4xbDHCPServerStatusEntry 3 } sm24tat4xbDHCPServerStatusInterfaceStartIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Start IP" ::= {sm24tat4xbDHCPServerStatusEntry 4 } sm24tat4xbDHCPServerStatusInterfaceEndIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "End IP" ::= {sm24tat4xbDHCPServerStatusEntry 5 } sm24tat4xbDHCPServerStatusInterfaceLeaseTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The lease time in second." ::= {sm24tat4xbDHCPServerStatusEntry 6 } sm24tat4xbDHCPServerStatusInterfaceSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Configure subnet mask of the DHCP address. " ::= {sm24tat4xbDHCPServerStatusEntry 7 } sm24tat4xbDHCPServerStatusInterfaceDefaultRouter OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Configure the destination IP network or host address of the default route." ::= {sm24tat4xbDHCPServerStatusEntry 8 } sm24tat4xbDHCPServerStatusInterfaceDNSServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Configure the default DNS server. " ::= {sm24tat4xbDHCPServerStatusEntry 9 } --sm24tat4xbDHCPServerConf OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 1 } -- --sm24tat4xbDHCPServerGlobalMode OBJECT-TYPE -- SYNTAX Integer32 (0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0, -- Global Mode : -- 0: Disable, -- 1: Enable. -- " -- ::= { sm24tat4xbDHCPServerConf 1 } -- --sm24tat4xbDHCPServerVLANMode OBJECT-TYPE -- SYNTAX Integer32 (0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0, -- 0: Disable, -- 1: Enable. -- " -- ::= { sm24tat4xbDHCPServerConf 2 } -- --sm24tat4xbVLANModeTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBVLANModeEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A table of VLAN Mode for DHCP Server." -- ::= { sm24tat4xbDHCPServerConf 2 } --sm24tat4xbVLANModeEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBVLANModeEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "An entry in the sm24tat4xbVLANModeTable." -- INDEX { sm24tat4xbVLANModeIndex } -- ::= { sm24tat4xbVLANModeTable 1 } -- --SM24TAT4XBVLANModeEntry ::= -- SEQUENCE { -- sm24tat4xbVLANModeIndex Integer32, -- sm24tat4xbVLANModeRangeLow Integer32, -- sm24tat4xbVLANModeRangeHigh Integer32, -- sm24tat4xbVLANModeEnable Integer32, -- sm24tat4xbVLANModeRowStatus RowStatus -- } -- --sm24tat4xbVLANModeIndex OBJECT-TYPE -- SYNTAX Integer32 (1..2048) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "VLAN Mode table index, range: 1-2048." -- ::= {sm24tat4xbVLANModeEntry 1 } -- --sm24tat4xbVLANModeRangeLow OBJECT-TYPE -- SYNTAX Integer32 (1..4095) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "VLAN Mode low range: 1-4095." -- ::= {sm24tat4xbVLANModeEntry 2 } -- --sm24tat4xbVLANModeRangeHigh OBJECT-TYPE -- SYNTAX Integer32 (1..4095) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "VLAN Mode high range: 1-4095." -- ::= {sm24tat4xbVLANModeEntry 3 } -- --sm24tat4xbVLANModeEnable OBJECT-TYPE -- SYNTAX Integer32 (0..1) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "VLAN Mode Enable, Enable:1, Disable:0." -- ::= {sm24tat4xbVLANModeEntry 4 } -- --sm24tat4xbVLANModeRowStatus OBJECT-TYPE -- SYNTAX RowStatus -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "This object indicates the status of this entry, and is -- used to create/delete entries. Any object in an entry of -- this table may be modified while the value of the -- corresponding instance of this object is active(1). -- createAndGo, notReady not supported." -- ::= { sm24tat4xbVLANModeEntry 5 } -- -- sm24tat4xbDHCPServerBindingType OBJECT-TYPE -- SYNTAX Integer32 (0|1|2|3) -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "default: None, -- Global Mode : -- 0: None, -- 1: Automatic, -- 2: Manual, -- 3: Expired. -- " -- ::= { sm24tat4xbDHCPServerConf 2 } -- sm24tat4xbDHCPServerBindingState OBJECT-TYPE -- SYNTAX Integer32 (0|1|2|3) -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "default: None, -- Global Mode : -- 0: None, -- 1: Allocated, -- 2: Committed, -- 3: Expired. -- " -- ::= { sm24tat4xbDHCPServerConf 3 } -- sm24tat4xbDHCPServerBindingIP OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "The DHCP Server Binding IP" -- ::= { sm24tat4xbDHCPServerConf 4 } -- -- --sm24tat4xbDHCPServerExcludedIP OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 2 } -- --sm24tat4xbExcludedIPTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBExcludedIPEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A table of Excluded IP for DHCP Server." -- ::= { sm24tat4xbDHCPServerExcludedIP 1 } -- --sm24tat4xbExcludedIPEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBExcludedIPEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "An entry in the sm24tat4xbExcludedIPTable." -- INDEX { sm24tat4xbExcludedIPIndex } -- ::= { sm24tat4xbExcludedIPTable 1 } -- --SM24TAT4XBExcludedIPEntry ::= -- SEQUENCE { -- sm24tat4xbExcludedIPIndex Integer32, -- sm24tat4xbExcludedIPRangeLow IpAddress, -- sm24tat4xbExcludedIPRangeHigh IpAddress, -- sm24tat4xbExcludedIPRowStatus RowStatus -- } -- --sm24tat4xbExcludedIPIndex OBJECT-TYPE -- SYNTAX Integer32 (1..16) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Excluded IP table index, range: 1-16." -- ::= {sm24tat4xbExcludedIPEntry 1 } -- --sm24tat4xbExcludedIPRangeLow OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "ExcludedIP low range." -- ::= {sm24tat4xbExcludedIPEntry 2 } -- --sm24tat4xbExcludedIPRangeHigh OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "ExcludedIP high range." -- ::= {sm24tat4xbExcludedIPEntry 3 } -- --sm24tat4xbExcludedIPRowStatus OBJECT-TYPE -- SYNTAX RowStatus -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "This object indicates the status of this entry, and is -- used to create/delete entries. Any object in an entry of -- this table may be modified while the value of the -- corresponding instance of this object is active(1). -- createAndGo, notReady not supported." -- ::= {sm24tat4xbExcludedIPEntry 4 } -- -- -- --sm24tat4xbDHCPServerPoolConf OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 3 } -- --sm24tat4xbDHCPServerPoolTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBDHCPServerPoolEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This is the entry information for DHCP Pool." -- ::= { sm24tat4xbDHCPServerPoolConf 1 } -- --sm24tat4xbDHCPServerPoolEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBDHCPServerPoolEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- INDEX { sm24tat4xbDHCPServerConfIndex } -- ::= { sm24tat4xbDHCPServerPoolTable 1 } -- --SM24TAT4XBDHCPServerPoolEntry ::= SEQUENCE { -- sm24tat4xbDHCPServerConfIndex Integer32, -- sm24tat4xbDHCPServerPoolName DisplayString, -- sm24tat4xbDHCPServerPoolType Integer32, -- sm24tat4xbDHCPServerIP IpAddress, -- sm24tat4xbDHCPServerSubnetMask IpAddress, -- sm24tat4xbDHCPServerLeaseTimeDays Integer32, -- sm24tat4xbDHCPServerLeaseTimeHours Integer32, -- sm24tat4xbDHCPServerLeaseTimeMinutes Integer32, -- sm24tat4xbDHCPServerDomainName DisplayString, -- sm24tat4xbDHCPServerBroadcastAddress IpAddress, -- sm24tat4xbDHCPServerDefRouter1 IpAddress, -- sm24tat4xbDHCPServerDefRouter2 IpAddress, -- sm24tat4xbDHCPServerDefRouter3 IpAddress, -- sm24tat4xbDHCPServerDefRouter4 IpAddress, -- sm24tat4xbDHCPServerDNSServer1 IpAddress, -- sm24tat4xbDHCPServerDNSServer2 IpAddress, -- sm24tat4xbDHCPServerDNSServer3 IpAddress, -- sm24tat4xbDHCPServerDNSServer4 IpAddress, -- sm24tat4xbDHCPServerNTPServer1 IpAddress, -- sm24tat4xbDHCPServerNTPServer2 IpAddress, -- sm24tat4xbDHCPServerNTPServer3 IpAddress, -- sm24tat4xbDHCPServerNTPServer4 IpAddress, -- sm24tat4xbDHCPServerNetbiosType Integer32, -- sm24tat4xbDHCPServerNetbiosScope DisplayString, -- sm24tat4xbDHCPServerNetbiosNameServer1 IpAddress, -- sm24tat4xbDHCPServerNetbiosNameServer2 IpAddress, -- sm24tat4xbDHCPServerNetbiosNameServer3 IpAddress, -- sm24tat4xbDHCPServerNetbiosNameServer4 IpAddress, -- sm24tat4xbDHCPServerNisDomainName DisplayString, -- sm24tat4xbDHCPServerNisServer1 IpAddress, -- sm24tat4xbDHCPServerNisServer2 IpAddress, -- sm24tat4xbDHCPServerNisServer3 IpAddress, -- sm24tat4xbDHCPServerNisServer4 IpAddress, -- sm24tat4xbDHCPServerClientIDType Integer32, -- sm24tat4xbDHCPServerClientID DisplayString, -- sm24tat4xbDHCPServerHWAddr DisplayString, -- sm24tat4xbDHCPServerClientName DisplayString, -- sm24tat4xbDHCPServerVendorClassID1 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo1 DisplayString, -- sm24tat4xbDHCPServerVendorClassID2 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo2 DisplayString, -- sm24tat4xbDHCPServerVendorClassID3 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo3 DisplayString, -- sm24tat4xbDHCPServerVendorClassID4 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo4 DisplayString, -- sm24tat4xbDHCPServerVendorClassID5 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo5 DisplayString, -- sm24tat4xbDHCPServerVendorClassID6 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo6 DisplayString, -- sm24tat4xbDHCPServerVendorClassID7 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo7 DisplayString, -- sm24tat4xbDHCPServerVendorClassID8 DisplayString, -- sm24tat4xbDHCPServerVendorSpecificInfo8 DisplayString, -- sm24tat4xbDHCPServerRowStatus RowStatus --} -- --sm24tat4xbDHCPServerConfIndex OBJECT-TYPE -- SYNTAX Integer32 (1..64) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " pool, range : 1 - 64. " -- ::= { sm24tat4xbDHCPServerPoolEntry 1 } -- --sm24tat4xbDHCPServerPoolName OBJECT-TYPE -- SYNTAX DisplayString(SIZE (1..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP pool name. " -- ::= { sm24tat4xbDHCPServerPoolEntry 2 } -- --sm24tat4xbDHCPServerPoolType OBJECT-TYPE -- SYNTAX Integer32(0|1|2) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Pool Type. -- 0:None -- 1:Network -- 2:Host, please set DHCP Server IP first." -- ::= { sm24tat4xbDHCPServerPoolEntry 3 } -- --sm24tat4xbDHCPServerIP OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IP. " -- ::= { sm24tat4xbDHCPServerPoolEntry 4 } -- --sm24tat4xbDHCPServerSubnetMask OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Subnet Mask. " -- ::= { sm24tat4xbDHCPServerPoolEntry 5} -- --sm24tat4xbDHCPServerLeaseTimeDays OBJECT-TYPE -- SYNTAX Integer32(0..365) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Lease Time:Days. " -- ::= { sm24tat4xbDHCPServerPoolEntry 6 } -- --sm24tat4xbDHCPServerLeaseTimeHours OBJECT-TYPE -- SYNTAX Integer32(0..23) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Lease Time:Hours. " -- ::= { sm24tat4xbDHCPServerPoolEntry 7 } -- --sm24tat4xbDHCPServerLeaseTimeMinutes OBJECT-TYPE -- SYNTAX Integer32(0..59) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Lease Time:Minutes. " -- ::= { sm24tat4xbDHCPServerPoolEntry 8 } -- --sm24tat4xbDHCPServerDomainName OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..128)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Domain Name. " -- ::= { sm24tat4xbDHCPServerPoolEntry 9 } -- --sm24tat4xbDHCPServerBroadcastAddress OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Broadcast Address. " -- ::= { sm24tat4xbDHCPServerPoolEntry 10 } -- --sm24tat4xbDHCPServerDefRouter1 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Default Router 1. " -- ::= { sm24tat4xbDHCPServerPoolEntry 11 } -- --sm24tat4xbDHCPServerDefRouter2 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Default Router 2. " -- ::= { sm24tat4xbDHCPServerPoolEntry 12 } -- --sm24tat4xbDHCPServerDefRouter3 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Default Router 3. " -- ::= { sm24tat4xbDHCPServerPoolEntry 13 } -- --sm24tat4xbDHCPServerDefRouter4 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server IPv4 Default Router 4. " -- ::= { sm24tat4xbDHCPServerPoolEntry 14 } -- --sm24tat4xbDHCPServerDNSServer1 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server DNS Server 1. " -- ::= { sm24tat4xbDHCPServerPoolEntry 15 } -- --sm24tat4xbDHCPServerDNSServer2 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server DNS Server 2. " -- ::= { sm24tat4xbDHCPServerPoolEntry 16 } -- --sm24tat4xbDHCPServerDNSServer3 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server DNS Server 3. " -- ::= { sm24tat4xbDHCPServerPoolEntry 17 } -- --sm24tat4xbDHCPServerDNSServer4 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server DNS Server 4. " -- ::= { sm24tat4xbDHCPServerPoolEntry 18 } -- --sm24tat4xbDHCPServerNTPServer1 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server NTP Server 1. " -- ::= { sm24tat4xbDHCPServerPoolEntry 19 } -- --sm24tat4xbDHCPServerNTPServer2 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server NTP Server 2. " -- ::= { sm24tat4xbDHCPServerPoolEntry 20 } -- --sm24tat4xbDHCPServerNTPServer3 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server NTP Server 3. " -- ::= { sm24tat4xbDHCPServerPoolEntry 21 } -- --sm24tat4xbDHCPServerNTPServer4 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server NTP Server 4. " -- ::= { sm24tat4xbDHCPServerPoolEntry 22 } -- --sm24tat4xbDHCPServerNetbiosType OBJECT-TYPE -- SYNTAX Integer32(1..4) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Netbios Node Type. -- 0:None -- 1:B-node -- 2:P-node -- 3:M-node -- 4:H-node" -- ::= { sm24tat4xbDHCPServerPoolEntry 23 } -- --sm24tat4xbDHCPServerNetbiosScope OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..128)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Netbios Scope. " -- ::= { sm24tat4xbDHCPServerPoolEntry 24 } -- --sm24tat4xbDHCPServerNetbiosNameServer1 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Netbios Name Server 1. " -- ::= { sm24tat4xbDHCPServerPoolEntry 25 } -- --sm24tat4xbDHCPServerNetbiosNameServer2 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Netbios Name Server 2. " -- ::= { sm24tat4xbDHCPServerPoolEntry 26 } -- --sm24tat4xbDHCPServerNetbiosNameServer3 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Netbios Name Server 3. " -- ::= { sm24tat4xbDHCPServerPoolEntry 27 } -- --sm24tat4xbDHCPServerNetbiosNameServer4 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Netbios Name Server 4. " -- ::= { sm24tat4xbDHCPServerPoolEntry 28 } -- --sm24tat4xbDHCPServerNisDomainName OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..128)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Nis Domain Name. " -- ::= { sm24tat4xbDHCPServerPoolEntry 29 } -- --sm24tat4xbDHCPServerNisServer1 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Nis Server 1. " -- ::= { sm24tat4xbDHCPServerPoolEntry 30 } -- --sm24tat4xbDHCPServerNisServer2 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Nis Server 2. " -- ::= { sm24tat4xbDHCPServerPoolEntry 31 } -- --sm24tat4xbDHCPServerNisServer3 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Nis Server 3. " -- ::= { sm24tat4xbDHCPServerPoolEntry 32 } -- --sm24tat4xbDHCPServerNisServer4 OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Nis Server 4. " -- ::= { sm24tat4xbDHCPServerPoolEntry 33 } -- --sm24tat4xbDHCPServerClientIDType OBJECT-TYPE -- SYNTAX Integer32(0..2) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Client ID Type. -- 0:None -- 1:FQDN -- 2:MAC" -- ::= { sm24tat4xbDHCPServerPoolEntry 34 } -- --sm24tat4xbDHCPServerClientID OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..128)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Pool Client ID. " -- ::= { sm24tat4xbDHCPServerPoolEntry 35 } -- --sm24tat4xbDHCPServerHWAddr OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..17)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Pool Hardware Address. " -- ::= { sm24tat4xbDHCPServerPoolEntry 36 } -- --sm24tat4xbDHCPServerClientName OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Pool Client Name. " -- ::= { sm24tat4xbDHCPServerPoolEntry 37 } -- --sm24tat4xbDHCPServerVendorClassID1 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 1. Please also set VendorSpecificInfo1." -- ::= { sm24tat4xbDHCPServerPoolEntry 38 } -- --sm24tat4xbDHCPServerVendorSpecificInfo1 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 1. Please also set VendorClassID1." -- ::= { sm24tat4xbDHCPServerPoolEntry 39 } -- --sm24tat4xbDHCPServerVendorClassID2 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 2. Please also set VendorSpecificInfo2." -- ::= { sm24tat4xbDHCPServerPoolEntry 40 } -- --sm24tat4xbDHCPServerVendorSpecificInfo2 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 2. Please also set VendorClassID2." -- ::= { sm24tat4xbDHCPServerPoolEntry 41 } -- --sm24tat4xbDHCPServerVendorClassID3 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 3. Please also set VendorSpecificInfo3." -- ::= { sm24tat4xbDHCPServerPoolEntry 42 } -- --sm24tat4xbDHCPServerVendorSpecificInfo3 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 3. Please also set VendorClassID3." -- ::= { sm24tat4xbDHCPServerPoolEntry 43 } -- --sm24tat4xbDHCPServerVendorClassID4 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 4. Please also set VendorSpecificInfo4." -- ::= { sm24tat4xbDHCPServerPoolEntry 44 } -- --sm24tat4xbDHCPServerVendorSpecificInfo4 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 4. Please also set VendorClassID4." -- ::= { sm24tat4xbDHCPServerPoolEntry 45 } -- --sm24tat4xbDHCPServerVendorClassID5 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 5. Please also set VendorSpecificInfo5." -- ::= { sm24tat4xbDHCPServerPoolEntry 46 } -- --sm24tat4xbDHCPServerVendorSpecificInfo5 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 5. Please also set VendorClassID5." -- ::= { sm24tat4xbDHCPServerPoolEntry 47 } -- --sm24tat4xbDHCPServerVendorClassID6 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 6. Please also set VendorSpecificInfo6." -- ::= { sm24tat4xbDHCPServerPoolEntry 48 } -- --sm24tat4xbDHCPServerVendorSpecificInfo6 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 6. Please also set VendorClassID6." -- ::= { sm24tat4xbDHCPServerPoolEntry 49 } -- --sm24tat4xbDHCPServerVendorClassID7 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 7. Please also set VendorSpecificInfo7." -- ::= { sm24tat4xbDHCPServerPoolEntry 50 } -- --sm24tat4xbDHCPServerVendorSpecificInfo7 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 7. Please also set VendorClassID7." -- ::= { sm24tat4xbDHCPServerPoolEntry 51 } -- --sm24tat4xbDHCPServerVendorClassID8 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..64)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Class ID 8. Please also set VendorSpecificInfo8." -- ::= { sm24tat4xbDHCPServerPoolEntry 52 } -- --sm24tat4xbDHCPServerVendorSpecificInfo8 OBJECT-TYPE -- SYNTAX DisplayString(SIZE (0..32)) -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- " DHCP Server Vendor Specific Info 8. Please also set VendorClassID8." -- ::= { sm24tat4xbDHCPServerPoolEntry 53 } -- --sm24tat4xbDHCPServerRowStatus OBJECT-TYPE -- SYNTAX RowStatus -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "This object indicates the status of this entry, and is -- used to create/delete entries. Any object in an entry of -- this table may be modified while the value of the -- corresponding instance of this object is active(1). -- createAndGo, notReady not supported." -- ::= {sm24tat4xbDHCPServerPoolEntry 54 } -- --sm24tat4xbDHCPServerStatistics OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 4 } -- --sm24tat4xbDHCPServerStatisticsDatabaseCountersPool OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 1 } -- --sm24tat4xbDHCPServerStatisticsDatabaseCountersExcludedIPAddress OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 2 } -- --sm24tat4xbDHCPServerStatisticsDatabaseCountersDeclinedIPAddress OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 3 } -- --sm24tat4xbDHCPServerStatisticsBindingCountersAutomaticBinding OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 4 } -- --sm24tat4xbDHCPServerStatisticsBindingCountersManualBinding OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 5 } -- --sm24tat4xbDHCPServerStatisticsBindingCountersExpiredBinding OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 6 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageReceivedCountersDISCOVER OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 7 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageReceivedCountersREQUEST OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 8 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageReceivedCountersDECLINE OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 9 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageReceivedCountersRELEASE OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 10 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageReceivedCountersINFORM OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 11 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageSentCountersOFFER OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 12 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageSentCountersACK OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 13 } -- --sm24tat4xbDHCPServerStatisticsDHCPMessageSentCountersNAK OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 14 } -- --sm24tat4xbDHCPServerClear OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- " -- " -- ::= { sm24tat4xbDHCPServerStatistics 15 } -- --sm24tat4xbDHCPServerBinding OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 5 } -- --sm24tat4xbDHCPServerBindingTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBDHCPServerBindingEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBinding 1 } -- --sm24tat4xbDHCPServerBindingEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBDHCPServerBindingEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- INDEX { sm24tat4xbDHCPServerBindingIndex } -- ::= { sm24tat4xbDHCPServerBindingTable 1 } -- --SM24TAT4XBDHCPServerBindingEntry ::= SEQUENCE { -- sm24tat4xbDHCPServerBindingIndex Integer32, -- sm24tat4xbDHCPServerBindingIP DisplayString, -- sm24tat4xbDHCPServerBindingType DisplayString, -- sm24tat4xbDHCPServerBindingState DisplayString, -- sm24tat4xbDHCPServerBindingPoolName DisplayString, -- sm24tat4xbDHCPServerBindingServerID DisplayString, -- sm24tat4xbDHCPServerBindingVLAN Integer32, -- sm24tat4xbDHCPServerBindingSubnetMask DisplayString, -- sm24tat4xbDHCPServerBindingClientIDType DisplayString, -- sm24tat4xbDHCPServerBindingClientIDValue DisplayString, -- sm24tat4xbDHCPServerBindingMACAddress DisplayString, -- sm24tat4xbDHCPServerBindingLeaseTime DisplayString, -- sm24tat4xbDHCPServerBindingWillExpiredIn DisplayString, -- sm24tat4xbDHCPServerBindingDelete Integer32 --} -- --sm24tat4xbDHCPServerBindingIndex OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Index" -- ::= { sm24tat4xbDHCPServerBindingEntry 1 } -- --sm24tat4xbDHCPServerBindingIP OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 2 } -- --sm24tat4xbDHCPServerBindingType OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 3 } -- --sm24tat4xbDHCPServerBindingState OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 4 } -- --sm24tat4xbDHCPServerBindingPoolName OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 5 } -- --sm24tat4xbDHCPServerBindingServerID OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 6 } -- --sm24tat4xbDHCPServerBindingVLAN OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 7 } -- --sm24tat4xbDHCPServerBindingSubnetMask OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 8 } -- --sm24tat4xbDHCPServerBindingClientIDType OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 9 } -- --sm24tat4xbDHCPServerBindingClientIDValue OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 10 } -- --sm24tat4xbDHCPServerBindingMACAddress OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 11 } -- --sm24tat4xbDHCPServerBindingLeaseTime OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 12 } -- --sm24tat4xbDHCPServerBindingWillExpiredIn OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 13 } -- --sm24tat4xbDHCPServerBindingDelete OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerBindingEntry 14 } -- --sm24tat4xbDHCPServerBindingClearAutomatic OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "1:clear" -- ::= { sm24tat4xbDHCPServerBinding 2 } -- --sm24tat4xbDHCPServerBindingClearManual OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "1:clear" -- ::= { sm24tat4xbDHCPServerBinding 3 } -- --sm24tat4xbDHCPServerBindingClearExpired OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "1:clear" -- ::= { sm24tat4xbDHCPServerBinding 4 } -- --sm24tat4xbDHCPServerDeclined OBJECT IDENTIFIER ::= { sm24tat4xbDHCPServer 6 } -- --sm24tat4xbDHCPServerDeclinedTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBDHCPServerDeclinedEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerDeclined 1 } -- --sm24tat4xbDHCPServerDeclinedEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBDHCPServerDeclinedEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- INDEX { sm24tat4xbDHCPServerDeclinedIndex } -- ::= { sm24tat4xbDHCPServerDeclinedTable 1 } -- --SM24TAT4XBDHCPServerDeclinedEntry ::= SEQUENCE { -- sm24tat4xbDHCPServerDeclinedIndex Integer32, -- sm24tat4xbDHCPServerDeclinedIP DisplayString --} -- --sm24tat4xbDHCPServerDeclinedIndex OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Index" -- ::= { sm24tat4xbDHCPServerDeclinedEntry 1 } -- --sm24tat4xbDHCPServerDeclinedIP OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbDHCPServerDeclinedEntry 2 } -- ======================================================================================================================= sm24tat4xbVLANConf OBJECT IDENTIFIER ::= { sm24tat4xbSystem 10 } sm24tat4xbVLAN OBJECT IDENTIFIER ::= { sm24tat4xbVLANConf 2} sm24tat4xbVlanStatus OBJECT IDENTIFIER ::= { sm24tat4xbVLAN 6 } -- -- ======================================================================================================================= -- Start sm24tat4xbVlan group -- ======================================================================================================================= sm24tat4xbVlanExistingVLANs OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This field shows the VLANs that are created on the switch. More VLANs may be created by using a list syntax where the individual elements are separated by commas. Ranges are specified with a dash separating the lower and upper bound. The following example will create VLANs 1, 10, 11, 12 , 13, 200, and 300: 1,10-13,200,300. default: 1." ::= { sm24tat4xbVLAN 1 } sm24tat4xbVlanEthertypeforCustomSPorts OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This field specifies the ethertype/TPID (specified in hexadecimal) used for Custom S-ports. The setting is in force for all ports whose Port Type is set to S-Custom-Port. range: 0600-ffff, default: 88a8." ::= { sm24tat4xbVLAN 2 } sm24tat4xbVlanTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configure Vlan ports Configuration mode. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbVLAN 3 } sm24tat4xbVlanEntry OBJECT-TYPE SYNTAX SM24TAT4XBVlanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Vlan entry." INDEX { ifIndex } ::= { sm24tat4xbVlanTable 1 } SM24TAT4XBVlanEntry ::= SEQUENCE { sm24tat4xbVlanMode INTEGER, sm24tat4xbVlanPortVLAN Integer32, sm24tat4xbVlanPortType INTEGER, sm24tat4xbVlanIngressFiltering AdminMode, -- sm24tat4xbVlanVLANTrunking AdminMode, sm24tat4xbVlanIngressAcceptance INTEGER, sm24tat4xbVlanEgressTagging INTEGER, sm24tat4xbVlanAllowedVLANs DisplayString, sm24tat4xbVlanForbiddenVLANs DisplayString } sm24tat4xbVlanMode OBJECT-TYPE SYNTAX INTEGER{access(0), trunk(1), hybrid(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "The port mode determines the fundamental behavior of the port in question. A port can be in one of three modes as described below. 0: access, 1: trunk, 2: hybrid." DEFVAL { access } ::= { sm24tat4xbVlanEntry 2 } sm24tat4xbVlanPortVLAN OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the port's VLAN ID (a.k.a. PVID). range: 1-4095, default: 1." ::= { sm24tat4xbVlanEntry 3 } sm24tat4xbVlanPortType OBJECT-TYPE SYNTAX INTEGER { unaware(0), cPort(1), sPort(2), sCustomPort(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ports in hybrid mode allow for changing the port type, that is, whether a frame's VLAN tag is used to classify the frame on ingress to a particular VLAN, and if so, which TPID it reacts on. Likewise, on egress, the Port Type determines the TPID of the tag, if a tag is required. 0: unaware, 1: c-Port, 2: s-Port, 3: s-Custom-Port." DEFVAL { cPort } ::= { sm24tat4xbVlanEntry 4 } sm24tat4xbVlanIngressFiltering OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Hybrid ports allow for changing ingress filtering. Access and Trunk ports always have ingress filtering enabled.If ingress filtering is enabled, frames classified to a VLAN that the port is not a member of get discarded." ::= { sm24tat4xbVlanEntry 5 } -- sm24tat4xbVlanVLANTrunking OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Trunk and Hybrid ports allow for enabling VLAN trunking. -- When VLAN trunking is enabled, frames -- classified to unknown VLANs are accepted on the port -- whether ingress filtering is enabled or not." -- DEFVAL { disable } -- ::= { sm24tat4xbVlanEntry 6 } sm24tat4xbVlanIngressAcceptance OBJECT-TYPE SYNTAX INTEGER { taggedAndUntagged ( 0 ), taggedOnly ( 1 ), untaggedOnly ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Hybrid ports allow for changing the type of frames that are accepted on ingress. 0: Tagged and Untagged, 1: Tagged Only, 2: Untagged Only." ::= { sm24tat4xbVlanEntry 7 } sm24tat4xbVlanEgressTagging OBJECT-TYPE SYNTAX INTEGER { untagPortVlan ( 0 ), tagAll ( 1 ), untagAll ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Ports in Trunk and Hybrid mode may control the tagging of frames on egress. 0: Untag Port VLAN, 1: Tag All, 2: Untag All." ::= { sm24tat4xbVlanEntry 8 } sm24tat4xbVlanAllowedVLANs OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Ports in Trunk and Hybrid mode may control which VLANs they are allowed to become members of. Access ports can only be member of one VLAN, the Access VLAN. range: 1~4095. '-': Allowed VLANs is empty." ::= { sm24tat4xbVlanEntry 9 } sm24tat4xbVlanForbiddenVLANs OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A port may be configured to never be member of one or more VLANs. This is particularly useful when dynamic VLAN protocols like MVRP and GVRP must be prevented from dynamically adding ports to VLANs. range: 1~4095. '-': Forbidden VLANs is empty." ::= { sm24tat4xbVlanEntry 10 } --sm24tat4xbVLANMembershipStatusTable sm24tat4xbVLANMembershipStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANMembershipStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Vlan membership Status table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbVlanStatus 1 } sm24tat4xbVLANMembershipStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANMembershipStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Vlan membership Status entry." INDEX { ifIndex, sm24tat4xbVLANMembershipVlanID } ::= { sm24tat4xbVLANMembershipStatusTable 1 } SM24TAT4XBVLANMembershipStatusEntry ::= SEQUENCE { sm24tat4xbVLANMembershipVlanID Integer32, sm24tat4xbVLANMembershipStatus INTEGER } sm24tat4xbVLANMembershipVlanID OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN ID for which the Port members are displayed." ::= { sm24tat4xbVLANMembershipStatusEntry 2 } sm24tat4xbVLANMembershipStatus OBJECT-TYPE SYNTAX INTEGER { portIsNotInVlan ( 0 ), portIncludedInVlan ( 1 ), portInForbiddenPortList( 2 ), portInForbiddenPortListAndVlan( 3 ) } MAX-ACCESS read-only STATUS current DESCRIPTION "portIsNotInVlan(0): A port is nothing in a VLAN. portIncludedInVlan(1): A port is included in a VLAN. portInForbiddenPortList(2): A port is in the forbidden port list. portInForbiddenPortListAndVlan(3): A port is in the forbidden port list and at the same time attempted included in the VLAN." ::= { sm24tat4xbVLANMembershipStatusEntry 3 } --sm24tat4xbVLANPortStatusTable sm24tat4xbVLANPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The vlan port status table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbVlanStatus 2 } sm24tat4xbVLANPortStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The vlan port status entry." INDEX { ifIndex } ::= { sm24tat4xbVLANPortStatusTable 1 } SM24TAT4XBVLANPortStatusEntry ::= SEQUENCE { sm24tat4xbVLANPortStatusPortType DisplayString, sm24tat4xbVLANPortStatusIngressFiltering AdminMode, sm24tat4xbVLANPortStatusFrameType DisplayString, sm24tat4xbVLANPortStatusPortVLANID Integer32, sm24tat4xbVLANPortStatusTxTag DisplayString, sm24tat4xbVLANPortStatusUntaggedVLANID Integer32, sm24tat4xbVLANPortStatusConflicts DisplayString } sm24tat4xbVLANPortStatusPortType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the port type (Unaware, C-Port, S-Port, S-Custom-Port.) that a given user wants to configure on the port.The field is empty if not overridden by the selected user." ::= { sm24tat4xbVLANPortStatusEntry 2 } sm24tat4xbVLANPortStatusIngressFiltering OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-only STATUS current DESCRIPTION "Shows whether a given user wants ingress filtering enabled or not." ::= { sm24tat4xbVLANPortStatusEntry 3 } sm24tat4xbVLANPortStatusFrameType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the acceptable frame types (All, Taged, Untagged) that a given user wants to configure on the port. The field is empty if not overridden by the selected user." ::= { sm24tat4xbVLANPortStatusEntry 4 } sm24tat4xbVLANPortStatusPortVLANID OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Port VLAN ID (PVID) that a given user wants the port to have. The field is 0 if not overridden by the selected user." ::= { sm24tat4xbVLANPortStatusEntry 5 } sm24tat4xbVLANPortStatusTxTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the Tx Tag requirements (Tag All, Tag PVID, Tag UVID, Untag All, Untag PVID, Untag UVID) that a given user has on a port.The field is empty if not overridden by the selected user." ::= { sm24tat4xbVLANPortStatusEntry 6 } sm24tat4xbVLANPortStatusUntaggedVLANID OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "If Tx Tag is overridden by the selected user and is set to Tag or Untag UVID, then this field will show the VLAN ID the user wants to tag or untag on egress. The field is 0 if not overridden by the selected user." ::= { sm24tat4xbVLANPortStatusEntry 7 } sm24tat4xbVLANPortStatusConflicts OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Two users may have conflicting requirements to a port's configuration. For instance, one user may require all frames to be tagged on egress while another requires all frames to be untagged on egress.Since both users cannot win, this gives rise to a conflict, which is solved in a prioritized way. The Administrator has the least priority. Other software modules are prioritized according to their position in the drop-down list: The higher in the list, the higher priority. If conflicts exist, it will be displayed as 'Yes'." ::= { sm24tat4xbVLANPortStatusEntry 8 } sm24tat4xbMacBaesdVlanMembershipConfig OBJECT IDENTIFIER ::= { sm24tat4xbVLAN 7 } sm24tat4xbMacBaesdVlanMembershipConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMacBaesdVlanMembershipConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mac-Based VLAN Membership table" ::= { sm24tat4xbMacBaesdVlanMembershipConfig 1 } sm24tat4xbMacBaesdVlanMembershipConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBMacBaesdVlanMembershipConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mac-Based VLAN Membership table." INDEX { sm24tat4xbMacBaesdVlanMembershipConfigIndex } ::= { sm24tat4xbMacBaesdVlanMembershipConfigTable 1 } SM24TAT4XBMacBaesdVlanMembershipConfigEntry ::= SEQUENCE { sm24tat4xbMacBaesdVlanMembershipConfigIndex Integer32, sm24tat4xbMacBaesdVlanMembershipConfigMACAddress DisplayString, sm24tat4xbMacBaesdVlanMembershipConfigVLANID Integer32, sm24tat4xbMacBaesdVlanMembershipConfigPortMembers DisplayString, sm24tat4xbMacBaesdVlanMembershipConfigRowStatus RowStatus } sm24tat4xbMacBaesdVlanMembershipConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mac-Based VLAN membership index." ::= {sm24tat4xbMacBaesdVlanMembershipConfigEntry 1 } sm24tat4xbMacBaesdVlanMembershipConfigMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "MAC address: xx-xx-xx-xx-xx-xx." ::= {sm24tat4xbMacBaesdVlanMembershipConfigEntry 2 } sm24tat4xbMacBaesdVlanMembershipConfigVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID" ::= {sm24tat4xbMacBaesdVlanMembershipConfigEntry 3 } sm24tat4xbMacBaesdVlanMembershipConfigPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "0:remove or exclude the port from the mapping 1:include a port in the mapping" ::= {sm24tat4xbMacBaesdVlanMembershipConfigEntry 4 } sm24tat4xbMacBaesdVlanMembershipConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbMacBaesdVlanMembershipConfigEntry 5 } sm24tat4xbMacBaesdVlanMembershipStatusUser OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MAC-based VLAN Membership Status User" ::= { sm24tat4xbVLAN 8 } sm24tat4xbMacBaesdVlanMembershipStatus OBJECT IDENTIFIER ::= { sm24tat4xbVLAN 9 } sm24tat4xbMacBaesdVlanMembershipStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMacBaesdVlanMembershipStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mac-Based VLAN Membership table" ::= { sm24tat4xbMacBaesdVlanMembershipStatus 1 } sm24tat4xbMacBaesdVlanMembershipStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBMacBaesdVlanMembershipStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mac-Based VLAN Membership table." INDEX { sm24tat4xbMacBaesdVlanMembershipStatusIndex } ::= { sm24tat4xbMacBaesdVlanMembershipStatusTable 1 } SM24TAT4XBMacBaesdVlanMembershipStatusEntry ::= SEQUENCE { sm24tat4xbMacBaesdVlanMembershipStatusIndex Integer32, sm24tat4xbMacBaesdVlanMembershipStatusMACAddress DisplayString, sm24tat4xbMacBaesdVlanMembershipStatusVLANID Integer32, sm24tat4xbMacBaesdVlanMembershipStatusPortMembers DisplayString } sm24tat4xbMacBaesdVlanMembershipStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Mac-Based VLAN membership index." ::= {sm24tat4xbMacBaesdVlanMembershipStatusEntry 1 } sm24tat4xbMacBaesdVlanMembershipStatusMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address: xx-xx-xx-xx-xx-xx." ::= {sm24tat4xbMacBaesdVlanMembershipStatusEntry 2 } sm24tat4xbMacBaesdVlanMembershipStatusVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= {sm24tat4xbMacBaesdVlanMembershipStatusEntry 3 } sm24tat4xbMacBaesdVlanMembershipStatusPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "0:remove or exclude the port from the mapping 1:include a port in the mapping" ::= {sm24tat4xbMacBaesdVlanMembershipStatusEntry 4 } sm24tat4xbProtocolbasedVLANConfig OBJECT IDENTIFIER ::= { sm24tat4xbVLAN 10 } sm24tat4xbProtocolbasedVLANConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBProtocolbasedVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Protocol-based VLAN Config table" ::= { sm24tat4xbProtocolbasedVLANConfig 1 } sm24tat4xbProtocolbasedVLANConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBProtocolbasedVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Protocol-based VLAN Config table" INDEX { sm24tat4xbProtocolbasedVLANConfigIndex } ::= { sm24tat4xbProtocolbasedVLANConfigTable 1 } SM24TAT4XBProtocolbasedVLANConfigEntry ::= SEQUENCE { sm24tat4xbProtocolbasedVLANConfigIndex Integer32, sm24tat4xbProtocolbasedVLANConfigFrameType Integer32, sm24tat4xbProtocolbasedVLANConfigValueEthernetEtype DisplayString, sm24tat4xbProtocolbasedVLANConfigValueSNAPOUI DisplayString, sm24tat4xbProtocolbasedVLANConfigValueSNAPPID DisplayString, sm24tat4xbProtocolbasedVLANConfigValueLLCDSAP DisplayString, sm24tat4xbProtocolbasedVLANConfigValueLLCSSAP DisplayString, sm24tat4xbProtocolbasedVLANConfigGroupName DisplayString, sm24tat4xbProtocolbasedVLANConfigRowStatus RowStatus } sm24tat4xbProtocolbasedVLANConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Protocol-based VLAN Config index." ::= {sm24tat4xbProtocolbasedVLANConfigEntry 1 } sm24tat4xbProtocolbasedVLANConfigFrameType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Frame Type. 1:Ethernet 2:LLC 3:SNAP" ::= {sm24tat4xbProtocolbasedVLANConfigEntry 2 } sm24tat4xbProtocolbasedVLANConfigValueEthernetEtype OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Ethernet Etype. Valid values for etype range between 0x0600 and 0xffff " ::= {sm24tat4xbProtocolbasedVLANConfigEntry 3 } sm24tat4xbProtocolbasedVLANConfigValueSNAPOUI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "SNAP OUI. Format:xx-xx-xx" ::= {sm24tat4xbProtocolbasedVLANConfigEntry 4 } sm24tat4xbProtocolbasedVLANConfigValueSNAPPID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "SNAP PID Ranging between 0x00 and 0xff." ::= {sm24tat4xbProtocolbasedVLANConfigEntry 5 } sm24tat4xbProtocolbasedVLANConfigValueLLCDSAP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "LLC DSAP. Range: 0x00-0xff" ::= {sm24tat4xbProtocolbasedVLANConfigEntry 6 } sm24tat4xbProtocolbasedVLANConfigValueLLCSSAP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "LLC SSAP. Range: 0x00-0xff" ::= {sm24tat4xbProtocolbasedVLANConfigEntry 7 } sm24tat4xbProtocolbasedVLANConfigGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Group Name 16-character long string, unique for every entry, which consists of a combination of alphabets (a-z or A-Z) and integers(0-9)." ::= {sm24tat4xbProtocolbasedVLANConfigEntry 8 } sm24tat4xbProtocolbasedVLANConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbProtocolbasedVLANConfigEntry 9 } sm24tat4xbGroupNameToVLANMappingConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBGroupNameToVLANMappingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group Name To VLAN Mapping Config table" ::= { sm24tat4xbProtocolbasedVLANConfig 2 } sm24tat4xbGroupNameToVLANMappingConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBGroupNameToVLANMappingConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group Name To VLAN Mapping Config table." INDEX { sm24tat4xbGroupNameToVLANMappingConfigIndex } ::= { sm24tat4xbGroupNameToVLANMappingConfigTable 1 } SM24TAT4XBGroupNameToVLANMappingConfigEntry ::= SEQUENCE { sm24tat4xbGroupNameToVLANMappingConfigIndex Integer32, sm24tat4xbGroupNameToVLANMappingConfigGroupName DisplayString, sm24tat4xbGroupNameToVLANMappingConfigVLANID Integer32, sm24tat4xbGroupNameToVLANMappingConfigPortMembers DisplayString, sm24tat4xbGroupNameToVLANMappingConfigRowStatus RowStatus } sm24tat4xbGroupNameToVLANMappingConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Group Name To VLAN Mapping Config index." ::= {sm24tat4xbGroupNameToVLANMappingConfigEntry 1 } sm24tat4xbGroupNameToVLANMappingConfigGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Group Name 16-character long string, unique for every entry, which consists of a combination of alphabets (a-z or A-Z) and integers(0-9)." ::= {sm24tat4xbGroupNameToVLANMappingConfigEntry 2 } sm24tat4xbGroupNameToVLANMappingConfigVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID" ::= {sm24tat4xbGroupNameToVLANMappingConfigEntry 3 } sm24tat4xbGroupNameToVLANMappingConfigPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "0:remove or exclude the port from the mapping 1:include a port in the mapping" ::= {sm24tat4xbGroupNameToVLANMappingConfigEntry 4 } sm24tat4xbGroupNameToVLANMappingConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbGroupNameToVLANMappingConfigEntry 5 } sm24tat4xbIPSubnetBasedVLANConfig OBJECT IDENTIFIER ::= { sm24tat4xbVLAN 11 } sm24tat4xbIPSubnetBasedVLANConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPSubnetBasedVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP Subnet Based VLAN Config table" ::= { sm24tat4xbIPSubnetBasedVLANConfig 1 } sm24tat4xbIPSubnetBasedVLANConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPSubnetBasedVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP Subnet Based VLAN Config table." INDEX { sm24tat4xbIPSubnetBasedVLANConfigIndex } ::= { sm24tat4xbIPSubnetBasedVLANConfigTable 1 } SM24TAT4XBIPSubnetBasedVLANConfigEntry ::= SEQUENCE { sm24tat4xbIPSubnetBasedVLANConfigIndex Integer32, sm24tat4xbIPSubnetBasedVLANConfigIPAddress IpAddress, sm24tat4xbIPSubnetBasedVLANConfigMaskLength Integer32, sm24tat4xbIPSubnetBasedVLANConfigVLANID Integer32, sm24tat4xbIPSubnetBasedVLANConfigPortMembers DisplayString, sm24tat4xbIPSubnetBasedVLANConfigRowStatus RowStatus } sm24tat4xbIPSubnetBasedVLANConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "IP Subnet Based VLAN Config index." ::= {sm24tat4xbIPSubnetBasedVLANConfigEntry 1 } sm24tat4xbIPSubnetBasedVLANConfigIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The subnet's IP address" ::= {sm24tat4xbIPSubnetBasedVLANConfigEntry 2 } sm24tat4xbIPSubnetBasedVLANConfigMaskLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The subnet's mask length. " ::= {sm24tat4xbIPSubnetBasedVLANConfigEntry 3 } sm24tat4xbIPSubnetBasedVLANConfigVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID" ::= {sm24tat4xbIPSubnetBasedVLANConfigEntry 4 } sm24tat4xbIPSubnetBasedVLANConfigPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "0:remove or exclude the port from the mapping 1:include a port in the mapping" ::= {sm24tat4xbIPSubnetBasedVLANConfigEntry 5 } sm24tat4xbIPSubnetBasedVLANConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbIPSubnetBasedVLANConfigEntry 6 } sm24tat4xbVLANNameConfig OBJECT IDENTIFIER ::= { sm24tat4xbVLAN 12 } sm24tat4xbVLANNameConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANNameConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN Name Config table" ::= { sm24tat4xbVLANNameConfig 1 } sm24tat4xbVLANNameConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANNameConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN Name Config table." INDEX { sm24tat4xbVLANNameConfigIndex } ::= { sm24tat4xbVLANNameConfigTable 1 } SM24TAT4XBVLANNameConfigEntry ::= SEQUENCE { sm24tat4xbVLANNameConfigIndex Integer32, sm24tat4xbVLANNameConfigVLANName DisplayString } sm24tat4xbVLANNameConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN Name Config index." ::= {sm24tat4xbVLANNameConfigEntry 1 } sm24tat4xbVLANNameConfigVLANName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "VLAN Name." ::= {sm24tat4xbVLANNameConfigEntry 2 } sm24tat4xbNTPConf OBJECT IDENTIFIER ::= { sm24tat4xbSystem 12 } sm24tat4xbNTPConfigMode OBJECT-TYPE SYNTAX INTEGER {useLocal(0),useNTP(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "The system NTP Mode. useLocal(0) : Use Local Settings, useNTP(1) : Use NTP Server." DEFVAL { useLocal } ::= { sm24tat4xbNTPConf 1 } --sm24tat4xbNTPConfigAutomatic OBJECT-TYPE -- SYNTAX Integer32 (0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Indicates the Automatic mode operation. Possible modes are: -- 0:Disable, NTP servers available from the config. -- 1:Enable, NTP servers available from the DHCP." -- ::= { sm24tat4xbNTPConf 2 } sm24tat4xbNTPConfigTimeSyncInterval OBJECT-TYPE SYNTAX Integer32 (5|10|15|30|60|120) MAX-ACCESS read-write STATUS current DESCRIPTION "Time-Sync Interval. Valid values are restricted to 5,10,15,30,60,120 minutes. " ::= { sm24tat4xbNTPConf 3 } sm24tat4xbNTPConfigServerAddress1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Provide the IPv4 or IPv6 address of a NTP server." ::= { sm24tat4xbNTPConf 4 } sm24tat4xbNTPConfigServerAddress2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Provide the IPv4 or IPv6 address of a NTP server." ::= { sm24tat4xbNTPConf 5 } sm24tat4xbNTPConfigServerAddress3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Provide the IPv4 or IPv6 address of a NTP server." ::= { sm24tat4xbNTPConf 6 } sm24tat4xbNTPConfigServerAddress4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Provide the IPv4 or IPv6 address of a NTP server." ::= { sm24tat4xbNTPConf 7 } sm24tat4xbNTPConfigServerAddress5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Provide the IPv4 or IPv6 address of a NTP server." ::= { sm24tat4xbNTPConf 8 } sm24tat4xbTemperature OBJECT IDENTIFIER ::= { sm24tat4xbSystem 13 } sm24tat4xbTemperature1 OBJECT IDENTIFIER ::= { sm24tat4xbTemperature 1 } sm24tat4xbTemperature1Celsius OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Celsius" ::= { sm24tat4xbTemperature1 1 } sm24tat4xbTemperature1Fahrenheit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Fahrenheit" ::= { sm24tat4xbTemperature1 2 } sm24tat4xbTemperature2 OBJECT IDENTIFIER ::= { sm24tat4xbTemperature 2 } sm24tat4xbTemperature2Celsius OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Celsius" ::= { sm24tat4xbTemperature2 1 } sm24tat4xbTemperature2Fahrenheit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Fahrenheit" ::= { sm24tat4xbTemperature2 2 } -- ======================================================================================================================= sm24tat4xbConfiguration OBJECT IDENTIFIER ::= { sm24tat4xbProductId 2 } sm24tat4xbPort OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 1 } sm24tat4xbPortConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPortConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Show port configurations. " ::= { sm24tat4xbPort 1 } sm24tat4xbPortConfigurationEntry OBJECT-TYPE SYNTAX SM24TAT4XBPortConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPortConfPort } ::= { sm24tat4xbPortConfigurationTable 1 } SM24TAT4XBPortConfigurationEntry ::= SEQUENCE { sm24tat4xbPortConfPort Integer32, sm24tat4xbPortConfDescription DisplayString, sm24tat4xbPortConfLink DisplayString, sm24tat4xbPortConfSpeedStatus DisplayString, sm24tat4xbPortConfSpeedMode Integer32, sm24tat4xbPortConfFlowControlRxStatus Integer32, sm24tat4xbPortConfFlowControlTxStatus Integer32, sm24tat4xbPortConfFlowControlMode Integer32, sm24tat4xbPortConfMaximumFrameSize Integer32 -- sm24tat4xbPortConfExcessiveCollisionMode Integer32, -- sm24tat4xbPortConfPowerControl Integer32, -- sm24tat4xbPortConfPortMedia DisplayString } sm24tat4xbPortConfPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbPortConfigurationEntry 1 } sm24tat4xbPortConfDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Interface specific description. Up to 16 characters describing this interface. " ::= { sm24tat4xbPortConfigurationEntry 2 } sm24tat4xbPortConfLink OBJECT-TYPE SYNTAX DisplayString(SIZE (2..4)) MAX-ACCESS read-only STATUS current DESCRIPTION " The current link state. " ::= { sm24tat4xbPortConfigurationEntry 3 } sm24tat4xbPortConfSpeedStatus OBJECT-TYPE SYNTAX DisplayString(SIZE (6..12)) MAX-ACCESS read-only STATUS current DESCRIPTION " The current link speed of the port. " ::= { sm24tat4xbPortConfigurationEntry 4 } sm24tat4xbPortConfSpeedMode OBJECT-TYPE SYNTAX Integer32 (0..9) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 1, 0: disable state, 1: auto, 2: 10 Half, 3: 10 Full, 4: 100 Half, 5: 100 Full, 6: 1G full, 7: 10G Full, 8: 100-FX, 9: 1000-X. " ::= { sm24tat4xbPortConfigurationEntry 5 } sm24tat4xbPortConfFlowControlRxStatus OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-only STATUS current DESCRIPTION "0: disable 1: enable 2: not support. " ::= { sm24tat4xbPortConfigurationEntry 6 } sm24tat4xbPortConfFlowControlTxStatus OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-only STATUS current DESCRIPTION "0: disable 1: enable 2: not support. " ::= { sm24tat4xbPortConfigurationEntry 7 } sm24tat4xbPortConfFlowControlMode OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0, 0: disable 1: enable 2: not support. " ::= { sm24tat4xbPortConfigurationEntry 8 } sm24tat4xbPortConfMaximumFrameSize OBJECT-TYPE SYNTAX Integer32 (1518..10240) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 10240 , range : 1518 - 10240 " ::= { sm24tat4xbPortConfigurationEntry 9 } --sm24tat4xbPortConfExcessiveCollisionMode OBJECT-TYPE -- SYNTAX Integer32 (0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0, -- Excessive Collision Mode : -- 0: Discard, -- 1: Restart, -- 2: not support. -- " -- ::= { sm24tat4xbPortConfigurationEntry 10 } --sm24tat4xbPortConfPowerControl OBJECT-TYPE -- SYNTAX Integer32 (0..3) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0, -- PowerControl : -- 0: disable, -- 1: Actiphy, -- 2: Dynamic (perfectReach), -- 3: Enable, -- 4: not support. -- " -- ::= { sm24tat4xbPortConfigurationEntry 11 } --sm24tat4xbPortConfPortMedia OBJECT-TYPE -- SYNTAX DisplayString(SIZE (1..4)) -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " Show port media. " -- ::= { sm24tat4xbPortConfigurationEntry 12 } sm24tat4xbPortTrafficStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPortTrafficStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPort 2 } sm24tat4xbPortTrafficStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBPortTrafficStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPortTrafficStatisticsPort } ::= { sm24tat4xbPortTrafficStatisticsTable 1 } SM24TAT4XBPortTrafficStatisticsEntry ::= SEQUENCE { sm24tat4xbPortTrafficStatisticsPort Integer32, sm24tat4xbPortTrafficStatisticsClear Integer32, sm24tat4xbPortTrafficRxPackets Counter64, sm24tat4xbPortTrafficRxOctets Counter64, sm24tat4xbPortTrafficRxUnicast Counter64, sm24tat4xbPortTrafficRxMulticast Counter64, sm24tat4xbPortTrafficRxBroadcast Counter64, sm24tat4xbPortTrafficRxPause Counter64, sm24tat4xbPortTrafficRx64Bytes Counter64, sm24tat4xbPortTrafficRx65to127Bytes Counter64, sm24tat4xbPortTrafficRx128to255Bytes Counter64, sm24tat4xbPortTrafficRx256to511Bytes Counter64, sm24tat4xbPortTrafficRx512to1023Bytes Counter64, sm24tat4xbPortTrafficRx1024to1526Bytes Counter64, sm24tat4xbPortTrafficRxExceecd1527Bytes Counter64, sm24tat4xbPortTrafficRxQ0 Counter64, sm24tat4xbPortTrafficRxQ1 Counter64, sm24tat4xbPortTrafficRxQ2 Counter64, sm24tat4xbPortTrafficRxQ3 Counter64, sm24tat4xbPortTrafficRxQ4 Counter64, sm24tat4xbPortTrafficRxQ5 Counter64, sm24tat4xbPortTrafficRxQ6 Counter64, sm24tat4xbPortTrafficRxQ7 Counter64, sm24tat4xbPortTrafficRxDrops Counter64, sm24tat4xbPortTrafficRxCRCorAlignment Counter64, sm24tat4xbPortTrafficRxUndersize Counter64, sm24tat4xbPortTrafficRxOversize Counter64, sm24tat4xbPortTrafficRxFragments Counter64, sm24tat4xbPortTrafficRxJabber Counter64, sm24tat4xbPortTrafficRxFiltered Counter64, sm24tat4xbPortTrafficTxPackets Counter64, sm24tat4xbPortTrafficTxOctets Counter64, sm24tat4xbPortTrafficTxUnicast Counter64, sm24tat4xbPortTrafficTxMulticast Counter64, sm24tat4xbPortTrafficTxBroadcast Counter64, sm24tat4xbPortTrafficTxPause Counter64, sm24tat4xbPortTrafficTx64Bytes Counter64, sm24tat4xbPortTrafficTx65to127Bytes Counter64, sm24tat4xbPortTrafficTx128to255Bytes Counter64, sm24tat4xbPortTrafficTx256to511Bytes Counter64, sm24tat4xbPortTrafficTx512to1023Bytes Counter64, sm24tat4xbPortTrafficTx1024to1526Bytes Counter64, sm24tat4xbPortTrafficTxExceecd1527Bytes Counter64, sm24tat4xbPortTrafficTxQ0 Counter64, sm24tat4xbPortTrafficTxQ1 Counter64, sm24tat4xbPortTrafficTxQ2 Counter64, sm24tat4xbPortTrafficTxQ3 Counter64, sm24tat4xbPortTrafficTxQ4 Counter64, sm24tat4xbPortTrafficTxQ5 Counter64, sm24tat4xbPortTrafficTxQ6 Counter64, sm24tat4xbPortTrafficTxQ7 Counter64, sm24tat4xbPortTrafficTxDrops Counter64, sm24tat4xbPortTrafficTxLateOrExcColl Counter64 } sm24tat4xbPortTrafficStatisticsPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 1 } sm24tat4xbPortTrafficStatisticsClear OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 2 } sm24tat4xbPortTrafficRxPackets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 3 } sm24tat4xbPortTrafficRxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 4 } sm24tat4xbPortTrafficRxUnicast OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 5 } sm24tat4xbPortTrafficRxMulticast OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 6 } sm24tat4xbPortTrafficRxBroadcast OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 7 } sm24tat4xbPortTrafficRxPause OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 8 } sm24tat4xbPortTrafficRx64Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 9 } sm24tat4xbPortTrafficRx65to127Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 10 } sm24tat4xbPortTrafficRx128to255Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 11 } sm24tat4xbPortTrafficRx256to511Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 12 } sm24tat4xbPortTrafficRx512to1023Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 13 } sm24tat4xbPortTrafficRx1024to1526Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 14 } sm24tat4xbPortTrafficRxExceecd1527Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 15 } sm24tat4xbPortTrafficRxQ0 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 16 } sm24tat4xbPortTrafficRxQ1 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 17 } sm24tat4xbPortTrafficRxQ2 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 18 } sm24tat4xbPortTrafficRxQ3 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 19 } sm24tat4xbPortTrafficRxQ4 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 20 } sm24tat4xbPortTrafficRxQ5 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 21 } sm24tat4xbPortTrafficRxQ6 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 22 } sm24tat4xbPortTrafficRxQ7 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 23 } sm24tat4xbPortTrafficRxDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 24 } sm24tat4xbPortTrafficRxCRCorAlignment OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 25 } sm24tat4xbPortTrafficRxUndersize OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 26 } sm24tat4xbPortTrafficRxOversize OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 27 } sm24tat4xbPortTrafficRxFragments OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 28 } sm24tat4xbPortTrafficRxJabber OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 29 } sm24tat4xbPortTrafficRxFiltered OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 30 } sm24tat4xbPortTrafficTxPackets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 31 } sm24tat4xbPortTrafficTxOctets OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 32 } sm24tat4xbPortTrafficTxUnicast OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 33 } sm24tat4xbPortTrafficTxMulticast OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 34 } sm24tat4xbPortTrafficTxBroadcast OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 35 } sm24tat4xbPortTrafficTxPause OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 36 } sm24tat4xbPortTrafficTx64Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 37 } sm24tat4xbPortTrafficTx65to127Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 38 } sm24tat4xbPortTrafficTx128to255Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 39 } sm24tat4xbPortTrafficTx256to511Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 40 } sm24tat4xbPortTrafficTx512to1023Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 41 } sm24tat4xbPortTrafficTx1024to1526Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 42 } sm24tat4xbPortTrafficTxExceecd1527Bytes OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 43 } sm24tat4xbPortTrafficTxQ0 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 44 } sm24tat4xbPortTrafficTxQ1 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 45 } sm24tat4xbPortTrafficTxQ2 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 46 } sm24tat4xbPortTrafficTxQ3 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 47 } sm24tat4xbPortTrafficTxQ4 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 48 } sm24tat4xbPortTrafficTxQ5 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 49 } sm24tat4xbPortTrafficTxQ6 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 50 } sm24tat4xbPortTrafficTxQ7 OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 51 } sm24tat4xbPortTrafficTxDrops OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 52 } sm24tat4xbPortTrafficTxLateOrExcColl OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortTrafficStatisticsEntry 53 } sm24tat4xbPortQoSStatistics OBJECT IDENTIFIER ::= { sm24tat4xbPort 3 } sm24tat4xbPortQoSStatisticsClear OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-only STATUS current DESCRIPTION "default: 0 0: none 1: clear " ::= { sm24tat4xbPortQoSStatistics 1 } sm24tat4xbPortQoSStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPortQoSStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatistics 2 } sm24tat4xbPortQoSStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBPortQoSStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPortQoSStatisticsPort } ::= { sm24tat4xbPortQoSStatisticsTable 1 } SM24TAT4XBPortQoSStatisticsEntry ::= SEQUENCE { sm24tat4xbPortQoSStatisticsPort Integer32, sm24tat4xbPortQoSQ0Rx Counter64, sm24tat4xbPortQoSQ0Tx Counter64, sm24tat4xbPortQoSQ1Rx Counter64, sm24tat4xbPortQoSQ1Tx Counter64, sm24tat4xbPortQoSQ2Rx Counter64, sm24tat4xbPortQoSQ2Tx Counter64, sm24tat4xbPortQoSQ3Rx Counter64, sm24tat4xbPortQoSQ3Tx Counter64, sm24tat4xbPortQoSQ4Rx Counter64, sm24tat4xbPortQoSQ4Tx Counter64, sm24tat4xbPortQoSQ5Rx Counter64, sm24tat4xbPortQoSQ5Tx Counter64, sm24tat4xbPortQoSQ6Rx Counter64, sm24tat4xbPortQoSQ6Tx Counter64, sm24tat4xbPortQoSQ7Rx Counter64, sm24tat4xbPortQoSQ7Tx Counter64 } sm24tat4xbPortQoSStatisticsPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 1 } sm24tat4xbPortQoSQ0Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 2 } sm24tat4xbPortQoSQ0Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 3 } sm24tat4xbPortQoSQ1Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 4 } sm24tat4xbPortQoSQ1Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 5 } sm24tat4xbPortQoSQ2Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 6 } sm24tat4xbPortQoSQ2Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 7 } sm24tat4xbPortQoSQ3Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 8 } sm24tat4xbPortQoSQ3Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 9 } sm24tat4xbPortQoSQ4Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 10 } sm24tat4xbPortQoSQ4Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 11 } sm24tat4xbPortQoSQ5Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 12 } sm24tat4xbPortQoSQ5Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 13 } sm24tat4xbPortQoSQ6Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 14 } sm24tat4xbPortQoSQ6Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 15 } sm24tat4xbPortQoSQ7Rx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 16 } sm24tat4xbPortQoSQ7Tx OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortQoSStatisticsEntry 17 } sm24tat4xbSFPInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSFPInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPort 4 } sm24tat4xbSFPInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBSFPInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbSFPInfoIndex } ::= { sm24tat4xbSFPInfoTable 1 } SM24TAT4XBSFPInfoEntry ::= SEQUENCE { sm24tat4xbSFPInfoIndex Integer32, sm24tat4xbSFPInfoPort DisplayString, sm24tat4xbSFPConnectorType DisplayString, sm24tat4xbSFPFiberType DisplayString, sm24tat4xbSFPTxCentralWavelength DisplayString, sm24tat4xbSFPBaudRate DisplayString, sm24tat4xbSFPVendorOUI DisplayString, sm24tat4xbSFPVendorName DisplayString, sm24tat4xbSFPVendorPN DisplayString, sm24tat4xbSFPVendorRev DisplayString, sm24tat4xbSFPVendorSN DisplayString, sm24tat4xbSFPDateCode DisplayString, sm24tat4xbSFPTemperature DisplayString, sm24tat4xbSFPVcc DisplayString, sm24tat4xbSFPMon1Bias DisplayString, sm24tat4xbSFPMon2TxPWR DisplayString, sm24tat4xbSFPMon3RxPWR DisplayString } sm24tat4xbSFPInfoIndex OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 1 } sm24tat4xbSFPInfoPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 2 } sm24tat4xbSFPConnectorType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 3 } sm24tat4xbSFPFiberType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 4 } sm24tat4xbSFPTxCentralWavelength OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 5 } sm24tat4xbSFPBaudRate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 6 } sm24tat4xbSFPVendorOUI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 7 } sm24tat4xbSFPVendorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 8 } sm24tat4xbSFPVendorPN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 9 } sm24tat4xbSFPVendorRev OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 10 } sm24tat4xbSFPVendorSN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 11 } sm24tat4xbSFPDateCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 12 } sm24tat4xbSFPTemperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 13 } sm24tat4xbSFPVcc OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 14 } sm24tat4xbSFPMon1Bias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 15 } sm24tat4xbSFPMon2TxPWR OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 16 } sm24tat4xbSFPMon3RxPWR OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbSFPInfoEntry 17 } sm24tat4xbVoiceVLAN OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 2 } sm24tat4xbVoiceVLANConf OBJECT IDENTIFIER ::= { sm24tat4xbVoiceVLAN 1 } sm24tat4xbVoiceVLANMode OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION " Voice VLAN mode operation. default: 0, 0: disable 1: enable" ::= { sm24tat4xbVoiceVLANConf 1 } sm24tat4xbVoiceVLANVLANId OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Voice VLAN ID. default: 1000, range : 1-4094. " ::= { sm24tat4xbVoiceVLANConf 2 } sm24tat4xbVoiceVLANAgingTime OBJECT-TYPE SYNTAX Integer32 (10..10000000) MAX-ACCESS read-write STATUS current DESCRIPTION " Voice VLAN secure learning aging time. default: 86400, range : 10 - 10000000. " ::= { sm24tat4xbVoiceVLANConf 3 } sm24tat4xbVoiceVLANTrafficClass OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION " Voice VLAN traffic class, all traffic on the Voice VLAN will apply this class, available value is from 0(Low) to 7(High). default: 7. " ::= { sm24tat4xbVoiceVLANConf 4 } sm24tat4xbVoiceVLANPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVoiceVLANPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Show Voice Vlan configuration. " ::= { sm24tat4xbVoiceVLANConf 5 } sm24tat4xbVoiceVLANPortEntry OBJECT-TYPE SYNTAX SM24TAT4XBVoiceVLANPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbVoiceVLANPort } ::= { sm24tat4xbVoiceVLANPortTable 1 } SM24TAT4XBVoiceVLANPortEntry ::= SEQUENCE { sm24tat4xbVoiceVLANPort Integer32, sm24tat4xbVoiceVLANPortMode Integer32, sm24tat4xbVoiceVLANPortSecurity Integer32, sm24tat4xbVoiceVLANPortDiscoveryProtocol Integer32 } sm24tat4xbVoiceVLANPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbVoiceVLANPortEntry 1 } sm24tat4xbVoiceVLANPortMode OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION " Voice VLAN port mode. default: 0, 0: Disable (Disjoin from Voice VLAN.) 1: Auto (Enable auto detect mode. It detects whether there is VoIP phone attached to the specific port and configures the Voice VLAN members automatically.) 2: Forced (Force join to Voice VLAN.)" ::= { sm24tat4xbVoiceVLANPortEntry 2 } sm24tat4xbVoiceVLANPortSecurity OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION " Voice VLAN port security mode. default: 0, 0: Disable (Disjoin from Voice VLAN.) 1: enable ( Enable Voice VLAN security mode. When the function is enabled, all non-telephone MAC address in Voice VLAN will be blocked 10 seconds.)" ::= { sm24tat4xbVoiceVLANPortEntry 3 } sm24tat4xbVoiceVLANPortDiscoveryProtocol OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION " Voice VLAN port discovery protocol. default: 0 0: OUI (Detect telephony device by OUI address.) 1: LLDP (Detect telephony device by LLDP.) 2: Both (Both OUI and LLDP.) " ::= { sm24tat4xbVoiceVLANPortEntry 4 } sm24tat4xbVoiceVLANOUI OBJECT IDENTIFIER ::= { sm24tat4xbVoiceVLAN 2 } sm24tat4xbVoiceVLANOUICreate OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0 : None (read only) 1 : Create an OUI entry" ::= { sm24tat4xbVoiceVLANOUI 1 } sm24tat4xbVoiceVLANOUITable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVoiceVLANOUIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Create Voice VLAN OUI entry. Modify OUI table will restart auto detect OUI process. " ::= { sm24tat4xbVoiceVLANOUI 2 } sm24tat4xbVoiceVLANOUIEntry OBJECT-TYPE SYNTAX SM24TAT4XBVoiceVLANOUIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbVoiceVLANOUIIndex } ::= { sm24tat4xbVoiceVLANOUITable 1 } SM24TAT4XBVoiceVLANOUIEntry ::= SEQUENCE { sm24tat4xbVoiceVLANOUIIndex Integer32, sm24tat4xbVoiceVLANTelephonyOUI DisplayString, sm24tat4xbVoiceVLANDescription DisplayString, sm24tat4xbVoiceVLANOUIRowStatus RowStatus } sm24tat4xbVoiceVLANOUIIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbVoiceVLANOUIEntry 1 } sm24tat4xbVoiceVLANTelephonyOUI OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "OUI address, format : 0a 1b 2c " ::= { sm24tat4xbVoiceVLANOUIEntry 2 } sm24tat4xbVoiceVLANDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION " Up to 32 characters describing OUI address. " ::= { sm24tat4xbVoiceVLANOUIEntry 3 } sm24tat4xbVoiceVLANOUIRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbVoiceVLANOUIEntry 4 } --sm24tat4xbGARP OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 3 } --sm24tat4xbGARPConfTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBGARPConfEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbGARP 1 } --sm24tat4xbGARPConfEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBGARPConfEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- INDEX { sm24tat4xbGARPConfPort } -- ::= { sm24tat4xbGARPConfTable 1 } --SM24TAT4XBGARPConfEntry ::= SEQUENCE { -- sm24tat4xbGARPConfPort Integer32, -- sm24tat4xbGARPJoinTimer Integer32, -- sm24tat4xbGARPLeaveTimer Integer32, -- sm24tat4xbGARPLeaveAllTimer Integer32, -- sm24tat4xbGARPApplicantion Integer32, -- sm24tat4xbGARPAttributeType Integer32, -- sm24tat4xbGARPApplicant Integer32 --} --sm24tat4xbGARPConfPort OBJECT-TYPE -- SYNTAX Integer32 (1..4095) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbGARPConfEntry 1 } --sm24tat4xbGARPJoinTimer OBJECT-TYPE -- SYNTAX Integer32 (200..1000) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 200, range : 200 - 1000 " -- ::= { sm24tat4xbGARPConfEntry 2 } --sm24tat4xbGARPLeaveTimer OBJECT-TYPE -- SYNTAX Integer32 (600..3000) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 600 , range : 600 - 3000" -- ::= { sm24tat4xbGARPConfEntry 3 } --sm24tat4xbGARPLeaveAllTimer OBJECT-TYPE -- SYNTAX Integer32 (10000..50000) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 10000, range : 10000 - 50000 " -- ::= { sm24tat4xbGARPConfEntry 4 } --sm24tat4xbGARPApplicantion OBJECT-TYPE -- SYNTAX Integer32(1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 1 -- 1: GVRP" -- ::= { sm24tat4xbGARPConfEntry 5 } --sm24tat4xbGARPAttributeType OBJECT-TYPE -- SYNTAX Integer32(1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 1 -- 1: VLAN" -- ::= { sm24tat4xbGARPConfEntry 6 } --sm24tat4xbGARPApplicant OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0 -- 0: normal-participant -- 1: non-participant" -- ::= { sm24tat4xbGARPConfEntry 7 } --sm24tat4xbGARPStatisticsTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBGARPStatisticsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " Show the basic GARP port statistics. " -- ::= { sm24tat4xbGARP 2 } --sm24tat4xbGARPStatisticsEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBGARPStatisticsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- INDEX { sm24tat4xbGARPStatisticsPort } -- ::= { sm24tat4xbGARPStatisticsTable 1 } --SM24TAT4XBGARPStatisticsEntry ::= SEQUENCE { -- sm24tat4xbGARPStatisticsPort Integer32, -- sm24tat4xbGARPStatisticsPeerMAC DisplayString, -- sm24tat4xbGARPStatisticsFailedCount Counter32 --} --sm24tat4xbGARPStatisticsPort OBJECT-TYPE -- SYNTAX Integer32 (1..4095) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " port, range : 1 - port number. " -- ::= { sm24tat4xbGARPStatisticsEntry 1 } --sm24tat4xbGARPStatisticsPeerMAC OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " Peer MAC is MAC address of the neighbour Switch from with GARP frame is received. " -- ::= { sm24tat4xbGARPStatisticsEntry 2 } --sm24tat4xbGARPStatisticsFailedCount OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " explain Failed count here. " -- ::= { sm24tat4xbGARPStatisticsEntry 3 } sm24tat4xbGVRP OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 4 } sm24tat4xbGVRPConf OBJECT IDENTIFIER ::= { sm24tat4xbGVRP 1 } sm24tat4xbGVRPMode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0, 0: disable, 1: enable. " ::= { sm24tat4xbGVRPConf 1 } sm24tat4xbGVRPMaxVlan OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of simultaniously VLANs that GVRP can control. " ::= { sm24tat4xbGVRPConf 2 } sm24tat4xbGVRPJoinTime OBJECT-TYPE SYNTAX Integer32(1..20) MAX-ACCESS read-write STATUS current DESCRIPTION "join-time in units of centi seconds. Range is 1-20. Default is 20. " ::= { sm24tat4xbGVRPConf 3 } sm24tat4xbGVRPLeaveTime OBJECT-TYPE SYNTAX Integer32(60..300) MAX-ACCESS read-write STATUS current DESCRIPTION "leave-time in units of centi seconds. Range is 60-300. Default is 60. " ::= { sm24tat4xbGVRPConf 4 } sm24tat4xbGVRPLeaveAllTime OBJECT-TYPE SYNTAX Integer32(1000..5000) MAX-ACCESS read-write STATUS current DESCRIPTION "leave-all-time in units of centi seconds Range is 1000-5000. Default is 1000" ::= { sm24tat4xbGVRPConf 5 } sm24tat4xbGVRPConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBGVRPConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbGVRPConf 6 } sm24tat4xbGVRPConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBGVRPConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbGVRPConfPort } ::= { sm24tat4xbGVRPConfTable 1 } SM24TAT4XBGVRPConfEntry ::= SEQUENCE { sm24tat4xbGVRPConfPort Integer32, sm24tat4xbGVRPConfPortMode Integer32 -- sm24tat4xbGVRPConfPortRRole Integer32 } sm24tat4xbGVRPConfPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbGVRPConfEntry 1 } sm24tat4xbGVRPConfPortMode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 1: enable 0: disable" ::= { sm24tat4xbGVRPConfEntry 2 } --sm24tat4xbGVRPConfPortRRole OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0 -- 1: enable -- 0: disable" -- ::= { sm24tat4xbGVRPConfEntry 3 } --sm24tat4xbGVRPStatisticsTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBGVRPStatisticsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbGVRP 2 } --sm24tat4xbGVRPStatisticsEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBGVRPStatisticsEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- INDEX { sm24tat4xbGVRPStatisticsPort } -- ::= { sm24tat4xbGVRPStatisticsTable 1 } --SM24TAT4XBGVRPStatisticsEntry ::= SEQUENCE { -- sm24tat4xbGVRPStatisticsPort Integer32, -- sm24tat4xbGVRPStatisticsJoinTxCnt Counter32, -- sm24tat4xbGVRPStatisticsLeaveTxCnt Counter32 --} --sm24tat4xbGVRPStatisticsPort OBJECT-TYPE -- SYNTAX Integer32 (1..4095) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbGVRPStatisticsEntry 1 } --sm24tat4xbGVRPStatisticsJoinTxCnt OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbGVRPStatisticsEntry 2 } --sm24tat4xbGVRPStatisticsLeaveTxCnt OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " " -- ::= { sm24tat4xbGVRPStatisticsEntry 3 } sm24tat4xbMirroring OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 6 } sm24tat4xbMonitorSession OBJECT-TYPE SYNTAX Integer32(1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "Monitor session." ::= { sm24tat4xbMirroring 1 } sm24tat4xbPortToMirrorOn OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable, range : 1 - port number. " ::= { sm24tat4xbMirroring 2 } sm24tat4xbMirrorTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMirrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMirroring 3 } sm24tat4xbMirrorEntry OBJECT-TYPE SYNTAX SM24TAT4XBMirrorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMirrorPort } ::= { sm24tat4xbMirrorTable 1 } SM24TAT4XBMirrorEntry ::= SEQUENCE { sm24tat4xbMirrorPort Integer32, sm24tat4xbMirrorMode Integer32 } sm24tat4xbMirrorPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMirrorEntry 1 } sm24tat4xbMirrorMode OBJECT-TYPE SYNTAX Integer32(0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: rx only 2: tx only 3: enable Setting Tx mirroring for analyzer port has no effect. Tx mirroring ignored" ::= { sm24tat4xbMirrorEntry 2 } sm24tat4xbTrapEventSeverity OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 7 } sm24tat4xbTrapEventSeverityTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBTrapEventSeverityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbTrapEventSeverity 1 } sm24tat4xbTrapEventSeverityEntry OBJECT-TYPE SYNTAX SM24TAT4XBTrapEventSeverityEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbTrapEventSeverityIndex } ::= { sm24tat4xbTrapEventSeverityTable 1 } SM24TAT4XBTrapEventSeverityEntry ::= SEQUENCE { sm24tat4xbTrapEventSeverityIndex Integer32, sm24tat4xbTrapEventSeverityGroupName DisplayString, sm24tat4xbTrapEventSeverityLevel Integer32, sm24tat4xbTrapEventSeveritySyslog Integer32, sm24tat4xbTrapEventSeverityTrap Integer32, sm24tat4xbTrapEventSeveritySMTP Integer32 } sm24tat4xbTrapEventSeverityIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbTrapEventSeverityEntry 1 } sm24tat4xbTrapEventSeverityGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Group Name" ::= { sm24tat4xbTrapEventSeverityEntry 2 } sm24tat4xbTrapEventSeverityLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "0:Emergency 1:Alert 2:Critical 3:Error 4:Warning 5:Notice 6:Information 7:Debug" ::= { sm24tat4xbTrapEventSeverityEntry 3 } sm24tat4xbTrapEventSeveritySyslog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbTrapEventSeverityEntry 4 } sm24tat4xbTrapEventSeverityTrap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbTrapEventSeverityEntry 5 } sm24tat4xbTrapEventSeveritySMTP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbTrapEventSeverityEntry 6 } -- ======================================================================================================================= sm24tat4xbSMTP OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 8 } sm24tat4xbSMTPMailServer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing email server. " ::= { sm24tat4xbSMTP 1 } sm24tat4xbSMTPUserName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing user name. " ::= { sm24tat4xbSMTP 2 } sm24tat4xbSMTPPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing password. " ::= { sm24tat4xbSMTP 3 } sm24tat4xbSMTPSender OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing sender. " ::= { sm24tat4xbSMTP 5 } sm24tat4xbSMTPReturnPath OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing return path. " ::= { sm24tat4xbSMTP 6 } sm24tat4xbSMTPEmailAddress1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing mail address. " ::= { sm24tat4xbSMTP 7 } sm24tat4xbSMTPEmailAddress2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing mail address. " ::= { sm24tat4xbSMTP 8 } sm24tat4xbSMTPEmailAddress3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing mail address. " ::= { sm24tat4xbSMTP 9 } sm24tat4xbSMTPEmailAddress4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing mail address. " ::= { sm24tat4xbSMTP 10 } sm24tat4xbSMTPEmailAddress5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing mail address. " ::= { sm24tat4xbSMTP 11 } sm24tat4xbSMTPEmailAddress6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " Up to 47 characters describing mail address. " ::= { sm24tat4xbSMTP 12 } -- ======================================================================================================================= sm24tat4xbACLConf OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 9 } -- RowStatus Info: createAndGo, notReady not supported. -- ======================================================================================================================= -- Textual Conventions for the sm24tat4xb Acl Mib -- ======================================================================================================================= -- sm24tat4xbACL OBJECT IDENTIFIER ::= { sm24tat4xbACLConf 1 } sm24tat4xbACLACE OBJECT IDENTIFIER ::= { sm24tat4xbACLConf 3 } -- -- ======================================================================================================================= -- Start sm24tat4xbACLPortConf group -- ======================================================================================================================= --sm24tat4xbACLPortConfTable sm24tat4xbACLPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBACLPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL Port Conf Table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbACL 1 } sm24tat4xbACLPortConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBACLPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL Port Conf Entry. " INDEX { ifIndex } ::= { sm24tat4xbACLPortConfTable 1 } SM24TAT4XBACLPortConfEntry ::= SEQUENCE { sm24tat4xbACLPortConfPolicyID Integer32, sm24tat4xbACLPortConfAction INTEGER, sm24tat4xbACLPortConfRateLimiterID Integer32, sm24tat4xbACLPortConfPortRedirect Integer32, sm24tat4xbACLPortConfMirror AdminMode, sm24tat4xbACLPortConfLogging AdminMode, sm24tat4xbACLPortConfShutdown AdminMode, sm24tat4xbACLPortConfState AdminMode, sm24tat4xbACLPortConfCounter Counter32 } sm24tat4xbACLPortConfPolicyID OBJECT-TYPE SYNTAX Integer32 (0..127) MAX-ACCESS read-write STATUS current DESCRIPTION "The policy to apply to this port. default: 0, range : 0 - 127. " ::= { sm24tat4xbACLPortConfEntry 2 } sm24tat4xbACLPortConfAction OBJECT-TYPE SYNTAX INTEGER { deny(0), permit(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Whether forwarding is permitted ('Permit') or denied ('Deny'). default: 1, 0: Deny, 1: Permit." ::= { sm24tat4xbACLPortConfEntry 3 } sm24tat4xbACLPortConfRateLimiterID OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The rate limiter to apply on this port. 0: Disable, range : 0 - 16. " ::= { sm24tat4xbACLPortConfEntry 4 } sm24tat4xbACLPortConfPortRedirect OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Port frames are redirected on. 0: Disable, range : 0 - end port number. " ::= { sm24tat4xbACLPortConfEntry 5 } sm24tat4xbACLPortConfMirror OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "The mirror operation of this port." ::= { sm24tat4xbACLPortConfEntry 6 } sm24tat4xbACLPortConfLogging OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the logging operation of this port." ::= { sm24tat4xbACLPortConfEntry 7 } sm24tat4xbACLPortConfShutdown OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the port shut down operation of this port." DEFVAL { disable } ::= { sm24tat4xbACLPortConfEntry 8 } sm24tat4xbACLPortConfState OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the port state of this port." DEFVAL { enable } ::= { sm24tat4xbACLPortConfEntry 9 } sm24tat4xbACLPortConfCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts the number of frames that match this ACE. " ::= { sm24tat4xbACLPortConfEntry 10 } -- -- ======================================================================================================================= -- Start sm24tat4xbACLRateLimiter group -- ======================================================================================================================= --sm24tat4xbACLRateLimiterTable sm24tat4xbACLRateLimiterTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBACLRateLimiterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL Rate Limiter Table." ::= { sm24tat4xbACL 2 } sm24tat4xbACLRateLimiterEntry OBJECT-TYPE SYNTAX SM24TAT4XBACLRateLimiterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL Rate Limiter Entry. " INDEX { sm24tat4xbACLRateLimiterID } ::= { sm24tat4xbACLRateLimiterTable 1 } SM24TAT4XBACLRateLimiterEntry ::= SEQUENCE { sm24tat4xbACLRateLimiterID Integer32, sm24tat4xbACLRateLimiterRate Integer32, sm24tat4xbACLRateLimiterUnit Integer32 } sm24tat4xbACLRateLimiterID OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Rate Limiter ID. range : 1-16 " ::= { sm24tat4xbACLRateLimiterEntry 1 } sm24tat4xbACLRateLimiterRate OBJECT-TYPE SYNTAX Integer32(0..500000) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 1, range : <0-500000> 10pps,The valid rate is 0, 10, 20, 30, ..., 5000000 in pps. <0-400000> 25kbps,The valid rate is 0, 25, 50, 75,..., 10000000 in kbps." ::= { sm24tat4xbACLRateLimiterEntry 2 } sm24tat4xbACLRateLimiterUnit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the rate unit. 0: 10pps, 1: 25kbps. " ::= { sm24tat4xbACLRateLimiterEntry 3 } -- -- ======================================================================================================================= -- Start sm24tat4xbACLACE group -- ======================================================================================================================= --sm24tat4xbACLACEClear sm24tat4xbACLACEClear OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Clear all ACE counters." ::= { sm24tat4xbACLACE 1 } --sm24tat4xbACLACETable sm24tat4xbACLACETable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBACLACEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Create ACL ACE entry. " ::= { sm24tat4xbACLACE 2 } sm24tat4xbACLACEEntry OBJECT-TYPE SYNTAX SM24TAT4XBACLACEEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACLACE Table." INDEX { sm24tat4xbACLACEIndex } ::= { sm24tat4xbACLACETable 1 } SM24TAT4XBACLACEEntry ::= SEQUENCE { sm24tat4xbACLACEIndex Integer32, sm24tat4xbACLACEID Integer32, sm24tat4xbACLACENextID Integer32, -- sm24tat4xbACLACELoopUp AdminMode, sm24tat4xbACLACEIngressPort DisplayString, sm24tat4xbACLACEPortPolicyNumber Integer32, sm24tat4xbACLACEPortPolicyBitmask Integer32, sm24tat4xbACLACEFrameType INTEGER, sm24tat4xbACLACEAction INTEGER, sm24tat4xbACLACEFilterPort DisplayString, sm24tat4xbACLACEDenyPortRedirect DisplayString, sm24tat4xbACLACERateLimiter Integer32, sm24tat4xbACLACEMirror AdminMode, sm24tat4xbACLACELogging AdminMode, sm24tat4xbACLACEShutdown AdminMode, sm24tat4xbACLACECounter Counter32, sm24tat4xbACLACEVLAN8021QTagged INTEGER, sm24tat4xbACLACEVLANVID Integer32, sm24tat4xbACLACEVLANTagPriority Integer32, sm24tat4xbACLACESMAC DisplayString, sm24tat4xbACLACEDMACType INTEGER, sm24tat4xbACLACEDMAC DisplayString, sm24tat4xbACLACEEtherType Integer32, sm24tat4xbACLACEArpOpCode INTEGER, sm24tat4xbACLACEArpFlagsRequestReply INTEGER, sm24tat4xbACLACEArpFlagsArpSMac INTEGER, sm24tat4xbACLACEArpFlagsRarpDmac INTEGER, sm24tat4xbACLACEArpFlagsLength INTEGER, sm24tat4xbACLACEArpFlagsIp INTEGER, sm24tat4xbACLACEArpFlagsEthernet INTEGER, sm24tat4xbACLACESIPType INTEGER, sm24tat4xbACLACESIPIPAddress IpAddress, sm24tat4xbACLACESIPIPMask IpAddress, sm24tat4xbACLACEDIPType INTEGER, sm24tat4xbACLACEDIPIPAddress IpAddress, sm24tat4xbACLACEDIPIPMask IpAddress, sm24tat4xbACLACEIPProtocol INTEGER, sm24tat4xbACLACEIPProtocolValue Integer32, sm24tat4xbACLACEIPFlagsTTL INTEGER, sm24tat4xbACLACEIPFlagsFragment INTEGER, sm24tat4xbACLACEIPFlagsOptions INTEGER, sm24tat4xbACLACEICMPType Integer32, sm24tat4xbACLACEICMPCode Integer32, sm24tat4xbACLACESourcePort DisplayString, sm24tat4xbACLACEDestPort DisplayString, sm24tat4xbACLACETCPFlagsFin INTEGER, sm24tat4xbACLACETCPFlagsSyn INTEGER, sm24tat4xbACLACETCPFlagsRst INTEGER, sm24tat4xbACLACETCPFlagsPsh INTEGER, sm24tat4xbACLACETCPFlagsAck INTEGER, sm24tat4xbACLACETCPFlagsUrg INTEGER, sm24tat4xbACLACEIPv6SIPAddress DisplayString, sm24tat4xbACLACEIPv6SIPBitmask DisplayString, sm24tat4xbACLACEIPv6HopLimit INTEGER, sm24tat4xbACLACESMACMask DisplayString, sm24tat4xbACLACEDMACMask DisplayString, sm24tat4xbACLACERowStatus RowStatus } sm24tat4xbACLACEIndex OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index. " ::= { sm24tat4xbACLACEEntry 1 } sm24tat4xbACLACEID OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS read-create STATUS current DESCRIPTION "If the ACE ID is specified and an entry with this ACE ID already exists, the ACE will be modified. Otherwise, a new ACE will be added. range : 1 - 256. " ::= { sm24tat4xbACLACEEntry 2 } sm24tat4xbACLACENextID OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-create STATUS current DESCRIPTION "If the next ACE ID is non zero, the ACE will be placed before this ACE in the list. If the next ACE ID is zero, the ACE will be placed last in the list. range : 0 - 256. " ::= { sm24tat4xbACLACEEntry 3 } -- sm24tat4xbACLACELoopUp OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "Specify the second lookup operation of the ACE." -- ::= { sm24tat4xbACLACEEntry 4 } -- sm24tat4xbACLACEIngressPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the ingress port of the ACE. Possible values are: 0: All,The ACE will match all ingress port. Port n: The ACE will match a specific ingress port." ::= { sm24tat4xbACLACEEntry 5 } sm24tat4xbACLACEPortPolicyNumber OBJECT-TYPE SYNTAX Integer32(0..127) MAX-ACCESS read-create STATUS current DESCRIPTION "policy value. range : 0 - 127. 0: Any." ::= { sm24tat4xbACLACEEntry 6 } sm24tat4xbACLACEPortPolicyBitmask OBJECT-TYPE SYNTAX Integer32(0..127) MAX-ACCESS read-create STATUS current DESCRIPTION "When 'Specific' is selected for the policy filter, you can enter a specific policy bitmask. range : 0 - 127, 0: no data." ::= { sm24tat4xbACLACEEntry 7 } sm24tat4xbACLACEFrameType OBJECT-TYPE SYNTAX INTEGER { any(0), etype(1), arp(2), ipv4(3), ipv6(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "Select the frame type for this ACE. When change the type Related oid will set default. 0: any, 1: etype, 2: arp, 3: ipv4, 4: ipv6." ::= { sm24tat4xbACLACEEntry 8 } sm24tat4xbACLACEAction OBJECT-TYPE SYNTAX INTEGER { deny(0), permit(1), filter(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "0: Deny 1: Permit 2: Filter" ::= { sm24tat4xbACLACEEntry 9 } sm24tat4xbACLACEFilterPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "When 'Action' is 'Filter' can set. 0: Disable, Port n: The ACE applies to this port number, where n is the number of the switch port. range: 0 - Port number. " ::= { sm24tat4xbACLACEEntry 10 } sm24tat4xbACLACEDenyPortRedirect OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Frames that hit the ACE are redirected to the port number specified here.Disabled,indicates that the port redirect operation is disabled. When 'Action' is 'Deny' can set. 0: disabled, Port no: The ACE applies to this port number, where n is the number of the switch port." ::= { sm24tat4xbACLACEEntry 11 } sm24tat4xbACLACERateLimiter OBJECT-TYPE SYNTAX Integer32(0..16) MAX-ACCESS read-create STATUS current DESCRIPTION "default: 0, 0: Disable range : 0 - 16 " ::= { sm24tat4xbACLACEEntry 12 } sm24tat4xbACLACEMirror OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-create STATUS current DESCRIPTION "default: 0, 0: disable - Frames matching the ACE are not mirrored. 1: enable - Frames matching the ACE are mirrored. " ::= { sm24tat4xbACLACEEntry 13 } sm24tat4xbACLACELogging OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-create STATUS current DESCRIPTION "default: 0, 0: disable - Frames matching the ACE are not logged. 1: enable - Frames matching the ACE are stored in the system log." ::= { sm24tat4xbACLACEEntry 14 } sm24tat4xbACLACEShutdown OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-create STATUS current DESCRIPTION "default: 0, 0: disable - Port shut down is disabled for the AC. 1: enable - If a frame matches the ACE, the ingress port will be disabled." ::= { sm24tat4xbACLACEEntry 15 } sm24tat4xbACLACECounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter indicates the number of times the ACE was hit by a frame. " ::= { sm24tat4xbACLACEEntry 16 } sm24tat4xbACLACEVLAN8021QTagged OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1), any(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specify whether frames can hit the action according to the 802.1Q tagged. default: 2, 0: disable - Untagged frame only. 1: enable - Tagged frame only. 2: Any - Any value is allowed. " ::= { sm24tat4xbACLACEEntry 17 } sm24tat4xbACLACEVLANVID OBJECT-TYPE SYNTAX Integer32(0..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the VLAN ID filter for this ACE. The vid can't be set when 802.1Q Tagged is disabled. default: 0, 0: Any - No VLAN ID filter is specified. range : 0 - 4095 " ::= { sm24tat4xbACLACEEntry 18 } sm24tat4xbACLACEVLANTagPriority OBJECT-TYPE SYNTAX Integer32(0..14) MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the tag priority for this ACE. The tag priority can't be set when 802.1Q Tagged is disabled. range: 0-14 0:0 1:1 2:2 3:3 4:4 5:5 6:6 7:7 8:0-1 9:2-3 10:4-5 11:6-7 12:0-3 13:4-7 14:Any " ::= { sm24tat4xbACLACEEntry 19 } sm24tat4xbACLACESMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Configure source MAC address for this ACE. : A frame that hits this ACE matches this source MAC address value. xx-xx-xx-xx-xx-xx. Any: Don't care." ::= { sm24tat4xbACLACEEntry 20 } sm24tat4xbACLACEDMACType OBJECT-TYPE SYNTAX INTEGER { any(0), mc(1), bc(2), uc(3) , macAddress(4) , noData(5) } MAX-ACCESS read-create STATUS current DESCRIPTION "DMAC Type. default: 0, 0: Any - Don't care. 1: Multicast - Frame must be multicast. 2: Broadcast - Frame must be broadcast. 3: Unicast - Frame must be unicast. 4: mac address. 5: no data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 21 } sm24tat4xbACLACEDMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Configure destination MAC address for this ACE. : A frame that hits this ACE matches this destination MAC address value. xx-xx-xx-xx-xx-xx." ::= { sm24tat4xbACLACEEntry 22 } sm24tat4xbACLACEEtherType OBJECT-TYPE SYNTAX Integer32(-1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "0: Any range : 0, or 1536(0x0600) - 65535(0xffff) but excluding 0x0800(IPv4) 0x0806(ARP) and 0x86DD(IPv6). -1: No data. " ::= { sm24tat4xbACLACEEntry 23 } sm24tat4xbACLACEArpOpCode OBJECT-TYPE SYNTAX INTEGER { any(0), arp(1), rarp(2), other(3), noData(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure ARP opcode for this ACE. default: 0, 0: Any - Don't care. 1: arp. 2: rarp. 3: other. 4: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 24 } sm24tat4xbACLACEArpFlagsRequestReply OBJECT-TYPE SYNTAX INTEGER { reply(0), request(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the available ARP/RARP opcode (OP) flag for this ACE. default: 2, 0: Frame must have ARP Reply or RARP Reply OP flag. 1: Frame must have ARP Request or RARP Request OP flag set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 25 } sm24tat4xbACLACEArpFlagsArpSMac OBJECT-TYPE SYNTAX INTEGER { notEqualSMAC(0), equalSMAC(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify whether frames can hit the action according to their sender hardware address field (SHA) settings. default: 2, 0: ARP frames where SHA is not equal to the SMAC address. 1: ARP frames where SHA is equal to the SMAC address. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 26 } sm24tat4xbACLACEArpFlagsRarpDmac OBJECT-TYPE SYNTAX INTEGER { notEqualDMAC(0), equalDMAC(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify whether frames can hit the action according to their target hardware address field (THA) settings. default: 2, 0: RARP frames where THA is not equal to the DMAC address. 1: RARP frames where THA is equal to the DMAC address. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 27 } sm24tat4xbACLACEArpFlagsLength OBJECT-TYPE SYNTAX INTEGER { notEqualEthIpV4 (0), equalEthIpV4(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify whether frames can hit the action according to their ARP/RARP hardware address length (HLN) and protocol address length (PLN) settings. default: 2, 0: ARP/RARP frames where the HLN is not equal to Ethernet(0x06) or the (PLN) is not equal to IPv4(0x04). 1: ARP/RARP frames where the HLN is equal to Ethernet (0x06) and the (PLN) is equal to IPv4(0x04). 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 28 } sm24tat4xbACLACEArpFlagsIp OBJECT-TYPE SYNTAX INTEGER { notEqualEth(0), equalEth(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify whether frames can hit the action according to their ARP/RARP hardware address space (HRD) settings. default: 2, 0: ARP/RARP frames where the HLD is not equal to Ethernet(1). 1: ARP/RARP frames where the HLD is equal to Ethernet(1). 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 29 } sm24tat4xbACLACEArpFlagsEthernet OBJECT-TYPE SYNTAX INTEGER { notEqualIp(0), equalIp(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify whether frames can hit the action according to their ARP/RARP protocol address space (PRO) settings. default: 2, 0: ARP/RARP frames where the PRO is not equal to IP\n(0x800). 1: ARP/RARP frames where the PRO is equal to IP(0x800). 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 30 } sm24tat4xbACLACESIPType OBJECT-TYPE SYNTAX INTEGER { any(0), ip(1), network(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure source IP address for this ACE. default: 0, 0: Any - Don't care. 1: IP Address. 2: Network. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 31 } sm24tat4xbACLACESIPIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "A frame that hits this ACE matches this source IP address value." ::= { sm24tat4xbACLACEEntry 32 } sm24tat4xbACLACESIPIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Specific sender IP mask in dotted decimal notation." ::= { sm24tat4xbACLACEEntry 33 } sm24tat4xbACLACEDIPType OBJECT-TYPE SYNTAX INTEGER { any(0), ip(1), network(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure destination IP address for this ACE. default: 0, 0: Any - Don't care. 1: IP Address. 2: Network. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 34 } sm24tat4xbACLACEDIPIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "A frame that hits this ACE matches this destination IP address value." ::= { sm24tat4xbACLACEEntry 35 } sm24tat4xbACLACEDIPIPMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Specific sender IP mask in dotted decimal notation." ::= { sm24tat4xbACLACEEntry 36 } sm24tat4xbACLACEIPProtocol OBJECT-TYPE SYNTAX INTEGER{ any(0), icmp(1), udp(2), tcp(3), other(4), noData(5)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the IP protocol filter for this ACE. default: 0, 0: Any, 1: ICMP, 2: UDP, 3: TCP, 4: Other, 5: no data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 37 } sm24tat4xbACLACEIPProtocolValue OBJECT-TYPE SYNTAX Integer32(0..256) MAX-ACCESS read-create STATUS current DESCRIPTION "Configure IP protocol value for this ACE when IP Protocol is 'other'. default: 256, 256: No data. range : 0 - 256" ::= { sm24tat4xbACLACEEntry 38 } sm24tat4xbACLACEIPFlagsTTL OBJECT-TYPE SYNTAX INTEGER { nonZero(0), zero(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the Time-to-Live settings for this ACE. default: 0, 0: zero, 1: Non-Zero 2: Any,, 3: No data." DEFVAL { nonZero } ::= { sm24tat4xbACLACEEntry 39 } sm24tat4xbACLACEIPFlagsFragment OBJECT-TYPE SYNTAX INTEGER{yes(0), no(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the fragment offset settings for this ACE. default: 2, 0: No, 1: Yes, 2: Any, 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 40 } sm24tat4xbACLACEIPFlagsOptions OBJECT-TYPE SYNTAX INTEGER{yes(0), no(1), any(2), noData(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the options flag setting for this ACE. default: 2, 0: No, 1: Yes, 2: Any, 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 41 } sm24tat4xbACLACEICMPType OBJECT-TYPE SYNTAX Integer32(0..257) MAX-ACCESS read-create STATUS current DESCRIPTION "Configure ICMP type for this ACE. default: 256, 256: Any - Don't care. 257: No data. range : 0 - 257." ::= { sm24tat4xbACLACEEntry 42 } sm24tat4xbACLACEICMPCode OBJECT-TYPE SYNTAX Integer32(0..257) MAX-ACCESS read-create STATUS current DESCRIPTION "Configure ICMP code for this ACE. default: 256, 256: Any - Don't care. 257: No data. range : 0 - 257." ::= { sm24tat4xbACLACEEntry 43 } sm24tat4xbACLACESourcePort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Configure Source UDP/TCP port range for this ACE. default: any, specific: 0~65535, range : 0 - 65535." ::= { sm24tat4xbACLACEEntry 44 } sm24tat4xbACLACEDestPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Configure Destination UDP/TCP port range for this ACE. default: any, specific: 0~65535, range : 0 - 65535." ::= { sm24tat4xbACLACEEntry 45 } sm24tat4xbACLACETCPFlagsFin OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure TCP (FIN) flags for this ACE. default: 2, 0: TCP frames where the FIN field is unset. 1: TCP frames where the FIN field is set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 46 } sm24tat4xbACLACETCPFlagsSyn OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure TCP (SYN) flags for this ACE. default: 2, 0: TCP frames where the SYN field is unset. 1: TCP frames where the SYN field is set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 47 } sm24tat4xbACLACETCPFlagsRst OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure TCP (RST) flags for this ACE. default: 2, 0: TCP frames where the RST field is unset. 1: TCP frames where the RST field is set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 48 } sm24tat4xbACLACETCPFlagsPsh OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure TCP (PSH) flags for this ACE. default: 2, 0: TCP frames where the PSH field is unset. 1: TCP frames where the PSH field is set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 49 } sm24tat4xbACLACETCPFlagsAck OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure TCP (ACK) flags for this ACE. default: 2, 0: TCP frames where the ACK field is unset. 1: TCP frames where the ACK field is set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 50 } sm24tat4xbACLACETCPFlagsUrg OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Configure TCP (URG) flags for this ACE. default: 2, 0: TCP frames where the URG field is unset. 1: TCP frames where the URG field is set. 2: Any - Don't care. 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 51 } sm24tat4xbACLACEIPv6SIPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "When 'Specific' is selected for the source IPv6 filter, you can enter a specific SIPv6 address. The field only supported last 32 bits for IPv6 address. " ::= { sm24tat4xbACLACEEntry 52 } sm24tat4xbACLACEIPv6SIPBitmask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "When 'Specific' is selected for the source IPv6 filter, you can enter a specific SIPv6 mask. The field only supported last 32 bits for IPv6 address. " ::= { sm24tat4xbACLACEEntry 53 } sm24tat4xbACLACEIPv6HopLimit OBJECT-TYPE SYNTAX INTEGER { unset(0), set(1), any(2), noData(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the hop limit settings for this ACE. default: 2, 0: Where the Hop Limit field is unset. 1: Where the Hop Limit field is set. 2: Any - Don't care, 3: No data." DEFVAL { any } ::= { sm24tat4xbACLACEEntry 54 } sm24tat4xbACLACESMACMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Configure source MAC address mask for this ACE. : A frame that hits this ACE matches this source MAC address value. xx-xx-xx-xx-xx-xx." ::= { sm24tat4xbACLACEEntry 56 } sm24tat4xbACLACEDMACMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Configure destination MAC address mask for this ACE. : A frame that hits this ACE matches this destination MAC address value. xx-xx-xx-xx-xx-xx." ::= { sm24tat4xbACLACEEntry 57 } sm24tat4xbACLACERowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbACLACEEntry 58 } -- -- ======================================================================================================================= -- Start sm24tat4xbACLStatus group -- ======================================================================================================================= --sm24tat4xbACLStatusTable sm24tat4xbACLStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBACLStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " ACL ACE Status entry. " ::= { sm24tat4xbACL 4 } sm24tat4xbACLStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBACLStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL Status Entry." INDEX { sm24tat4xbACLStatusIndex } ::= { sm24tat4xbACLStatusTable 1 } SM24TAT4XBACLStatusEntry ::= SEQUENCE { sm24tat4xbACLStatusIndex Integer32, sm24tat4xbACLStatusUser DisplayString, sm24tat4xbACLStatusID Integer32, sm24tat4xbACLStatusIngressPort DisplayString, sm24tat4xbACLStatusFrameType DisplayString, sm24tat4xbACLStatusAction DisplayString, sm24tat4xbACLStatusRateLimiter DisplayString, sm24tat4xbACLStatusPortRedirect DisplayString, sm24tat4xbACLStatusMirror DisplayString, sm24tat4xbACLStatusCPU DisplayString, sm24tat4xbACLStatusCPUOnce DisplayString, sm24tat4xbACLStatusCounter Counter32, sm24tat4xbACLStatusConflict DisplayString } sm24tat4xbACLStatusIndex OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ACL status index. " ::= { sm24tat4xbACLStatusEntry 1 } sm24tat4xbACLStatusUser OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ACL user. S : Static, IPMG : IP Management, IPSG : IP Source Guard, IPMC : IPMC, ARPI : Arp Inspection, UPnP : UPnP, DHCP : DHCP. " ::= { sm24tat4xbACLStatusEntry 2 } sm24tat4xbACLStatusID OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "ACE ID. range : 1 - 256. " ::= { sm24tat4xbACLStatusEntry 3 } sm24tat4xbACLStatusIngressPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the ingress port of the ACE. Possible values are: All: The ACE will match all ingress port. Port: The ACE will match a specific ingress port. " ::= { sm24tat4xbACLStatusEntry 4 } sm24tat4xbACLStatusFrameType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the frame type of the ACE. Any: The ACE will match any frame type. EType: The ACE will match Ethernet Type frames. Note that an Ethernet Type based ACE will not get matched by IP and ARP frames. ARP: The ACE will match ARP/RARP frames. IPv4: The ACE will match all IPv4 frames. IPv4/ICMP: The ACE will match IPv4 frames with ICMP protocol. IPv4/UDP: The ACE will match IPv4 frames with UDP protocol. IPv4/TCP: The ACE will match IPv4 frames with TCP protocol. IPv4/Other: The ACE will match IPv4 frames, which are not ICMP/UDP/TCP. IPv6: The ACE will match all IPv6 standard frames. " ::= { sm24tat4xbACLStatusEntry 5 } sm24tat4xbACLStatusAction OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the forwarding action of the ACE. " ::= { sm24tat4xbACLStatusEntry 6 } sm24tat4xbACLStatusRateLimiter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the rate limiter number of the ACE. " ::= { sm24tat4xbACLStatusEntry 7 } sm24tat4xbACLStatusPortRedirect OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the port redirect operation of the ACE. Frames matching the ACE are redirected to the port number. " ::= { sm24tat4xbACLStatusEntry 8 } sm24tat4xbACLStatusMirror OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Specify the mirror operation of this port." ::= { sm24tat4xbACLStatusEntry 9 } sm24tat4xbACLStatusCPU OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Forward packet that matched the specific ACE to CPU. " ::= { sm24tat4xbACLStatusEntry 10 } sm24tat4xbACLStatusCPUOnce OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Forward first packet that matched the specific ACE to CPU. " ::= { sm24tat4xbACLStatusEntry 11 } sm24tat4xbACLStatusCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The counter indicates the number of times the ACE was hit by a frame. " ::= { sm24tat4xbACLStatusEntry 12 } sm24tat4xbACLStatusConflict OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the hardware status of the specific ACE. The specific ACE is not applied to the hardware due to hardware limitations. " ::= { sm24tat4xbACLStatusEntry 13 } -- ======================================================================================================================= -- sm24tat4xbAclConformance -- ======================================================================================================================= sm24tat4xbAclConformance OBJECT IDENTIFIER ::= { sm24tat4xbACL 200 } sm24tat4xbAclCompliances OBJECT IDENTIFIER ::= { sm24tat4xbAclConformance 1 } sm24tat4xbAclGroups OBJECT IDENTIFIER ::= { sm24tat4xbAclConformance 2 } sm24tat4xbACLPortConfGroup OBJECT-GROUP OBJECTS { -- sm24tat4xbACLPortConfTable sm24tat4xbACLPortConfPolicyID, sm24tat4xbACLPortConfAction, sm24tat4xbACLPortConfRateLimiterID, sm24tat4xbACLPortConfPortRedirect, sm24tat4xbACLPortConfMirror, sm24tat4xbACLPortConfLogging, sm24tat4xbACLPortConfShutdown, sm24tat4xbACLPortConfState, sm24tat4xbACLPortConfCounter } STATUS current DESCRIPTION "The collection of objects which are used to indicate sm24tat4xb ACL information." ::= { sm24tat4xbAclGroups 1 } sm24tat4xbACLRateLimiterGroup OBJECT-GROUP OBJECTS { -- sm24tat4xbACLRateLimiterTable sm24tat4xbACLRateLimiterRate, sm24tat4xbACLRateLimiterUnit } STATUS current DESCRIPTION "The collection of objects which are used to indicate sm24tat4xb ACL information." ::= { sm24tat4xbAclGroups 2 } sm24tat4xbACLACEGroup OBJECT-GROUP OBJECTS { -- sm24tat4xbACLACEClear sm24tat4xbACLACEClear, -- sm24tat4xbACLACETable sm24tat4xbACLACEID, sm24tat4xbACLACENextID, -- sm24tat4xbACLACELoopUp, sm24tat4xbACLACEIngressPort, sm24tat4xbACLACEPortPolicyNumber, sm24tat4xbACLACEPortPolicyBitmask, sm24tat4xbACLACEFrameType, sm24tat4xbACLACEAction, sm24tat4xbACLACEFilterPort, sm24tat4xbACLACEDenyPortRedirect, sm24tat4xbACLACERateLimiter, sm24tat4xbACLACEMirror, sm24tat4xbACLACELogging, sm24tat4xbACLACEShutdown, sm24tat4xbACLACECounter, sm24tat4xbACLACEVLAN8021QTagged, sm24tat4xbACLACEVLANVID, sm24tat4xbACLACEVLANTagPriority, sm24tat4xbACLACESMAC, sm24tat4xbACLACEDMACType, sm24tat4xbACLACEDMAC, sm24tat4xbACLACEEtherType, sm24tat4xbACLACEArpOpCode, sm24tat4xbACLACEArpFlagsRequestReply, sm24tat4xbACLACEArpFlagsArpSMac, sm24tat4xbACLACEArpFlagsRarpDmac, sm24tat4xbACLACEArpFlagsLength, sm24tat4xbACLACEArpFlagsIp, sm24tat4xbACLACEArpFlagsEthernet, sm24tat4xbACLACESIPType, sm24tat4xbACLACESIPIPAddress, sm24tat4xbACLACESIPIPMask, sm24tat4xbACLACEDIPType, sm24tat4xbACLACEDIPIPAddress, sm24tat4xbACLACEDIPIPMask, sm24tat4xbACLACEIPProtocol, sm24tat4xbACLACEIPProtocolValue, sm24tat4xbACLACEIPFlagsTTL, sm24tat4xbACLACEIPFlagsFragment, sm24tat4xbACLACEIPFlagsOptions, sm24tat4xbACLACEICMPType, sm24tat4xbACLACEICMPCode, sm24tat4xbACLACESourcePort, sm24tat4xbACLACEDestPort, sm24tat4xbACLACETCPFlagsFin, sm24tat4xbACLACETCPFlagsSyn, sm24tat4xbACLACETCPFlagsRst, sm24tat4xbACLACETCPFlagsPsh, sm24tat4xbACLACETCPFlagsAck, sm24tat4xbACLACETCPFlagsUrg, sm24tat4xbACLACEIPv6SIPAddress, sm24tat4xbACLACEIPv6SIPBitmask, sm24tat4xbACLACEIPv6HopLimit, sm24tat4xbACLACERowStatus } STATUS current DESCRIPTION "The collection of objects which are used to indicate sm24tat4xb ACL information." ::= { sm24tat4xbAclGroups 3 } sm24tat4xbACLStatusGroup OBJECT-GROUP OBJECTS { -- sm24tat4xbACLStatusTable sm24tat4xbACLStatusUser, sm24tat4xbACLStatusID, sm24tat4xbACLStatusIngressPort, sm24tat4xbACLStatusFrameType, sm24tat4xbACLStatusAction, sm24tat4xbACLStatusRateLimiter, sm24tat4xbACLStatusPortRedirect, sm24tat4xbACLStatusMirror, sm24tat4xbACLStatusCPU, sm24tat4xbACLStatusCPUOnce, sm24tat4xbACLStatusCounter, sm24tat4xbACLStatusConflict } STATUS current DESCRIPTION "The collection of objects which are used to indicate sm24tat4xb ACL information." ::= { sm24tat4xbAclGroups 4 } -- ======================================================================================================================= -- ======================================================================================================================= -- RowStatus Info: createAndGo, notReady not supported. -- ======================================================================================================================= -- Textual Conventions for the sm24tat4xb Qos Mib -- ======================================================================================================================= -- sm24tat4xbQosConf OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 10 } sm24tat4xbQos OBJECT IDENTIFIER ::= { sm24tat4xbQosConf 1 } sm24tat4xbQosPortClassification OBJECT IDENTIFIER ::= { sm24tat4xbQos 1 } sm24tat4xbQosPortPolicing OBJECT IDENTIFIER ::= { sm24tat4xbQos 2 } -- sm24tat4xbQosQueuePolicing OBJECT IDENTIFIER ::= { sm24tat4xbQos 3 } -- sm24tat4xbQosPortScheduler OBJECT IDENTIFIER ::= { sm24tat4xbQos 4 } sm24tat4xbQosEgressPortPCPRemarking OBJECT IDENTIFIER ::= { sm24tat4xbQos 6 } sm24tat4xbQosPortDSCP OBJECT IDENTIFIER ::= { sm24tat4xbQos 7 } sm24tat4xbQosDSCPBasedQoS OBJECT IDENTIFIER ::= { sm24tat4xbQos 8 } sm24tat4xbQosDSCPTranslation OBJECT IDENTIFIER ::= { sm24tat4xbQos 9 } sm24tat4xbQosDSCPClassification OBJECT IDENTIFIER ::= { sm24tat4xbQos 10 } sm24tat4xbQosControlList OBJECT IDENTIFIER ::= { sm24tat4xbQos 11 } sm24tat4xbQosStormControl OBJECT IDENTIFIER ::= { sm24tat4xbQos 12 } sm24tat4xbQosPortStormControl OBJECT IDENTIFIER ::= { sm24tat4xbQos 13 } sm24tat4xbQosWRED OBJECT IDENTIFIER ::= { sm24tat4xbQos 14 } sm24tat4xbQosQCLStatus OBJECT IDENTIFIER ::= { sm24tat4xbQos 15 } sm24tat4xbQosPortShapers OBJECT IDENTIFIER ::= { sm24tat4xbQos 16 } sm24tat4xbQosPortSchedulers OBJECT IDENTIFIER ::= { sm24tat4xbQos 17 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosPortClassification group -- ======================================================================================================================= --sm24tat4xbQosPortClassificationTable sm24tat4xbQosPortClassificationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosPortClassificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "QoS Ingress Port Classification. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortClassification 1 } sm24tat4xbQosPortClassificationEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosPortClassificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Port Classification Table." INDEX { ifIndex } ::= { sm24tat4xbQosPortClassificationTable 1 } SM24TAT4XBQosPortClassificationEntry ::= SEQUENCE { sm24tat4xbQosPortClassificationQoSClass Integer32, sm24tat4xbQosPortClassificationDPlevel Integer32, sm24tat4xbQosPortClassificationPCP Integer32, sm24tat4xbQosPortClassificationDEI Integer32, sm24tat4xbQosPortClassificationPCPClassification AdminMode, sm24tat4xbQosPortClassificationDSCPBased AdminMode, -- sm24tat4xbQosPortClassificationQCLAddr INTEGER, -- sm24tat4xbQosPortClassificationKeyType KeyType, sm24tat4xbQosPortClassificationWredGroup Integer32 } sm24tat4xbQosPortClassificationQoSClass OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the default QoS class, i.e., the QoS class for frames not classified in any way. There is a one to one mapping between QoS class, queue and priority. A QoS class of 0 (zero) has the lowest priority. NOTe: If the QoS class has been dynamically changed, then the actual QoS class is shown in parentheses after the configured QoS class. range: 0~7, default: 0." ::= { sm24tat4xbQosPortClassificationEntry 2 } sm24tat4xbQosPortClassificationDPlevel OBJECT-TYPE SYNTAX Integer32(0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "DP level for frames not classified in any way. range: 0~3, default: 0." ::= { sm24tat4xbQosPortClassificationEntry 3 } sm24tat4xbQosPortClassificationPCP OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority Code Point. It is a 3-bit field storing the priority level for the 802.1Q frame. range: 0~7, default: 0. " ::= { sm24tat4xbQosPortClassificationEntry 4 } sm24tat4xbQosPortClassificationDEI OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Drop Eligible Indicator. It is a 1-bit field in the VLAN. range 0~1, default: 0. " ::= { sm24tat4xbQosPortClassificationEntry 5 } sm24tat4xbQosPortClassificationPCPClassification OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the classification mode for tagged frames. " DEFVAL { disable } ::= { sm24tat4xbQosPortClassificationEntry 6 } sm24tat4xbQosPortClassificationDSCPBased OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Click to Enable DSCP Based QoS Ingress Port Classification." DEFVAL { disable } ::= { sm24tat4xbQosPortClassificationEntry 7 } -- sm24tat4xbQosPortClassificationQCLAddr OBJECT-TYPE -- SYNTAX INTEGER { sMacSip(0), dMacDip (1) } -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the QCL address matching mode. -- 0: SMAC/SIP, -- 1: DMAC/DIP, -- default: SMAC/SIP. -- Only support SPARX_III." -- DEFVAL { sMacSip } -- ::= { sm24tat4xbQosPortClassificationEntry 8 } -- sm24tat4xbQosPortClassificationKeyType OBJECT-TYPE -- SYNTAX KeyType -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "The key type specifying the key generated for frames received -- on the port. -- 0: Normal, Half key, match outer tag, SIP/DIP and SMAC/DMAC. -- 1: Double Tag: Quarter key, match inner and outer tag. -- 2: IP Address: Half key, match inner and outer tag, SIP and -- DIP. For non-IP frames, match outer tag only. -- 3: MAC and IP Address: Full key, match inner and outer tag, -- SMAC, DMAC, SIP and DIP. -- Only support on SERVAL version." -- DEFVAL { normal } -- ::= { sm24tat4xbQosPortClassificationEntry 9 } sm24tat4xbQosPortClassificationWredGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the WRED group membership. Range:1-3." ::= { sm24tat4xbQosPortClassificationEntry 10 } --sm24tat4xbQoSIngressPortTagClassificationTable sm24tat4xbQoSIngressPortTagClassificationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQoSIngressPortTagClassificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Show QoS Ingress Port Tag Classification. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortClassification 2 } sm24tat4xbQoSIngressPortTagClassificationEntry OBJECT-TYPE SYNTAX SM24TAT4XBQoSIngressPortTagClassificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "QoS Ingress Port Tag Classification entry." INDEX { ifIndex, sm24tat4xbQoSIngressPortTagPCP, sm24tat4xbQoSIngressPortTagDEI } ::= { sm24tat4xbQoSIngressPortTagClassificationTable 1 } SM24TAT4XBQoSIngressPortTagClassificationEntry ::= SEQUENCE { sm24tat4xbQoSIngressPortTagPCP INTEGER, sm24tat4xbQoSIngressPortTagDEI INTEGER, sm24tat4xbQoSIngressPortTagQosClass Integer32, sm24tat4xbQoSIngressPortTagDPLevel Integer32 } sm24tat4xbQoSIngressPortTagPCP OBJECT-TYPE SYNTAX INTEGER { pcp0(1), pcp1(2), pcp2(3), pcp3(4), pcp4(5), pcp5(6), pcp6(7), pcp7(8) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "range: 1-8, PCP0:1, PCP1:2..." ::= { sm24tat4xbQoSIngressPortTagClassificationEntry 2 } sm24tat4xbQoSIngressPortTagDEI OBJECT-TYPE SYNTAX INTEGER { dei0(1), dei1(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ingress Port Tag dei, DEI0:1, DEI1:2." ::= { sm24tat4xbQoSIngressPortTagClassificationEntry 3 } sm24tat4xbQoSIngressPortTagQosClass OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "range: 0-7." ::= { sm24tat4xbQoSIngressPortTagClassificationEntry 4 } sm24tat4xbQoSIngressPortTagDPLevel OBJECT-TYPE SYNTAX Integer32(0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "range: 0-3." ::= { sm24tat4xbQoSIngressPortTagClassificationEntry 5 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosPortPolicing group -- ======================================================================================================================= --sm24tat4xbQosPortPolicingTable sm24tat4xbQosPortPolicingTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosPortPolicingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Policer settings. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortPolicing 1 } sm24tat4xbQosPortPolicingEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosPortPolicingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Policer setting entry." INDEX { ifIndex } ::= { sm24tat4xbQosPortPolicingTable 1 } SM24TAT4XBQosPortPolicingEntry ::= SEQUENCE { sm24tat4xbQosPortPolicingEnabled AdminMode, sm24tat4xbQosPortPolicingRate Integer32, sm24tat4xbQosPortPolicingUnit Integer32, sm24tat4xbQosPortPolicingFlowControl AdminMode } sm24tat4xbQosPortPolicingEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the policer is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortPolicingEntry 2 } sm24tat4xbQosPortPolicingRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the rate for the policer. default: 500(kbps)." ::= { sm24tat4xbQosPortPolicingEntry 3 } sm24tat4xbQosPortPolicingUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the policer rate. 0: kbps 1: Mbps 2: fps 3: kfps " ::= { sm24tat4xbQosPortPolicingEntry 4 } sm24tat4xbQosPortPolicingFlowControl OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "If flow control is enabled and the port is in flow control mode, then pause frames are sent instead of discarding frames." DEFVAL { disable } ::= { sm24tat4xbQosPortPolicingEntry 5 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosQueuePolicing group -- ======================================================================================================================= --sm24tat4xbQosQueuePolicingTable -- sm24tat4xbQosQueuePolicingTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBQosQueuePolicingEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "The Queue Policer settings. -- INDEX for this table is ifIndex which is -- equivalent to the panel port number." -- ::= { sm24tat4xbQosQueuePolicing 1 } -- -- sm24tat4xbQosQueuePolicingEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBQosQueuePolicingEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "The Qos Queue Policing Entry." -- INDEX { ifIndex } -- ::= { sm24tat4xbQosQueuePolicingTable 1 } -- -- SM24TAT4XBQosQueuePolicingEntry ::= SEQUENCE { -- sm24tat4xbQosQueuePolicingQueue0Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue0Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue0Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue1Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue1Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue1Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue2Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue2Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue2Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue3Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue3Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue3Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue4Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue4Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue4Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue5Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue5Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue5Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue6Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue6Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue6Unit Integer32, -- sm24tat4xbQosQueuePolicingQueue7Enable AdminMode, -- sm24tat4xbQosQueuePolicingQueue7Rate Integer32, -- sm24tat4xbQosQueuePolicingQueue7Unit Integer32 -- } -- -- sm24tat4xbQosQueuePolicingQueue0Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 0 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 3 } -- -- sm24tat4xbQosQueuePolicingQueue0Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 0 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 4 } -- -- sm24tat4xbQosQueuePolicingQueue0Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 5 } -- -- sm24tat4xbQosQueuePolicingQueue1Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 1 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 6 } -- -- sm24tat4xbQosQueuePolicingQueue1Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 1 policer is enabled on this switch port., -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 7 } -- -- sm24tat4xbQosQueuePolicingQueue1Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 8 } -- -- sm24tat4xbQosQueuePolicingQueue2Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 2 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 9 } -- -- sm24tat4xbQosQueuePolicingQueue2Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 2 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 10 } -- -- sm24tat4xbQosQueuePolicingQueue2Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 11 } -- -- sm24tat4xbQosQueuePolicingQueue3Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 3 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 12 } -- -- sm24tat4xbQosQueuePolicingQueue3Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 3 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 13 } -- -- sm24tat4xbQosQueuePolicingQueue3Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 14 } -- -- sm24tat4xbQosQueuePolicingQueue4Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 4 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 15 } -- -- sm24tat4xbQosQueuePolicingQueue4Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 4 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 16 } -- -- sm24tat4xbQosQueuePolicingQueue4Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 17 } -- -- sm24tat4xbQosQueuePolicingQueue5Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 5 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 18 } -- -- sm24tat4xbQosQueuePolicingQueue5Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 5 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 19 } -- -- sm24tat4xbQosQueuePolicingQueue5Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 20 } -- -- sm24tat4xbQosQueuePolicingQueue6Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 6 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 21 } -- -- sm24tat4xbQosQueuePolicingQueue6Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 6 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 22 } -- -- sm24tat4xbQosQueuePolicingQueue6Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 23 } -- -- sm24tat4xbQosQueuePolicingQueue7Enable OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 7 policer is enabled on this switch port." -- DEFVAL { disable } -- ::= { sm24tat4xbQosQueuePolicingEntry 24 } -- -- sm24tat4xbQosQueuePolicingQueue7Rate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the queue 7 policer is enabled on this switch port. -- default: 500(Kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 25 } -- -- sm24tat4xbQosQueuePolicingQueue7Unit OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the unit of measure for the queue policer rate as kbps or Mbps. -- range: -- 0:kbs -- 1:Mbps -- default: 0(kbps)" -- ::= { sm24tat4xbQosQueuePolicingEntry 26 } -- -- -- ======================================================================================================================= -- Start sm24tat4xbQosPortScheduler group -- ======================================================================================================================= --sm24tat4xbQosPortSchedulerModeTable -- sm24tat4xbQosPortSchedulerModeTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBQosPortSchedulerModeEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "The basic QoS Port Scheduler Mode settings. -- INDEX for this table is ifIndex which is -- equivalent to the panel port number." -- ::= { sm24tat4xbQosPortScheduler 1 } -- -- sm24tat4xbQosPortSchedulerModeEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBQosPortSchedulerModeEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "The Qos Port Scheduler Mode entry." -- INDEX { ifIndex } -- ::= { sm24tat4xbQosPortSchedulerModeTable 1 } -- -- SM24TAT4XBQosPortSchedulerModeEntry ::= SEQUENCE { -- sm24tat4xbQosSchedulerMode Integer32, -- sm24tat4xbQosSchedulerShaper AdminMode, -- sm24tat4xbQosSchedulerShaperRate Integer32 -- } -- -- sm24tat4xbQosSchedulerMode OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the scheduler mode is Strict Priority or Weighted -- on this switch port. -- 0:Strict Priority, -- 2: 2 Queues Weighted -- 3: 3 Queues Weighted: only Jaguar2 support -- 4: 4 Queues Weighted: only Jaguar2 support -- 5: 5 Queues Weighted: only Jaguar2 support -- 6: 6 Queues Weighted -- 7: 7 Queues Weighted: only Jaguar2 support -- 8: 8 Queues Weighted: only Jaguar2 support" -- ::= { sm24tat4xbQosPortSchedulerModeEntry 2 } -- -- sm24tat4xbQosSchedulerShaper OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls whether the port shaper is enabled." -- DEFVAL { disable } -- ::= { sm24tat4xbQosPortSchedulerModeEntry 3 } -- -- sm24tat4xbQosSchedulerShaperRate OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Controls the rate for the port shaper. -- default: 500 kbps." -- ::= { sm24tat4xbQosPortSchedulerModeEntry 4 } -- --sm24tat4xbQosPortSchedulerTable -- sm24tat4xbQosPortSchedulerTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBQosPortSchedulerEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Show Qos Port Scheduler. -- INDEX for this table is ifIndex which is -- equivalent to the panel port number." -- ::= { sm24tat4xbQosPortScheduler 2 } -- -- sm24tat4xbQosPortSchedulerEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBQosPortSchedulerEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "The Qos Port Scheduler Entry." -- INDEX { ifIndex, -- sm24tat4xbQosSchedulerPortQueue} -- ::= { sm24tat4xbQosPortSchedulerTable 1 } -- -- SM24TAT4XBQosPortSchedulerEntry ::= SEQUENCE { -- sm24tat4xbQosSchedulerPortQueue INTEGER, -- sm24tat4xbQosSchedulerPortQueueShaper AdminMode, -- sm24tat4xbQosSchedulerPortQueueShaperRate Integer32, -- sm24tat4xbQosSchedulerPortQueueShaperExcess AdminMode, -- sm24tat4xbQosSchedulerPortQueueSchedulerWeight Integer32, -- sm24tat4xbQosSchedulerPortQueueSchedulerPercent DisplayString -- } -- -- sm24tat4xbQosSchedulerPortQueue OBJECT-TYPE -- SYNTAX INTEGER { q0(1), -- q1(2), -- q2(3), -- q3(4), -- q4(5), -- q5(6), -- q6(7), -- q7(8) } -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "range: 1-8. -- Q0: 1, Q1: 2, ..." -- ::= { sm24tat4xbQosPortSchedulerEntry 2 } -- -- sm24tat4xbQosSchedulerPortQueueShaper OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Qos scheduler admin state." -- DEFVAL { disable } -- ::= { sm24tat4xbQosPortSchedulerEntry 3 } -- -- sm24tat4xbQosSchedulerPortQueueShaperRate OBJECT-TYPE -- SYNTAX Integer32(100..1000000) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "range: 100..1000000 kbps. " -- ::= { sm24tat4xbQosPortSchedulerEntry 4 } -- -- sm24tat4xbQosSchedulerPortQueueShaperExcess OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "admin state sm24tat4xbQosSchedulerPortQueueShaperExcess" -- DEFVAL { disable } -- ::= { sm24tat4xbQosPortSchedulerEntry 5 } -- -- sm24tat4xbQosSchedulerPortQueueSchedulerWeight OBJECT-TYPE -- SYNTAX Integer32(0..100) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "range: 1-100, -- default: 17. -- Only use in Q0 - Q5. Q6 & Q7 show 0" -- ::= { sm24tat4xbQosPortSchedulerEntry 6 } -- -- sm24tat4xbQosSchedulerPortQueueSchedulerPercent OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Only use in Q0 - Q5. Q6 & Q7 show empty" -- ::= { sm24tat4xbQosPortSchedulerEntry 7 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosEgressPortPCPRemarking group -- ======================================================================================================================= --sm24tat4xbQosEgressPortPCPRemarkingTable sm24tat4xbQosEgressPortPCPRemarkingTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosEgressPortPCPRemarkingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic Qos Egress Port PCP Remarking Configuration settings. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosEgressPortPCPRemarking 1 } sm24tat4xbQosEgressPortPCPRemarkingEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosEgressPortPCPRemarkingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Egress Port PCP Remarking Entry." INDEX { ifIndex } ::= { sm24tat4xbQosEgressPortPCPRemarkingTable 1 } SM24TAT4XBQosEgressPortPCPRemarkingEntry ::= SEQUENCE { sm24tat4xbQosEgressPortPCPRemarkingMode INTEGER } sm24tat4xbQosEgressPortPCPRemarkingMode OBJECT-TYPE SYNTAX INTEGER { keep(0), specific(1), mapped(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "the tag remarking mode for this port. 0:Keep, Use classified PCP/DEI values. 1:Specific, Use default PCP/DEI values. 2:Mapped, Use mapped versions of QoS class and DP level." ::= { sm24tat4xbQosEgressPortPCPRemarkingEntry 2 } --sm24tat4xbQosEgressPortPCPRemarkingSpecificTable sm24tat4xbQosEgressPortPCPRemarkingSpecificTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosEgressPortPCPRemarkingSpecificEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic Qos Egress Port PCP Remarking Specific Configuration settings. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosEgressPortPCPRemarking 2 } sm24tat4xbQosEgressPortPCPRemarkingSpecificEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosEgressPortPCPRemarkingSpecificEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Egress Port PCP Remarking Specific Entry." INDEX { ifIndex } ::= { sm24tat4xbQosEgressPortPCPRemarkingSpecificTable 1 } SM24TAT4XBQosEgressPortPCPRemarkingSpecificEntry ::= SEQUENCE { sm24tat4xbQosEgressPortPCPRemarkingSpecificPCP Integer32, sm24tat4xbQosEgressPortPCPRemarkingSpecificDEI AdminMode } sm24tat4xbQosEgressPortPCPRemarkingSpecificPCP OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the specific PCP Range : 0-7" ::= { sm24tat4xbQosEgressPortPCPRemarkingSpecificEntry 2 } sm24tat4xbQosEgressPortPCPRemarkingSpecificDEI OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "controls the admin state of DEI" ::= { sm24tat4xbQosEgressPortPCPRemarkingSpecificEntry 3 } --sm24tat4xbQosPortEgressTagRemarkingMapDPTable -- sm24tat4xbQosPortEgressTagRemarkingMapDPTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBQosPortEgressTagRemarkingMapDPEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Show Qos Port Egress Tag Remarking Map DP. -- INDEX for this table is ifIndex which is -- equivalent to the panel port number." -- ::= { sm24tat4xbQosPortEgressTagRemarking 3 } -- sm24tat4xbQosPortEgressTagRemarkingMapDPEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBQosPortEgressTagRemarkingMapDPEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "The Qos Port Egress Tag Remarking Map DP Entry." -- INDEX { ifIndex, -- sm24tat4xbQosPortEgressTagRemarkingClassifiedDPLevel} -- ::= { sm24tat4xbQosPortEgressTagRemarkingMapDPTable 1 } -- SM24TAT4XBQosPortEgressTagRemarkingMapDPEntry ::= SEQUENCE { -- sm24tat4xbQosPortEgressTagRemarkingClassifiedDPLevel Integer32, -- sm24tat4xbQosPortEgressTagRemarkingDPLevel AdminMode -- } -- sm24tat4xbQosPortEgressTagRemarkingClassifiedDPLevel OBJECT-TYPE -- SYNTAX Integer32(1..4) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "range: 1-4." -- ::= { sm24tat4xbQosPortEgressTagRemarkingMapDPEntry 2 } -- sm24tat4xbQosPortEgressTagRemarkingDPLevel OBJECT-TYPE -- SYNTAX AdminMode -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "admin state of Tag remark" -- ::= { sm24tat4xbQosPortEgressTagRemarkingMapDPEntry 3 } --sm24tat4xbQosEgressPortPCPRemarkingMappedTable sm24tat4xbQosEgressPortPCPRemarkingMappedTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosEgressPortPCPRemarkingMappedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Show Qos Egress Port PCP Remarking Mapped. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosEgressPortPCPRemarking 4 } sm24tat4xbQosEgressPortPCPRemarkingMappedEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosEgressPortPCPRemarkingMappedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Egress Port PCP Remarking Mapped Entry." INDEX { ifIndex, sm24tat4xbQosEgressPortPCPRemarkingMappedQueuePriority, sm24tat4xbQosEgressPortPCPRemarkingMappedDPLevel } ::= { sm24tat4xbQosEgressPortPCPRemarkingMappedTable 1 } SM24TAT4XBQosEgressPortPCPRemarkingMappedEntry ::= SEQUENCE { sm24tat4xbQosEgressPortPCPRemarkingMappedQueuePriority INTEGER, sm24tat4xbQosEgressPortPCPRemarkingMappedDPLevel INTEGER, sm24tat4xbQosEgressPortPCPRemarkingMappedPCP Integer32, sm24tat4xbQosEgressPortPCPRemarkingMappedDEI Integer32 } sm24tat4xbQosEgressPortPCPRemarkingMappedQueuePriority OBJECT-TYPE SYNTAX INTEGER { class0(1), class1(2), class2(3), class3(4), class4(5), class5(6), class6(7), class7(8) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "range: 1-8, QoS Class0: 1, QoS Class1: 2..." ::= { sm24tat4xbQosEgressPortPCPRemarkingMappedEntry 2 } sm24tat4xbQosEgressPortPCPRemarkingMappedDPLevel OBJECT-TYPE SYNTAX INTEGER { level0(1), level1(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "range: 1-2, DP Level0: 1, DP Level1: 2." ::= { sm24tat4xbQosEgressPortPCPRemarkingMappedEntry 3 } sm24tat4xbQosEgressPortPCPRemarkingMappedPCP OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "range: 0-7." ::= { sm24tat4xbQosEgressPortPCPRemarkingMappedEntry 4 } sm24tat4xbQosEgressPortPCPRemarkingMappedDEI OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "range: 0-1." ::= { sm24tat4xbQosEgressPortPCPRemarkingMappedEntry 5 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosPortDSCP group -- ======================================================================================================================= --sm24tat4xbQosPortDSCPTable sm24tat4xbQosPortDSCPTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosPortDSCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic QoS Port DSCP Configuration settings. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortDSCP 1 } sm24tat4xbQosPortDSCPEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosPortDSCPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Port DSCP Entry." INDEX { ifIndex } ::= { sm24tat4xbQosPortDSCPTable 1 } SM24TAT4XBQosPortDSCPEntry ::= SEQUENCE { sm24tat4xbQosPortDSCPIngressTranslate AdminMode, sm24tat4xbQosPortDSCPIngressClassify INTEGER, sm24tat4xbQosPortDSCPEgressRewrite INTEGER } sm24tat4xbQosPortDSCPIngressTranslate OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Configure DSCP ingress translation mode." DEFVAL { disable } ::= { sm24tat4xbQosPortDSCPEntry 2 } sm24tat4xbQosPortDSCPIngressClassify OBJECT-TYPE SYNTAX INTEGER { disable (0), dscp (1), selected (2), all(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Classification for a port have 4 different values. 0: disable, 1: DSCP=0, 2: Selected, 3: All." DEFVAL { disable } ::= { sm24tat4xbQosPortDSCPEntry 3 } sm24tat4xbQosPortDSCPEgressRewrite OBJECT-TYPE SYNTAX INTEGER { disable (0),enable (1), remap (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the port egress rewriting mode. 0: Disable,1: Enable,2: Remap,range: 0-2" ::= { sm24tat4xbQosPortDSCPEntry 4 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosDSCPBasedQoS group -- ======================================================================================================================= sm24tat4xbQosDSCPBasedQoSTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosDSCPBasedQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "configure the basic Qos DSCP-Based QoS Ingress Classification settings for all switches." ::= { sm24tat4xbQosDSCPBasedQoS 1 } sm24tat4xbQosDSCPBasedQoSEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosDSCPBasedQoSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos DSCP Based QoS Entry." INDEX { sm24tat4xbQosDSCPBasedQoSList } ::= { sm24tat4xbQosDSCPBasedQoSTable 1 } SM24TAT4XBQosDSCPBasedQoSEntry ::= SEQUENCE { sm24tat4xbQosDSCPBasedQoSList Integer32, sm24tat4xbQosDSCPBasedQoSDSCP DisplayString, sm24tat4xbQosDSCPBasedQoSTrust AdminMode, sm24tat4xbQosDSCPBasedQoSQueuePriority Integer32, sm24tat4xbQosDSCPBasedQoSDPL Integer32 } sm24tat4xbQosDSCPBasedQoSList OBJECT-TYPE SYNTAX Integer32(1..64) MAX-ACCESS not-accessible STATUS current DESCRIPTION "DSCP mapping table index(1-64)." ::= { sm24tat4xbQosDSCPBasedQoSEntry 1 } sm24tat4xbQosDSCPBasedQoSDSCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of supported DSCP values are 64." ::= { sm24tat4xbQosDSCPBasedQoSEntry 2 } sm24tat4xbQosDSCPBasedQoSTrust OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether a specific DSCP value is trusted. Only frames with trusted DSCP values are mapped to a specific QoS class and Drop Precedence Level. Frames with untrusted DSCP values are treated as a non-IP frame." DEFVAL { disable } ::= { sm24tat4xbQosDSCPBasedQoSEntry 3 } sm24tat4xbQosDSCPBasedQoSQueuePriority OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "QoS class. range: 0-7, default: 0." ::= { sm24tat4xbQosDSCPBasedQoSEntry 4 } sm24tat4xbQosDSCPBasedQoSDPL OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Drop Precedence Level. range: 0-1, default: 0." ::= { sm24tat4xbQosDSCPBasedQoSEntry 5 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosDSCPTranslation group -- ======================================================================================================================= --sm24tat4xbQosDSCPTranslationTable sm24tat4xbQosDSCPTranslationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosDSCPTranslationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic QoS DSCP Translation settings for all switches." ::= { sm24tat4xbQosDSCPTranslation 1 } sm24tat4xbQosDSCPTranslationEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosDSCPTranslationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos DSCP Translation Entry." INDEX { sm24tat4xbQosDSCPTranslationList } ::= { sm24tat4xbQosDSCPTranslationTable 1 } SM24TAT4XBQosDSCPTranslationEntry ::= SEQUENCE { sm24tat4xbQosDSCPTranslationList Integer32, sm24tat4xbQosDSCPTranslationDSCPBasedId DisplayString, sm24tat4xbQosDSCPTranslationIngressTranslate Integer32, sm24tat4xbQosDSCPTranslationIngressClassify AdminMode, sm24tat4xbQosDSCPTranslationEgressRemap Integer32 -- sm24tat4xbQosDSCPTranslationEgressRemapDP1 Integer32 } sm24tat4xbQosDSCPTranslationList OBJECT-TYPE SYNTAX Integer32(1..64) MAX-ACCESS not-accessible STATUS current DESCRIPTION "DSCP translation table index(1-64)." ::= { sm24tat4xbQosDSCPTranslationEntry 1 } sm24tat4xbQosDSCPTranslationDSCPBasedId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Configure global ingress DSCP translation table." ::= { sm24tat4xbQosDSCPTranslationEntry 2 } sm24tat4xbQosDSCPTranslationIngressTranslate OBJECT-TYPE SYNTAX Integer32(0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "DSCP at Ingress side can be translated to any of DSCP values. range: 0-63, default: 0." ::= { sm24tat4xbQosDSCPTranslationEntry 3 } sm24tat4xbQosDSCPTranslationIngressClassify OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Configure DSCP ingress classification." DEFVAL { disable } ::= { sm24tat4xbQosDSCPTranslationEntry 4 } sm24tat4xbQosDSCPTranslationEgressRemap OBJECT-TYPE SYNTAX Integer32(0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Select the DSCP value from select menu to which you want to remap. range: 0-63, default: 0." ::= { sm24tat4xbQosDSCPTranslationEntry 5 } -- sm24tat4xbQosDSCPTranslationEgressRemapDP1 OBJECT-TYPE -- SYNTAX Integer32(0..63) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Select the DSCP value from select menu to which you want to remap. -- range: 0-63, -- default: 0. -- Only support LUTON26." -- ::= { sm24tat4xbQosDSCPTranslationEntry 6 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosDSCPClassification group -- ======================================================================================================================= --sm24tat4xbQosDSCPClassificationTable sm24tat4xbQosDSCPClassificationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosDSCPClassificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The mapping of QoS class to DSCP value." ::= { sm24tat4xbQosDSCPClassification 1 } sm24tat4xbQosDSCPClassificationEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosDSCPClassificationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos DSCP Classification Entry." INDEX { sm24tat4xbQosDSCPClassificationQoSClass } ::= { sm24tat4xbQosDSCPClassificationTable 1 } SM24TAT4XBQosDSCPClassificationEntry ::= SEQUENCE { sm24tat4xbQosDSCPClassificationQoSClass Integer32, sm24tat4xbQosDSCPClassificationDSCPDP0 Integer32, sm24tat4xbQosDSCPClassificationDSCPDP1 Integer32, sm24tat4xbQosDSCPClassificationDSCPDP2 Integer32, sm24tat4xbQosDSCPClassificationDSCPDP3 Integer32 } sm24tat4xbQosDSCPClassificationQoSClass OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This page allows you to configure the mapping of QoS class and Drop Precedence Level to DSCP value. range: 1-8}" ::= { sm24tat4xbQosDSCPClassificationEntry 1 } sm24tat4xbQosDSCPClassificationDSCPDP0 OBJECT-TYPE SYNTAX Integer32(0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Select the classified DSCP value. range: 0-63, default: 0." ::= { sm24tat4xbQosDSCPClassificationEntry 2 } sm24tat4xbQosDSCPClassificationDSCPDP1 OBJECT-TYPE SYNTAX Integer32(0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Select the classified DSCP value. range: 0-63, default: 0." ::= { sm24tat4xbQosDSCPClassificationEntry 3 } sm24tat4xbQosDSCPClassificationDSCPDP2 OBJECT-TYPE SYNTAX Integer32(0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Select the classified DSCP value. range: 0-63, default: 0." ::= { sm24tat4xbQosDSCPClassificationEntry 4 } sm24tat4xbQosDSCPClassificationDSCPDP3 OBJECT-TYPE SYNTAX Integer32(0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Select the classified DSCP value. range: 0-63, default: 0." ::= { sm24tat4xbQosDSCPClassificationEntry 5 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosControlList group -- ======================================================================================================================= --sm24tat4xbQosQceTable sm24tat4xbQosQceTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosQceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Create Qos QCE entry." ::= { sm24tat4xbQosControlList 1 } sm24tat4xbQosQceEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosQceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Qos Qce Entry." INDEX { sm24tat4xbQosQceIndex } ::= { sm24tat4xbQosQceTable 1 } SM24TAT4XBQosQceEntry ::= SEQUENCE { sm24tat4xbQosQceIndex Integer32, sm24tat4xbQosQceID Integer32, sm24tat4xbQosQceList Integer32, -- sm24tat4xbQosQcePortMembersSwitch Integer32, sm24tat4xbQosQcePortMembers DisplayString, sm24tat4xbQosQceTag DisplayString, sm24tat4xbQosQceVID DisplayString, sm24tat4xbQosPCP DisplayString, sm24tat4xbQosDEI DisplayString, sm24tat4xbQosSMAC DisplayString, sm24tat4xbQosDMACType DisplayString, sm24tat4xbQosDMACValue DisplayString, sm24tat4xbQosQceInnerTag DisplayString, sm24tat4xbQosQceInnerVID DisplayString, sm24tat4xbQosInnerPCP DisplayString, sm24tat4xbQosInnerDEI DisplayString, sm24tat4xbQosFrameType INTEGER, sm24tat4xbQosMacEtherType DisplayString, sm24tat4xbQosLLCSSAPAddr DisplayString, sm24tat4xbQosLLCDSAPAddr DisplayString, sm24tat4xbQosLLCControl DisplayString, sm24tat4xbQosSNAPPID DisplayString, sm24tat4xbQosIpv4Protocol DisplayString, sm24tat4xbQosIpv4ProtocolValue Integer32, sm24tat4xbQosIpv4ProtocolUDPSPort DisplayString, sm24tat4xbQosIpv4ProtocolUDPDPort DisplayString, sm24tat4xbQosIpv4ProtocolTCPSPort DisplayString, sm24tat4xbQosIpv4ProtocolTCPDPort DisplayString, sm24tat4xbQosIpv4SourceIp DisplayString, sm24tat4xbQosIpv4SourceMask DisplayString, sm24tat4xbQosIpv4DestIp DisplayString, sm24tat4xbQosIpv4DestMask DisplayString, sm24tat4xbQosIpv4IPFragment INTEGER, sm24tat4xbQosIpv4DSCP DisplayString, sm24tat4xbQosIpv6Protocol DisplayString, sm24tat4xbQosIpv6ProtocolValue Integer32, sm24tat4xbQosIpv6ProtocolUDPSPort DisplayString, sm24tat4xbQosIpv6ProtocolUDPDPort DisplayString, sm24tat4xbQosIpv6ProtocolTCPSPort DisplayString, sm24tat4xbQosIpv6ProtocolTCPDPort DisplayString, sm24tat4xbQosIpv6SourceIp DisplayString, sm24tat4xbQosIpv6SourceMask DisplayString, sm24tat4xbQosIpv6DestIp DisplayString, sm24tat4xbQosIpv6DestMask DisplayString, sm24tat4xbQosIpv6DSCP DisplayString, sm24tat4xbQosActionQueuePriority Integer32, sm24tat4xbQosActionDPL Integer32, sm24tat4xbQosActionDSCP Integer32, sm24tat4xbQosActionPCP Integer32, sm24tat4xbQosActionDEI Integer32, sm24tat4xbQosActionPolicy Integer32, sm24tat4xbQosActionIngressMapID Integer32, sm24tat4xbQosQceRowStatus RowStatus } sm24tat4xbQosQceIndex OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS not-accessible STATUS current DESCRIPTION "the index to this table." ::= { sm24tat4xbQosQceEntry 1 } sm24tat4xbQosQceID OBJECT-TYPE SYNTAX Integer32(1..256) MAX-ACCESS read-only STATUS current DESCRIPTION "If the QCE ID is specified and an entry with this QCE ID already exists, the QCE will be modified. Otherwise, a new QCE will be added. range : 1 - 256." ::= { sm24tat4xbQosQceEntry 2 } sm24tat4xbQosQceList OBJECT-TYPE SYNTAX Integer32(0..256) MAX-ACCESS read-create STATUS current DESCRIPTION "If the QCE List is non zero, the QCE will be placed in the list. If the QCE List is zero, the QCE will be placed last in the list. range : 0 - 256." ::= { sm24tat4xbQosQceEntry 3 } -- sm24tat4xbQosQcePortMembersSwitch OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "Switch number for port members. -- -1:Any. -- Only support stacking switch." -- ::= { sm24tat4xbQosQceEntry 4 } sm24tat4xbQosQcePortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the ingress port of the QCE. Possible values are: All: The QCE will match all ingress port. Port: The QCE will match a specific ingress port.Format: 1,3-6." ::= { sm24tat4xbQosQceEntry 5 } sm24tat4xbQosQceTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "'Any', 'Untagged' or 'Tagged' or 'C-Tag' or 'S-Tag'" ::= { sm24tat4xbQosQceEntry 6 } sm24tat4xbQosQceVID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid value of VLAN ID can be any value in 'Specific 1~4095' or 'range 1-4095' or 'Any'." ::= { sm24tat4xbQosQceEntry 7 } sm24tat4xbQosPCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Priority Code Point: Valid value PCP are specific(0, 1, 2, 3, 4, 5, 6, 7) or range(0-1, 2-3, 4-5, 6-7, 0-3, 4-7) or 'Any'." ::= { sm24tat4xbQosQceEntry 8 } sm24tat4xbQosDEI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Drop Eligible Indicator: Valid value of DEI can be any of values between 0, 1 or 'Any'." ::= { sm24tat4xbQosQceEntry 9 } sm24tat4xbQosSMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Source MAC address: xx-xx-xx-xx-xx-xx or 'Any'." ::= { sm24tat4xbQosQceEntry 10 } sm24tat4xbQosDMACType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Destination MAC type: possible values are 'UC'(unicast), 'MC'(multicast), 'BC'(broadcast), 'SP'(Specific) or 'Any'." ::= { sm24tat4xbQosQceEntry 11 } sm24tat4xbQosDMACValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "when QosDMACType is 'SP'(specific) can set mac address. " ::= { sm24tat4xbQosQceEntry 12 } sm24tat4xbQosQceInnerTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Value of Inner Tag field can be 'Any', 'Untagged' or 'Tagged' or 'C-tagged' or 'S-tagged'." ::= { sm24tat4xbQosQceEntry 13 } sm24tat4xbQosQceInnerVID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid value of Inner VLAN ID can be any value in 'Specific 1~4095' or 'range 1-4095' or 'Any'. " ::= { sm24tat4xbQosQceEntry 14 } sm24tat4xbQosInnerPCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid value Inner PCP are specific(0, 1, 2, 3, 4, 5, 6, 7) or range(0-1, 2-3, 4-5, 6-7, 0-3, 4-7) or 'Any'. " ::= { sm24tat4xbQosQceEntry 15 } sm24tat4xbQosInnerDEI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid value of Inner DEI can be any of values between 0, 1 or 'Any'. " ::= { sm24tat4xbQosQceEntry 16 } sm24tat4xbQosFrameType OBJECT-TYPE SYNTAX INTEGER { any(1), ethernet(2), llc(3), snap(4), ipv4(5), ipv6(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "Frame Type can have any of the following values: 1: Any, 2: Ethernet, 3: LLC, 4: SNAP, 5: IPv4, 6: IPv6." ::= { sm24tat4xbQosQceEntry 17 } sm24tat4xbQosMacEtherType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid ethernet type can have a value within 0x600-0xFFFF or 'Any' , but excluding 0x800(IPv4) and 0x86DD(IPv6), range: 0000-FFFF, default: Any." ::= { sm24tat4xbQosQceEntry 18 } sm24tat4xbQosLLCSSAPAddr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid SSAP(Source Service Access Point) can vary from 0x00 to 0xFF or 'Any', range: 00-FF, default: Any." ::= { sm24tat4xbQosQceEntry 19 } sm24tat4xbQosLLCDSAPAddr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid DSAP(Destination Service Access Point) can vary from 0x00 to 0xFF or 'Any', range: 00-FF, default: Any." ::= { sm24tat4xbQosQceEntry 20 } sm24tat4xbQosLLCControl OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid Control field can vary from 0x00 to 0xFF or 'Any', range: 00-FF, default: Any." ::= { sm24tat4xbQosQceEntry 21 } sm24tat4xbQosSNAPPID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Valid PID(a.k.a ethernet type) can have value within 0x00-0xFFFF or 'Any', range: 0000-FFFF, default: Any." ::= { sm24tat4xbQosQceEntry 22 } sm24tat4xbQosIpv4Protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IP protocol number: (Other, TCP or UDP) or 'Any'." ::= { sm24tat4xbQosQceEntry 23 } sm24tat4xbQosIpv4ProtocolValue OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Ipv4 Protocol is Other. range: 0-255 default: 0." ::= { sm24tat4xbQosQceEntry 24 } sm24tat4xbQosIpv4ProtocolUDPSPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Source TCP/UDP Port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 25 } sm24tat4xbQosIpv4ProtocolUDPDPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Destination TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 26 } sm24tat4xbQosIpv4ProtocolTCPSPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Source TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 27 } sm24tat4xbQosIpv4ProtocolTCPDPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Destination TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 28 } sm24tat4xbQosIpv4SourceIp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Specific Source IP address in value format or value 0.0.0.0 is 'Any'. if Ipv4 Mask value 0.0.0.0 is 'Any' ,IP address value also is 'Any'. (x.y.z.w),x=0 unless y.z.w also 0,x not is 127 or greater than 223." ::= { sm24tat4xbQosQceEntry 29 } sm24tat4xbQosIpv4SourceMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Specific Source IP address in mask format or value 0.0.0.0 is 'Any'." ::= { sm24tat4xbQosQceEntry 30 } sm24tat4xbQosIpv4DestIp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Specific Destination IP address in value format or value 0.0.0.0 is 'Any'. if Ipv4 Mask value 0.0.0.0 is 'Any' ,IP address value also is 'Any'. (x.y.z.w),x=0 unless y.z.w also 0,x not is 127 or greater than 223." ::= { sm24tat4xbQosQceEntry 31 } sm24tat4xbQosIpv4DestMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Specific Destination IP address in mask format or value 0.0.0.0 is 'Any'." ::= { sm24tat4xbQosQceEntry 32 } sm24tat4xbQosIpv4IPFragment OBJECT-TYPE SYNTAX INTEGER { any(0), no(1), yes(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "IPv4 frame fragmented option: 2: yes, 1: no, 0: any." ::= { sm24tat4xbQosQceEntry 33 } sm24tat4xbQosIpv4DSCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Diffserv Code Point value (DSCP): It can be a specific value, range of values or 'Any'. DSCP values are in the range 0-63." ::= { sm24tat4xbQosQceEntry 34 } sm24tat4xbQosIpv6Protocol OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IP protocol number: (Other, TCP or UDP) or 'Any'." ::= { sm24tat4xbQosQceEntry 35 } sm24tat4xbQosIpv6ProtocolValue OBJECT-TYPE SYNTAX Integer32(0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "when IPv6 protocol is Other , range: 0-255." ::= { sm24tat4xbQosQceEntry 36 } sm24tat4xbQosIpv6ProtocolUDPSPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Source TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 37 } sm24tat4xbQosIpv6ProtocolUDPDPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Destination TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 38 } sm24tat4xbQosIpv6ProtocolTCPSPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Source TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 39 } sm24tat4xbQosIpv6ProtocolTCPDPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Destination TCP/UDP port:(0-65535) or 'Any', specific or port range applicable for IP protocol UDP/TCP." ::= { sm24tat4xbQosQceEntry 40 } sm24tat4xbQosIpv6SourceIp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IPv6 source address: (a.b.c.d) or value 0.0.0.0 is 'Any', 32 LS bits." ::= { sm24tat4xbQosQceEntry 41 } sm24tat4xbQosIpv6SourceMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IPv6 mask address: (a.b.c.d) or value 0.0.0.0 is 'Any', 32 LS bits." ::= { sm24tat4xbQosQceEntry 42 } sm24tat4xbQosIpv6DestIp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IPv6 destination address: (a.b.c.d) or value 0.0.0.0 is 'Any', 32 LS bits." ::= { sm24tat4xbQosQceEntry 43 } sm24tat4xbQosIpv6DestMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IPv6 mask address: (a.b.c.d) or value 0.0.0.0 is 'Any', 32 LS bits." ::= { sm24tat4xbQosQceEntry 44 } sm24tat4xbQosIpv6DSCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Diffserv Code Point value (DSCP): It can be a specific value, range of values or 'Any'. DSCP values are in the range 0-63 including BE, CS1-CS7, EF or AF11-AF43." ::= { sm24tat4xbQosQceEntry 45 } sm24tat4xbQosActionQueuePriority OBJECT-TYPE SYNTAX Integer32(0..8) MAX-ACCESS read-create STATUS current DESCRIPTION "QoS class: (0-7) or 8: Default." ::= { sm24tat4xbQosQceEntry 46 } sm24tat4xbQosActionDPL OBJECT-TYPE SYNTAX Integer32 (0..4) MAX-ACCESS read-create STATUS current DESCRIPTION "range:0-4. 4: Default" ::= { sm24tat4xbQosQceEntry 47 } sm24tat4xbQosActionDSCP OBJECT-TYPE SYNTAX Integer32(0..64) MAX-ACCESS read-create STATUS current DESCRIPTION "Valid DSCP value can be (0-63, BE, CS1-CS7, EF or AF11-AF43) or 64: Default." ::= { sm24tat4xbQosQceEntry 48 } sm24tat4xbQosActionPCP OBJECT-TYPE SYNTAX Integer32(0..8) MAX-ACCESS read-create STATUS current DESCRIPTION "pcp: (0-7) or 8: Default. " ::= { sm24tat4xbQosQceEntry 49 } sm24tat4xbQosActionDEI OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-create STATUS current DESCRIPTION "dei: (0-1) or 2: Default. " ::= { sm24tat4xbQosQceEntry 50 } sm24tat4xbQosActionPolicy OBJECT-TYPE SYNTAX Integer32(0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "ACL Policy number: (0-127) or 'empty'(128). Default: empty. " ::= { sm24tat4xbQosQceEntry 51 } sm24tat4xbQosActionIngressMapID OBJECT-TYPE SYNTAX Integer32(-1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Classify Ingress Map ID: Range: 0-255 Default: -1 " ::= { sm24tat4xbQosQceEntry 52 } sm24tat4xbQosQceRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbQosQceEntry 53 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosStormControl group -- ======================================================================================================================= --sm24tat4xbQosStormControlTable sm24tat4xbQosStormControlTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosStormControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic QoS DSCP Translation settings for all switches." ::= { sm24tat4xbQosStormControl 1 } sm24tat4xbQosStormControlEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosStormControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Storm Control Entry." INDEX { sm24tat4xbQosStormControlFrameType } ::= { sm24tat4xbQosStormControlTable 1 } SM24TAT4XBQosStormControlEntry ::= SEQUENCE { sm24tat4xbQosStormControlFrameType INTEGER, sm24tat4xbQosStormControlEnabled AdminMode, sm24tat4xbQosStormControlRate Integer32, sm24tat4xbQosStormControlUnit Integer32 } sm24tat4xbQosStormControlFrameType OBJECT-TYPE SYNTAX INTEGER { unicast(1), multicast (2), broadcast (3)} MAX-ACCESS not-accessible STATUS current DESCRIPTION "The settings in a particular row apply to the frame type listed here. 1:Unicast, 2:Multicast, 3:Broadcast." ::= { sm24tat4xbQosStormControlEntry 1 } sm24tat4xbQosStormControlEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable the global storm policer for the given frame type." ::= { sm24tat4xbQosStormControlEntry 2 } sm24tat4xbQosStormControlRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the rate for the global storm policer." ::= { sm24tat4xbQosStormControlEntry 3 } sm24tat4xbQosStormControlUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the global storm policer rate as fps or kfps. 0: kbps 1: Mbps 2: fps 3: kfps" ::= { sm24tat4xbQosStormControlEntry 4 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosPortStormControl group -- ======================================================================================================================= --sm24tat4xbQosPortStormControlTable sm24tat4xbQosPortStormControlTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosPortStormControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configure the storm control settings. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortStormControl 1 } sm24tat4xbQosPortStormControlEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosPortStormControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Port Storm Control Entry." INDEX { ifIndex } ::= { sm24tat4xbQosPortStormControlTable 1 } SM24TAT4XBQosPortStormControlEntry ::= SEQUENCE { sm24tat4xbQosPortStormControlUnicastEnabled AdminMode, sm24tat4xbQosPortStormControlUnicastRate Integer32, sm24tat4xbQosPortStormControlUnicastUnit Integer32, sm24tat4xbQosPortStormControlBroadcastEnabled AdminMode, sm24tat4xbQosPortStormControlBroadcastRate Integer32, sm24tat4xbQosPortStormControlBroadcastUnit Integer32, sm24tat4xbQosPortStormControlUnknownEnabled AdminMode, sm24tat4xbQosPortStormControlUnknownRate Integer32, sm24tat4xbQosPortStormControlUnknownUnit Integer32 } sm24tat4xbQosPortStormControlUnicastEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the storm control is enabled on this switch port." ::= { sm24tat4xbQosPortStormControlEntry 2 } sm24tat4xbQosPortStormControlUnicastRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the rate for the storm control." ::= { sm24tat4xbQosPortStormControlEntry 3 } sm24tat4xbQosPortStormControlUnicastUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the storm control rate. 0: kbps 1: Mbps 2: fps 3: kfps" ::= { sm24tat4xbQosPortStormControlEntry 4 } sm24tat4xbQosPortStormControlBroadcastEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the storm control is enabled on this switch port." ::= { sm24tat4xbQosPortStormControlEntry 5 } sm24tat4xbQosPortStormControlBroadcastRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the rate for the storm control." ::= { sm24tat4xbQosPortStormControlEntry 6 } sm24tat4xbQosPortStormControlBroadcastUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the storm control rate. 0: kbps 1: Mbps 2: fps 3: kfps" ::= { sm24tat4xbQosPortStormControlEntry 7 } sm24tat4xbQosPortStormControlUnknownEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the storm control is enabled on this switch port." ::= { sm24tat4xbQosPortStormControlEntry 8 } sm24tat4xbQosPortStormControlUnknownRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the rate for the storm control." ::= { sm24tat4xbQosPortStormControlEntry 9 } sm24tat4xbQosPortStormControlUnknownUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the storm control rate. 0: kbps 1: Mbps 2: fps 3: kfps" ::= { sm24tat4xbQosPortStormControlEntry 10 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosWRED group -- ======================================================================================================================= --sm24tat4xbQosWREDTable sm24tat4xbQosWREDTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosWREDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic QoS DSCP Translation settings for all switches." ::= { sm24tat4xbQosWRED 1 } sm24tat4xbQosWREDEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosWREDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos WRED Entry." INDEX { sm24tat4xbQosWREDQueue } ::= { sm24tat4xbQosWREDTable 1 } SM24TAT4XBQosWREDEntry ::= SEQUENCE { sm24tat4xbQosWREDGroupIndex Integer32, sm24tat4xbQosWREDQueue Integer32, sm24tat4xbQosWREDDPL Integer32, sm24tat4xbQosWREDEnable AdminMode, sm24tat4xbQosWREDMinThreshold Integer32, sm24tat4xbQosWREDMaxThreshold Integer32, sm24tat4xbQosWREDMaxUnit INTEGER } sm24tat4xbQosWREDGroupIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The group number for which the configuration below applies." ::= { sm24tat4xbQosWREDEntry 1 } sm24tat4xbQosWREDQueue OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The queue number (QoS class) for which the configuration below applies." ::= { sm24tat4xbQosWREDEntry 2 } sm24tat4xbQosWREDDPL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The dpl number for which the configuration below applies." ::= { sm24tat4xbQosWREDEntry 3 } sm24tat4xbQosWREDEnable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether RED is enabled for this queue. " DEFVAL { disable } ::= { sm24tat4xbQosWREDEntry 4 } sm24tat4xbQosWREDMinThreshold OBJECT-TYPE SYNTAX Integer32(0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the lower RED fill level threshold. If the queue filling level is below this threshold, the drop probability is zero. range:0-100%, default: 0. " ::= { sm24tat4xbQosWREDEntry 5 } sm24tat4xbQosWREDMaxThreshold OBJECT-TYPE SYNTAX Integer32(0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the upper RED drop probability or fill level threshold for frames marked with Drop Precedence Level 1 (yellow frames). range:0-100%, default: 50. " ::= { sm24tat4xbQosWREDEntry 6 } sm24tat4xbQosWREDMaxUnit OBJECT-TYPE SYNTAX INTEGER {dropProbability (0), fillLevel (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selects the unit for Max. 0: Drop Probability, 1: Fill Level, default: Drop Probability. " DEFVAL { dropProbability } ::= { sm24tat4xbQosWREDEntry 7 } -- -- ======================================================================================================================= -- Start sm24tat4xbQosQCLStatus -- ======================================================================================================================= --sm24tat4xbQosQCLStatusTable sm24tat4xbQosQCLStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosQCLStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The basic QoS DSCP Translation settings for all switches." ::= { sm24tat4xbQosQCLStatus 1 } sm24tat4xbQosQCLStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosQCLStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos QCL Status Entry." INDEX { sm24tat4xbQosQCLStatusList } ::= { sm24tat4xbQosQCLStatusTable 1 } SM24TAT4XBQosQCLStatusEntry ::= SEQUENCE { sm24tat4xbQosQCLStatusList Integer32, sm24tat4xbQosQCLStatusUser DisplayString, sm24tat4xbQosQCLStatusQCEId DisplayString, sm24tat4xbQosQCLStatusFrameType DisplayString, sm24tat4xbQosQCLStatusPortlist DisplayString, sm24tat4xbQosQCLStatusActionQueuePriority DisplayString, sm24tat4xbQosQCLStatusActionDPL DisplayString, sm24tat4xbQosQCLStatusActionDSCP DisplayString, sm24tat4xbQosQCLStatusActionPCP DisplayString, sm24tat4xbQosQCLStatusActionDEL DisplayString, sm24tat4xbQosQCLStatusActionPolicy DisplayString, sm24tat4xbQosQCLStatusConflict DisplayString, -- sm24tat4xbQosQCLStatusSwitch Integer32, sm24tat4xbQosQCLStatusDMAC DisplayString, sm24tat4xbQosQCLStatusSMAC DisplayString, sm24tat4xbQosQCLStatusTag DisplayString, sm24tat4xbQosQCLStatusVID DisplayString, sm24tat4xbQosQCLStatusPCP DisplayString, sm24tat4xbQosQCLStatusDEI DisplayString } sm24tat4xbQosQCLStatusList OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "QCL table index." ::= { sm24tat4xbQosQCLStatusEntry 1} sm24tat4xbQosQCLStatusUser OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the QCL user." ::= { sm24tat4xbQosQCLStatusEntry 2 } sm24tat4xbQosQCLStatusQCEId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the index of QCE." ::= { sm24tat4xbQosQCLStatusEntry 3} sm24tat4xbQosQCLStatusFrameType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of frame to look for incomming frames. Any: The QCE will match all frame type. Ethernet: Only Ethernet frames (with Ether Type 0x600-0xFFFF) are allowed. LLC: Only (LLC) frames are allowed. SNAP: Only (SNAP) frames are allowed. IPv4: The QCE will match only IPV4 frames. IPv6: The QCE will match only IPV6 frames." ::= { sm24tat4xbQosQCLStatusEntry 4} sm24tat4xbQosQCLStatusPortlist OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the list of ports configured with the QCE." ::= { sm24tat4xbQosQCLStatusEntry 5} sm24tat4xbQosQCLStatusActionQueuePriority OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Classified QoS class; if a frame matches the QCE it will be put in the queue." ::= { sm24tat4xbQosQCLStatusEntry 6} sm24tat4xbQosQCLStatusActionDPL OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Drop Precedence Level; if a frame matches the QCE then DP level will set to value displayed under DPL column." ::= { sm24tat4xbQosQCLStatusEntry 7} sm24tat4xbQosQCLStatusActionDSCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If a frame matches the QCE then DSCP will be classified with the value displayed under DSCP column." ::= { sm24tat4xbQosQCLStatusEntry 8} sm24tat4xbQosQCLStatusActionPCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Classify PCP value. Only support SERVAL." ::= { sm24tat4xbQosQCLStatusEntry 9} sm24tat4xbQosQCLStatusActionDEL OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Classify DEI value. Only support SERVAL." ::= { sm24tat4xbQosQCLStatusEntry 10} sm24tat4xbQosQCLStatusActionPolicy OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Classify ACL Policy number. " ::= { sm24tat4xbQosQCLStatusEntry 11} sm24tat4xbQosQCLStatusConflict OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays Conflict status of QCL entries." ::= { sm24tat4xbQosQCLStatusEntry 12} -- sm24tat4xbQosQCLStatusSwitch OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Switch number for port members. -1:Any. -- Only support stacking switch." -- ::= { sm24tat4xbQosQCLStatusEntry 13} sm24tat4xbQosQCLStatusDMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Destination MAC address: Possible values are 'Unicast', 'Multicast', 'Broadcast' or 'Any'." ::= { sm24tat4xbQosQCLStatusEntry 14} sm24tat4xbQosQCLStatusSMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Source MAC address: xx-xx-xx-xx-xx-xx or 'Any'." ::= { sm24tat4xbQosQCLStatusEntry 15} sm24tat4xbQosQCLStatusTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value of Tag field can be 'Untagged', 'Tagged', 'C-Tagged', 'S-Tagged' or 'Any'." ::= { sm24tat4xbQosQCLStatusEntry 16} sm24tat4xbQosQCLStatusVID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Valid value of VLAN ID can be any value in the range 1-4095 or 'Any'" ::= { sm24tat4xbQosQCLStatusEntry 17} sm24tat4xbQosQCLStatusPCP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Valid value PCP are specific (0, 1, 2, 3, 4, 5, 6, 7) or range (0-1, 2-3, 4-5, 6-7, 0-3, 4-7) or 'Any'." ::= { sm24tat4xbQosQCLStatusEntry 18} sm24tat4xbQosQCLStatusDEI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Valid value of DEI can be '0', '1' or 'Any'." ::= { sm24tat4xbQosQCLStatusEntry 19} sm24tat4xbQosPortShaperTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosPortShaperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortShapers 1 } sm24tat4xbQosPortShaperEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosPortShaperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Port Shaper Entry." INDEX { ifIndex } ::= { sm24tat4xbQosPortShaperTable 1 } SM24TAT4XBQosPortShaperEntry ::= SEQUENCE { sm24tat4xbQosPortShaperQueue0Enable AdminMode, sm24tat4xbQosPortShaperQueue0Rate Integer32, sm24tat4xbQosPortShaperQueue0Unit Integer32, sm24tat4xbQosPortShaperQueue1Enable AdminMode, sm24tat4xbQosPortShaperQueue1Rate Integer32, sm24tat4xbQosPortShaperQueue1Unit Integer32, sm24tat4xbQosPortShaperQueue2Enable AdminMode, sm24tat4xbQosPortShaperQueue2Rate Integer32, sm24tat4xbQosPortShaperQueue2Unit Integer32, sm24tat4xbQosPortShaperQueue3Enable AdminMode, sm24tat4xbQosPortShaperQueue3Rate Integer32, sm24tat4xbQosPortShaperQueue3Unit Integer32, sm24tat4xbQosPortShaperQueue4Enable AdminMode, sm24tat4xbQosPortShaperQueue4Rate Integer32, sm24tat4xbQosPortShaperQueue4Unit Integer32, sm24tat4xbQosPortShaperQueue5Enable AdminMode, sm24tat4xbQosPortShaperQueue5Rate Integer32, sm24tat4xbQosPortShaperQueue5Unit Integer32, sm24tat4xbQosPortShaperQueue6Enable AdminMode, sm24tat4xbQosPortShaperQueue6Rate Integer32, sm24tat4xbQosPortShaperQueue6Unit Integer32, sm24tat4xbQosPortShaperQueue7Enable AdminMode, sm24tat4xbQosPortShaperQueue7Rate Integer32, sm24tat4xbQosPortShaperQueue7Unit Integer32, sm24tat4xbQosPortShaperEnable AdminMode, sm24tat4xbQosPortShaperRate Integer32, sm24tat4xbQosPortShaperRateType Integer32 } sm24tat4xbQosPortShaperQueue0Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 3 } sm24tat4xbQosPortShaperQueue0Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 4 } sm24tat4xbQosPortShaperQueue0Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 5 } sm24tat4xbQosPortShaperQueue1Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 6 } sm24tat4xbQosPortShaperQueue1Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 7 } sm24tat4xbQosPortShaperQueue1Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 8 } sm24tat4xbQosPortShaperQueue2Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 9 } sm24tat4xbQosPortShaperQueue2Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 10 } sm24tat4xbQosPortShaperQueue2Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 11 } sm24tat4xbQosPortShaperQueue3Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 12 } sm24tat4xbQosPortShaperQueue3Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 13 } sm24tat4xbQosPortShaperQueue3Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 14 } sm24tat4xbQosPortShaperQueue4Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 15 } sm24tat4xbQosPortShaperQueue4Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 16 } sm24tat4xbQosPortShaperQueue4Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 17 } sm24tat4xbQosPortShaperQueue5Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 18 } sm24tat4xbQosPortShaperQueue5Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 19 } sm24tat4xbQosPortShaperQueue5Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 20 } sm24tat4xbQosPortShaperQueue6Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 21 } sm24tat4xbQosPortShaperQueue6Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 22 } sm24tat4xbQosPortShaperQueue6Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 23 } sm24tat4xbQosPortShaperQueue7Enable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper is enabled on this switch port." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 24 } sm24tat4xbQosPortShaperQueue7Rate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the queue shaper rate. default: 500(Kbps)" ::= { sm24tat4xbQosPortShaperEntry 25 } sm24tat4xbQosPortShaperQueue7Unit OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the unit of measure for the queue shaper rate as kbps or Mbps. range: 0:kbs 1:Mbps default: 0(kbps)" ::= { sm24tat4xbQosPortShaperEntry 26 } sm24tat4xbQosPortShaperEnable OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the port shaper is enabled." DEFVAL { disable } ::= { sm24tat4xbQosPortShaperEntry 27 } sm24tat4xbQosPortShaperRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the rate for the port shaper. default: 500 kbps." ::= { sm24tat4xbQosPortShaperEntry 28 } sm24tat4xbQosPortShaperRateType OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "The rate type of the port shaper. 0:Line 1:Data" ::= { sm24tat4xbQosPortShaperEntry 29 } sm24tat4xbQosPortSchedulersTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBQosPortSchedulersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbQosPortSchedulers 1 } sm24tat4xbQosPortSchedulersEntry OBJECT-TYPE SYNTAX SM24TAT4XBQosPortSchedulersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Qos Port Shaper Entry." INDEX { ifIndex } ::= { sm24tat4xbQosPortSchedulersTable 1 } SM24TAT4XBQosPortSchedulersEntry ::= SEQUENCE { sm24tat4xbQosPortSchedulersMode Integer32, sm24tat4xbQosPortSchedulersQ0Weight Integer32, sm24tat4xbQosPortSchedulersQ1Weight Integer32, sm24tat4xbQosPortSchedulersQ2Weight Integer32, sm24tat4xbQosPortSchedulersQ3Weight Integer32, sm24tat4xbQosPortSchedulersQ4Weight Integer32, sm24tat4xbQosPortSchedulersQ5Weight Integer32, sm24tat4xbQosPortSchedulersQ6Weight Integer32, sm24tat4xbQosPortSchedulersQ7Weight Integer32 } sm24tat4xbQosPortSchedulersMode OBJECT-TYPE SYNTAX Integer32(0|8) MAX-ACCESS read-write STATUS current DESCRIPTION "0:Strict Priority 8:Weighted" ::= { sm24tat4xbQosPortSchedulersEntry 2 } sm24tat4xbQosPortSchedulersQ0Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 3 } sm24tat4xbQosPortSchedulersQ1Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 4 } sm24tat4xbQosPortSchedulersQ2Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 5 } sm24tat4xbQosPortSchedulersQ3Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 6 } sm24tat4xbQosPortSchedulersQ4Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 7 } sm24tat4xbQosPortSchedulersQ5Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 8 } sm24tat4xbQosPortSchedulersQ6Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 9 } sm24tat4xbQosPortSchedulersQ7Weight OBJECT-TYPE SYNTAX Integer32(1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the weight for this queue. This value is restricted to 1-100." ::= { sm24tat4xbQosPortSchedulersEntry 10 } -- ======================================================================================================================= --sm24tat4xbBroadcastStormProtection OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 11 } -- --sm24tat4xbBroadcastStormProtectionConfigurationTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SM24TAT4XBBroadcastStormProtectionConfigurationEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " Show Broadcast Storm Protection configurations. " -- ::= { sm24tat4xbBroadcastStormProtection 1 } -- --sm24tat4xbBroadcastStormProtectionConfigurationEntry OBJECT-TYPE -- SYNTAX SM24TAT4XBBroadcastStormProtectionConfigurationEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "" -- INDEX { sm24tat4xbBroadcastStormProtectionConfPort } -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationTable 1 } -- --SM24TAT4XBBroadcastStormProtectionConfigurationEntry ::= SEQUENCE { -- sm24tat4xbBroadcastStormProtectionConfPort Integer32, -- sm24tat4xbBroadcastStormProtectionConfMode INTEGER, -- sm24tat4xbBroadcastStormProtectionConfAction Integer32, -- sm24tat4xbBroadcastStormProtectionConfPPS Integer32, -- sm24tat4xbBroadcastStormProtectionConfTimer Integer32, -- sm24tat4xbBroadcastStormProtectionConfstatus DisplayString --} -- --sm24tat4xbBroadcastStormProtectionConfPort OBJECT-TYPE -- SYNTAX Integer32 (1..4095) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- " port, range : 1 - port number. " -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationEntry 1 } -- --sm24tat4xbBroadcastStormProtectionConfMode OBJECT-TYPE -- SYNTAX INTEGER { disable(0), enable(1)} -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- " Configure broadcast storm protection port mode. -- 0: disable, -- 1: enable -- default: disable. " -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationEntry 2 } -- --sm24tat4xbBroadcastStormProtectionConfAction OBJECT-TYPE -- SYNTAX Integer32 (0..2) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- " Configure broadcast storm protection port action. -- 0: Shutdown port, -- 1: Shutdown port and Log, -- 2: Log Only, -- default: Shutdown port. " -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationEntry 3 } -- --sm24tat4xbBroadcastStormProtectionConfPPS OBJECT-TYPE -- SYNTAX Integer32 (0..1000000) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- " Configure broadcast storm protection pps. -- default: 0. " -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationEntry 4 } -- --sm24tat4xbBroadcastStormProtectionConfTimer OBJECT-TYPE -- SYNTAX Integer32 (0..65535) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Configure broadcast storm protection timer(seconds) -- default: 300(seconds). " -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationEntry 5 } -- --sm24tat4xbBroadcastStormProtectionConfstatus OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " Show broadcast storm protection status. " -- ::= { sm24tat4xbBroadcastStormProtectionConfigurationEntry 6 } -- -- ======================================================================================================================= sm24tat4xbLoopProtection OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 12 } sm24tat4xbLoopProtectionConfig OBJECT IDENTIFIER ::= { sm24tat4xbLoopProtection 1 } sm24tat4xbLoopProtectionGlobalEnable OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure loop protection mode. 0: disable, 1: enable, default: disable. " ::= { sm24tat4xbLoopProtectionConfig 1 } sm24tat4xbLoopProtectionTranmisstionTime OBJECT-TYPE SYNTAX Integer32(1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure loop protection transmit interval. default: 5, range: 1-10. " ::= { sm24tat4xbLoopProtectionConfig 2 } sm24tat4xbLoopProtectionShutdownTime OBJECT-TYPE SYNTAX Integer32(0..604800) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure loop protection shutdown time. default: 180, range: 0-604800. " ::= { sm24tat4xbLoopProtectionConfig 3 } sm24tat4xbLoopProtectionConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLoopProtectionConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Show Loop Protection configurations. " ::= { sm24tat4xbLoopProtectionConfig 4 } sm24tat4xbLoopProtectionConfigurationEntry OBJECT-TYPE SYNTAX SM24TAT4XBLoopProtectionConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLoopProtectionConfPort } ::= { sm24tat4xbLoopProtectionConfigurationTable 1 } SM24TAT4XBLoopProtectionConfigurationEntry ::= SEQUENCE { sm24tat4xbLoopProtectionConfPort Integer32, sm24tat4xbLoopProtectionConfEnable Integer32, sm24tat4xbLoopProtectionConfAction Integer32, sm24tat4xbLoopProtectionConfTxmode Integer32 } sm24tat4xbLoopProtectionConfPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbLoopProtectionConfigurationEntry 1 } sm24tat4xbLoopProtectionConfEnable OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure loop protection port mode. 0: disable, 1: enable, default: enable. " ::= { sm24tat4xbLoopProtectionConfigurationEntry 2 } sm24tat4xbLoopProtectionConfAction OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-write STATUS current DESCRIPTION " Configure loop protection port action. 0: Shutdown port, 1: Shutdown port and Log, 2: Log Only, default: Shutdown port. " ::= { sm24tat4xbLoopProtectionConfigurationEntry 3 } sm24tat4xbLoopProtectionConfTxmode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure loop protection port transmit mode. 0: disable, 1: enable, default: enable. " ::= { sm24tat4xbLoopProtectionConfigurationEntry 4 } sm24tat4xbLoopProtectionStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLoopProtectionStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Show Loop Protection Status. " ::= { sm24tat4xbLoopProtection 2 } sm24tat4xbLoopProtectionStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBLoopProtectionStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLoopProtectionStatusPort } ::= { sm24tat4xbLoopProtectionStatusTable 1 } SM24TAT4XBLoopProtectionStatusEntry ::= SEQUENCE { sm24tat4xbLoopProtectionStatusPort Integer32, sm24tat4xbLoopProtectionStatusAction DisplayString, sm24tat4xbLoopProtectionStatusTransmit DisplayString, sm24tat4xbLoopProtectionStatusLoops Integer32, sm24tat4xbLoopProtectionStatusStatus DisplayString, sm24tat4xbLoopProtectionStatusLoop DisplayString, sm24tat4xbLoopProtectionStatusTimeLastLoop DisplayString } sm24tat4xbLoopProtectionStatusPort OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbLoopProtectionStatusEntry 1 } sm24tat4xbLoopProtectionStatusAction OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The currently configured port action. " ::= { sm24tat4xbLoopProtectionStatusEntry 2 } sm24tat4xbLoopProtectionStatusTransmit OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The currently configured port transmit mode. " ::= { sm24tat4xbLoopProtectionStatusEntry 3 } sm24tat4xbLoopProtectionStatusLoops OBJECT-TYPE SYNTAX Integer32 (0..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION " The number of loops detected on this port. " ::= { sm24tat4xbLoopProtectionStatusEntry 4 } sm24tat4xbLoopProtectionStatusStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The current loop protection status of the port. " ::= { sm24tat4xbLoopProtectionStatusEntry 5 } sm24tat4xbLoopProtectionStatusLoop OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Whether a loop is currently detected on the port. " ::= { sm24tat4xbLoopProtectionStatusEntry 6 } sm24tat4xbLoopProtectionStatusTimeLastLoop OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The time of the last loop event detected. " ::= { sm24tat4xbLoopProtectionStatusEntry 7 } -- ======================================================================================================================= sm24tat4xbPoe OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 13 } sm24tat4xbPoeStatus OBJECT IDENTIFIER ::= { sm24tat4xbPoe 1 } sm24tat4xbPoeStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Scheduling Table. " ::= { sm24tat4xbPoeStatus 1 } sm24tat4xbPoeStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeStatusLocalPort } ::= { sm24tat4xbPoeStatusTable 1 } SM24TAT4XBPoeStatusEntry ::= SEQUENCE { sm24tat4xbPoeStatusLocalPort Integer32, sm24tat4xbPoeStatusPDclass DisplayString, sm24tat4xbPoeStatusPowerRequested DisplayString, sm24tat4xbPoeStatusPowerAllocated DisplayString, sm24tat4xbPoeStatusPowerUsed DisplayString, sm24tat4xbPoeStatusCurrentUsed DisplayString, sm24tat4xbPoeStatusPriority DisplayString, sm24tat4xbPoeStatusPortStatus DisplayString } sm24tat4xbPoeStatusLocalPort OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Local port Index." ::= { sm24tat4xbPoeStatusEntry 1 } sm24tat4xbPoeStatusPDclass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates the QCL user. 0: Max. power 15.4 W, 1: Max. power 4.0 W, 2: Max. power 7.0 W, 3: Max. power 15.4 W, 4: Max. power 30.0 W. " ::= { sm24tat4xbPoeStatusEntry 2 } sm24tat4xbPoeStatusPowerRequested OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The Power Requested shows the requested amount of power the PD wants to be reserved. " ::= { sm24tat4xbPoeStatusEntry 3} sm24tat4xbPoeStatusPowerAllocated OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The Power Allocated shows the amount of power the switch has allocated for the PD. " ::= { sm24tat4xbPoeStatusEntry 4} sm24tat4xbPoeStatusPowerUsed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The Power Used shows how much power the PD currently is using. " ::= { sm24tat4xbPoeStatusEntry 5} sm24tat4xbPoeStatusCurrentUsed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The Power Used shows how much current the PD currently is using. " ::= { sm24tat4xbPoeStatusEntry 6} sm24tat4xbPoeStatusPriority OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The Priority shows the port's priority configured by the user. " ::= { sm24tat4xbPoeStatusEntry 7} sm24tat4xbPoeStatusPortStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The Port Status shows the port's status. " ::= { sm24tat4xbPoeStatusEntry 8} sm24tat4xbPoeStatusTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeStatusTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Scheduling Total Table. " ::= { sm24tat4xbPoeStatus 2 } sm24tat4xbPoeStatusTotalEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeStatusTotalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeStatusSwitchIndex } ::= { sm24tat4xbPoeStatusTotalTable 1 } SM24TAT4XBPoeStatusTotalEntry ::= SEQUENCE { sm24tat4xbPoeStatusSwitchIndex Integer32, sm24tat4xbPoeStatusTotalPowerRequested DisplayString, sm24tat4xbPoeStatusTotalPowerAllocated DisplayString, sm24tat4xbPoeStatusTotalPowerUsed DisplayString, sm24tat4xbPoeStatusTotalCurrentUsed DisplayString } sm24tat4xbPoeStatusSwitchIndex OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch Index." ::= { sm24tat4xbPoeStatusTotalEntry 1 } sm24tat4xbPoeStatusTotalPowerRequested OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Total Power Requested." ::= { sm24tat4xbPoeStatusTotalEntry 2} sm24tat4xbPoeStatusTotalPowerAllocated OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Total Power allocated." ::= { sm24tat4xbPoeStatusTotalEntry 3} sm24tat4xbPoeStatusTotalPowerUsed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Total Power Used." ::= { sm24tat4xbPoeStatusTotalEntry 4} sm24tat4xbPoeStatusTotalCurrentUsed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Total Current Used." ::= { sm24tat4xbPoeStatusTotalEntry 5} sm24tat4xbPoePowerDelay OBJECT IDENTIFIER ::= { sm24tat4xbPoe 2 } sm24tat4xbPoePowerDelayTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoePowerDelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Power Delay mode. " ::= { sm24tat4xbPoePowerDelay 1 } sm24tat4xbPoePowerDelayEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoePowerDelayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoePowerDelayPort } ::= { sm24tat4xbPoePowerDelayTable 1 } SM24TAT4XBPoePowerDelayEntry ::= SEQUENCE { sm24tat4xbPoePowerDelayPort Integer32, sm24tat4xbPoePowerDelayMode Integer32, sm24tat4xbPoePowerDelayTime Integer32 } sm24tat4xbPoePowerDelayPort OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbPoePowerDelayEntry 1 } sm24tat4xbPoePowerDelayMode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Turn on / off the power delay function, 0: disable, 1: enable, default: disable. " ::= { sm24tat4xbPoePowerDelayEntry 2 } sm24tat4xbPoePowerDelayTime OBJECT-TYPE SYNTAX Integer32(0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "set Delay Time, default: 0, range: 0-300 sec. " ::= { sm24tat4xbPoePowerDelayEntry 3 } sm24tat4xbPoeAutoPowerReset OBJECT IDENTIFIER ::= { sm24tat4xbPoe 3 } sm24tat4xbPoeAutoPowerResetPingCheck OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "connection between PoE port and power device. 0: disable, 1: enable, default: disable. " ::= { sm24tat4xbPoeAutoPowerReset 1 } sm24tat4xbPoeAutoPowerResetTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeAutoPowerResetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Auto Power Reset mode. " ::= { sm24tat4xbPoeAutoPowerReset 2 } sm24tat4xbPoeAutoPowerResetEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeAutoPowerResetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeAutoPowerResetPort } ::= { sm24tat4xbPoeAutoPowerResetTable 1 } SM24TAT4XBPoeAutoPowerResetEntry ::= SEQUENCE { sm24tat4xbPoeAutoPowerResetPort Integer32, sm24tat4xbPoeAutoPowerResetPingIPAddress DisplayString, sm24tat4xbPoeAutoPowerResetStartupTime Integer32, sm24tat4xbPoeAutoPowerResetIntervalTime Integer32, sm24tat4xbPoeAutoPowerResetRetryTime Integer32, sm24tat4xbPoeAutoPowerResetFailureLog DisplayString, sm24tat4xbPoeAutoPowerResetFailureAction INTEGER, sm24tat4xbPoeAutoPowerResetRebootTime Integer32, sm24tat4xbPoeAutoPowerResetMaxRebootTimes Integer32 } sm24tat4xbPoeAutoPowerResetPort OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbPoeAutoPowerResetEntry 1 } sm24tat4xbPoeAutoPowerResetPingIPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "IP Address the system should ping. default: 0.0.0.0 . " ::= { sm24tat4xbPoeAutoPowerResetEntry 2 } sm24tat4xbPoeAutoPowerResetStartupTime OBJECT-TYPE SYNTAX Integer32(30..600) MAX-ACCESS read-write STATUS current DESCRIPTION "When PD has been start up, the Switch will wait Start up time to do PoE Auto Checking. default: 60, range: 30-600 sec. " ::= { sm24tat4xbPoeAutoPowerResetEntry 3 } sm24tat4xbPoeAutoPowerResetIntervalTime OBJECT-TYPE SYNTAX Integer32(10..120) MAX-ACCESS read-write STATUS current DESCRIPTION "Device will send checking message to PD each interval time. default: 30, range: 10-120 sec. " ::= { sm24tat4xbPoeAutoPowerResetEntry 4 } sm24tat4xbPoeAutoPowerResetRetryTime OBJECT-TYPE SYNTAX Integer32(1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "It will retry to send detection again. default: 3, range: 1-5. " ::= { sm24tat4xbPoeAutoPowerResetEntry 5 } sm24tat4xbPoeAutoPowerResetFailureLog OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Failure loggings counter. " ::= { sm24tat4xbPoeAutoPowerResetEntry 6 } sm24tat4xbPoeAutoPowerResetFailureAction OBJECT-TYPE SYNTAX INTEGER { nothing(0), reboot(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "It will retry to send detection again, 0: Nothing, 1: Reboot Remote PD, default: Nothing. " ::= { sm24tat4xbPoeAutoPowerResetEntry 7 } sm24tat4xbPoeAutoPowerResetRebootTime OBJECT-TYPE SYNTAX Integer32(3..120) MAX-ACCESS read-write STATUS current DESCRIPTION "When PD has been rebooted, the PoE port restored power after the specified time. default: 15, range: 3-120 sec. " ::= { sm24tat4xbPoeAutoPowerResetEntry 8 } sm24tat4xbPoeAutoPowerResetMaxRebootTimes OBJECT-TYPE SYNTAX Integer32(0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "When Failure Action is Reboot Remote PD, it limits times of Reboot. default: 3, range: 0-10. 0 means without reboot limits." ::= { sm24tat4xbPoeAutoPowerResetEntry 10 } sm24tat4xbPoeScheduling OBJECT IDENTIFIER ::= { sm24tat4xbPoe 4 } sm24tat4xbPoeSchedulingProfileNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the PoE Profile Number that want to configure. Range:1-16" ::= { sm24tat4xbPoeScheduling 1 } sm24tat4xbPoeSchedulingPorofileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Profile Name. Maximum length:32." ::= { sm24tat4xbPoeScheduling 2 } sm24tat4xbPoeSchedulingTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeSchedulingTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Show Poe Scheduling Time Config. " ::= { sm24tat4xbPoeScheduling 3 } sm24tat4xbPoeSchedulingTimeEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeSchedulingTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeSchedulingTimeWeekIndex } ::= { sm24tat4xbPoeSchedulingTimeTable 1 } SM24TAT4XBPoeSchedulingTimeEntry ::= SEQUENCE { sm24tat4xbPoeSchedulingTimeWeekIndex Integer32, sm24tat4xbPoeSchedulingTimeStartTimeHourMinute DisplayString, sm24tat4xbPoeSchedulingTimeEndTimeHourMinute DisplayString } sm24tat4xbPoeSchedulingTimeWeekIndex OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Week Index. 1: Mon, 2:Tue, 3: Wed, 4: Thu, 5: Fri, 6: Sat, 7: Sun" ::= { sm24tat4xbPoeSchedulingTimeEntry 1 } sm24tat4xbPoeSchedulingTimeStartTimeHourMinute OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "PoE Scheduling Start Time. Format: HH:MM. Hour Range: 0-23. Minute Range:0,5,10,...,55." ::= { sm24tat4xbPoeSchedulingTimeEntry 2 } sm24tat4xbPoeSchedulingTimeEndTimeHourMinute OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "PoE Scheduling End Time. Format: HH:MM. Hour Range: 0-23. Minute Range:0,5,10,...,55." ::= { sm24tat4xbPoeSchedulingTimeEntry 3 } sm24tat4xbPoeConfiguration OBJECT IDENTIFIER ::= { sm24tat4xbPoe 5 } sm24tat4xbPoeConfigurationPowerManagementMode OBJECT-TYPE SYNTAX Integer32(0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "The power management mode for PoE port. 0: CLASS_RESERVED, 1: CLASS_CONSUMP, 2: ALLOCATED_RESERVED, 3: ALLOCATED_CONSUMP, 4: LLDPMED_RESERVED, 5: LLDPMED_CONSUMP, default: CLASS_RESERVED. " ::= { sm24tat4xbPoeConfiguration 1 } sm24tat4xbPoeConfigurationCapacitorDetection OBJECT-TYPE SYNTAX Integer32(0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "The capacitor detection mode. 0: Disable 1: Enable " ::= { sm24tat4xbPoeConfiguration 2 } sm24tat4xbPoeConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Configuration mode. " ::= { sm24tat4xbPoeConfiguration 4 } sm24tat4xbPoeConfigurationEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeConfigurationSwitch } ::= { sm24tat4xbPoeConfigurationTable 1 } SM24TAT4XBPoeConfigurationEntry ::= SEQUENCE { sm24tat4xbPoeConfigurationSwitch Integer32, sm24tat4xbPoeConfigurationPrimaryPowerSupply Integer32, sm24tat4xbPoeConfigurationAlwaysOnPoE Integer32 } sm24tat4xbPoeConfigurationSwitch OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION " switch index, range : 1 - 16. " ::= { sm24tat4xbPoeConfigurationEntry 1 } sm24tat4xbPoeConfigurationPrimaryPowerSupply OBJECT-TYPE SYNTAX Integer32(0..2000) MAX-ACCESS read-only STATUS current DESCRIPTION "It must be defined what amount of power the primary and backup power sources can deliver. " ::= { sm24tat4xbPoeConfigurationEntry 3 } sm24tat4xbPoeConfigurationAlwaysOnPoE OBJECT-TYPE SYNTAX Integer32(0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure always-on-poe" ::= { sm24tat4xbPoeConfigurationEntry 4 } sm24tat4xbPoeConfigurationPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeConfigurationPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Port Configuration mode. " ::= { sm24tat4xbPoeConfiguration 5 } sm24tat4xbPoeConfigurationPortEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeConfigurationPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeConfigurationPort } ::= { sm24tat4xbPoeConfigurationPortTable 1 } SM24TAT4XBPoeConfigurationPortEntry ::= SEQUENCE { sm24tat4xbPoeConfigurationPort Integer32, sm24tat4xbPoeConfigurationPortPoEMode INTEGER, sm24tat4xbPoeConfigurationPortPriority INTEGER, sm24tat4xbPoeConfigurationPortMaximumPower DisplayString, sm24tat4xbPoeConfigurationPortDetection Integer32, -- sm24tat4xbPoeConfigurationPortPoEScheduleByProfileID Integer32, sm24tat4xbPoeConfigurationPortPoEScheduleByProfileName DisplayString, sm24tat4xbPoeConfigurationPortDelayMode Integer32, sm24tat4xbPoeConfigurationPortDelayTime Integer32 } sm24tat4xbPoeConfigurationPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION " port, range : 1 - port number. " ::= { sm24tat4xbPoeConfigurationPortEntry 1 } sm24tat4xbPoeConfigurationPortPoEMode OBJECT-TYPE SYNTAX INTEGER { disable(0), poe(1) , poeforce(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The PoE Mode represents the PoE operating mode for the port. 0: Disable, 1: Enable, 3: Force, default: Enable. " ::= { sm24tat4xbPoeConfigurationPortEntry 2 } sm24tat4xbPoeConfigurationPortPriority OBJECT-TYPE SYNTAX INTEGER { low(0), high(1), critical(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Priority represents the ports priority. There are three levels of power priority named Low, High and Critical. 0: Low, 1: High, 2: Critical, default: Low. " ::= { sm24tat4xbPoeConfigurationPortEntry 3 } sm24tat4xbPoeConfigurationPortMaximumPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The Maximum Power value contains a numerical value that indicates the maximum power in watts that can be delivered to a remote device. max: 30[W]. " ::= { sm24tat4xbPoeConfigurationPortEntry 4 } sm24tat4xbPoeConfigurationPortDetection OBJECT-TYPE SYNTAX Integer32(1..5) MAX-ACCESS read-write STATUS current DESCRIPTION "The Detection represents the PoE capacitor detection for the port. -1:Not support. 1:Legacy : Legacy capacitive detection only. 2:4-point : IEEE 802.3af 4-point detection only. 3:4-point-legacy : IEEE 802.3af 4-point detection followed by Legacy detection. 4:2-point : IEEE 802.3af 2-point detection only. 5:2-point-legacy : IEEE 802.3af 2-point detection followed by Legacy detection. " ::= { sm24tat4xbPoeConfigurationPortEntry 5 } -- sm24tat4xbPoeConfigurationPortPoEScheduleByProfileID OBJECT-TYPE -- SYNTAX Integer32(0..16) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Specify a valid PoE schedule profile by profile id. 0:disable,1-16:1-16 profile." -- ::= { sm24tat4xbPoeConfigurationPortEntry 6 } sm24tat4xbPoeConfigurationPortPoEScheduleByProfileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Specify a valid PoE schedule profile by profile name. disabled: disable profile schedule." ::= { sm24tat4xbPoeConfigurationPortEntry 7 } sm24tat4xbPoeConfigurationPortDelayMode OBJECT-TYPE SYNTAX Integer32(0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "Turn on off the power delay function. 0: Disable 1: Enable" ::= { sm24tat4xbPoeConfigurationPortEntry 8 } sm24tat4xbPoeConfigurationPortDelayTime OBJECT-TYPE SYNTAX Integer32(0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "When rebooting, the PoE port will start to provide power to the PD when it out of delay time. Range:0-300" ::= { sm24tat4xbPoeConfigurationPortEntry 9 } sm24tat4xbPoeChipsetRebootSchedule OBJECT IDENTIFIER ::= { sm24tat4xbPoe 6 } sm24tat4xbPoeChipsetRebootMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "PoE Chipset Reboot Mode 0:disable 1:enable" ::= { sm24tat4xbPoeChipsetRebootSchedule 1 } sm24tat4xbPoeChipsetRebootTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPoeChipsetRebootTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure PoE Chipset Reboot Time." ::= { sm24tat4xbPoeChipsetRebootSchedule 2 } sm24tat4xbPoeChipsetRebootTimeEntry OBJECT-TYPE SYNTAX SM24TAT4XBPoeChipsetRebootTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPoeChipsetRebootWeekIndex } ::= { sm24tat4xbPoeChipsetRebootTimeTable 1 } SM24TAT4XBPoeChipsetRebootTimeEntry ::= SEQUENCE { sm24tat4xbPoeChipsetRebootWeekIndex Integer32, sm24tat4xbPoeChipsetRebootTimeHour Integer32, sm24tat4xbPoeChipsetRebootTimeMinute Integer32 } sm24tat4xbPoeChipsetRebootWeekIndex OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "PoE chipset reboot week index. 1: Mon, 2:Tue, 3: Wed, 4: Thu, 5: Fri, 6: Sat, 7: Sun" ::= { sm24tat4xbPoeChipsetRebootTimeEntry 1 } sm24tat4xbPoeChipsetRebootTimeHour OBJECT-TYPE SYNTAX Integer32 (-1..23) MAX-ACCESS read-write STATUS current DESCRIPTION "PoE Chipset Reboot Time (Hour). Range: 0-23. -1:disable" ::= { sm24tat4xbPoeChipsetRebootTimeEntry 2 } sm24tat4xbPoeChipsetRebootTimeMinute OBJECT-TYPE SYNTAX Integer32 (-1..55) MAX-ACCESS read-write STATUS current DESCRIPTION "PoE Chipset Reboot Time (Minute). Range:0,5,10,...,55. -1:disable" ::= { sm24tat4xbPoeChipsetRebootTimeEntry 3 } -- ======================================================================================================================= -- RowStatus Info: createAndWait, notReady, notInService not supported. -- ======================================================================================================================= -- Textual Conventions for the sm24tat4xb AAA Mib -- ======================================================================================================================= -- sm24tat4xbAAAMIB OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 15 } sm24tat4xbAAA OBJECT IDENTIFIER ::= { sm24tat4xbAAAMIB 1 } sm24tat4xbRADIUS OBJECT IDENTIFIER ::= { sm24tat4xbAAA 1 } sm24tat4xbRADIUSGlobalConfig OBJECT IDENTIFIER ::= { sm24tat4xbRADIUS 1 } sm24tat4xbTACACS OBJECT IDENTIFIER ::= { sm24tat4xbAAA 2 } -- -- ======================================================================================================================= -- Start sm24tat4xbRADIUS group -- ======================================================================================================================= --sm24tat4xbRADIUSGlobalConfig sm24tat4xbRADIUSGlobalConfigTimeout OBJECT-TYPE SYNTAX Integer32(1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout is the number of seconds, to wait for a reply from a RADIUS server before retransmitting the request. range: 1-1000." ::= { sm24tat4xbRADIUSGlobalConfig 1 } sm24tat4xbRADIUSGlobalConfigRetransmit OBJECT-TYPE SYNTAX Integer32(1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Retransmit is the number of times,a RADIUS request is retransmitted to a server that is not responding.If the server has not responded after the last retransmit it is considered to be dead. range: 1-1000." ::= { sm24tat4xbRADIUSGlobalConfig 2 } sm24tat4xbRADIUSGlobalConfigDeadtime OBJECT-TYPE SYNTAX Integer32(0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "This will stop the switch from continually trying to contact a server that it has already determined as dead. range: 0-1440." ::= { sm24tat4xbRADIUSGlobalConfig 3 } sm24tat4xbRADIUSGlobalConfigKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The secret key shared between the RADIUS server and the switch." ::= { sm24tat4xbRADIUSGlobalConfig 4 } sm24tat4xbRADIUSGlobalConfigNASIPv4 OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv4 address to be used as attribute 4 in RADIUS Access-Request packets." ::= { sm24tat4xbRADIUSGlobalConfig 5 } sm24tat4xbRADIUSGlobalConfigNASIPv6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The IPv6 address to be used as attribute 95 in RADIUS Access-Request packets. " ::= { sm24tat4xbRADIUSGlobalConfig 6 } sm24tat4xbRADIUSGlobalConfigNASIdentifier OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The identifier to be used as attribute 32 in RADIUS Access-Request packets. " ::= { sm24tat4xbRADIUSGlobalConfig 7 } --sm24tat4xbRADIUSServerConfigTable sm24tat4xbRADIUSServerConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBRADIUSServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RADIUS Server Configuration Table." ::= { sm24tat4xbRADIUS 2 } sm24tat4xbRADIUSServerConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBRADIUSServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RADIUS Server Configuration Entry." INDEX { sm24tat4xbRADIUSServerConfServerNo } ::= { sm24tat4xbRADIUSServerConfigTable 1 } SM24TAT4XBRADIUSServerConfigEntry ::= SEQUENCE { sm24tat4xbRADIUSServerConfServerNo Integer32, sm24tat4xbRADIUSServerConfHostname DisplayString, sm24tat4xbRADIUSServerConfAuthPort Integer32, sm24tat4xbRADIUSServerConfAcctPort Integer32, sm24tat4xbRADIUSServerConfTimeout Integer32, sm24tat4xbRADIUSServerConfRetransmit Integer32, sm24tat4xbRADIUSServerConfKey DisplayString, sm24tat4xbRADIUSServerConfRowStatus RowStatus } sm24tat4xbRADIUSServerConfServerNo OBJECT-TYPE SYNTAX Integer32(1..5) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RADIUS server number. max: 5." ::= { sm24tat4xbRADIUSServerConfigEntry 1 } sm24tat4xbRADIUSServerConfHostname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The IP address or hostname of the RADIUS server. " ::= { sm24tat4xbRADIUSServerConfigEntry 2 } sm24tat4xbRADIUSServerConfAuthPort OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The UDP port to use on the RADIUS server for authentication. range: 0-65535. " ::= { sm24tat4xbRADIUSServerConfigEntry 3 } sm24tat4xbRADIUSServerConfAcctPort OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The UDP port to use on the RADIUS server for accounting. range: 0-65535. " ::= { sm24tat4xbRADIUSServerConfigEntry 4 } sm24tat4xbRADIUSServerConfTimeout OBJECT-TYPE SYNTAX Integer32(1..1000) MAX-ACCESS read-create STATUS current DESCRIPTION "This optional setting overrides the global timeout value. Leaving it blank will use the global timeout value. range: 1-1000. " ::= { sm24tat4xbRADIUSServerConfigEntry 5 } sm24tat4xbRADIUSServerConfRetransmit OBJECT-TYPE SYNTAX Integer32(1..1000) MAX-ACCESS read-create STATUS current DESCRIPTION "This optional setting overrides the global retransmit value. Leaving it blank will use the global retransmit value. range: 1-1000. " ::= { sm24tat4xbRADIUSServerConfigEntry 6 } sm24tat4xbRADIUSServerConfKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This optional setting overrides the global key. Leaving it blank will use the global key." ::= { sm24tat4xbRADIUSServerConfigEntry 7 } sm24tat4xbRADIUSServerConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbRADIUSServerConfigEntry 8 } --sm24tat4xbRADIUSDetailTable sm24tat4xbRADIUSDetailTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBRADIUSDetailEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RADIUS Detail Table." ::= { sm24tat4xbRADIUS 3 } sm24tat4xbRADIUSDetailEntry OBJECT-TYPE SYNTAX SM24TAT4XBRADIUSDetailEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The RADIUS Detail Entry." INDEX { sm24tat4xbRADIUSServerConfServerNo } ::= { sm24tat4xbRADIUSDetailTable 1 } SM24TAT4XBRADIUSDetailEntry ::= SEQUENCE { sm24tat4xbRADIUSAuthIPAddress DisplayString, sm24tat4xbRADIUSAuthStatus DisplayString, sm24tat4xbRADIUSAuthRoundTripTime Integer32, sm24tat4xbRADIUSAuthRxAccessAccept Counter32, sm24tat4xbRADIUSAuthRxAccessReject Counter32, sm24tat4xbRADIUSAuthRxAccessChallenge Counter32, sm24tat4xbRADIUSAuthRxAccessResponse Counter32, sm24tat4xbRADIUSAuthRxBadAuth Counter32, sm24tat4xbRADIUSAuthRxUnknownType Counter32, sm24tat4xbRADIUSAuthRxPacketsDropped Counter32, sm24tat4xbRADIUSAuthTxAccessRequest Counter32, sm24tat4xbRADIUSAuthTxAccessRetransmission Counter32, sm24tat4xbRADIUSAuthTxPendingRequest Counter32, sm24tat4xbRADIUSAuthTxTimeout Counter32, sm24tat4xbRADIUSAccountIPAddress IpAddress, sm24tat4xbRADIUSAccountStatus DisplayString, sm24tat4xbRADIUSAccountRoundTripTime Integer32, sm24tat4xbRADIUSAccountRxResponses Counter32, sm24tat4xbRADIUSAccountRxMalformedResponse Counter32, sm24tat4xbRADIUSAccountRxBadAuth Counter32, sm24tat4xbRADIUSAccountRxUnknownType Counter32, sm24tat4xbRADIUSAccountRxPacketsDrop Counter32, sm24tat4xbRADIUSAccountTxRequest Counter32, sm24tat4xbRADIUSAccountTxRetransmission Counter32, sm24tat4xbRADIUSAccountTxPendingRequest Counter32, sm24tat4xbRADIUSAccountTxTimeout Counter32, sm24tat4xbRADIUSDetailClearCmd ActivateCmd } sm24tat4xbRADIUSAuthIPAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IP address and UDP port for the authentication server in question." ::= { sm24tat4xbRADIUSDetailEntry 2 } sm24tat4xbRADIUSAuthStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the state of the server." ::= { sm24tat4xbRADIUSDetailEntry 3 } sm24tat4xbRADIUSAuthRoundTripTime OBJECT-TYPE SYNTAX Integer32(0..100000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval (measured in milliseconds) between the most recent Access-Reply/Access-Challenge and the Access-Request that matched it from the RADIUS authentication server." ::= { sm24tat4xbRADIUSDetailEntry 4 } sm24tat4xbRADIUSAuthRxAccessAccept OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Accept packets (valid or invalid) received from the server." ::= { sm24tat4xbRADIUSDetailEntry 5 } sm24tat4xbRADIUSAuthRxAccessReject OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Reject packets (valid or invalid) received from the server." ::= { sm24tat4xbRADIUSDetailEntry 6 } sm24tat4xbRADIUSAuthRxAccessChallenge OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Challenge packets (valid or invalid) received from the server." ::= { sm24tat4xbRADIUSDetailEntry 7 } sm24tat4xbRADIUSAuthRxAccessResponse OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of malformed RADIUS Access-Response packets received from the server." ::= { sm24tat4xbRADIUSDetailEntry 8 } sm24tat4xbRADIUSAuthRxBadAuth OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Response packets containing invalid authenticators or Message Authenticator attributes received from the server." ::= { sm24tat4xbRADIUSDetailEntry 9 } sm24tat4xbRADIUSAuthRxUnknownType OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets that were received with unknown types from the server on the authentication port and dropped." ::= { sm24tat4xbRADIUSDetailEntry 10 } sm24tat4xbRADIUSAuthRxPacketsDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets that were received from the server on the authentication port and dropped for some other reason." ::= { sm24tat4xbRADIUSDetailEntry 11 } sm24tat4xbRADIUSAuthTxAccessRequest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Request packets sent to the server. This does not include retransmissions." ::= { sm24tat4xbRADIUSDetailEntry 12 } sm24tat4xbRADIUSAuthTxAccessRetransmission OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Request packets retransmitted to the RADIUS authentication server." ::= { sm24tat4xbRADIUSDetailEntry 13 } sm24tat4xbRADIUSAuthTxPendingRequest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS Access-Request packets destined for the server that have not yet timed out or received a response. " ::= { sm24tat4xbRADIUSDetailEntry 14 } sm24tat4xbRADIUSAuthTxTimeout OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of authentication timeouts to the server. After a timeout, the client may retry to the same server, send to a different server, or give up." ::= { sm24tat4xbRADIUSDetailEntry 15 } sm24tat4xbRADIUSAccountIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address and UDP port for the authentication server in question." ::= { sm24tat4xbRADIUSDetailEntry 16 } sm24tat4xbRADIUSAccountStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the state of the server. " ::= { sm24tat4xbRADIUSDetailEntry 17 } sm24tat4xbRADIUSAccountRoundTripTime OBJECT-TYPE SYNTAX Integer32(0..100000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval (measured in milliseconds) between the most recent Access-Reply/Access-Challenge and the Access-Request that matched it from the RADIUS authentication server." ::= { sm24tat4xbRADIUSDetailEntry 18 } sm24tat4xbRADIUSAccountRxResponses OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets (valid or invalid) received from the server." ::= { sm24tat4xbRADIUSDetailEntry 19 } sm24tat4xbRADIUSAccountRxMalformedResponse OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of malformed RADIUS packets received from the server. " ::= { sm24tat4xbRADIUSDetailEntry 20 } sm24tat4xbRADIUSAccountRxBadAuth OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets containing invalid authenticators received from the server." ::= { sm24tat4xbRADIUSDetailEntry 21 } sm24tat4xbRADIUSAccountRxUnknownType OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets of unknown types that were received from the server on the accounting port. " ::= { sm24tat4xbRADIUSDetailEntry 22 } sm24tat4xbRADIUSAccountRxPacketsDrop OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets that were received from the server on the accounting port and dropped for some other reason." ::= { sm24tat4xbRADIUSDetailEntry 23 } sm24tat4xbRADIUSAccountTxRequest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets sent to the server. This does not include retransmissions." ::= { sm24tat4xbRADIUSDetailEntry 24 } sm24tat4xbRADIUSAccountTxRetransmission OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets retransmitted to the RADIUS accounting server." ::= { sm24tat4xbRADIUSDetailEntry 25 } sm24tat4xbRADIUSAccountTxPendingRequest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of RADIUS packets destined for the server that have not yet timed out or received a response." ::= { sm24tat4xbRADIUSDetailEntry 26 } sm24tat4xbRADIUSAccountTxTimeout OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of accounting timeouts to the server. After a timeout, the client may retry to the same server, send to a different server, or give up." ::= { sm24tat4xbRADIUSDetailEntry 27 } sm24tat4xbRADIUSDetailClearCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-only STATUS current DESCRIPTION "Clears the counters for the selected server." ::= { sm24tat4xbRADIUSDetailEntry 28 } -- -- ======================================================================================================================= -- Start sm24tat4xbTACACS group -- ======================================================================================================================= --sm24tat4xbTACACSGlobalConfig sm24tat4xbTACACSGlobalConfigTimeout OBJECT-TYPE SYNTAX Integer32(1..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Timeout is the number of seconds,to wait for a reply from a TACACS+ server before it is considered to be dead. range: 1-1000 seconds, default: 5 seconds." ::= { sm24tat4xbTACACS 1 } sm24tat4xbTACACSGlobalConfigDeadtime OBJECT-TYPE SYNTAX Integer32(0..1440) MAX-ACCESS read-write STATUS current DESCRIPTION "The period during which the switch will not send new requests to a server that has failed to respond to a previous request. This will stop the switch from continually trying to contact a server that it has already determined as dead. range: 0-1440 minutes, default: 0 minutes." ::= { sm24tat4xbTACACS 2 } sm24tat4xbTACACSGlobalConfigKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The secret key shared between the TACACS+ server and the switch." ::= { sm24tat4xbTACACS 3 } --sm24tat4xbTACACSServerConfigTable sm24tat4xbTACACSServerConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBTACACSServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TACACS Server configuration Table." ::= { sm24tat4xbTACACS 4 } sm24tat4xbTACACSServerConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBTACACSServerConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TACACS Server configuration Entry." INDEX { sm24tat4xbTACACSServerConfigServerNo } ::= { sm24tat4xbTACACSServerConfigTable 1 } SM24TAT4XBTACACSServerConfigEntry ::= SEQUENCE { sm24tat4xbTACACSServerConfigServerNo Integer32, sm24tat4xbTACACSServerConfigHostname DisplayString, sm24tat4xbTACACSServerConfigPort Integer32, sm24tat4xbTACACSServerConfigTimeout Integer32, sm24tat4xbTACACSServerConfigKey DisplayString, sm24tat4xbTACACSServerConfigRowStatus RowStatus } sm24tat4xbTACACSServerConfigServerNo OBJECT-TYPE SYNTAX Integer32(1..5) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TACACS server number. max: 5." ::= { sm24tat4xbTACACSServerConfigEntry 1 } sm24tat4xbTACACSServerConfigHostname OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The IP address or hostname of the TACACS+ server." ::= { sm24tat4xbTACACSServerConfigEntry 2 } sm24tat4xbTACACSServerConfigPort OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The TCP port to use on the TACACS+ server for authentication." ::= { sm24tat4xbTACACSServerConfigEntry 3 } sm24tat4xbTACACSServerConfigTimeout OBJECT-TYPE SYNTAX Integer32(1..1000) MAX-ACCESS read-create STATUS current DESCRIPTION "This optional setting overrides the global timeout value. Leaving it blank will use the global timeout value. range: 1-1000." ::= { sm24tat4xbTACACSServerConfigEntry 4 } sm24tat4xbTACACSServerConfigKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This optional setting overrides the global key. Leaving it blank will use the global key. " ::= { sm24tat4xbTACACSServerConfigEntry 5 } sm24tat4xbTACACSServerConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbTACACSServerConfigEntry 6 } -- ======================================================================================================================= -- -- ======================================================================================================================= -- Textual Conventions for the sm24tat4xb Nas Mib -- ======================================================================================================================= -- sm24tat4xbNasMIB OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 16 } sm24tat4xbNAS OBJECT IDENTIFIER ::= { sm24tat4xbNasMIB 1 } sm24tat4xbNASConf OBJECT IDENTIFIER ::= { sm24tat4xbNAS 1 } sm24tat4xbNASStatus OBJECT IDENTIFIER ::= { sm24tat4xbNAS 2 } -- -- ======================================================================================================================= -- Start sm24tat4xbNAS group -- ======================================================================================================================= --sm24tat4xbNASConf sm24tat4xbNASConfMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if NAS is globally enabled or disabled on the switch." DEFVAL { disable } ::= { sm24tat4xbNASConf 1 } sm24tat4xbNASConfReauthenticationEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, successfully authenticated supplicants/clients are reauthenticated after the interval specified by the Reauthentication Period." DEFVAL { disable } ::= { sm24tat4xbNASConf 2 } sm24tat4xbNASConfReauthenticationPeriod OBJECT-TYPE SYNTAX Integer32(1..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the period, in seconds, after which a connected client must be reauthenticated. default: 3600 sec, range: 1-3600 sec." ::= { sm24tat4xbNASConf 3 } sm24tat4xbNASConfEAPOLTimeout OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the time for retransmission of Request Identity EAPOL frames. default: 30 sec, range: 1-65535 sec." ::= { sm24tat4xbNASConf 4 } sm24tat4xbNASConfAgingPeriod OBJECT-TYPE SYNTAX Integer32(0|10..1000000) MAX-ACCESS read-write STATUS current DESCRIPTION "When the NAS module uses the Port Security module to secure MAC addresses, the Port Security module needs to check for activity on the MAC address in question at regular intervals and free resources if no activity is seen within a given period of time. default: 300 sec, 0: no support. range: 0,10-1000000 sec." ::= { sm24tat4xbNASConf 5 } sm24tat4xbNASConfHoldTime OBJECT-TYPE SYNTAX Integer32(0|10..1000000) MAX-ACCESS read-write STATUS current DESCRIPTION "If a client is denied access - either because the RADIUS server denies the client access or because the RADIUS server request times out - the client is put on hold in the Unauthorized state. default: 10 sec, 0: no support. range: 0,10-1000000 sec." ::= { sm24tat4xbNASConf 6 } sm24tat4xbNASConfRADIUSQoSEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "RADIUS-assigned QoS provides a means to centrally control the traffic class to which traffic coming from a successfully authenticated supplicant is assigned on the switch." DEFVAL { disable } ::= { sm24tat4xbNASConf 7 } sm24tat4xbNASConfRADIUSVLANEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "RADIUS-assigned VLAN provides a means to centrally control the VLAN on which a successfully authenticated supplicant is placed on the switch." DEFVAL { disable } ::= { sm24tat4xbNASConf 8 } sm24tat4xbNASConfGuestVLANEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "A Guest VLAN is a special VLAN - typically with limited network access - on which 802.1X-unaware clients are placed after a network administrator-defined timeout." DEFVAL { disable } ::= { sm24tat4xbNASConf 9 } sm24tat4xbNASConfGuestVLANID OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the value that a port's Port VLAN ID is set to if a port is moved into the Guest VLAN. default: 1, range: 1-4095." ::= { sm24tat4xbNASConf 10 } sm24tat4xbNASConfMaxReauthCount OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of times the switch transmits an EAPOL Request Identity frame without response before considering entering the Guest VLAN is adjusted with this setting. default: 2, range: 1-255." ::= { sm24tat4xbNASConf 11 } sm24tat4xbNASConfAllowGuestVLAN OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "The switch remembers if an EAPOL frame has been received on the port for the life-time of the port." DEFVAL { disable } ::= { sm24tat4xbNASConf 12 } --sm24tat4xbNASPortConfTable sm24tat4xbNASPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBNASPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NAS Port Configuration Table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbNASConf 13 } sm24tat4xbNASPortConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBNASPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NAS Port Configuration Entry." INDEX { ifIndex } ::= { sm24tat4xbNASPortConfTable 1 } SM24TAT4XBNASPortConfEntry ::= SEQUENCE { sm24tat4xbNASPortConfAdminState Integer32, sm24tat4xbNASPortConfRADIUSQoSEnabled AdminMode, sm24tat4xbNASPortConfRADIUSVLANEnabled AdminMode, sm24tat4xbNASPortConfGuestVLANEnabled AdminMode, sm24tat4xbNASPortConfPortState DisplayString, sm24tat4xbNASPortConfReauthenticateCmd INTEGER, sm24tat4xbNASPortConfReinitializeCmd INTEGER } sm24tat4xbNASPortConfAdminState OBJECT-TYPE SYNTAX Integer32(0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This selection controls the port's authentication mode. 0: Force Authorized, 1: Force Unauthorized, 2: Port-based 802.1X, 3: Single 802.1X, 4: Multi 802.1X, 5: MAC-based Auth, range: 0-5." ::= { sm24tat4xbNASPortConfEntry 2 } sm24tat4xbNASPortConfRADIUSQoSEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "When RADIUS-Assigned QoS is both globally enabled and enabled on a given port, the switch reacts to QoS Class information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated." ::= { sm24tat4xbNASPortConfEntry 3 } sm24tat4xbNASPortConfRADIUSVLANEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "When RADIUS-Assigned VLAN is both globally enabled and enabled for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated." ::= { sm24tat4xbNASPortConfEntry 4 } sm24tat4xbNASPortConfGuestVLANEnabled OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "When Guest VLAN is both globally enabled and enabled for a given port, the switch considers moving the port into the Guest VLAN according to the rules." ::= { sm24tat4xbNASPortConfEntry 5 } sm24tat4xbNASPortConfPortState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the port." ::= { sm24tat4xbNASPortConfEntry 6 } sm24tat4xbNASPortConfReauthenticateCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Schedules a reauthentication whenever the quiet-period of the port runs out (EAPOL-based authentication). For MAC-based authentication, reauthentication will be attempted immediately.The button only has effect for successfully authenticated clients on the port and will not cause the clients to get temporarily unauthorized." DEFVAL { noAction } ::= { sm24tat4xbNASPortConfEntry 7 } sm24tat4xbNASPortConfReinitializeCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Forces a reinitialization of the clients on the port and thereby a reauthentication immediately. The clients will transfer to the unauthorized state while the reauthentication is in progress." DEFVAL { noAction } ::= { sm24tat4xbNASPortConfEntry 8 } --sm24tat4xbNASSwitchStatusTable sm24tat4xbNASSwitchStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBNASSwitchStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NAS Switch Status Table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbNASStatus 1 } sm24tat4xbNASSwitchStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBNASSwitchStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NAS Switch Status Entry." INDEX { ifIndex } ::= { sm24tat4xbNASSwitchStatusTable 1 } SM24TAT4XBNASSwitchStatusEntry ::= SEQUENCE { sm24tat4xbNASSwitchStatusAdminState DisplayString, sm24tat4xbNASSwitchStatusPortState DisplayString, sm24tat4xbNASSwitchStatusLastSource DisplayString, sm24tat4xbNASSwitchStatusLastID DisplayString, sm24tat4xbNASSwitchStatusQoSClass DisplayString, sm24tat4xbNASSwitchStatusPortVLANID DisplayString } sm24tat4xbNASSwitchStatusAdminState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The port's current administrative state." ::= { sm24tat4xbNASSwitchStatusEntry 2 } sm24tat4xbNASSwitchStatusPortState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the port." ::= { sm24tat4xbNASSwitchStatusEntry 3 } sm24tat4xbNASSwitchStatusLastSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The source MAC address carried in the most recently received EAPOL frame for EAPOL-based authentication, and the most recently received frame from a new client for MAC-based authentication." ::= { sm24tat4xbNASSwitchStatusEntry 4 } sm24tat4xbNASSwitchStatusLastID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The user name (supplicant identity) carried in the most recently received Response Identity EAPOL frame for EAPOL-based authentication, and the source MAC address from the most recently received frame from a new client for MAC-based authentication." ::= { sm24tat4xbNASSwitchStatusEntry 5 } sm24tat4xbNASSwitchStatusQoSClass OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "QoS Class assigned to the port by the RADIUS server if enabled." ::= { sm24tat4xbNASSwitchStatusEntry 6 } sm24tat4xbNASSwitchStatusPortVLANID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN ID that NAS has put the port in." ::= { sm24tat4xbNASSwitchStatusEntry 7 } --sm24tat4xbNASPortCounterTable sm24tat4xbNASPortCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBNASPortCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NAS Port Counter Table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbNASStatus 2 } sm24tat4xbNASPortCounterEntry OBJECT-TYPE SYNTAX SM24TAT4XBNASPortCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The NAS Port Counter Entry." INDEX { ifIndex } ::= { sm24tat4xbNASPortCounterTable 1 } SM24TAT4XBNASPortCounterEntry ::= SEQUENCE { sm24tat4xbNASReceiveEAPOLTotal Integer32, sm24tat4xbNASReceiveEAPOLResponseID Integer32, sm24tat4xbNASReceiveEAPOLResponses Integer32, sm24tat4xbNASReceiveEAPOLStart Integer32, sm24tat4xbNASReceiveEAPOLLogoff Integer32, sm24tat4xbNASReceiveEAPOLInvalidType Integer32, sm24tat4xbNASReceiveEAPOLInvalidLength Integer32, sm24tat4xbNASTransmitEAPOLTotal Integer32, sm24tat4xbNASTransmitEAPOLRequestID Integer32, sm24tat4xbNASTransmitEAPOLRequests Integer32, sm24tat4xbNASPortReceiveBackendServerAccessChallenges Integer32, sm24tat4xbNASPortReceiveBackendServerOtherRequests Integer32, sm24tat4xbNASPortReceiveBackendServerAuthSuccesses Integer32, sm24tat4xbNASPortReceiveBackendServerAuthFailures Integer32, sm24tat4xbNASPortTransmitBackendServerResponses Integer32, sm24tat4xbNASSupplicantInfoMAC DisplayString, sm24tat4xbNASSupplicantInfoVlanID Integer32, sm24tat4xbNASSupplicantInfoVersion Integer32, sm24tat4xbNASSupplicantInfoIdentity DisplayString, sm24tat4xbNASPortCounterClearCmd ActivateCmd } sm24tat4xbNASReceiveEAPOLTotal OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of valid EAPOL frames of any type that have been received by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 2 } sm24tat4xbNASReceiveEAPOLResponseID OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of valid EAPOL Response Identity frames that have been received by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 3 } sm24tat4xbNASReceiveEAPOLResponses OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of valid EAPOL response frames (other than Response Identity frames) that have been received by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 4 } sm24tat4xbNASReceiveEAPOLStart OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of EAPOL Start frames that have been received by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 5 } sm24tat4xbNASReceiveEAPOLLogoff OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of valid EAPOL Logoff frames that have been received by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 6 } sm24tat4xbNASReceiveEAPOLInvalidType OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of EAPOL frames that have been received by the switch in which the frame type is not recognized. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 7 } sm24tat4xbNASReceiveEAPOLInvalidLength OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of EAPOL frames that have been received by the switch in which the Packet Body Length field is invalid. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 8 } sm24tat4xbNASTransmitEAPOLTotal OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of EAPOL frames of any type that have been transmitted by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 9 } sm24tat4xbNASTransmitEAPOLRequestID OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of EAPOL Request Identity frames that have been transmitted by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 10 } sm24tat4xbNASTransmitEAPOLRequests OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of valid EAPOL Request frames (other than Request Identity frames) that have been transmitted by the switch. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 11 } sm24tat4xbNASPortReceiveBackendServerAccessChallenges OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X-based: Counts the number of times that the switch receives the first request from the backend server following the first response from the supplicant. Indicates that the backend server has communication with the switch. MAC-based:Counts all Access Challenges received from the backend server for this port (left-most table). -1: no support." ::= { sm24tat4xbNASPortCounterEntry 12 } sm24tat4xbNASPortReceiveBackendServerOtherRequests OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X-based: Counts the number of times that the switch sends an EAP Request packet following the first to the supplicant. Indicates that the backend server chose an EAP-method. MAC-based: Not applicable. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 13 } sm24tat4xbNASPortReceiveBackendServerAuthSuccesses OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X- and MAC-based: Counts the number of times that the switch receives a success indication.Indicates that the supplicant has successfully authenticated to the backend server. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 14 } sm24tat4xbNASPortReceiveBackendServerAuthFailures OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X- and MAC-based:Counts the number of times that the switch receives a failure message.This indicates that the supplicant has not authenticated to the backend server. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 15 } sm24tat4xbNASPortTransmitBackendServerResponses OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X-based:Counts the number of times that the switch attempts to send a supplicant's first response packet to the backend server. Indicates the switch attempted communication with the backend server. Possible retransmissions are not counted. MAC-based: Counts all the backend server packets sent from the switch towards the backend server for a given port (left-most table). Possible retransmissions are not counted. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 16 } sm24tat4xbNASSupplicantInfoMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the last supplicant. " ::= { sm24tat4xbNASPortCounterEntry 17 } sm24tat4xbNASSupplicantInfoVlanID OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "The VLAN ID on which the last frame from the last supplicant was received. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 18 } sm24tat4xbNASSupplicantInfoVersion OBJECT-TYPE SYNTAX Integer32(-1..1000000) MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X-based:The protocol version number carried in the most recently received EAPOL frame. MAC-based: Not applicable. -1: no support." ::= { sm24tat4xbNASPortCounterEntry 19 } sm24tat4xbNASSupplicantInfoIdentity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "802.1X-based:The user name (supplicant identity) carried in the most recently received Response Identity EAPOL frame. MAC-based: Not applicable. " ::= { sm24tat4xbNASPortCounterEntry 20 } sm24tat4xbNASPortCounterClearCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Clear the counters for the selected port." ::= { sm24tat4xbNASPortCounterEntry 21 } -- ======================================================================================================================= sm24tat4xbMACConf OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 17 } sm24tat4xbMAC OBJECT IDENTIFIER ::= { sm24tat4xbMACConf 1 } -- -- ======================================================================================================================= -- Start sm24tat4xbMAC group -- ======================================================================================================================= sm24tat4xbMACDisableAutomaticAging OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Disable the automatic aging of dynamic entries." ::= { sm24tat4xbMAC 1 } sm24tat4xbMACAgingTime OBJECT-TYPE SYNTAX Integer32 (-1 | 10..1000000) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure aging time by entering a value here in seconds. range: 10-1000000 seconds. -1: Automatic Aging is disable." ::= { sm24tat4xbMAC 2 } --sm24tat4xbMACLearningTable sm24tat4xbMACLearningTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMACLearningEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The mac learning table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbMAC 3 } sm24tat4xbMACLearningEntry OBJECT-TYPE SYNTAX SM24TAT4XBMACLearningEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The mac learning entry." INDEX { ifIndex } ::= { sm24tat4xbMACLearningTable 1 } SM24TAT4XBMACLearningEntry ::= SEQUENCE { sm24tat4xbMACTableLearning INTEGER } sm24tat4xbMACTableLearning OBJECT-TYPE SYNTAX INTEGER{ auto(0), disable(1), secure(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "auto(0) : Learning is done automatically as soon as a frame with unknown SMAC is received. disable(1): Disable, No learning is done. secure(2) : Secure, Only static MAC entries are learned, all other frames are dropped." ::= { sm24tat4xbMACLearningEntry 2 } sm24tat4xbLearningDisabledVLANs OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The Learning Disabled VLANs" ::= { sm24tat4xbMAC 4 } --sm24tat4xbMACStaticConfigTable sm24tat4xbMACStaticConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMACStaticConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The static Mac config table." ::= { sm24tat4xbMAC 5 } sm24tat4xbMACStaticConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBMACStaticConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The static Mac config entry." INDEX { sm24tat4xbMACStaticConfigIndex } ::= { sm24tat4xbMACStaticConfigTable 1 } SM24TAT4XBMACStaticConfigEntry ::= SEQUENCE { sm24tat4xbMACStaticConfigSwitchIndex Integer32, sm24tat4xbMACStaticConfigIndex Integer32, sm24tat4xbMACStaticConfigVID Integer32, sm24tat4xbMACStaticConfigMACaddress DisplayString, sm24tat4xbMACStaticConfigPortList DisplayString, sm24tat4xbMACStaticConfigRowStatus RowStatus } sm24tat4xbMACStaticConfigSwitchIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch Index." ::= { sm24tat4xbMACStaticConfigEntry 1 } sm24tat4xbMACStaticConfigIndex OBJECT-TYPE SYNTAX Integer32(1..64) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The static entries in the MAC table are shown in this table. The static MAC table can contain 64 entries." ::= { sm24tat4xbMACStaticConfigEntry 2 } sm24tat4xbMACStaticConfigVID OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN ID of the entry. range: 1-4095." ::= { sm24tat4xbMACStaticConfigEntry 3 } sm24tat4xbMACStaticConfigMACaddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The MAC address of the entry." ::= { sm24tat4xbMACStaticConfigEntry 4 } sm24tat4xbMACStaticConfigPortList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Checkmarks indicate which ports are members of the entry. Check or uncheck as needed to modify the entry." ::= { sm24tat4xbMACStaticConfigEntry 5 } sm24tat4xbMACStaticConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbMACStaticConfigEntry 6 } -- ======================================================================================================================= sm24tat4xbSpanningTree OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 18 } sm24tat4xbBridgeSettings OBJECT IDENTIFIER ::= { sm24tat4xbSpanningTree 1 } sm24tat4xbSTPProtocolVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:STP 2:RSTP 3:MSTP" ::= { sm24tat4xbBridgeSettings 1 } sm24tat4xbBridgePriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Priority, range: 0-61440, multiple of 4096." ::= { sm24tat4xbBridgeSettings 2 } sm24tat4xbBridgeForwardDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Forward Delay, range: 4-30 seconds." ::= { sm24tat4xbBridgeSettings 3 } sm24tat4xbBridgeMaxAge OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge MaxAge, range:6-40 seconds." ::= { sm24tat4xbBridgeSettings 4 } sm24tat4xbBridgeMaxHops OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Max Hops, range:6-40 hops." ::= { sm24tat4xbBridgeSettings 5 } sm24tat4xbBridgetxHoldCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge Transmit Hold Count,range: 1-10 bpdu's per second. " ::= { sm24tat4xbBridgeSettings 6 } sm24tat4xbBridgeBPDUFilter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge BPD UFilter 0:disable 1:enable " ::= { sm24tat4xbBridgeSettings 7 } sm24tat4xbBridgeBPDUGuard OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge BPDU Guard 0:disable 1:enable " ::= { sm24tat4xbBridgeSettings 8 } sm24tat4xbBridgeerrorRecoveryDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Bridge error Recovery Delay range:30-86400 seconds 0:disable " ::= { sm24tat4xbBridgeSettings 9 } sm24tat4xbBridgeHelloTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The interval between sending STP BPDU's. Valid values are in the range 1 to 10 seconds, default:2 seconds." ::= { sm24tat4xbBridgeSettings 10 } sm24tat4xbMSTIMapping OBJECT IDENTIFIER ::= { sm24tat4xbSpanningTree 2 } sm24tat4xbConfigName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Configuration Name, identify the VLAN to MSTI mapping" ::= { sm24tat4xbMSTIMapping 1 } sm24tat4xbConfigRevision OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configuration Revision. range:0-65535 " ::= { sm24tat4xbMSTIMapping 2 } sm24tat4xbMSTIMappingVLAN OBJECT IDENTIFIER ::= { sm24tat4xbSpanningTree 3 } sm24tat4xbConfigMstiName1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI1. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 1 } sm24tat4xbConfigMstiName2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI2. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 2 } sm24tat4xbConfigMstiName3 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI3. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 3 } sm24tat4xbConfigMstiName4 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI4. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 4 } sm24tat4xbConfigMstiName5 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI5. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 5 } sm24tat4xbConfigMstiName6 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI6. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 6 } sm24tat4xbConfigMstiName7 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The list of VLANs mapped to the MSTI7. The VLANs can be given as a single (xx, xx being between 1 and 4094) VLAN, or a range (xx-yy), each of which must be separated with comma and/or space. " ::= { sm24tat4xbMSTIMappingVLAN 7 } sm24tat4xbMSTIPriorities OBJECT IDENTIFIER ::= { sm24tat4xbSpanningTree 4 } sm24tat4xbCSTIPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "CSTI Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 1 } sm24tat4xbMSTI1Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI1 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 2 } sm24tat4xbMSTI2Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI2 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 3 } sm24tat4xbMSTI3Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI3 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 4 } sm24tat4xbMSTI4Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI4 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 5 } sm24tat4xbMSTI5Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI5 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 6 } sm24tat4xbMSTI6Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI6 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 7 } sm24tat4xbMSTI7Priority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MSTI7 Priority. range: 0-61440, multiple of 4096. Lower numeric values have better priority." ::= { sm24tat4xbMSTIPriorities 8 } sm24tat4xbCISTPorts OBJECT IDENTIFIER ::= { sm24tat4xbSpanningTree 5 } sm24tat4xbCISTAggregatedEnable OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Enable. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPorts 1 } sm24tat4xbCISTAggregatedPathCost OBJECT-TYPE SYNTAX Integer32 (0..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Path Cost. range: 0-200000000. 0 is Auto." ::= { sm24tat4xbCISTPorts 2 } sm24tat4xbCISTAggregatedPortPriority OBJECT-TYPE SYNTAX Integer32 (0|16|32|48|64|80|96|112|128|144|160|176|192|208|224|240) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Priority. range: 0-240, multiple of 16." ::= { sm24tat4xbCISTPorts 3 } sm24tat4xbCISTAggregatedAdminEdge OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Admin Edge. range: 0-1. 0:Non-Edge 1:Edge." ::= { sm24tat4xbCISTPorts 4 } sm24tat4xbCISTAggregatedAutoEdge OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Auto Edge. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPorts 5 } sm24tat4xbCISTAggregatedrestrictedRole OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port restricted Role. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPorts 6 } sm24tat4xbCISTAggregatedrestrictedTcn OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port restricted Tcn. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPorts 7 } sm24tat4xbCISTAggregatedbpduGuard OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port bpdu Guard. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPorts 8 } sm24tat4xbCISTAggregatedPointToPoint OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Point To Point. range: 0-2. 0:Forced True 1:Forced False. 2:Auto" ::= { sm24tat4xbCISTPorts 9 } sm24tat4xbCISTPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBCISTPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CIST port table." ::= { sm24tat4xbCISTPorts 10 } sm24tat4xbCISTPortsEntry OBJECT-TYPE SYNTAX SM24TAT4XBCISTPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the CIST Ports Table." INDEX { sm24tat4xbCISTPortIndex } ::= { sm24tat4xbCISTPortsTable 1 } SM24TAT4XBCISTPortsEntry ::= SEQUENCE { sm24tat4xbCISTPortIndex Integer32, sm24tat4xbCISTPortEnable Integer32, sm24tat4xbCISTPortPathCost Integer32, sm24tat4xbCISTPortPortPriority Integer32, sm24tat4xbCISTPortAdminEdge Integer32, sm24tat4xbCISTPortAutoEdge Integer32, sm24tat4xbCISTPortrestrictedRole Integer32, sm24tat4xbCISTPortrestrictedTcn Integer32, sm24tat4xbCISTPortbpduGuard Integer32, sm24tat4xbCISTPortPointToPoint Integer32, sm24tat4xbCISTPortRootGuard Integer32 } sm24tat4xbCISTPortIndex OBJECT-TYPE SYNTAX Integer32 (1..53) MAX-ACCESS not-accessible STATUS current DESCRIPTION "CIST Port Index. range: 1-53. 53 is Aggregated Port Configuration." ::= { sm24tat4xbCISTPortsEntry 1 } sm24tat4xbCISTPortEnable OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Enable. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPortsEntry 2 } sm24tat4xbCISTPortPathCost OBJECT-TYPE SYNTAX Integer32 (0..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Path Cost. range: 0-200000000. 0 is Auto." ::= { sm24tat4xbCISTPortsEntry 3 } sm24tat4xbCISTPortPortPriority OBJECT-TYPE SYNTAX Integer32 (0|16|32|48|64|80|96|112|128|144|160|176|192|208|224|240) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Priority. range: 0-240, multiple of 16." ::= { sm24tat4xbCISTPortsEntry 4 } sm24tat4xbCISTPortAdminEdge OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Admin Edge. range: 0-1. 0:Non-Edge 1:Edge." ::= { sm24tat4xbCISTPortsEntry 5 } sm24tat4xbCISTPortAutoEdge OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Auto Edge. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPortsEntry 6 } sm24tat4xbCISTPortrestrictedRole OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port restricted Role. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPortsEntry 7 } sm24tat4xbCISTPortrestrictedTcn OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port restricted Tcn. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPortsEntry 8 } sm24tat4xbCISTPortbpduGuard OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port bpdu Guard. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPortsEntry 9 } sm24tat4xbCISTPortPointToPoint OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port Point To Point. range: 0-2. 0:Forced True 1:Forced False. 2:Auto" ::= { sm24tat4xbCISTPortsEntry 10 } sm24tat4xbCISTPortRootGuard OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "CIST Port root guard. range: 0-1. 0:disable 1:enable." ::= { sm24tat4xbCISTPortsEntry 11 } sm24tat4xbMSTIPorts OBJECT IDENTIFIER ::= { sm24tat4xbSpanningTree 6 } sm24tat4xbMSTIAggregatedPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMSTIAggregatedPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of MSTI ports." ::= { sm24tat4xbMSTIPorts 1 } sm24tat4xbMSTIAggregatedPortsEntry OBJECT-TYPE SYNTAX SM24TAT4XBMSTIAggregatedPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the MSTI ports Table." INDEX { sm24tat4xbMSTIAggregatedPortsMSTIndex } ::= { sm24tat4xbMSTIAggregatedPortsTable 1 } SM24TAT4XBMSTIAggregatedPortsEntry ::= SEQUENCE { sm24tat4xbMSTIAggregatedPortsMSTIndex Integer32, sm24tat4xbMSTIAggregatedPortsPathCost Integer32, sm24tat4xbMSTIAggregatedPortsPortPriority Integer32 } sm24tat4xbMSTIAggregatedPortsMSTIndex OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "MST index, range:1-7" ::= {sm24tat4xbMSTIAggregatedPortsEntry 1 } sm24tat4xbMSTIAggregatedPortsPathCost OBJECT-TYPE SYNTAX Integer32 (0..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "MST Path Cost. range: 0-200000000. 0 is Auto." ::= {sm24tat4xbMSTIAggregatedPortsEntry 3 } sm24tat4xbMSTIAggregatedPortsPortPriority OBJECT-TYPE SYNTAX Integer32 (0|16|32|48|64|80|96|112|128|144|160|176|192|208|224|240) MAX-ACCESS read-write STATUS current DESCRIPTION "MST Port Priority. range: 0-240, multiple of 16." ::= {sm24tat4xbMSTIAggregatedPortsEntry 4 } sm24tat4xbMSTIPortsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMSTIPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of MSTI ports." ::= { sm24tat4xbMSTIPorts 2 } sm24tat4xbMSTIPortsEntry OBJECT-TYPE SYNTAX SM24TAT4XBMSTIPortsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the MSTI ports Table." INDEX { sm24tat4xbMSTIPortsMSTIndex, sm24tat4xbMSTIPortsPortIndex } ::= { sm24tat4xbMSTIPortsTable 1 } SM24TAT4XBMSTIPortsEntry ::= SEQUENCE { sm24tat4xbMSTIPortsMSTIndex Integer32, sm24tat4xbMSTIPortsPortIndex Integer32, sm24tat4xbMSTIPortsPathCost Integer32, sm24tat4xbMSTIPortsPortPriority Integer32 } sm24tat4xbMSTIPortsMSTIndex OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "MST index, range:1-7" ::= {sm24tat4xbMSTIPortsEntry 1 } sm24tat4xbMSTIPortsPortIndex OBJECT-TYPE SYNTAX Integer32 (1..53) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port index, range 1-53, 53 is Aggregated Ports Configuration." ::= {sm24tat4xbMSTIPortsEntry 2 } sm24tat4xbMSTIPortsPathCost OBJECT-TYPE SYNTAX Integer32 (0..200000000) MAX-ACCESS read-write STATUS current DESCRIPTION "MST Path Cost. range: 0-200000000. 0 is Auto." ::= {sm24tat4xbMSTIPortsEntry 3 } sm24tat4xbMSTIPortsPortPriority OBJECT-TYPE SYNTAX Integer32 (0|16|32|48|64|80|96|112|128|144|160|176|192|208|224|240) MAX-ACCESS read-write STATUS current DESCRIPTION "MST Port Priority. range: 0-240, multiple of 16." ::= {sm24tat4xbMSTIPortsEntry 4 } -- ======================================================================================================================= sm24tat4xbPrivateVLANs OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 19 } sm24tat4xbPVLANMembershipTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPVLANMembershipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Private VLAN Membership." ::= { sm24tat4xbPrivateVLANs 1 } sm24tat4xbPVLANMembershipEntry OBJECT-TYPE SYNTAX SM24TAT4XBPVLANMembershipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the private VLAN table." INDEX { sm24tat4xbPVLANMembershipIndex } ::= { sm24tat4xbPVLANMembershipTable 1 } SM24TAT4XBPVLANMembershipEntry ::= SEQUENCE { sm24tat4xbPVLANMembershipIndex Integer32, sm24tat4xbPVLANID Integer32, sm24tat4xbPVLANMembers DisplayString, sm24tat4xbPVLANRowStatus RowStatus } sm24tat4xbPVLANMembershipIndex OBJECT-TYPE SYNTAX Integer32 (1..28) MAX-ACCESS not-accessible STATUS current DESCRIPTION "PVLAN membership index. Range:1-28." ::= {sm24tat4xbPVLANMembershipEntry 1 } sm24tat4xbPVLANID OBJECT-TYPE SYNTAX Integer32 (1..28) MAX-ACCESS read-create STATUS current DESCRIPTION "PVLAN ID. Range:1-28." ::= {sm24tat4xbPVLANMembershipEntry 2 } sm24tat4xbPVLANMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "PVLAN Members. Each octet within this value specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the bridge is represented by a single bit within the value of this object. If that bit has a value of '1', then that port is included in the set of ports; the port is not included if its bit has a value of '0'." ::= {sm24tat4xbPVLANMembershipEntry 3 } sm24tat4xbPVLANRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "PVLAN Row Status." ::= {sm24tat4xbPVLANMembershipEntry 4 } sm24tat4xbPVLANPortIsolationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPVLANPortIsolationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of Private VLAN Port Isolation." ::= { sm24tat4xbPrivateVLANs 2 } sm24tat4xbPVLANPortIsolationEntry OBJECT-TYPE SYNTAX SM24TAT4XBPVLANPortIsolationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the private VLAN table." INDEX { sm24tat4xbPVLANPortIsolationIndex } ::= { sm24tat4xbPVLANPortIsolationTable 1 } SM24TAT4XBPVLANPortIsolationEntry ::= SEQUENCE { sm24tat4xbPVLANPortIsolationIndex Integer32, sm24tat4xbPVLANPortIsolationPortMembers Integer32 } sm24tat4xbPVLANPortIsolationIndex OBJECT-TYPE SYNTAX Integer32 (1..28) MAX-ACCESS not-accessible STATUS current DESCRIPTION "PVLAN Port Isolation Index. Range:1-28." ::= {sm24tat4xbPVLANPortIsolationEntry 1 } sm24tat4xbPVLANPortIsolationPortMembers OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "PVLAN Port Isolation Port Members enable/disable. Range:0-1. 1:Port Isolation enable on that port. 0:Port Isolation disable on that port." ::= {sm24tat4xbPVLANPortIsolationEntry 2 } -- ======================================================================================================================= sm24tat4xbsFlow OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 20 } sm24tat4xbsFlowVersion OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Uniquely identifies the version and implementation of this MIB. The version string must have the following structure: ;; where: must be '1.3', the version of this MIB. the name of the organization responsible for the agent implementation. the specific software build of this agent. As an example, the string '1.3;InMon Corp.;2.1.1' indicates that this agent implements version '1.2' of the SFLOW MIB, that it was developed by 'InMon Corp.' and that the software build is '2.1.1'. The MIB Version will change with each revision of the SFLOW MIB. Management entities must check the MIB Version and not attempt to manage agents with MIB Versions greater than that for which they were designed. Note: The sFlow Datagram Format has an independent version number which may change independently from . applies to the structure and semantics of the SFLOW MIB only." DEFVAL { "1.3;;" } ::= { sm24tat4xbsFlow 1 } sm24tat4xbsFlowAgentAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The address type of the address associated with this agent. Only ipv4 and ipv6 types are supported. ipv4:1, ipv6:2." ::= { sm24tat4xbsFlow 2 } sm24tat4xbsFlowAgentAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address associated with this agent. In the case of a multi-homed agent, this should be the loopback address of the agent. The sFlowAgent address must provide SNMP connectivity to the agent. The address should be an invariant that does not change as interfaces are reconfigured, enabled, disabled, added or removed. A manager should be able to use the sFlowAgentAddress as a unique key that will identify this agent over extended periods of time so that a history can be maintained." ::= { sm24tat4xbsFlow 3 } -- -- Receiver Table -- sm24tat4xbsFlowRcvrTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSFlowRcvrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the receivers of sFlow information." ::= { sm24tat4xbsFlow 4 } sm24tat4xbsFlowRcvrEntry OBJECT-TYPE SYNTAX SM24TAT4XBSFlowRcvrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of an sFlow Receiver." INDEX { sm24tat4xbsFlowRcvrIndex } ::= { sm24tat4xbsFlowRcvrTable 1 } SM24TAT4XBSFlowRcvrEntry ::= SEQUENCE { sm24tat4xbsFlowRcvrIndex Integer32, sm24tat4xbsFlowRcvrOwner OwnerString, sm24tat4xbsFlowRcvrTimeout Integer32, sm24tat4xbsFlowRcvrMaximumDatagramSize Integer32, sm24tat4xbsFlowRcvrAddressType InetAddressType, sm24tat4xbsFlowRcvrAddress IpAddress, sm24tat4xbsFlowRcvrPort Integer32, sm24tat4xbsFlowRcvrDatagramVersion Integer32 } sm24tat4xbsFlowRcvrIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index into sFlowReceiverTable." ::= { sm24tat4xbsFlowRcvrEntry 1 } sm24tat4xbsFlowRcvrOwner OBJECT-TYPE SYNTAX OwnerString MAX-ACCESS read-write STATUS current DESCRIPTION "The entity making use of this sFlowRcvrTable entry. The empty string indicates that the entry is currently unclaimed. An entity wishing to claim an sFlowRcvrTable entry must ensure that the entry is unclaimed before trying to claim it. The entry is claimed by setting the owner string. The entry must be claimed before any changes can be made to other sampler objects. In order to avoid a race condition, the entity taking control of the sampler must set both the owner and a value for sFlowRcvrTimeout in the same SNMP set request. When a management entity is finished using the sampler, it should set the value of sFlowRcvrOwner back to unclaimed. The agent must restore all other entities this row to their default values when the owner is set to unclaimed. It must also free all other resources associated with this sFlowRcvrTable entry. This mechanism provides no enforcement and relies on the cooperation of management entities in order to ensure that competition for a receiver entry is fairly resolved." DEFVAL { "" } ::= { sm24tat4xbsFlowRcvrEntry 2 } sm24tat4xbsFlowRcvrTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time (in seconds) remaining before the sampler is released and stops sampling. When set, the owner establishes control for the specified period. When read, the remaining time in the interval is returned. A management entity wanting to maintain control of the sampler is responsible for setting a new value before the old one expires. When the interval expires, the agent is responsible for restoring all other entities in this row to their default values. It must also free all other resources associated with this sFlowRcvrTable entry." DEFVAL { 0 } ::= { sm24tat4xbsFlowRcvrEntry 3 } sm24tat4xbsFlowRcvrMaximumDatagramSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of data bytes that can be sent in a single sample datagram. The manager should set this value to avoid fragmentation of the sFlow datagrams." DEFVAL { 1400 } ::= { sm24tat4xbsFlowRcvrEntry 4 } sm24tat4xbsFlowRcvrAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "The type of sFlowRcvrCollectorAddress." DEFVAL { ipv4 } ::= { sm24tat4xbsFlowRcvrEntry 5 } sm24tat4xbsFlowRcvrAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of the sFlow collector. If set to 0.0.0.0 not sFlow datagrams will be sent." DEFVAL { '00000000'h } -- 0.0.0.0 ::= { sm24tat4xbsFlowRcvrEntry 6 } sm24tat4xbsFlowRcvrPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The destination port for sFlow datagrams." DEFVAL { 6343 } ::= { sm24tat4xbsFlowRcvrEntry 7 } sm24tat4xbsFlowRcvrDatagramVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The version of sFlow datagrams that should be sent. When set to a value not support by the agent, the agent should adjust the value to the highest supported value less than the requested value, or return an SNMP bad value error if no such value exists." DEFVAL { 5 } ::= { sm24tat4xbsFlowRcvrEntry 8 } -- -- Flow Sampling Table -- sm24tat4xbsFlowFsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSFlowFsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the flow samplers within a device." ::= { sm24tat4xbsFlow 5 } sm24tat4xbsFlowFsEntry OBJECT-TYPE SYNTAX SM24TAT4XBSFlowFsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a flow sampler." INDEX { sm24tat4xbsFlowFsDataSource, sm24tat4xbsFlowFsInstance } ::= { sm24tat4xbsFlowFsTable 1 } SM24TAT4XBSFlowFsEntry ::= SEQUENCE { sm24tat4xbsFlowFsDataSource Integer32, sm24tat4xbsFlowFsInstance Integer32, sm24tat4xbsFlowFsReceiver Integer32, sm24tat4xbsFlowFsPacketSamplingRate Integer32, sm24tat4xbsFlowFsMaximumHeaderSize Integer32, sm24tat4xbsFlowFsType Integer32 } sm24tat4xbsFlowFsDataSource OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "sFlowDataSource for this flow sampler." ::= { sm24tat4xbsFlowFsEntry 1 } sm24tat4xbsFlowFsInstance OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sFlow instance for this flow sampler." ::= { sm24tat4xbsFlowFsEntry 2 } sm24tat4xbsFlowFsReceiver OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SFlowReceiver for this flow sampler." DEFVAL { 0 } ::= { sm24tat4xbsFlowFsEntry 3 } sm24tat4xbsFlowFsPacketSamplingRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The statistical sampling rate for packet sampling from this source. Set to N to sample 1/Nth of the packets in the monitored flows. An agent should choose its own algorithm to introduce variance into the sampling so that exactly every Nth packet is not counted. A sampling rate of 1 counts all packets. A sampling rate of 0 disables sampling. The agent is permitted to have minimum and maximum allowable values for the sampling rate. A minimum rate lets the agent designer set an upper bound on the overhead associated with sampling, and a maximum rate may be the result of hardware restrictions (such as counter size). In addition not all values between the maximum and minimum may be realizable as the sampling rate (again because of implementation considerations). When the sampling rate is set the agent is free to adjust the value so that it lies between the maximum and minimum values and has the closest achievable value. When read, the agent must return the actual sampling rate it will be using (after the adjustments previously described). The sampling algorithm must converge so that over time the number of packets sampled approaches 1/Nth of the total number of packets in the monitored flows." DEFVAL { 0 } ::= { sm24tat4xbsFlowFsEntry 4 } sm24tat4xbsFlowFsMaximumHeaderSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of bytes that should be copied from a sampled packet. The agent may have an internal maximum and minimum permissible sizes. If an attempt is made to set this value outside the permissible range then the agent should adjust the value to the closest permissible value." DEFVAL { 128 } ::= { sm24tat4xbsFlowFsEntry 5 } sm24tat4xbsFlowFsType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Flow Sample Type. 1:Rx 2:Tx 3:All." DEFVAL { 2 } ::= { sm24tat4xbsFlowFsEntry 6 } -- -- Counter Polling Table -- sm24tat4xbsFlowCpTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSFlowCpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of the counter pollers within a device." ::= { sm24tat4xbsFlow 6 } sm24tat4xbsFlowCpEntry OBJECT-TYPE SYNTAX SM24TAT4XBSFlowCpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Attributes of a counter poller." INDEX { sm24tat4xbsFlowCpDataSource, sm24tat4xbsFlowCpInstance } ::= { sm24tat4xbsFlowCpTable 1 } SM24TAT4XBSFlowCpEntry ::= SEQUENCE { sm24tat4xbsFlowCpDataSource Integer32, sm24tat4xbsFlowCpInstance Integer32, sm24tat4xbsFlowCpReceiver Integer32, sm24tat4xbsFlowCpInterval Integer32 } sm24tat4xbsFlowCpDataSource OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Identifies the source of the data for the counter poller." ::= { sm24tat4xbsFlowCpEntry 1 } sm24tat4xbsFlowCpInstance OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The sFlowInstance for this counter poller." ::= { sm24tat4xbsFlowCpEntry 2 } sm24tat4xbsFlowCpReceiver OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The SFlowReciever associated with this counter poller." DEFVAL { 0 } ::= { sm24tat4xbsFlowCpEntry 3 } sm24tat4xbsFlowCpInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The maximum number of seconds between successive samples of the counters associated with this data source. A sampling interval of 0 disables counter sampling. The agent is permitted to have minimum and maximum allowable values for the counter polling interval. A minimum interval lets the agent designer set an upper bound on the overhead associated with polling, and a maximum interval may be the result of implementation restrictions (such as counter size). In addition not all values between the maximum and minimum may be realizable as the sampling interval (again because of implementation considerations). When the sampling rate is set the agent is free to adjust the value so that it lies between the maximum and minimum values and has the closest achievable value. When read, the agent must return the actual sampling interval it will be using (after the adjustments previously described). The sampling algorithm must converge so that over time the number of packets sampled approaches 1/Nth of the total number of packets in the monitored flows." DEFVAL { 0 } ::= { sm24tat4xbsFlowCpEntry 4 } sm24tat4xbLLDP OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 21 } sm24tat4xbLLDPConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLLDPConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDP 1 } sm24tat4xbLLDPConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBLLDPConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLLDPIndex } ::= { sm24tat4xbLLDPConfTable 1 } SM24TAT4XBLLDPConfEntry ::= SEQUENCE { sm24tat4xbLLDPIndex Integer32, sm24tat4xbLLDPMode Integer32, sm24tat4xbLLDPCDPAware Integer32, sm24tat4xbLLDPTrap Integer32, sm24tat4xbLLDPPortDescr Integer32, sm24tat4xbLLDPSysName Integer32, sm24tat4xbLLDPSysDescr Integer32, sm24tat4xbLLDPSysCapa Integer32, sm24tat4xbLLDPMgmtAddr Integer32 } sm24tat4xbLLDPIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "LLDP configuration index." ::= { sm24tat4xbLLDPConfEntry 1 } sm24tat4xbLLDPMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Tx only 2:Rx only 3:Enabled" ::= { sm24tat4xbLLDPConfEntry 2 } sm24tat4xbLLDPCDPAware OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 3 } sm24tat4xbLLDPTrap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 4 } sm24tat4xbLLDPPortDescr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 5 } sm24tat4xbLLDPSysName OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 6 } sm24tat4xbLLDPSysDescr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 7 } sm24tat4xbLLDPSysCapa OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 8 } sm24tat4xbLLDPMgmtAddr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPConfEntry 9 } sm24tat4xbLLDPMEDCoordinatesLocation OBJECT IDENTIFIER ::= { sm24tat4xbLLDP 2 } sm24tat4xbLLDPMEDLatitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Latitude SHOULD be normalized to within 0-90 degrees with a maximum of 4 digits." ::= { sm24tat4xbLLDPMEDCoordinatesLocation 2 } sm24tat4xbLLDPMEDLatitudeDirection OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "0:North 1:South" ::= { sm24tat4xbLLDPMEDCoordinatesLocation 3 } sm24tat4xbLLDPMEDLongitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Longitude SHOULD be normalized to within 0-180 degrees with a maximum of 4 digits." ::= { sm24tat4xbLLDPMEDCoordinatesLocation 4 } sm24tat4xbLLDPMEDLongitudeDirection OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "0:East 1:West" ::= { sm24tat4xbLLDPMEDCoordinatesLocation 5 } sm24tat4xbLLDPMEDAltitude OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Altitude SHOULD be normalized to within -2097151.9 to 2097151.9 with a maximum of 1 digits." ::= { sm24tat4xbLLDPMEDCoordinatesLocation 6 } sm24tat4xbLLDPMEDAltitudeType OBJECT-TYPE SYNTAX Integer32(1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "1:Meters 2:Floors" ::= { sm24tat4xbLLDPMEDCoordinatesLocation 7 } sm24tat4xbLLDPMEDMapDatum OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "The Map Datum is used for the coordinates given in these options: 1:WGS84 2:NAD83/NAVD88 3:NAD83/MLLW " ::= { sm24tat4xbLLDPMEDCoordinatesLocation 8 } sm24tat4xbLLDPMEDCivicAddressLocation OBJECT IDENTIFIER ::= { sm24tat4xbLLDP 4 } sm24tat4xbLLDPMEDCivicAddressLocationCountryCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 2 } sm24tat4xbLLDPMEDCivicAddressLocationStateProvince OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 3 } sm24tat4xbLLDPMEDCivicAddressLocationCounty OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 4 } sm24tat4xbLLDPMEDCivicAddressLocationCity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 5 } sm24tat4xbLLDPMEDCivicAddressLocationCityDistrict OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 6 } sm24tat4xbLLDPMEDCivicAddressLocationBlockNeighborhood OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 7 } sm24tat4xbLLDPMEDCivicAddressLocationStreet OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 8 } sm24tat4xbLLDPMEDCivicAddressLocationLeadingStreetDirection OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 9 } sm24tat4xbLLDPMEDCivicAddressLocationTrailingStreetSuffix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 10 } sm24tat4xbLLDPMEDCivicAddressLocationStreetSuffix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 11 } sm24tat4xbLLDPMEDCivicAddressLocationHouseNo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 12 } sm24tat4xbLLDPMEDCivicAddressLocationHouseNoSuffix OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 13 } sm24tat4xbLLDPMEDCivicAddressLocationLandmark OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 14 } sm24tat4xbLLDPMEDCivicAddressLocationAdditionalLocationInfo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 15 } sm24tat4xbLLDPMEDCivicAddressLocationName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 16 } sm24tat4xbLLDPMEDCivicAddressLocationZipCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 17 } sm24tat4xbLLDPMEDCivicAddressLocationBuilding OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 18 } sm24tat4xbLLDPMEDCivicAddressLocationApartment OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 19 } sm24tat4xbLLDPMEDCivicAddressLocationFloor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 20 } sm24tat4xbLLDPMEDCivicAddressLocationRoomNo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 21 } sm24tat4xbLLDPMEDCivicAddressLocationPlaceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 22 } sm24tat4xbLLDPMEDCivicAddressLocationPostalCommunityName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 23 } sm24tat4xbLLDPMEDCivicAddressLocationPOBox OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 24 } sm24tat4xbLLDPMEDCivicAddressLocationAdditionalCode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDCivicAddressLocation 25 } sm24tat4xbLLDPMEDPoliciesTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLLDPMEDPoliciesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDP 5 } sm24tat4xbLLDPMEDPoliciesEntry OBJECT-TYPE SYNTAX SM24TAT4XBLLDPMEDPoliciesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLLDPMEDPoliciesIndex } ::= { sm24tat4xbLLDPMEDPoliciesTable 1 } SM24TAT4XBLLDPMEDPoliciesEntry ::= SEQUENCE { sm24tat4xbLLDPMEDPoliciesIndex Integer32, sm24tat4xbLLDPMEDPoliciesPolicyID Integer32, sm24tat4xbLLDPMEDPoliciesApplicationType Integer32, sm24tat4xbLLDPMEDPoliciesTag Integer32, sm24tat4xbLLDPMEDPoliciesVLANID Integer32, sm24tat4xbLLDPMEDPoliciesL2Priority Integer32, sm24tat4xbLLDPMEDPoliciesDSCP Integer32, sm24tat4xbLLDPMEDPoliciesRowStatus RowStatus } sm24tat4xbLLDPMEDPoliciesIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbLLDPMEDPoliciesEntry 1 } sm24tat4xbLLDPMEDPoliciesPolicyID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDPMEDPoliciesEntry 2 } sm24tat4xbLLDPMEDPoliciesApplicationType OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "1:Voice 2:Voice Signalling 3:Guest Voice 4:Guest Voice Signalling 5:Softphone Voice 6:Video Conferencing 7:Streaming Video 8:Video Signalling" ::= { sm24tat4xbLLDPMEDPoliciesEntry 3 } sm24tat4xbLLDPMEDPoliciesTag OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "0:Untagged 1:Tagged" ::= { sm24tat4xbLLDPMEDPoliciesEntry 4 } sm24tat4xbLLDPMEDPoliciesVLANID OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "Range:1-4095" ::= { sm24tat4xbLLDPMEDPoliciesEntry 5 } sm24tat4xbLLDPMEDPoliciesL2Priority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Range:0-7" ::= { sm24tat4xbLLDPMEDPoliciesEntry 6 } sm24tat4xbLLDPMEDPoliciesDSCP OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Range:0-63" ::= { sm24tat4xbLLDPMEDPoliciesEntry 7 } sm24tat4xbLLDPMEDPoliciesRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= { sm24tat4xbLLDPMEDPoliciesEntry 8 } sm24tat4xbLLDPMEDPolicyPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLLDPMEDPolicyPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDP 6 } sm24tat4xbLLDPMEDPolicyPortConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBLLDPMEDPolicyPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLLDPMEDPolicyPortConfPort } ::= { sm24tat4xbLLDPMEDPolicyPortConfTable 1 } SM24TAT4XBLLDPMEDPolicyPortConfEntry ::= SEQUENCE { sm24tat4xbLLDPMEDPolicyPortConfPort Integer32, sm24tat4xbLLDPMEDPolicyPortConf Integer32 } sm24tat4xbLLDPMEDPolicyPortConfPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbLLDPMEDPolicyPortConfEntry 1 } sm24tat4xbLLDPMEDPolicyPortConf OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "0:Disable 1:Enable" ::= { sm24tat4xbLLDPMEDPolicyPortConfEntry 2 } sm24tat4xbLLDPMEDFastStartRepeatCount OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Range:1-10" ::= { sm24tat4xbLLDP 7 } sm24tat4xbLLDPMEDEmergencyCallService OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbLLDP 8 } sm24tat4xbUDLD OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 22 } sm24tat4xbUDLDPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBUDLDPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLD 1 } sm24tat4xbUDLDPortConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBUDLDPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbUDLDPort } ::= { sm24tat4xbUDLDPortConfigTable 1 } SM24TAT4XBUDLDPortConfigEntry ::= SEQUENCE { sm24tat4xbUDLDPort Integer32, sm24tat4xbUDLDPortMode Integer32, sm24tat4xbUDLDPortMessageInterval Integer32 } sm24tat4xbUDLDPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortConfigEntry 1 } sm24tat4xbUDLDPortMode OBJECT-TYPE SYNTAX Integer32 (0|1|2) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: Normal 2: Aggressive" ::= { sm24tat4xbUDLDPortConfigEntry 2 } sm24tat4xbUDLDPortMessageInterval OBJECT-TYPE SYNTAX Integer32(7..90) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 7, range: 7-90" ::= { sm24tat4xbUDLDPortConfigEntry 3 } sm24tat4xbUDLDPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBUDLDPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLD 2 } sm24tat4xbUDLDPortStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBUDLDPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbUDLDPortStatusPort } ::= { sm24tat4xbUDLDPortStatusTable 1 } SM24TAT4XBUDLDPortStatusEntry ::= SEQUENCE { sm24tat4xbUDLDPortStatusPort Integer32, sm24tat4xbUDLDStatusAdminState Integer32, sm24tat4xbUDLDStatusDeviceIDLocal DisplayString, sm24tat4xbUDLDStatusDeviceNameLocal DisplayString, sm24tat4xbUDLDStatusBidirectionalState DisplayString } sm24tat4xbUDLDPortStatusPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port index" ::= { sm24tat4xbUDLDPortStatusEntry 1 } sm24tat4xbUDLDStatusAdminState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbUDLDPortStatusEntry 2 } sm24tat4xbUDLDStatusDeviceIDLocal OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortStatusEntry 3 } sm24tat4xbUDLDStatusDeviceNameLocal OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortStatusEntry 4 } sm24tat4xbUDLDStatusBidirectionalState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortStatusEntry 5 } sm24tat4xbUDLDStatusPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify port number for check neighbour status" ::= { sm24tat4xbUDLD 3 } sm24tat4xbUDLDPortNeighbourStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBUDLDPortNeighbourStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLD 4 } sm24tat4xbUDLDPortNeighbourStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBUDLDPortNeighbourStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbUDLDNeighbourPort } ::= { sm24tat4xbUDLDPortNeighbourStatusTable 1 } SM24TAT4XBUDLDPortNeighbourStatusEntry ::= SEQUENCE { sm24tat4xbUDLDNeighbourPort Integer32, sm24tat4xbUDLDNeighbourStatusPort DisplayString, sm24tat4xbUDLDNeighbourStatusDeviceId DisplayString, sm24tat4xbUDLDNeighbourStatusLinkStatus DisplayString, sm24tat4xbUDLDNeighbourStatusDeviceName DisplayString } sm24tat4xbUDLDNeighbourPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbUDLDPortNeighbourStatusEntry 1 } sm24tat4xbUDLDNeighbourStatusPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortNeighbourStatusEntry 2 } sm24tat4xbUDLDNeighbourStatusDeviceId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortNeighbourStatusEntry 3 } sm24tat4xbUDLDNeighbourStatusLinkStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortNeighbourStatusEntry 4 } sm24tat4xbUDLDNeighbourStatusDeviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbUDLDPortNeighbourStatusEntry 5 } -- ======================================================================================================================= sm24tat4xbEPS OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 23 } sm24tat4xbEPSTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEPSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of EPS." ::= { sm24tat4xbEPS 1 } sm24tat4xbEPSEntry OBJECT-TYPE SYNTAX SM24TAT4XBEPSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sm24tat4xbEPSIndex } ::= { sm24tat4xbEPSTable 1 } SM24TAT4XBEPSEntry ::= SEQUENCE { sm24tat4xbEPSIndex Integer32, sm24tat4xbEpsID Integer32, sm24tat4xbEpsDomain Integer32, sm24tat4xbEpsArchitecture Integer32, sm24tat4xbEpsWFlow Integer32, sm24tat4xbEpsPFlow Integer32, sm24tat4xbEpsWSFMEP Integer32, sm24tat4xbEpsPSFMEP Integer32, sm24tat4xbEpsAPSMEP Integer32, sm24tat4xbEpsAlarm Integer32, sm24tat4xbEpsRowStatus RowStatus } sm24tat4xbEPSIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEPSEntry 1 } sm24tat4xbEpsID OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-create STATUS current DESCRIPTION "EPS ID. Range:1-100." ::= {sm24tat4xbEPSEntry 2 } sm24tat4xbEpsDomain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "EPS Domain. Range:0. 0:Domain is Port" ::= {sm24tat4xbEPSEntry 3 } sm24tat4xbEpsArchitecture OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "EPS Architecture. Range:0-1. 0:Architecture is 1+1 1:Architecture is 1:1" ::= {sm24tat4xbEPSEntry 4 } sm24tat4xbEpsWFlow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The working flow for the EPS." ::= {sm24tat4xbEPSEntry 5 } sm24tat4xbEpsPFlow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The protecting flow for the EPS" ::= {sm24tat4xbEPSEntry 6 } sm24tat4xbEpsWSFMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The working Signal Fail reporting MEP." ::= {sm24tat4xbEPSEntry 7 } sm24tat4xbEpsPSFMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The protecting Signal Fail reporting MEP." ::= {sm24tat4xbEPSEntry 8 } sm24tat4xbEpsAPSMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The APS PDU handling MEP." ::= {sm24tat4xbEPSEntry 9 } sm24tat4xbEpsAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "There is an active alarm on the EPS." ::= {sm24tat4xbEPSEntry 10 } sm24tat4xbEpsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "EPS Row Status." ::= {sm24tat4xbEPSEntry 11 } sm24tat4xbEpsConfigInstanceEpsID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify EPS ID for table uesd." ::= {sm24tat4xbEPS 2 } sm24tat4xbEPSConfigInstanceEntry OBJECT IDENTIFIER ::= { sm24tat4xbEPS 3 } sm24tat4xbEpsConfigInstanceProtectionType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Range:0-1. 0:Unidirectional: EPS in the two ends can select traffic from different working/protecting flow. This is only possible in case of 1+1. 1:Bidirectional: EPS in the two ends is selecting traffic from the same working/protecting flow. This requires APS enabled. This is mandatory for 1:1" ::= { sm24tat4xbEPSConfigInstanceEntry 2 } sm24tat4xbEpsConfigInstanceAPS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Range:0-1. 0:disable 1:enable The Automatic Protection Switching protocol can be enabled/disabled. This is mandatory for 1:1." ::= { sm24tat4xbEPSConfigInstanceEntry 3 } sm24tat4xbEpsConfigInstanceRevertive OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Range:0-1. 0:disable 1:enable The revertive switching to working flow can be enabled/disabled. " ::= { sm24tat4xbEPSConfigInstanceEntry 4 } sm24tat4xbEpsConfigInstanceWTRTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Wait To Restore timing value to be used in revertive switching. Range is 1 to 720 seconds. " ::= { sm24tat4xbEPSConfigInstanceEntry 5 } sm24tat4xbEpsConfigInstanceHoldOffTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The timing value to be used to make persistent check on Signal Fail before switching. This is in 100 ms. and the max value is 100 (10 sec)." ::= { sm24tat4xbEPSConfigInstanceEntry 6 } sm24tat4xbEpsConfigInstanceCommand OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:None 1:Clear 2:Lock Out 3:Forced switch 4:Manual switch P 5:Manual switch W 6:Exercise 7:Freeze 8:Lock Out Local " ::= { sm24tat4xbEPSConfigInstanceEntry 7 } sm24tat4xbEpsStatusProtectionState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "EPS state according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 8 } sm24tat4xbEpsStatusWorkingFlowState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "OK: State of working flow is ok SF: State of working flow is Signal Fail SD: State of working flow is Signal Degrade (for future use) " ::= { sm24tat4xbEPSConfigInstanceEntry 9 } sm24tat4xbEpsStatusProtectingFlowState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "OK: State of protecting flow is ok SF: State of protecting flow is Signal Fail SD: State of protecting flow is Signal Degrade (for future use) " ::= { sm24tat4xbEPSConfigInstanceEntry 10 } sm24tat4xbEpsStatusTransmittedApsRequest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted APS according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 11 } sm24tat4xbEpsStatusTransmittedApsReSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted APS according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 12 } sm24tat4xbEpsStatusTransmittedApsBrSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted APS according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 13 } sm24tat4xbEpsStatusReceivedApsRequest OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The received APS according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 14 } sm24tat4xbEpsStatusReceivedApsReSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received APS according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 15 } sm24tat4xbEpsStatusReceivedApsBrSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The received APS according to State Transition Tables in G.8031. " ::= { sm24tat4xbEPSConfigInstanceEntry 16 } sm24tat4xbEpsStatusArchitectureMismatch OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The architecture indicated in the received APS does not match the locally configured. " ::= { sm24tat4xbEPSConfigInstanceEntry 17 } sm24tat4xbEpsStatusAPSOnWorking OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "APS is received on the working flow. " ::= { sm24tat4xbEPSConfigInstanceEntry 18 } sm24tat4xbEpsStatusSwitchingIncomplete OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Traffic is not selected from the same flow instance in the two ends. " ::= { sm24tat4xbEPSConfigInstanceEntry 19 } sm24tat4xbEpsStatusNoApsReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "APS PDU is not received from the other end. " ::= { sm24tat4xbEPSConfigInstanceEntry 20 } -- ======================================================================================================================= sm24tat4xbERPS OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 24 } sm24tat4xbERPSTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBERPSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ERPS." ::= { sm24tat4xbERPS 1 } sm24tat4xbERPSEntry OBJECT-TYPE SYNTAX SM24TAT4XBERPSEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sm24tat4xbErpsIndex } ::= { sm24tat4xbERPSTable 1 } SM24TAT4XBERPSEntry ::= SEQUENCE { sm24tat4xbErpsIndex Integer32, sm24tat4xbErpsID Integer32, sm24tat4xbErpsPort0 Integer32, sm24tat4xbErpsPort1 Integer32, sm24tat4xbErpsPort0APSMEP Integer32, sm24tat4xbErpsPort1APSMEP Integer32, sm24tat4xbErpsPort0SFMEP Integer32, sm24tat4xbErpsPort1SFMEP Integer32, sm24tat4xbErpsRingType Integer32, sm24tat4xbErpsInterconnectedNode Integer32, sm24tat4xbErpsVirtualChannel Integer32, sm24tat4xbErpsMajorRingID Integer32, sm24tat4xbErpsAlarm Integer32, sm24tat4xbErpsRowStatus RowStatus } sm24tat4xbErpsIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbERPSEntry 1 } sm24tat4xbErpsID OBJECT-TYPE SYNTAX Integer32 (1..64) MAX-ACCESS read-create STATUS current DESCRIPTION "ERPS ID. Range:1-64." ::= {sm24tat4xbERPSEntry 2 } sm24tat4xbErpsPort0 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This will create a Port 0 of the switch in the ring." ::= {sm24tat4xbERPSEntry 3 } sm24tat4xbErpsPort1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This will create Port 1 of the switch in the Ring. As interconnected sub-ring will have only one ring port, Port 1 is configured as 0 for interconnected sub-ring. 0 in this field indicates that no Port 1 is associated with this instance" ::= {sm24tat4xbERPSEntry 4 } sm24tat4xbErpsPort0APSMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The Port 0 APS PDU handling MEP. Range: 1-100." ::= {sm24tat4xbERPSEntry 5 } sm24tat4xbErpsPort1APSMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The Port 1 APS PDU handling MEP. Range: 1-100." ::= {sm24tat4xbERPSEntry 6 } sm24tat4xbErpsPort0SFMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The Port 0 Signal Fail reporting MEP. Range: 1-100." ::= {sm24tat4xbERPSEntry 7 } sm24tat4xbErpsPort1SFMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The Port 1 Signal Fail reporting MEP. Range: 1-100." ::= {sm24tat4xbERPSEntry 8 } sm24tat4xbErpsRingType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Type of Protecting ring. It can be either major ring or sub-ring. 0:Major 1:Sub" ::= {sm24tat4xbERPSEntry 9 } sm24tat4xbErpsInterconnectedNode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Interconnected Node indicates that the ring instance is interconnected. 0: not interconnected 1: interconnected" ::= {sm24tat4xbERPSEntry 10 } sm24tat4xbErpsVirtualChannel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "1: indicates it is a sub-ring with virtual channel. 0: indicates, sub-ring doesn't have virtual channel." ::= {sm24tat4xbERPSEntry 11 } sm24tat4xbErpsMajorRingID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Major ring group ID for the interconnected sub-ring. Range:1-64" ::= {sm24tat4xbERPSEntry 12 } sm24tat4xbErpsAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "There is an active alarm on the ERPS." ::= {sm24tat4xbERPSEntry 13 } sm24tat4xbErpsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ERPS Row Status." ::= {sm24tat4xbERPSEntry 14 } sm24tat4xbErpsConfigInstanceErpsID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify ERPS ID for ERPSConfigInstanceEntry and ErpsConfigInstanceVLANConfigTable uesd." ::= {sm24tat4xbERPS 2 } sm24tat4xbERPSConfigInstanceEntry OBJECT IDENTIFIER ::= { sm24tat4xbERPS 3 } sm24tat4xbErpsConfigInstanceConfigured OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Down: This ERPS is only created and has not yet been configured - is not active. Up: This ERPS is configured - is active." ::= { sm24tat4xbERPSConfigInstanceEntry 2 } sm24tat4xbErpsConfigInstanceGuardTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The period of the guard timer can be configured in 10 ms steps between 10 ms and 2 seconds, with a default value of 500 ms. Guard timeout value to be used to prevent ring nodes from receiving outdated R-APS messages." ::= { sm24tat4xbERPSConfigInstanceEntry 3 } sm24tat4xbErpsConfigInstanceWTRTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Wait To Restore timing value to be used in revertive switching. The period of the WTR time can be configured by the operator in 1 minute steps between 5 and 12 minutes with a default value of 5 minutes. " ::= { sm24tat4xbERPSConfigInstanceEntry 4 } sm24tat4xbErpsConfigInstanceHoldOffTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The timing value to be used to make persistent check on Signal Fail before switching. The range of the hold off timer is 0 to 10 seconds in steps of 100 ms " ::= { sm24tat4xbERPSConfigInstanceEntry 5 } sm24tat4xbErpsConfigInstanceVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "ERPS Protocol Version - v1 or v2 1:v1 2:v2" ::= { sm24tat4xbERPSConfigInstanceEntry 6 } sm24tat4xbErpsConfigInstanceRevertive OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1:Revertive mode 0:Non-Revertive mode" ::= { sm24tat4xbERPSConfigInstanceEntry 7 } sm24tat4xbErpsConfigInstanceRPLRole OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "It can be either RPL owner or RPL Neighbor. 0:None 1:RPL owner 2:RPL Neighbor Please set RPLPort first. " ::= { sm24tat4xbERPSConfigInstanceEntry 8 } sm24tat4xbErpsConfigInstanceRPLPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This allows to select the east port or west port as the RPL block. 0:None 1:Port0 2:Port1 Please set RPLRole after specify RPLPort. " ::= { sm24tat4xbERPSConfigInstanceEntry 9 } sm24tat4xbErpsConfigInstanceClear OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If the owner has to be changed, then the clear check box allows to clear the RPL owner for that ERPS ring. 0: no clear 1: clear " ::= { sm24tat4xbERPSConfigInstanceEntry 10 } sm24tat4xbErpsConfigInstanceTopologyChange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1: indicates that the topology changes in the sub-ring are propagated in the major ring. 0: indicates that the topology changes in the sub-ring are not propagated in the major ring. " ::= { sm24tat4xbERPSConfigInstanceEntry 11 } sm24tat4xbErpsConfigInstanceCommand OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:None 1:Manual Switch 2:Forced Switch 3:Clear Please set InstancePort first. " ::= { sm24tat4xbERPSConfigInstanceEntry 12 } sm24tat4xbErpsConfigInstancePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:None 1:Port0 2:Port1 Please set InstanceCommand after specify InstancePort. " ::= { sm24tat4xbERPSConfigInstanceEntry 13 } sm24tat4xbErpsStatusProtectionState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ERPS state according to State Transition Tables in G.8032. " ::= { sm24tat4xbERPSConfigInstanceEntry 14 } sm24tat4xbErpsStatusPort0 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "OK: State of East port is ok SF: State of East port is Signal Fail " ::= { sm24tat4xbERPSConfigInstanceEntry 15 } sm24tat4xbErpsStatusPort1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "OK: State of West port is ok SF: State of West port is Signal Fail " ::= { sm24tat4xbERPSConfigInstanceEntry 16 } sm24tat4xbErpsStatusTransmitAPS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitted APS according to State Transition Tables in G.8032. " ::= { sm24tat4xbERPSConfigInstanceEntry 17 } sm24tat4xbErpsStatusPort0ReceiveAPS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The received APS on Port 0 according to State Transition Tables in G.8032. " ::= { sm24tat4xbERPSConfigInstanceEntry 18 } sm24tat4xbErpsStatusPort1ReceiveAPS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The received APS on Port 1 according to State Transition Tables in G.8032. " ::= { sm24tat4xbERPSConfigInstanceEntry 19 } sm24tat4xbErpsStatusWTRRemaining OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Remaining WTR timeout in milliseconds. " ::= { sm24tat4xbERPSConfigInstanceEntry 20 } sm24tat4xbErpsStatusRPLUnblocked OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "APS is received on the working flow. " ::= { sm24tat4xbERPSConfigInstanceEntry 21 } sm24tat4xbErpsStatusNoAPSReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RAPS PDU is not received from the other end. " ::= { sm24tat4xbERPSConfigInstanceEntry 22 } sm24tat4xbErpsStatusPort0BlockStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Block status for Port 0 (Both traffic and R-APS block status). R-APS channel is never blocked on sub-rings without virtual channel. " ::= { sm24tat4xbERPSConfigInstanceEntry 23 } sm24tat4xbErpsStatusPort1BlockStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Block status for Port 1 (Both traffic and R-APS block status). R-APS channel is never blocked on sub-rings without virtual channel. " ::= { sm24tat4xbERPSConfigInstanceEntry 24 } sm24tat4xbErpsStatusFOPAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Failure of Protocol Defect(FOP) status: FOP is not detected FOP is detected " ::= { sm24tat4xbERPSConfigInstanceEntry 25 } sm24tat4xbErpsConfigInstanceVLANConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBErpsConfigInstanceVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ERPS VLANConfig." ::= { sm24tat4xbERPS 4 } sm24tat4xbErpsConfigInstanceVLANConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBErpsConfigInstanceVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sm24tat4xbErpsConfigInstanceVLANConfigIndex } ::= { sm24tat4xbErpsConfigInstanceVLANConfigTable 1 } SM24TAT4XBErpsConfigInstanceVLANConfigEntry ::= SEQUENCE { sm24tat4xbErpsConfigInstanceVLANConfigIndex Integer32, sm24tat4xbErpsConfigInstanceVLANConfigVLANID Integer32, sm24tat4xbErpsConfigInstanceVLANConfigRowStatus RowStatus } sm24tat4xbErpsConfigInstanceVLANConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbErpsConfigInstanceVLANConfigEntry 1 } sm24tat4xbErpsConfigInstanceVLANConfigVLANID OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "ERPS VLAN Config ID. Range:1-4095." ::= {sm24tat4xbErpsConfigInstanceVLANConfigEntry 2 } sm24tat4xbErpsConfigInstanceVLANConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "ERPS VLAN Config Row Status." ::= {sm24tat4xbErpsConfigInstanceVLANConfigEntry 3 } -- ======================================================================================================================= sm24tat4xbVLANTranslation OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 25 } sm24tat4xbVLANTranslationPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANTranslationPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of VLANTranslationPort." ::= { sm24tat4xbVLANTranslation 1 } sm24tat4xbVLANTranslationPortEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANTranslationPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the VLANTranslationPort table." INDEX { sm24tat4xbVLANTranslationPortIndex } ::= { sm24tat4xbVLANTranslationPortTable 1 } SM24TAT4XBVLANTranslationPortEntry ::= SEQUENCE { sm24tat4xbVLANTranslationPortIndex Integer32, sm24tat4xbVLANTranslationPortDefault Integer32, sm24tat4xbVLANTranslationPortGroupID Integer32 } sm24tat4xbVLANTranslationPortIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLANTranslationPort index." ::= {sm24tat4xbVLANTranslationPortEntry 1 } sm24tat4xbVLANTranslationPortDefault OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Set the switch port to use the default VLAN Translation Group. 1:set 0:not set" ::= {sm24tat4xbVLANTranslationPortEntry 2 } sm24tat4xbVLANTranslationPortGroupID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The VLAN Translation mappings are organized into Groups, identified by the Group ID." ::= {sm24tat4xbVLANTranslationPortEntry 3 } sm24tat4xbVLANTranslationMappingTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANTranslationMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of VLANTranslationMapping." ::= { sm24tat4xbVLANTranslation 2 } sm24tat4xbVLANTranslationMappingEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANTranslationMappingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the VLANTranslationMapping table." INDEX { sm24tat4xbVLANTranslationMappingIndex } ::= { sm24tat4xbVLANTranslationMappingTable 1 } SM24TAT4XBVLANTranslationMappingEntry ::= SEQUENCE { sm24tat4xbVLANTranslationMappingIndex Integer32, sm24tat4xbVLANTranslationMappingGroupID Integer32, sm24tat4xbVLANTranslationMappingVID Integer32, sm24tat4xbVLANTranslationMappingTVID Integer32, sm24tat4xbVLANTranslationMappingRowStatus RowStatus } sm24tat4xbVLANTranslationMappingIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLANTranslationMapping index." ::= {sm24tat4xbVLANTranslationMappingEntry 1 } sm24tat4xbVLANTranslationMappingGroupID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN Translation mappings are organized into Groups, identified by the Group ID." ::= {sm24tat4xbVLANTranslationMappingEntry 2 } sm24tat4xbVLANTranslationMappingVID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Range:1-4095" ::= {sm24tat4xbVLANTranslationMappingEntry 3 } sm24tat4xbVLANTranslationMappingTVID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Range:1-4095" ::= {sm24tat4xbVLANTranslationMappingEntry 4 } sm24tat4xbVLANTranslationMappingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "VLANTranslationMapping Row Status." ::= {sm24tat4xbVLANTranslationMappingEntry 5 } -- ======================================================================================================== sm24tat4xbMEP OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 26 } sm24tat4xbMEPTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMEPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of MEP." ::= { sm24tat4xbMEP 1 } sm24tat4xbMEPEntry OBJECT-TYPE SYNTAX SM24TAT4XBMEPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the MEP table." INDEX { sm24tat4xbMEPIndex } ::= { sm24tat4xbMEPTable 1 } SM24TAT4XBMEPEntry ::= SEQUENCE { sm24tat4xbMEPIndex Integer32, sm24tat4xbMepInstance Integer32, sm24tat4xbMepDomain Integer32, sm24tat4xbMepMode Integer32, sm24tat4xbMepDirection Integer32, sm24tat4xbMepResidencePort Integer32, sm24tat4xbMepLevel Integer32, sm24tat4xbMepFlowInstance Integer32, sm24tat4xbMepTaggedVID Integer32, sm24tat4xbMepEPSInstance DisplayString, sm24tat4xbMepThisMAC DisplayString, sm24tat4xbMepAlarm DisplayString, sm24tat4xbMepRowStatus RowStatus } sm24tat4xbMEPIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "MEP Table index." ::= {sm24tat4xbMEPEntry 1 } sm24tat4xbMepInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 2 } sm24tat4xbMepDomain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 3 } sm24tat4xbMepMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 4 } sm24tat4xbMepDirection OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 5 } sm24tat4xbMepResidencePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 6 } sm24tat4xbMepLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 7 } sm24tat4xbMepFlowInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 8 } sm24tat4xbMepTaggedVID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 9 } sm24tat4xbMepEPSInstance OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 10 } sm24tat4xbMepThisMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 11 } sm24tat4xbMepAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMEPEntry 12 } sm24tat4xbMepRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "MEP Row Status." ::= {sm24tat4xbMEPEntry 13 } sm24tat4xbMepInstanceID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify MEP Instance ID for the following item and table uesd." ::= {sm24tat4xbMEP 2 } sm24tat4xbMepInstanceConfEntry OBJECT IDENTIFIER ::= { sm24tat4xbMEP 3 } sm24tat4xbMepInstanceConfLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 2 } sm24tat4xbMepInstanceConfFormat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 3 } sm24tat4xbMepInstanceConfDomainName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 4 } sm24tat4xbMepInstanceConfMEGid OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 5 } sm24tat4xbMepInstanceConfMEPid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 6 } sm24tat4xbMepInstanceConfTaggedVID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 7 } sm24tat4xbMepInstanceConfSyslog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 8 } sm24tat4xbMepInstanceConfcLevel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 9 } sm24tat4xbMepInstanceConfcMEG OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 10 } sm24tat4xbMepInstanceConfcMEP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 11 } sm24tat4xbMepInstanceConfcAIS OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 12 } sm24tat4xbMepInstanceConfcLCK OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 13 } sm24tat4xbMepInstanceConfcLoop OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 14 } sm24tat4xbMepInstanceConfcConfig OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 15 } sm24tat4xbMepInstanceConfcDEG OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 16 } sm24tat4xbMepInstanceConfcSSF OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 17 } sm24tat4xbMepInstanceConfaBLK OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 18 } sm24tat4xbMepInstanceConfaTSD OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 19 } sm24tat4xbMepInstanceConfaTSF OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbMepInstanceConfEntry 20 } sm24tat4xbPeerMepConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPeerMepConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of MEP." ::= { sm24tat4xbMEP 4 } sm24tat4xbPeerMepConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBPeerMepConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sm24tat4xbPeerMepConfIndex } ::= { sm24tat4xbPeerMepConfTable 1 } SM24TAT4XBPeerMepConfEntry ::= SEQUENCE { sm24tat4xbPeerMepConfIndex Integer32, sm24tat4xbPeerMepConfPeerMEPID Integer32, sm24tat4xbPeerMepConfUnicastPeerMAC DisplayString, sm24tat4xbPeerMepConfcLOC DisplayString, sm24tat4xbPeerMepConfcRDI DisplayString, sm24tat4xbPeerMepConfcPeriod DisplayString, sm24tat4xbPeerMepConfcPriority DisplayString, sm24tat4xbPeerMepConfRowStatus RowStatus } sm24tat4xbPeerMepConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbPeerMepConfEntry 1 } sm24tat4xbPeerMepConfPeerMEPID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Peer MEP ID" ::= {sm24tat4xbPeerMepConfEntry 2 } sm24tat4xbPeerMepConfUnicastPeerMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbPeerMepConfEntry 3 } sm24tat4xbPeerMepConfcLOC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbPeerMepConfEntry 4 } sm24tat4xbPeerMepConfcRDI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbPeerMepConfEntry 5 } sm24tat4xbPeerMepConfcPeriod OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbPeerMepConfEntry 6 } sm24tat4xbPeerMepConfcPriority OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= {sm24tat4xbPeerMepConfEntry 7 } sm24tat4xbPeerMepConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Peer Mep Conf Row Status." ::= {sm24tat4xbPeerMepConfEntry 8 } sm24tat4xbFunctionalConf OBJECT IDENTIFIER ::= { sm24tat4xbMEP 5 } sm24tat4xbFunctionalConfContinuityCheckEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= {sm24tat4xbFunctionalConf 2 } sm24tat4xbFunctionalConfContinuityCheckPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-7" ::= {sm24tat4xbFunctionalConf 3 } sm24tat4xbFunctionalConfContinuityCheckFrameRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:1-7 1: 300 f/sec 2: 100 f/sec 3: 10 f/sec 4: 1 f/sec 5: 6 f/min 6: 1 f/min 7: 6 f/hour" ::= {sm24tat4xbFunctionalConf 4 } sm24tat4xbFunctionalConfContinuityCheckTLV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= {sm24tat4xbFunctionalConf 5 } sm24tat4xbFunctionalConfAPSProtocolEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= {sm24tat4xbFunctionalConf 6 } sm24tat4xbFunctionalConfAPSProtocolPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-7" ::= {sm24tat4xbFunctionalConf 7 } sm24tat4xbFunctionalConfAPSProtocolCast OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0: Unicast destination address 1: Multicast destination address" ::= {sm24tat4xbFunctionalConf 8 } sm24tat4xbFunctionalConfAPSProtocolType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "1: Linear protection APS 2: Ring protection APS" ::= {sm24tat4xbFunctionalConf 9 } sm24tat4xbFunctionalConfAPSProtocolLastOctet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-255" ::= {sm24tat4xbFunctionalConf 10 } sm24tat4xbTLVConf OBJECT IDENTIFIER ::= { sm24tat4xbMEP 6 } sm24tat4xbTLVConfOUIFirst OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-255" ::= {sm24tat4xbTLVConf 2 } sm24tat4xbTLVConfOUISecond OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-255" ::= {sm24tat4xbTLVConf 3 } sm24tat4xbTLVConfOUIThird OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-255" ::= {sm24tat4xbTLVConf 4 } sm24tat4xbTLVConfSubType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-255" ::= {sm24tat4xbTLVConf 5 } sm24tat4xbTLVConfValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-255" ::= {sm24tat4xbTLVConf 6 } sm24tat4xbTLVConfStateTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBTLVConfStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "TLV Conf State Table" ::= { sm24tat4xbMEP 7 } sm24tat4xbTLVConfStateEntry OBJECT-TYPE SYNTAX SM24TAT4XBTLVConfStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "TLV Conf State Entry" INDEX { sm24tat4xbTLVConfStateIndex } ::= { sm24tat4xbTLVConfStateTable 1 } SM24TAT4XBTLVConfStateEntry ::= SEQUENCE { sm24tat4xbTLVConfStateIndex Integer32, sm24tat4xbTLVConfStatePeerMEPID Integer32, sm24tat4xbTLVConfStateCCOrganizationSpecificOUIFirst Integer32, sm24tat4xbTLVConfStateCCOrganizationSpecificOUISecond Integer32, sm24tat4xbTLVConfStateCCOrganizationSpecificOUIThird Integer32, sm24tat4xbTLVConfStateCCOrganizationSpecificSubType Integer32, sm24tat4xbTLVConfStateCCOrganizationSpecificValue Integer32, sm24tat4xbTLVConfStateCCOrganizationSpecificLastRX DisplayString, sm24tat4xbTLVConfStateCCPortStatusValue Integer32, sm24tat4xbTLVConfStateCCPortStatusLastRX DisplayString, sm24tat4xbTLVConfStateCCInterfaceStatusValue Integer32, sm24tat4xbTLVConfStateCCInterfaceStatusLastRX DisplayString } sm24tat4xbTLVConfStateIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbTLVConfStateEntry 1 } sm24tat4xbTLVConfStatePeerMEPID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Peer MEP ID" ::= { sm24tat4xbTLVConfStateEntry 2 } sm24tat4xbTLVConfStateCCOrganizationSpecificOUIFirst OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received first value in the OUI field." ::= { sm24tat4xbTLVConfStateEntry 3 } sm24tat4xbTLVConfStateCCOrganizationSpecificOUISecond OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received second value in the OS TLV OUI field." ::= { sm24tat4xbTLVConfStateEntry 4 } sm24tat4xbTLVConfStateCCOrganizationSpecificOUIThird OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received third value in the OS TLV OUI field." ::= { sm24tat4xbTLVConfStateEntry 5 } sm24tat4xbTLVConfStateCCOrganizationSpecificSubType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received value in the OS TLV Sub-Type field." ::= { sm24tat4xbTLVConfStateEntry 6 } sm24tat4xbTLVConfStateCCOrganizationSpecificValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received value in the OS TLV Value field." ::= { sm24tat4xbTLVConfStateEntry 7 } sm24tat4xbTLVConfStateCCOrganizationSpecificLastRX OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "OS TLV was received in the last received CCM PDU." ::= { sm24tat4xbTLVConfStateEntry 8 } sm24tat4xbTLVConfStateCCPortStatusValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received value in the PS TLV Value field." ::= { sm24tat4xbTLVConfStateEntry 9 } sm24tat4xbTLVConfStateCCPortStatusLastRX OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PS TLV was received in the last received CCM PDU." ::= { sm24tat4xbTLVConfStateEntry 10 } sm24tat4xbTLVConfStateCCInterfaceStatusValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The last received value in the IS TLV Value field." ::= { sm24tat4xbTLVConfStateEntry 11 } sm24tat4xbTLVConfStateCCInterfaceStatusLastRX OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IS TLV was received in the last received CCM PDU." ::= { sm24tat4xbTLVConfStateEntry 12 } sm24tat4xbLinkStateTracking OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbMEP 8 } sm24tat4xbFaultManagement OBJECT IDENTIFIER ::= { sm24tat4xbMEP 9 } sm24tat4xbFaultMgmtLoopBackConfEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbFaultManagement 2 } sm24tat4xbFaultMgmtLoopBackConfDEI OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbFaultManagement 3 } sm24tat4xbFaultMgmtLoopBackConfPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-7" ::= { sm24tat4xbFaultManagement 4 } sm24tat4xbFaultMgmtLoopBackConfCast OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Unicast destination address 1:Multicast destination address" ::= { sm24tat4xbFaultManagement 5 } sm24tat4xbFaultMgmtLoopBackConfPeerMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is only used if the 'Unicast MAC' is configured to all zero. The LBM unicast MAC will be taken from the 'Unicast Peer MAC' configuration of this peer." ::= { sm24tat4xbFaultManagement 6 } sm24tat4xbFaultMgmtLoopBackConfUnicastMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This is only used if NOT configured to all zero. This will be used as the LBM PDU unicast MAC. This is the only way to configure Loop Back to-wards a MIP. " ::= { sm24tat4xbFaultManagement 7 } sm24tat4xbFaultMgmtLoopBackConfToSend OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of LBM PDU to send in one loop test. The value 0 indicate infinite transmission (test behaviour). This is HW based LBM/LBR and Requires VOE." ::= { sm24tat4xbFaultManagement 8 } sm24tat4xbFaultMgmtLoopBackConfSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The LBM frame size." ::= { sm24tat4xbFaultManagement 9 } sm24tat4xbFaultMgmtLoopBackConfInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The interval between transmitting LBM PDU." ::= { sm24tat4xbFaultManagement 10 } sm24tat4xbFaultManagementState OBJECT IDENTIFIER ::= { sm24tat4xbMEP 10 } sm24tat4xbFaultMgmtStateTransactionID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The transaction id of the first LBM transmitted. For each LBM transmitted the transaction id in the PDU is incremented." ::= { sm24tat4xbFaultManagementState 1 } sm24tat4xbFaultMgmtStateTransmitted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of LBM PDU transmitted." ::= { sm24tat4xbFaultManagementState 2 } sm24tat4xbFaultMgmtStateTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBFaultMgmtStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbFaultManagementState 3 } sm24tat4xbFaultMgmtStateEntry OBJECT-TYPE SYNTAX SM24TAT4XBFaultMgmtStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbFaultMgmtStateIndex } ::= { sm24tat4xbFaultMgmtStateTable 1 } SM24TAT4XBFaultMgmtStateEntry ::= SEQUENCE { sm24tat4xbFaultMgmtStateIndex Integer32, sm24tat4xbFaultMgmtStateReplyMAC DisplayString, sm24tat4xbFaultMgmtStateReceived Integer32, sm24tat4xbFaultMgmtStateOutOfOrder Integer32 } sm24tat4xbFaultMgmtStateIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbFaultMgmtStateEntry 1 } sm24tat4xbFaultMgmtStateReplyMAC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC of the replying MEP/MIP. In case of multi-cast LBM, replies can be received from all peer MEP in the group. This MAC is not shown in case of 'To Send' == 0." ::= { sm24tat4xbFaultMgmtStateEntry 2 } sm24tat4xbFaultMgmtStateReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of LBR PDU received from this 'Reply MAC'." ::= { sm24tat4xbFaultMgmtStateEntry 3 } sm24tat4xbFaultMgmtStateOutOfOrder OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LBR PDU received from this 'Reply MAC' with incorrect 'Transaction ID'." ::= { sm24tat4xbFaultMgmtStateEntry 4 } sm24tat4xbFaultMgmtTestSignal OBJECT IDENTIFIER ::= { sm24tat4xbMEP 11 } sm24tat4xbFaultMgmtTestSignalTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Test Signal based on transmitting TST PDU can be enabled/disabled. 0:disable 1:enable" ::= { sm24tat4xbFaultMgmtTestSignal 2 } sm24tat4xbFaultMgmtTestSignalRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Test Signal based on transmitting TST PDU can be enabled/disabled. 0:disable 1:enable" ::= { sm24tat4xbFaultMgmtTestSignal 3 } sm24tat4xbFaultMgmtTestSignalDEI OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The DEI to be inserted as PCP bits in TAG (if any). 0:disable 1:enable" ::= { sm24tat4xbFaultMgmtTestSignal 4 } sm24tat4xbFaultMgmtTestSignalPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The priority to be inserted as PCP bits in TAG (if any). Range:0-7" ::= { sm24tat4xbFaultMgmtTestSignal 5 } sm24tat4xbFaultMgmtTestSignalPeerMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The TST frame destination MAC will be taken from the 'Unicast Peer MAC' configuration of this peer." ::= { sm24tat4xbFaultMgmtTestSignal 6 } sm24tat4xbFaultMgmtTestSignalRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The TST frame transmission bit rate - in Mega bits pr. second. Limit is 400 Mbps. This is the bit rate of a standard frame without any encapsulation. If 1 Mbps rate is selected in a EVC MEP, the added tag will give a higher bitrate on the wire." ::= { sm24tat4xbFaultMgmtTestSignal 7 } sm24tat4xbFaultMgmtTestSignalSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The TST frame size. This is entered as the wanted size (in bytes) of a un-tagged frame containing TST OAM PDU - including CRC (four bytes)." ::= { sm24tat4xbFaultMgmtTestSignal 8 } sm24tat4xbFaultMgmtTestSignalPattern OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The 'empty' TST PDU has the size of 12 bytes. In order to achieve the configured frame size a data TLV will be added with a pattern. 0:All Zero 1:All One 2:10101010" ::= { sm24tat4xbFaultMgmtTestSignal 9 } sm24tat4xbFaultMgmtTestSignalSequenceNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:disable 1:enable" ::= { sm24tat4xbFaultMgmtTestSignal 10 } sm24tat4xbFaultMgmtTestSignalState OBJECT IDENTIFIER ::= { sm24tat4xbMEP 12 } sm24tat4xbFaultMgmtTestSignalStateTXFrameCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted TST frames since last 'Clear'." ::= { sm24tat4xbFaultMgmtTestSignalState 2 } sm24tat4xbFaultMgmtTestSignalStateRXFrameCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received TST frames since last 'Clear'." ::= { sm24tat4xbFaultMgmtTestSignalState 3 } sm24tat4xbFaultMgmtTestSignalStateRXRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current received TST frame bit rate in Kbps. This is calculated on a 1 s. basis, starting when first TST frame is received after 'Clear'. The frame size used for this calculation is the first received after 'Clear'" ::= { sm24tat4xbFaultMgmtTestSignalState 4 } sm24tat4xbFaultMgmtTestSignalStateTestTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds passed since first TST frame received after last 'Clear'." ::= { sm24tat4xbFaultMgmtTestSignalState 5 } sm24tat4xbFaultMgmtTestSignalStateClear OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This will clear all Test Signal State. Transmission of TST frame will be restarted. Calculation of 'Rx frame count', 'RX rate' and 'Test time' will be started when receiving first TST frame." ::= { sm24tat4xbFaultMgmtTestSignalState 6 } sm24tat4xbFaultMgmtClientConfigFlow OBJECT IDENTIFIER ::= { sm24tat4xbMEP 13 } sm24tat4xbFaultMgmtClientConfigFlowTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBFaultMgmtClientConfigFlowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbFaultMgmtClientConfigFlow 1 } sm24tat4xbFaultMgmtClientConfigFlowEntry OBJECT-TYPE SYNTAX SM24TAT4XBFaultMgmtClientConfigFlowEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbFaultMgmtClientConfigFlowIndex } ::= { sm24tat4xbFaultMgmtClientConfigFlowTable 1 } SM24TAT4XBFaultMgmtClientConfigFlowEntry ::= SEQUENCE { sm24tat4xbFaultMgmtClientConfigFlowIndex Integer32, sm24tat4xbFaultMgmtClientConfigFlowDomain Integer32, sm24tat4xbFaultMgmtClientConfigFlowInstance Integer32, sm24tat4xbFaultMgmtClientConfigFlowLevel Integer32, sm24tat4xbFaultMgmtClientConfigFlowAISprio Integer32, sm24tat4xbFaultMgmtClientConfigFlowLCKprio Integer32, sm24tat4xbFaultMgmtClientConfigFlowRowStatus RowStatus } sm24tat4xbFaultMgmtClientConfigFlowIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbFaultMgmtClientConfigFlowEntry 1 } sm24tat4xbFaultMgmtClientConfigFlowDomain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The domain of the client layer flow. Ranfew:0-6 0:Port 1:EVC 2:VLAN 3:MPLS_LINK 4:MPLS_TUNNEL 5:MPLS_PW 6:MPLS_LSP" ::= { sm24tat4xbFaultMgmtClientConfigFlowEntry 2 } sm24tat4xbFaultMgmtClientConfigFlowInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Client layer flow instance numbers." ::= { sm24tat4xbFaultMgmtClientConfigFlowEntry 3 } sm24tat4xbFaultMgmtClientConfigFlowLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Client layer level - AIS and LCK PDU transmitted in this client layer flow will be on this level." ::= { sm24tat4xbFaultMgmtClientConfigFlowEntry 4 } sm24tat4xbFaultMgmtClientConfigFlowAISprio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The priority to be used when transmitting AIS in each client flow. Priority resulting in highest possible PCP can be selected. Range:0-7. 255 indicate highest possible is requested" ::= { sm24tat4xbFaultMgmtClientConfigFlowEntry 5 } sm24tat4xbFaultMgmtClientConfigFlowLCKprio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The priority to be used when transmitting LCK in each client flow. Priority resulting in highest possible PCP can be selected. Range:0-7. 255 indicate highest possible is requested" ::= { sm24tat4xbFaultMgmtClientConfigFlowEntry 6 } sm24tat4xbFaultMgmtClientConfigFlowRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "FaultMgmtClientConfigFlow Row Status." ::= {sm24tat4xbFaultMgmtClientConfigFlowEntry 7 } sm24tat4xbFaultMgmtAISLOCK OBJECT IDENTIFIER ::= { sm24tat4xbMEP 14 } sm24tat4xbFaultMgmtAISEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Insertion of AIS signal (AIS PDU transmission) in client layer flows, can be enable/disabled. 0:disable 1:enable" ::= { sm24tat4xbFaultMgmtAISLOCK 2 } sm24tat4xbFaultMgmtAISFrameRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Selecting the frame rate of AIS PDU. This is the inverse of transmission period as described in Y.1731. 1: 300 frames per second 2: 100 frames per second 3: 10 frames per second 4: 1 frames per second 5: 6 frames per minute 6: 1 frames per minute 7: 6 frames per hour" ::= { sm24tat4xbFaultMgmtAISLOCK 3 } sm24tat4xbFaultMgmtAISProtection OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Selecting this means that the first 3 AIS PDU is transmitted as fast as possible - in case of using this for protection in the end point. 0:disable 1:enable" ::= { sm24tat4xbFaultMgmtAISLOCK 4 } sm24tat4xbFaultMgmtLOCKEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Insertion of LOCK signal (LCK PDU transmission) in client layer flows, can be enable/disabled. 0:disable 1:enable" ::= { sm24tat4xbFaultMgmtAISLOCK 5 } sm24tat4xbFaultMgmtLOCKFrameRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Selecting the frame rate of LCK PDU. This is the inverse of transmission period as described in Y.1731. 1: 300 frames per second 2: 100 frames per second 3: 10 frames per second 4: 1 frames per second 5: 6 frames per minute 6: 1 frames per minute 7: 6 frames per hour" ::= { sm24tat4xbFaultMgmtAISLOCK 6 } sm24tat4xbPerformanceMonitor OBJECT IDENTIFIER ::= { sm24tat4xbMEP 15 } sm24tat4xbDataSetEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " When enabled this MEP instance will contribute to the 'PM Data Set' gathered by the PM Session. 0:disable 1:enable" ::= { sm24tat4xbPerformanceMonitor 2 } sm24tat4xbLossMeasureEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Loss Measurement based on transmitting/receiving CCM or LMM/LMR PDU can be enabled/disabled - see 'Ended'. This is only valid with one Peer MEP configured. 0:disable 1:enable" ::= { sm24tat4xbPerformanceMonitor 3 } sm24tat4xbLossMeasurePriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The priority to be inserted as PCP bits in TAG (if any). In case of enable of Continuity Check and Loss Measurement both implemented on SW based CCM, 'Priority' has to be the same. range:0-7" ::= { sm24tat4xbPerformanceMonitor 4 } sm24tat4xbLossMeasureFrameRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " 1: 300 frames per second 2: 100 frames per second 3: 10 frames per second 4: 1 frames per second 5: 6 frames per minute 6: 1 frames per minute 7: 6 frames per hour" ::= { sm24tat4xbPerformanceMonitor 5 } sm24tat4xbLossMeasureCast OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " 0: Unicast destination address 1: Multicast destination address " ::= { sm24tat4xbPerformanceMonitor 6 } sm24tat4xbLossMeasureEnded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " 0: Single ended LM based on LMM/LMR or DM based on DMM/DMR 1: Dual ended LM based on CCM or DM based on 1DM " ::= { sm24tat4xbPerformanceMonitor 7 } sm24tat4xbLossMeasureFLRInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This is the interval in seconds where the Frame Loss Ratio is calculated. " ::= { sm24tat4xbPerformanceMonitor 8 } sm24tat4xbLossMeasureLossThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Far end loss threshold count is incremented if a loss measurement is above this threshold. " ::= { sm24tat4xbPerformanceMonitor 9 } sm24tat4xbLossMeasureStateTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitor 10 } sm24tat4xbLossMeasureStateRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitor 11 } sm24tat4xbLossMeasureStateNearEndLossCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated near end frame loss count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 12 } sm24tat4xbLossMeasureStateFarEndLossCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated far end frame loss count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 13 } sm24tat4xbLossMeasureStateNearEndLossRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The near end frame loss ratio calculated based on the near end frame loss count and far end frame transmitted - in the latest 'FLR Interval'. The result is given in percent. " ::= { sm24tat4xbPerformanceMonitor 14 } sm24tat4xbLossMeasureStateFarEndLossRatio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The far end frame loss ratio calculated based on the far end frame loss count and near end frame transmitted - in the latest 'FLR Interval'. The result is given in percent. " ::= { sm24tat4xbPerformanceMonitor 15 } sm24tat4xbLossMeasureStateClear OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Set of this check and save will clear the accumulated counters and restart ratio calculation. " ::= { sm24tat4xbPerformanceMonitor 16 } sm24tat4xbLossMeasureAvailabilityEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable of loss measurement availability. 0:disable 1:enable " ::= { sm24tat4xbPerformanceMonitor 17 } sm24tat4xbLossMeasureAvailabilityInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Availability interval - number of measurements with same availability in order to change availability state. " ::= { sm24tat4xbPerformanceMonitor 18 } sm24tat4xbLossMeasureAvailabilityFLRThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Availability frame loss ratio threshold in per mille. " ::= { sm24tat4xbPerformanceMonitor 19 } sm24tat4xbLossMeasureAvailabilityMaintenance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable of loss measurement availability maintenance. " ::= { sm24tat4xbPerformanceMonitor 20 } sm24tat4xbLossMeasureAvailabilityStateNearAvailabilityCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Near end availability count. " ::= { sm24tat4xbPerformanceMonitor 21 } sm24tat4xbLossMeasureAvailabilityStateFarAvailabilityCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Far end availability count. " ::= { sm24tat4xbPerformanceMonitor 22 } sm24tat4xbLossMeasureAvailStateNearUnavailabilityCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Near end unavailability count. " ::= { sm24tat4xbPerformanceMonitor 23 } sm24tat4xbLossMeasureAvailabilityStateFarUnavailabilityCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Far end unavailability count. " ::= { sm24tat4xbPerformanceMonitor 24 } sm24tat4xbLossMeasureAvailabilityStateNearState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Near end availability state. " ::= { sm24tat4xbPerformanceMonitor 25 } sm24tat4xbLossMeasureAvailabilityStateFarState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Far end availability state. " ::= { sm24tat4xbPerformanceMonitor 26 } sm24tat4xbLossMeasureHighLossIntervalEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable of loss measurement high loss interval. 0:disable 1:enable " ::= { sm24tat4xbPerformanceMonitor 27 } sm24tat4xbLossMeasureHighLossIntervalFLRThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High Loss Interval frame loss ratio threshold in per mille. " ::= { sm24tat4xbPerformanceMonitor 28 } sm24tat4xbLossMeasureHighLossIntervalConsecutiveInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "High Loss Interval consecutive interval (number of measurements). " ::= { sm24tat4xbPerformanceMonitor 29 } sm24tat4xbLossMeasureHighLossIntervalStateNearCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Near end high loss interval count (number of measurements where availability state is available and FLR is above high loss interval FLR threshold. " ::= { sm24tat4xbPerformanceMonitor 30 } sm24tat4xbLossMeasureHighLossIntervalStateFarCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Far end high loss interval count (number of measurements where availability state is available and FLR is above high loss interval FLR threshold. " ::= { sm24tat4xbPerformanceMonitor 31 } sm24tat4xbLossMeasureIntervalStateNearConsecutiveCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Near end high loss interval consecutive count. " ::= { sm24tat4xbPerformanceMonitor 32 } sm24tat4xbLossMeasureIntervalStateFarConsecutiveCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Far end high loss interval consecutive count. " ::= { sm24tat4xbPerformanceMonitor 33 } sm24tat4xbLossMeasureSignalDegradeEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable of loss measurement signal degrade. 0:disable 1:enable " ::= { sm24tat4xbPerformanceMonitor 34 } sm24tat4xbLossMeasureSignalDegradeTXMinimum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum number of frames that must be transmitted in a measurement before frame loss ratio is tested against loss ratio threshold. " ::= { sm24tat4xbPerformanceMonitor 35 } sm24tat4xbLossMeasureSignalDegradeFLRThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Signal Degraded frame loss ratio threshold in per mille. " ::= { sm24tat4xbPerformanceMonitor 36 } sm24tat4xbLossMeasureSignalDegradeBadThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of consecutive bad interval measurements required to set degrade state. " ::= { sm24tat4xbPerformanceMonitor 37 } sm24tat4xbLossMeasureSignalDegradeGoodThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Number of consecutive good interval measurements required to clear degrade state. " ::= { sm24tat4xbPerformanceMonitor 38 } sm24tat4xbDelayMeasureEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Delay Measurement based on transmitting 1DM/DMM PDU can be enabled/disabled. Delay Measurement based on receiving and handling 1DM/DMR PDU is always enabled. 0:disable 1:enable " ::= { sm24tat4xbPerformanceMonitor 39 } sm24tat4xbDelayMeasurePriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The priority to be inserted as PCP bits in TAG (if any). Range:0-7 " ::= { sm24tat4xbPerformanceMonitor 40 } sm24tat4xbDelayMeasureCast OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Selection of 1DM/DMM PDU transmitted unicast or multicast. The unicast MAC will be configured through 'Peer MEP'. 0: Unicast destination address 1: Multicast destination address " ::= { sm24tat4xbPerformanceMonitor 41 } sm24tat4xbDelayMeasurePeerMEP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is only used if the 'Cast' is configured to Uni. The 1DM/DMR unicast MAC will be taken from the 'Unicast Peer MAC' configuration of this peer. " ::= { sm24tat4xbPerformanceMonitor 42 } sm24tat4xbDelayMeasureEnded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:One-Way: One-Way Delay Measurement implemented on 1DM. 1:Two-Way: Two-Way Delay Measurement implemented on DMM/DMR. " ::= { sm24tat4xbPerformanceMonitor 43 } sm24tat4xbDelayMeasureTxMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Standardize: Y.1731 standardize way to transmit 1DM/DMR. 1:Proprietary: Vitesse proprietary way with follow-up packets to transmit 1DM/DMR. " ::= { sm24tat4xbPerformanceMonitor 44 } sm24tat4xbDelayMeasureCalc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is only used if the 'Way' is configured to Two-way. 0:Round trip: The frame delay calculated by the transmitting and receiving timestamps of initiators. Frame Delay = RxTimeb-TxTimeStampf 1:Flow: The frame delay calculated by the transmitting and receiving timestamps of initiators and remotes. Frame Delay = (RxTimeb-TxTimeStampf)-(TxTimeStampb-RxTimeStampf) " ::= { sm24tat4xbPerformanceMonitor 45 } sm24tat4xbDelayMeasureGap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The gap between transmitting 1DM/DMM PDU in 10ms. The range is 10 to 65535. " ::= { sm24tat4xbPerformanceMonitor 46 } sm24tat4xbDelayMeasureCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of last records to calculate. The range is 10 to 2000. " ::= { sm24tat4xbPerformanceMonitor 47 } sm24tat4xbDelayMeasureUnit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time resolution. 0:us 1:ns " ::= { sm24tat4xbPerformanceMonitor 48 } sm24tat4xbDelayMeasureD2forD1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable to use DMM/DMR packet to calculate one-way DM. 0:disable 1:enable " ::= { sm24tat4xbPerformanceMonitor 49 } sm24tat4xbDelayMeasureCounterOverflowAction OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The action to counter when overflow happens. 0: Keep:When internal total delay counter overflow, DM is disabled automatically 1: Reset:When internal total delay counter overflow, counter is reset and DM continues running " ::= { sm24tat4xbPerformanceMonitor 50 } sm24tat4xbDelayMeasureStateOnewayTx OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated transmit count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 51 } sm24tat4xbDelayMeasureStateOnewayRx OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 52 } sm24tat4xbDelayMeasureStateOnewayRxTimeout OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive timeout count for two-way only - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 53 } sm24tat4xbDelayMeasureStateOnewayRxError OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive error count - since last 'clear'. This is counting if the frame delay is larger than 1 second or if far end residence time is larger than the round trip time. " ::= { sm24tat4xbPerformanceMonitor 54 } sm24tat4xbDelayMeasureStateOnewayAvDelayTot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 55 } sm24tat4xbDelayMeasureStateOnewayAvDelaylastN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 56 } sm24tat4xbDelayMeasureStateOnewayDelayMin OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 57 } sm24tat4xbDelayMeasureStateOnewayDelayMax OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 58 } sm24tat4xbDelayMeasureStateOnewayAvDelayVarTot OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 59 } sm24tat4xbDelayMeasureStateOnewayAvDelayVarlastN OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay variation of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 60 } sm24tat4xbDelayMeasureStateOnewayDelayVarMin OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 61 } sm24tat4xbDelayMeasureStateOnewayDelayVarMax OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 62 } sm24tat4xbDelayMeasureStateOnewayOverflow OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The number of counter overflow - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 63 } sm24tat4xbDelayMeasureStateFtoNTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated transmit count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 64 } sm24tat4xbDelayMeasureStateFtoNRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 65 } sm24tat4xbDelayMeasureStateFtoNRxTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive timeout count for two-way only - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 66 } sm24tat4xbDelayMeasureStateFtoNRxError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive error count - since last 'clear'. This is counting if the frame delay is larger than 1 second or if far end residence time is larger than the round trip time. " ::= { sm24tat4xbPerformanceMonitor 67 } sm24tat4xbDelayMeasureStateFtoNAvDelayTot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 68 } sm24tat4xbDelayMeasureStateFtoNAvDelaylastN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 69 } sm24tat4xbDelayMeasureStateFtoNDelayMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 70 } sm24tat4xbDelayMeasureStateFtoNDelayMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 71 } sm24tat4xbDelayMeasureStateFtoNAvDelayVarTot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 72 } sm24tat4xbDelayMeasureStateFtoNAvDelayVarlastN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay variation of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 73 } sm24tat4xbDelayMeasureStateFtoNDelayVarMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 74 } sm24tat4xbDelayMeasureStateFtoNDelayVarMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 75 } sm24tat4xbDelayMeasureStateFtoNOverflow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of counter overflow - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 76 } sm24tat4xbDelayMeasureStateNtoFTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated transmit count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 77 } sm24tat4xbDelayMeasureStateNtoFRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 78 } sm24tat4xbDelayMeasureStateNtoFRxTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive timeout count for two-way only - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 79 } sm24tat4xbDelayMeasureStateNtoFRxError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive error count - since last 'clear'. This is counting if the frame delay is larger than 1 second or if far end residence time is larger than the round trip time. " ::= { sm24tat4xbPerformanceMonitor 80 } sm24tat4xbDelayMeasureStateNtoFAvDelayTot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 81 } sm24tat4xbDelayMeasureStateNtoFAvDelaylastN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 82 } sm24tat4xbDelayMeasureStateNtoFDelayMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 83 } sm24tat4xbDelayMeasureStateNtoFDelayMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 84 } sm24tat4xbDelayMeasureStateNtoFAvDelayVarTot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 85 } sm24tat4xbDelayMeasureStateNtoFAvDelayVarlastN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay variation of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 86 } sm24tat4xbDelayMeasureStateNtoFDelayVarMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 87 } sm24tat4xbDelayMeasureStateNtoFDelayVarMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 88 } sm24tat4xbDelayMeasureStateNtoFOverflow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of counter overflow - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 89 } sm24tat4xbDelayMeasureStateTwowayTx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated transmit count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 90 } sm24tat4xbDelayMeasureStateTwowayRx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive count - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 91 } sm24tat4xbDelayMeasureStateTwowayRxTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive timeout count for two-way only - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 92 } sm24tat4xbDelayMeasureStateTwowayRxError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The accumulated receive error count - since last 'clear'. This is counting if the frame delay is larger than 1 second or if far end residence time is larger than the round trip time. " ::= { sm24tat4xbPerformanceMonitor 93 } sm24tat4xbDelayMeasureStateTwowayAvDelayTot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 94 } sm24tat4xbDelayMeasureStateTwowayAvDelaylastN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 95 } sm24tat4xbDelayMeasureStateTwowayDelayMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 96 } sm24tat4xbDelayMeasureStateTwowayDelayMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 97 } sm24tat4xbDelayMeasureStateTwowayAvDelayVarTot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average total delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 98 } sm24tat4xbDelayMeasureStateTwowayAvDelayVarlastN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The average delay variation of the last n packets - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 99 } sm24tat4xbDelayMeasureStateTwowayDelayVarMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 100 } sm24tat4xbDelayMeasureStateTwowayDelayVarMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum delay variation - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 101 } sm24tat4xbDelayMeasureStateTwowayOverflow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of counter overflow - since last 'clear'. " ::= { sm24tat4xbPerformanceMonitor 102 } sm24tat4xbDelayMeasureStateClear OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Set of this check and save will clear the accumulated counters. 1:clear " ::= { sm24tat4xbPerformanceMonitor 103 } sm24tat4xbDelayMeasureBinsMeasurementBinsforFD OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configurable number of Frame Delay Measurement Bins per Measurement Interval. range: 2-10 " ::= { sm24tat4xbPerformanceMonitor 104 } sm24tat4xbDelayMeasureBinsMeasurementBinsforIFDV OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configurable number of Inter-Frame Delay Variation Measurement Bins per Measurement Interval. range: 2-10 " ::= { sm24tat4xbPerformanceMonitor 105 } sm24tat4xbDelayMeasureBinsMeasurementThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configurable the Measurement Threshold for each Measurement Bin. " ::= { sm24tat4xbPerformanceMonitor 106 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPerformanceMonitorDelayMeasurementBinsforFDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMEP 16 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDEntry OBJECT-TYPE SYNTAX SM24TAT4XBPerformanceMonitorDelayMeasurementBinsforFDEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDIndex } ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDTable 1 } SM24TAT4XBPerformanceMonitorDelayMeasurementBinsforFDEntry ::= SEQUENCE { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDIndex Integer32, sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDOneway Integer32, sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDFtoN Integer32, sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDNtoF Integer32, sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDTwoway Integer32 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDEntry 1 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDOneway OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDEntry 2 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDFtoN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDEntry 3 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDNtoF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDEntry 4 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDTwoway OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforFDEntry 5 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPerformanceMonitorDelayMeasurementBinsforIFDVEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMEP 17 } sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVEntry OBJECT-TYPE SYNTAX SM24TAT4XBPerformanceMonitorDelayMeasurementBinsforIFDVEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVIndex } ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVTable 1 } SM24TAT4XBPerformanceMonitorDelayMeasurementBinsforIFDVEntry ::= SEQUENCE { sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVIndex Integer32, sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVOneway Integer32, sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVFtoN Integer32, sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVNtoF Integer32, sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVTwoway Integer32 } sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVEntry 1 } sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVOneway OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVEntry 2 } sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVFtoN OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVEntry 3 } sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVNtoF OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVEntry 4 } sm24tat4xbPerformanceMonitorDelayMeasureBinsforIFDVTwoway OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPerformanceMonitorDelayMeasurementBinsforIFDVEntry 5 } -- ============================================================================================================= sm24tat4xbPTP OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 28 } sm24tat4xbPTPExternalEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This Selection box will allow you to configure the External Clock output. The following values are possible: 1. True : Enable the external clock output 0. False : Disable the external clock output " ::= { sm24tat4xbPTP 1 } sm24tat4xbPTPAdjustMethod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This Selection box will allow you to configure the Frequency adjustment configuration. 0: LTC frequency : Select Local Time Counter (LTC) frequency control 1: SyncE-DPLL : Select SyncE DPLL frequency control, if allowed by SyncE 2: Oscillator : Select an oscillator independent of SyncE for frequency control, if supported by the HW 3: LTC phase : Select Local Time Counter (LTC) phase control (assumes that the frequency is locked by means of SyncE) " ::= { sm24tat4xbPTP 2 } sm24tat4xbPTPClockFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This will allow to set the Clock Frequency. The possible range of values are 1 - 25000000 (1 - 25MHz) " ::= { sm24tat4xbPTP 3 } sm24tat4xbPTPClockConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPTPClockConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of PTP Clock Conf." ::= { sm24tat4xbPTP 5 } sm24tat4xbPTPClockConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBPTPClockConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the PTP Clock Conf table." INDEX { sm24tat4xbPTPClockConfIndex } ::= { sm24tat4xbPTPClockConfTable 1 } SM24TAT4XBPTPClockConfEntry ::= SEQUENCE { sm24tat4xbPTPClockConfIndex Integer32, sm24tat4xbPTPClockConfClockInstance Integer32, sm24tat4xbPTPClockConfDeviceType Integer32, sm24tat4xbPTPClockConfProfile Integer32, sm24tat4xbPTPClockConfRowStatus RowStatus } sm24tat4xbPTPClockConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "PTP Clock Conf index." ::= {sm24tat4xbPTPClockConfEntry 1 } sm24tat4xbPTPClockConfClockInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the Instance of a particular Clock Instance [0..3]." ::= {sm24tat4xbPTPClockConfEntry 2 } sm24tat4xbPTPClockConfDeviceType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates the Type of the Clock Instance. There are five Device Types. 0: Inactive - passive clock instance 1: Ord-Bound - clock's Device Type is Ordinary-Boundary Clock. 2: P2p Transp - clock's Device Type is Peer to Peer Transparent Clock. 3: E2e Transp - clock's Device Type is End to End Transparent Clock. 4: Master Only - clock's Device Type is Master Only. 5: Slave Only - clock's Device Type is Slave Only. 6: Boundary Clock frontend clock instance, only 1-step, 1-way is supported." ::= {sm24tat4xbPTPClockConfEntry 3 } sm24tat4xbPTPClockConfProfile OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "0:No profile 1:1588 2:G8265.1 3:G8275.1 " ::= {sm24tat4xbPTPClockConfEntry 4 } sm24tat4xbPTPClockConfRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "PTP Clock Conf Row Status." ::= {sm24tat4xbPTPClockConfEntry 5 } sm24tat4xbPTPClockInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the PTP clock instance for the following item used [0..3]." ::= {sm24tat4xbPTP 6 } sm24tat4xbPTPClockConfAndStatus OBJECT IDENTIFIER ::= { sm24tat4xbPTP 7 } sm24tat4xbEntryClockInstance OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbPTPClockConfAndStatus 2 } sm24tat4xbEntryDeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbPTPClockConfAndStatus 3 } sm24tat4xbEntryProfile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= {sm24tat4xbPTPClockConfAndStatus 4 } sm24tat4xbEntryApplyProfileDefaults OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "-1:n/a 0:normal state 1:apply profile default" ::= {sm24tat4xbPTPClockConfAndStatus 5 } sm24tat4xbEntryPTPTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the actual PTP time with nanosecond resolution." ::= {sm24tat4xbPTPClockConfAndStatus 6 } sm24tat4xbEntryClockAdjustmentMethod OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the actual clock adjustment method. The method depends on the available hardware." ::= {sm24tat4xbPTPClockConfAndStatus 7 } sm24tat4xbEntrySynchronizeToSystemClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Activate this button to synchronize the System Clock to PTP Time. 1:Synchronize to system clock." ::= {sm24tat4xbPTPClockConfAndStatus 8 } sm24tat4xbEntryClockCurrentDataSetstpRm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Steps Removed : It is the number of PTP clocks traversed from the grandmaster to the local slave clock." ::= {sm24tat4xbPTPClockConfAndStatus 9 } sm24tat4xbEntryClockCurrentDataSetOffsetFromMaster OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Time difference between the master clock and the local slave clock, measured in ns." ::= {sm24tat4xbPTPClockConfAndStatus 10 } sm24tat4xbEntryClockCurrentDataSetMeanPathDelay OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The mean propagation time for the link between the master and the local slave." ::= {sm24tat4xbPTPClockConfAndStatus 11 } sm24tat4xbEntryClockCurrentDataSetSlavePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Shows which port is in slave mode. The value is 0 if no ports are in slave mode." ::= {sm24tat4xbPTPClockConfAndStatus 12 } sm24tat4xbEntryClockCurrentDataSetSlaveState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows synchronization state of the slave." ::= {sm24tat4xbPTPClockConfAndStatus 13 } sm24tat4xbEntryClockCurrentDataSetHoldover OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "After the slave has been in Locked mode during the stabilization period, this value shows the actual clock offset between the freerun and the actual holdover frequency, the value is shown in parts pr billion (ppb). During the stabilization period, the value is shown as N.A. The stabilization period is 60 sec as default, it can be changed from the CLI interface." ::= {sm24tat4xbPTPClockConfAndStatus 14 } sm24tat4xbEntryClockParentDataSetParentPortID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Clock identity for the parent clock, if the local clock is not a slave, the value is the clocks own id." ::= {sm24tat4xbPTPClockConfAndStatus 15 } sm24tat4xbEntryClockParentDataSetPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port Id for the parent master port" ::= {sm24tat4xbPTPClockConfAndStatus 16 } sm24tat4xbEntryClockParentDataSetPStat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Parents Stats (always false)." ::= {sm24tat4xbPTPClockConfAndStatus 17 } sm24tat4xbEntryClockParentDataSetVar OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "It is observed parent offset scaled log variance" ::= {sm24tat4xbPTPClockConfAndStatus 18 } sm24tat4xbEntryClockParentDataSetRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Observed Parent Clock Phase Change Rate. i.e. the slave clocks rate offset compared to the master. (unit = ns per s)." ::= {sm24tat4xbPTPClockConfAndStatus 19 } sm24tat4xbEntryClockParentDataSetGrandMasterID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Clock identity for the grand master clock, if the local clock is not a slave, the value is the clocks own id." ::= {sm24tat4xbPTPClockConfAndStatus 20 } sm24tat4xbParentDataSetGrandMasterClockQuality OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The clock quality announced by the grand master (See description of Clock Default DataSet:Clock Quality)" ::= {sm24tat4xbPTPClockConfAndStatus 21 } sm24tat4xbEntryClockParentDataSetPri1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Clock priority 1 announced by the grand master" ::= {sm24tat4xbPTPClockConfAndStatus 22 } sm24tat4xbEntryClockParentDataSetPri2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Clock priority 2 announced by the grand master." ::= {sm24tat4xbPTPClockConfAndStatus 23 } sm24tat4xbEntryClockDefaultDataSetClockID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "An internal instance id (0..3)" ::= {sm24tat4xbPTPClockConfAndStatus 24 } sm24tat4xbEntryClockDefaultDataSetDeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the Type of the Clock Instance. There are five Device Types. 1. Ord-Bound - Clock's Device Type is Ordinary-Boundary Clock. 2. P2p Transp - Clock's Device Type is Peer to Peer Transparent Clock. 3. E2e Transp - Clock's Device Type is End to End Transparent Clock. 4. Master Only - Clock's Device Type is Master Only. 5. Slave Only - Clock's Device Type is Slave Only." ::= {sm24tat4xbPTPClockConfAndStatus 25 } sm24tat4xbEntryClockDefaultDataSet2StepFlag OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "True if two-step Sync events and Pdelay_Resp events are used 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 26 } sm24tat4xbEntryClockDefaultDataSetPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of physical ports in the node" ::= {sm24tat4xbPTPClockConfAndStatus 27 } sm24tat4xbEntryClockDefaultDataSetClockIdentity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "It shows unique clock identifier" ::= {sm24tat4xbPTPClockConfAndStatus 28 } sm24tat4xbEntryClockDefaultDataSetDom OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Clock domain [0..127]." ::= {sm24tat4xbPTPClockConfAndStatus 29 } sm24tat4xbEntryClockDefaultDataSetClockQuality OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The clock quality is determined by the system, and holds 3 parts: Clock Class, Clock Accuracy and OffsetScaledLog Variance as defined in IEEE1588. The Clock Accuracy values are defined in IEEE1588 table 6 (Currently the clock Accuracy is set to 'Unknown' as default)." ::= {sm24tat4xbPTPClockConfAndStatus 30 } sm24tat4xbEntryClockDefaultDataSetPri1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Clock priority 1 [0..255] used by the BMC master select algorithm." ::= {sm24tat4xbPTPClockConfAndStatus 31 } sm24tat4xbEntryClockDefaultDataSetPri2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Clock priority 2 [0..255] used by the BMC master select algorithm." ::= {sm24tat4xbPTPClockConfAndStatus 32 } sm24tat4xbEntryClockDefaultDataSetProtocol OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:Ethernet 1:Ethernet Mixed 2:IP4Multi 3:IP4Mixed 4:IP4Uni 5:OAM" ::= {sm24tat4xbPTPClockConfAndStatus 33 } sm24tat4xbEntryClockDefaultDataSetOneWay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If true, one way measurements are used. This parameter applies only to a slave. In one-way mode no delay measurements are performed, i.e. this is applicable only if frequency synchronization is needed. The master always responds to delay requests. 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 34 } sm24tat4xbEntryClockDefaultDataSetVLANTagEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The VLAN Tag Enable parameter is ignored, because the tagging is controlled by the VLAN configuration. 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 35 } sm24tat4xbEntryClockDefaultDataSetVID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "TVLAN Identifier used for tagging the VLAN packets. range:1-4095" ::= {sm24tat4xbPTPClockConfAndStatus 36 } sm24tat4xbEntryClockDefaultDataSetPCP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Priority Code Point value used for PTP frames. range:0-7" ::= {sm24tat4xbPTPClockConfAndStatus 37 } sm24tat4xbEntryClockDefaultDataSetDSCP OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= {sm24tat4xbPTPClockConfAndStatus 38 } sm24tat4xbEntryClockTimePropertiesDataSetUtcOffset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range: 0-10000" ::= {sm24tat4xbPTPClockConfAndStatus 39 } sm24tat4xbEntryClockTimePropertiesDataSetValid OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 40 } sm24tat4xbEntryClockTimePropertiesDataSetLeap59 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 41 } sm24tat4xbEntryClockTimePropertiesDataSetLeap61 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 42 } sm24tat4xbEntryClockTimePropertiesDataSetTimeTrac OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 43 } sm24tat4xbEntryClockTimePropertiesDataSetFreqTrac OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 44 } sm24tat4xbTimePropertiesDataSetPTPTimeScale OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 45 } sm24tat4xbEntryClockTimePropertiesDataSetTimeSource OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range: 0-255" ::= {sm24tat4xbPTPClockConfAndStatus 46 } sm24tat4xbEntryFilterParametersFilterType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Shows the filter type used which can be either the basic filter or an advanced filter that can be configured to use only a fraction of the packets received (i.e. the packets that have experienced the least latency). 0:BASIC" ::= {sm24tat4xbPTPClockConfAndStatus 47 } sm24tat4xbEntryFilterParametersDelayFilter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-6" ::= {sm24tat4xbPTPClockConfAndStatus 48 } sm24tat4xbEntryFilterParametersPeriod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:1-10000" ::= {sm24tat4xbPTPClockConfAndStatus 49 } sm24tat4xbEntryFilterParametersDist OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:1-10" ::= {sm24tat4xbPTPClockConfAndStatus 50 } sm24tat4xbEntryServoParametersDisplay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If true then Offset From Master, MeanPathDelay and clockAdjustment are logged on the debug terminal 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 51 } sm24tat4xbEntryServoParametersPEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If true the P part of the algorithm is included 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 52 } sm24tat4xbEntryServoParametersIEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If true the I part of the algorithm is included 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 53 } sm24tat4xbEntryServoParametersDEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If true the D part of the algorithm is included 0:false 1:true" ::= {sm24tat4xbPTPClockConfAndStatus 54 } sm24tat4xbEntryServoParametersPConstant OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-1000" ::= {sm24tat4xbPTPClockConfAndStatus 55 } sm24tat4xbEntryServoParametersIConstant OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-10000" ::= {sm24tat4xbPTPClockConfAndStatus 56 } sm24tat4xbEntryServoParametersDConstant OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "range:0-1000" ::= {sm24tat4xbPTPClockConfAndStatus 57 } sm24tat4xbPTPClockPortDataSetConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPTPClockPortDataSetConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPTP 8 } sm24tat4xbPTPClockPortDataSetConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBPTPClockPortDataSetConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPTPClockPortDataSetConfPort } ::= { sm24tat4xbPTPClockPortDataSetConfTable 1 } SM24TAT4XBPTPClockPortDataSetConfEntry ::= SEQUENCE { sm24tat4xbPTPClockPortDataSetConfPort Integer32, sm24tat4xbPTPClockConfEntryPortConfEnable Integer32, sm24tat4xbPTPClockConfEntryPortConfStat DisplayString, sm24tat4xbPTPClockConfEntryPortConfMDR Integer32, sm24tat4xbPTPClockConfEntryPortConfPeerMeanPathDel DisplayString, sm24tat4xbPTPClockConfEntryPortConfAnv Integer32, sm24tat4xbPTPClockConfEntryPortConfATo Integer32, sm24tat4xbPTPClockConfEntryPortConfSyv Integer32, sm24tat4xbPTPClockConfEntryPortConfDlm Integer32, sm24tat4xbPTPClockConfEntryPortConfMPR Integer32, sm24tat4xbPTPClockConfEntryPortConfDelayAsymmetry Integer32, sm24tat4xbPTPClockConfEntryPortConfIngressLatency Integer32, sm24tat4xbPTPClockConfEntryPortConfEgressLatency Integer32, sm24tat4xbPTPClockConfEntryPortConfVersion Integer32 } sm24tat4xbPTPClockPortDataSetConfPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbPTPClockPortDataSetConfEntry 1 } sm24tat4xbPTPClockConfEntryPortConfEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0:false 1:true" ::= { sm24tat4xbPTPClockPortDataSetConfEntry 2 } sm24tat4xbPTPClockConfEntryPortConfStat OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Dynamic member portState: Current state of the port." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 3 } sm24tat4xbPTPClockConfEntryPortConfMDR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Dynamic member log Min Delay Req Interval: The delay request interval announced by the master." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 4 } sm24tat4xbPTPClockConfEntryPortConfPeerMeanPathDel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The path delay measured by the port in P2P mode. In E2E mode this value is 0" ::= { sm24tat4xbPTPClockPortDataSetConfEntry 5 } sm24tat4xbPTPClockConfEntryPortConfAnv OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The interval for issuing announce messages in master state. Range is -3 to 4." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 6 } sm24tat4xbPTPClockConfEntryPortConfATo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The timeout for receiving announce messages on the port. Range is 1 to 10." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 7 } sm24tat4xbPTPClockConfEntryPortConfSyv OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The interval for issuing sync messages in master. Range is -7 to 4." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 8 } sm24tat4xbPTPClockConfEntryPortConfDlm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configurable member delayMechanism: The delay mechanism used for the port: e2e End to end delay measurement p2p Peer to peer delay measurement. Can be defined per port in an Ordinary/Boundary clock. In a transparent clock all ports use the same delay mechanism, determined by the clock type. 1:e2e 2:p2p" ::= { sm24tat4xbPTPClockPortDataSetConfEntry 9 } sm24tat4xbPTPClockConfEntryPortConfMPR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The interval for issuing Delay_Req messages for the port in E2e mode. This value is announced from the master to the slave in an announce message. The value is reflected in the MDR field in the Slave The interval for issuing Pdelay_Req messages for the port in P2P mode Note: The interpretation of this parameter has changed from release 2.40. In earlier versions the value was interpreted relative to the Sync interval, this was a violation of the standard, so now the value is interpreted as an interval. I.e. MPR = 0 => 1 Delay_Req pr sec, independent of the Sync rate. Range is -7 to 5." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 10 } sm24tat4xbPTPClockConfEntryPortConfDelayAsymmetry OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If the transmission delay for a link in not symmetric, the asymmetry can be configured here, see IEEE 1588 Section 7.4.2 Communication path asymmetry Range is -100000 to 100000." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 11 } sm24tat4xbPTPClockConfEntryPortConfIngressLatency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Ingress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. Range is -100000 to 100000." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 12 } sm24tat4xbPTPClockConfEntryPortConfEgressLatency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Egress latency measured in ns, as defined in IEEE 1588 Section 7.3.4.2. Range is -100000 to 100000." ::= { sm24tat4xbPTPClockPortDataSetConfEntry 13 } sm24tat4xbPTPClockConfEntryPortConfVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current implementation only supports PTP version 2" ::= { sm24tat4xbPTPClockPortDataSetConfEntry 14 } sm24tat4xbPTPClockUnicastSlaveConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPTPClockUnicastSlaveConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPTP 9 } sm24tat4xbPTPClockUnicastSlaveConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBPTPClockUnicastSlaveConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPTPClockConfEntryUnicastSlaveConfIndex } ::= { sm24tat4xbPTPClockUnicastSlaveConfTable 1 } SM24TAT4XBPTPClockUnicastSlaveConfEntry ::= SEQUENCE { sm24tat4xbPTPClockConfEntryUnicastSlaveConfIndex Integer32, sm24tat4xbPTPClockConfEntryUnicastSlaveConfDuration Integer32, sm24tat4xbPTPClockConfEntryUnicastSlaveConfIPAddress IpAddress, sm24tat4xbPTPClockConfEntryUnicastSlaveConfGrant Integer32, sm24tat4xbPTPClockConfEntryUnicastSlaveConfCommState DisplayString } sm24tat4xbPTPClockConfEntryUnicastSlaveConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbPTPClockUnicastSlaveConfEntry 1 } sm24tat4xbPTPClockConfEntryUnicastSlaveConfDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of seconds a master is requested to send Announce/Sync messages. The request is repeated from the slave each Duration/4 seconds. range:10-1000" ::= { sm24tat4xbPTPClockUnicastSlaveConfEntry 2 } sm24tat4xbPTPClockConfEntryUnicastSlaveConfIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IPv4 Address of the Master clock" ::= { sm24tat4xbPTPClockUnicastSlaveConfEntry 3 } sm24tat4xbPTPClockConfEntryUnicastSlaveConfGrant OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The granted repetition period for the sync message" ::= { sm24tat4xbPTPClockUnicastSlaveConfEntry 4 } sm24tat4xbPTPClockConfEntryUnicastSlaveConfCommState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the communication with the master, possible values are: IDLE : The entry is not in use. INIT : Announce is sent to the master (Waiting for a response). CONN : The master has responded. SELL : The assigned master is selected as current master. SYNC : The master is sending Sync messages." ::= { sm24tat4xbPTPClockUnicastSlaveConfEntry 5 } -- ======================================================================================================================= sm24tat4xbETHLINKOAM OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 29 } sm24tat4xbEthLinkOAMPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEthLinkOAMPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbETHLINKOAM 1 } sm24tat4xbEthLinkOAMPortConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBEthLinkOAMPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbEthLinkOAMPortConfIndex } ::= { sm24tat4xbEthLinkOAMPortConfTable 1 } SM24TAT4XBEthLinkOAMPortConfEntry ::= SEQUENCE { sm24tat4xbEthLinkOAMPortConfIndex Integer32, sm24tat4xbEthLinkOAMPortConfOAMEnable Integer32, sm24tat4xbEthLinkOAMPortConfOAMMode Integer32, sm24tat4xbEthLinkOAMPortConfLoopbackSupport Integer32, sm24tat4xbEthLinkOAMPortConfLinkMonitorSupport Integer32, sm24tat4xbEthLinkOAMPortConfMIBRetrievalSupport Integer32, sm24tat4xbEthLinkOAMPortConfLoopbackOperation Integer32 } sm24tat4xbEthLinkOAMPortConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEthLinkOAMPortConfEntry 1 } sm24tat4xbEthLinkOAMPortConfOAMEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether Link OAM is enabled on this switch port. Enabling Link OAM provides the network operators the ability to monitor the health of the network and quickly determine the location of failing links or fault conditions. 0:disable 1:enable" ::= { sm24tat4xbEthLinkOAMPortConfEntry 2 } sm24tat4xbEthLinkOAMPortConfOAMMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Configures the OAM Mode as Active or Passive. The default mode is Passive. 0:Passive mode 1:Active mode" ::= { sm24tat4xbEthLinkOAMPortConfEntry 3 } sm24tat4xbEthLinkOAMPortConfLoopbackSupport OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the loopback support is enabled for the switch port. 0:disable 1:enable" ::= { sm24tat4xbEthLinkOAMPortConfEntry 4 } sm24tat4xbEthLinkOAMPortConfLinkMonitorSupport OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the Link Monitor support is enabled for the switch port. 0:disable 1:enable" ::= { sm24tat4xbEthLinkOAMPortConfEntry 5 } sm24tat4xbEthLinkOAMPortConfMIBRetrievalSupport OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the MIB Retrieval Support is enabled for the switch port. 0:disable 1:enable" ::= { sm24tat4xbEthLinkOAMPortConfEntry 6 } sm24tat4xbEthLinkOAMPortConfLoopbackOperation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If the Loopback support is enabled, enabling this field will start a loopback operation for the port. 0:disable 1:enable" ::= { sm24tat4xbEthLinkOAMPortConfEntry 7 } sm24tat4xbEthLinkOAMPortDetailStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEthLinkOAMPortDetailStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Detail Status table" ::= { sm24tat4xbETHLINKOAM 2 } sm24tat4xbEthLinkOAMPortDetailStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBEthLinkOAMPortDetailStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Detail Status entry" INDEX { sm24tat4xbEthLinkOAMPortDetailStatusIndex } ::= { sm24tat4xbEthLinkOAMPortDetailStatusTable 1 } SM24TAT4XBEthLinkOAMPortDetailStatusEntry ::= SEQUENCE { sm24tat4xbEthLinkOAMPortDetailStatusIndex Integer32, sm24tat4xbEthLinkOAMPortPDUPermission DisplayString, sm24tat4xbEthLinkOAMPortDiscoveryState DisplayString, sm24tat4xbEthLinkOAMPortPeerMACAddress DisplayString, sm24tat4xbEthLinkOAMPortLocalMode DisplayString, sm24tat4xbEthLinkOAMPortLocalUnidirectionalOperationSupport DisplayString, sm24tat4xbEthLinkOAMPortLocalRemoteLoopbackSupport DisplayString, sm24tat4xbEthLinkOAMPortLocalLinkMonitoringSupport DisplayString, sm24tat4xbEthLinkOAMPortLocalMIBRetrievalSupport DisplayString, sm24tat4xbEthLinkOAMPortLocalMTUSize Integer32, sm24tat4xbEthLinkOAMPortLocalMultiplexerState DisplayString, sm24tat4xbEthLinkOAMPortLocalParserState DisplayString, sm24tat4xbEthLinkOAMPortLocalOrganizationalUniqueIdent DisplayString, sm24tat4xbEthLinkOAMPortLocalPDURevision Integer32, sm24tat4xbEthLinkOAMPortPeerMode DisplayString, sm24tat4xbEthLinkOAMPortPeerUnidirectionalOperationSupport DisplayString, sm24tat4xbEthLinkOAMPortPeerRemoteLoopbackSupport DisplayString, sm24tat4xbEthLinkOAMPortPeerLinkMonitoringSupport DisplayString, sm24tat4xbEthLinkOAMPortPeerMIBRetrievalSupport DisplayString, sm24tat4xbEthLinkOAMPortPeerMTUSize DisplayString, sm24tat4xbEthLinkOAMPortPeerMultiplexerState DisplayString, sm24tat4xbEthLinkOAMPortPeerParserState DisplayString, sm24tat4xbEthLinkOAMPortPeerOrganizationalUniqueIdent DisplayString, sm24tat4xbEthLinkOAMPortPDURevision DisplayString } sm24tat4xbEthLinkOAMPortDetailStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 1 } sm24tat4xbEthLinkOAMPortPDUPermission OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This field is available only for the Local DTE. It displays the current permission rules set for the local DTE. Possible values are Link fault, Receive only, Information exchange only, ANY." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 2 } sm24tat4xbEthLinkOAMPortDiscoveryState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the current state of the discovery process. Possible states are Fault state, Active state, Passive state, SEND_LOCAL_REMOTE_STATE, SEND_LOCAL_REMOTE_OK_STATE, SEND_ANY_STATE." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 3 } sm24tat4xbEthLinkOAMPortPeerMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 4 } sm24tat4xbEthLinkOAMPortLocalMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Mode in which the Link OAM is operating, Active or Passive." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 5 } sm24tat4xbEthLinkOAMPortLocalUnidirectionalOperationSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This feature is not available to be configured by the user. The status of this configuration is retrieved from the PHY." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 6 } sm24tat4xbEthLinkOAMPortLocalRemoteLoopbackSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If status is enabled, DTE is capable of OAM remote loopback mode." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 7 } sm24tat4xbEthLinkOAMPortLocalLinkMonitoringSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If status is enabled, DTE supports interpreting Link Events." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 8 } sm24tat4xbEthLinkOAMPortLocalMIBRetrievalSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If status ie enabled DTE supports sending Variable Response OAMPDUs." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 9 } sm24tat4xbEthLinkOAMPortLocalMTUSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "It represents the largest OAMPDU, in octets, supported by the DTE. This value is compared to the remotes Maximum PDU Size and the smaller of the two is used." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 10 } sm24tat4xbEthLinkOAMPortLocalMultiplexerState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "When in forwarding state, the Device is forwarding non-OAMPDUs to the lower sublayer. Incase of discarding, the device discards all the non-OAMPDU's." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 11 } sm24tat4xbEthLinkOAMPortLocalParserState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "When in forwarding state, Device is forwarding non-OAMPDUs to higher sublayer. When in loopback, Device is looping back non-OAMPDUs to the lower sublayer. When in discarding state, Device is discarding non-OAMPDUs." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 12 } sm24tat4xbEthLinkOAMPortLocalOrganizationalUniqueIdent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "24-bit Organizationally Unique Identifier of the vendor." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 13 } sm24tat4xbEthLinkOAMPortLocalPDURevision OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "It indicates the current revision of the Information TLV. The value of this field shall start at zero and be incremented each time something in the Information TLV changes. Upon reception of an Information TLV from a peer, an OAM client may use this field to decide if it needs to be processed (an Information TLV that is identical to the previous Information TLV doesn't need to be parsed as nothing in it has changed)." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 14 } sm24tat4xbEthLinkOAMPortPeerMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Mode in which the Link OAM is operating, Active or Passive." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 15 } sm24tat4xbEthLinkOAMPortPeerUnidirectionalOperationSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This feature is not available to be configured by the user. The status of this configuration is retrieved from the PHY." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 16 } sm24tat4xbEthLinkOAMPortPeerRemoteLoopbackSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If status is enabled, DTE is capable of OAM remote loopback mode." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 17 } sm24tat4xbEthLinkOAMPortPeerLinkMonitoringSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If status is enabled, DTE supports interpreting Link Events." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 18 } sm24tat4xbEthLinkOAMPortPeerMIBRetrievalSupport OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "If status ie enabled DTE supports sending Variable Response OAMPDUs." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 19 } sm24tat4xbEthLinkOAMPortPeerMTUSize OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "It represents the largest OAMPDU, in octets, supported by the DTE. This value is compared to the remotes Maximum PDU Size and the smaller of the two is used." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 20 } sm24tat4xbEthLinkOAMPortPeerMultiplexerState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "When in forwarding state, the Device is forwarding non-OAMPDUs to the lower sublayer. Incase of discarding, the device discards all the non-OAMPDU's." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 21 } sm24tat4xbEthLinkOAMPortPeerParserState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "When in forwarding state, Device is forwarding non-OAMPDUs to higher sublayer. When in loopback, Device is looping back non-OAMPDUs to the lower sublayer. When in discarding state, Device is discarding non-OAMPDUs." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 22 } sm24tat4xbEthLinkOAMPortPeerOrganizationalUniqueIdent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "24-bit Organizationally Unique Identifier of the vendor." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 23 } sm24tat4xbEthLinkOAMPortPDURevision OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "It indicates the current revision of the Information TLV. The value of this field shall start at zero and be incremented each time something in the Information TLV changes. Upon reception of an Information TLV from a peer, an OAM client may use this field to decide if it needs to be processed (an Information TLV that is identical to the previous Information TLV doesn't need to be parsed as nothing in it has changed)." ::= { sm24tat4xbEthLinkOAMPortDetailStatusEntry 24 } sm24tat4xbEthLinkOAMPortLinkEventConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEthLinkOAMPortLinkEventConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Link Event Conf Table" ::= { sm24tat4xbETHLINKOAM 3 } sm24tat4xbEthLinkOAMPortLinkEventConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBEthLinkOAMPortLinkEventConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Link Event Conf Entry" INDEX { sm24tat4xbEventConfIndex } ::= { sm24tat4xbEthLinkOAMPortLinkEventConfTable 1 } SM24TAT4XBEthLinkOAMPortLinkEventConfEntry ::= SEQUENCE { sm24tat4xbEventConfIndex Integer32, sm24tat4xbEventConfErrorFrameEventErrorWindow Integer32, sm24tat4xbEventConfErrorFrameEventErrorThreshold Integer32, sm24tat4xbEventConfSymbolPeriodErrorEventErrorWindow Integer32, sm24tat4xbEventConfSymbolPeriodErrorEventErrorThreshold Integer32, sm24tat4xbEventConfSecondsSummaryEventErrorWindow Integer32, sm24tat4xbEventConfSecondsSummaryEventErrorThreshold Integer32 } sm24tat4xbEventConfIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 1 } sm24tat4xbEventConfErrorFrameEventErrorWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Errored Frame Event counts the number of errored frames detected during the specified period. Represents the window period in the order of 1 sec for the observation of various link events. range: 1-60" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 2 } sm24tat4xbEventConfErrorFrameEventErrorThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Errored Frame Event counts the number of errored frames detected during the specified period. Represents the threshold value for the window period for the appropriate Link event so as to notify the peer of this error. range:0-0xffffffff" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 3 } sm24tat4xbEventConfSymbolPeriodErrorEventErrorWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Errored Symbol Period Event counts the number of symbol errors that occurred during the specified period. Represents the window period in the order of 1 sec for the observation of various link events. range: 1-60" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 4 } sm24tat4xbEventConfSymbolPeriodErrorEventErrorThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Errored Symbol Period Event counts the number of symbol errors that occurred during the specified period. Represents the threshold value for the window period for the appropriate Link event so as to notify the peer of this error. range:0-0xffffffff" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 5 } sm24tat4xbEventConfSecondsSummaryEventErrorWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Errored Frame Seconds Summary Event TLV counts the number of errored frame seconds that occurred during the specified period. Represents the window period in the order of 1 sec for the observation of various link events. range: 10-900" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 6 } sm24tat4xbEventConfSecondsSummaryEventErrorThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Errored Frame Seconds Summary Event TLV counts the number of errored frame seconds that occurred during the specified period. Represents the threshold value for the window period for the appropriate Link event so as to notify the peer of this error. range:0-0xffff" ::= { sm24tat4xbEthLinkOAMPortLinkEventConfEntry 7 } sm24tat4xbEthLinkOAMPortDetailedStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEthLinkOAMPortDetailedStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Detailed Statistics Table" ::= { sm24tat4xbETHLINKOAM 4 } sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBEthLinkOAMPortDetailedStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Detailed Statistics Entry" INDEX { sm24tat4xbStatisticsIndex } ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsTable 1 } SM24TAT4XBEthLinkOAMPortDetailedStatisticsEntry ::= SEQUENCE { sm24tat4xbStatisticsIndex Integer32, sm24tat4xbStatisticsRxOAMInformationPDUs Integer32, sm24tat4xbStatisticsRxUniqueErrorEventNotification Integer32, sm24tat4xbStatisticsRxDuplicateErrorEventNotification Integer32, sm24tat4xbStatisticsRxLoopbackControl Integer32, sm24tat4xbStatisticsRxVariableRequest Integer32, sm24tat4xbStatisticsRxVariableResponse Integer32, sm24tat4xbStatisticsRxOrgSpecificPDUs Integer32, sm24tat4xbStatisticsRxUnsupportedCodes Integer32, sm24tat4xbStatisticsRxLinkFaultPDUs Integer32, sm24tat4xbStatisticsRxDyingGasp Integer32, sm24tat4xbStatisticsRxCriticalEventPDUs Integer32, sm24tat4xbStatisticsTxOAMInformationPDUs Integer32, sm24tat4xbStatisticsTxUniqueErrorEventNotification Integer32, sm24tat4xbStatisticsTxDuplicateErrorEventNotification Integer32, sm24tat4xbStatisticsTxLoopbackControl Integer32, sm24tat4xbStatisticsTxVariableRequest Integer32, sm24tat4xbStatisticsTxVariableResponse Integer32, sm24tat4xbStatisticsTxOrgSpecificPDUs Integer32, sm24tat4xbStatisticsTxUnsupportedCodes Integer32, sm24tat4xbStatisticsTxLinkFaultPDUs Integer32, sm24tat4xbStatisticsTxDyingGasp Integer32, sm24tat4xbStatisticsTxCriticalEventPDUs Integer32, sm24tat4xbStatisticsClear Integer32 } sm24tat4xbStatisticsIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 1 } sm24tat4xbStatisticsRxOAMInformationPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received and transmitted OAM Information PDU's. Discontinuities of this counter can occur at re-initialization of the management system." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 2 } sm24tat4xbStatisticsRxUniqueErrorEventNotification OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of unique Event OAMPDUs received and transmitted on this interface. Event Notifications may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. Duplicate Event Notification transmissions are counted by Duplicate Event Notification counters for Tx and Rx respectively. A unique Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is distinct from the previously transmitted Event Notification OAMPDU Sequence Number." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 3 } sm24tat4xbStatisticsRxDuplicateErrorEventNotification OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of duplicate Event OAMPDUs received and transmitted on this interface. Event Notification OAMPDUs may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. A duplicate Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is identical to the previously transmitted Event Notification OAMPDU Sequence Number." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 4 } sm24tat4xbStatisticsRxLoopbackControl OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Loopback Control OAMPDUs received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 5 } sm24tat4xbStatisticsRxVariableRequest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Request OAMPDUs received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 6 } sm24tat4xbStatisticsRxVariableResponse OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Response OAMPDUs received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 7 } sm24tat4xbStatisticsRxOrgSpecificPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Organization Specific OAMPDUs transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 8 } sm24tat4xbStatisticsRxUnsupportedCodes OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of OAMPDUs transmitted on this interface with an unsupported op-code." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 9 } sm24tat4xbStatisticsRxLinkFaultPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Link fault PDU's received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 10 } sm24tat4xbStatisticsRxDyingGasp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Dying Gasp events received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 11 } sm24tat4xbStatisticsRxCriticalEventPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Critical event PDU's received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 12 } sm24tat4xbStatisticsTxOAMInformationPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received and transmitted OAM Information PDU's. Discontinuities of this counter can occur at re-initialization of the management system." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 13 } sm24tat4xbStatisticsTxUniqueErrorEventNotification OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of unique Event OAMPDUs received and transmitted on this interface. Event Notifications may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. Duplicate Event Notification transmissions are counted by Duplicate Event Notification counters for Tx and Rx respectively. A unique Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is distinct from the previously transmitted Event Notification OAMPDU Sequence Number." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 14 } sm24tat4xbStatisticsTxDuplicateErrorEventNotification OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of duplicate Event OAMPDUs received and transmitted on this interface. Event Notification OAMPDUs may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. A duplicate Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is identical to the previously transmitted Event Notification OAMPDU Sequence Number." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 15 } sm24tat4xbStatisticsTxLoopbackControl OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Loopback Control OAMPDUs received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 16 } sm24tat4xbStatisticsTxVariableRequest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Request OAMPDUs received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 17 } sm24tat4xbStatisticsTxVariableResponse OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Response OAMPDUs received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 18 } sm24tat4xbStatisticsTxOrgSpecificPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Organization Specific OAMPDUs transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 19 } sm24tat4xbStatisticsTxUnsupportedCodes OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of OAMPDUs transmitted on this interface with an unsupported op-code." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 20 } sm24tat4xbStatisticsTxLinkFaultPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Link fault PDU's received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 21 } sm24tat4xbStatisticsTxDyingGasp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Dying Gasp events received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 22 } sm24tat4xbStatisticsTxCriticalEventPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Critical event PDU's received and transmitted on this interface." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 23 } sm24tat4xbStatisticsClear OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Clears the counters for the selected port." ::= { sm24tat4xbEthLinkOAMPortDetailedStatisticsEntry 24 } sm24tat4xbEthLinkOAMPortEventDetailedStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEthLinkOAMPortEventDetailedStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Event Detailed Statistics Table" ::= { sm24tat4xbETHLINKOAM 5 } sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBEthLinkOAMPortEventDetailedStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Eth Link OAM Port Event Detailed Statistics Entry" INDEX { sm24tat4xbDetailedStatisticsIndex } ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsTable 1 } SM24TAT4XBEthLinkOAMPortEventDetailedStatisticsEntry ::= SEQUENCE { sm24tat4xbDetailedStatisticsIndex Integer32, sm24tat4xbStatisticsLocalSequenceNumber Integer32, sm24tat4xbStatisticsLocalFrameErrorEventTimestamp Integer32, sm24tat4xbStatisticsLocalFrameErrorEventWindow Integer32, sm24tat4xbStatisticsLocalFrameErrorEventThreshold Integer32, sm24tat4xbStatisticsLocalFrameErrors Integer32, sm24tat4xbStatisticsLocalTotalFrameErrors Counter64, sm24tat4xbStatisticsLocalTotalFrameErrorEvents Integer32, sm24tat4xbStatisticsLocalFramePeriodErrorEventTimestamp Integer32, sm24tat4xbStatisticsLocalFramePeriodErrorEventWindow Integer32, sm24tat4xbStatisticsLocalFramePeriodErrorEventThreshold Integer32, sm24tat4xbStatisticsLocalFramePeriodErrors Integer32, sm24tat4xbStatisticsLocalTotalFramePeriodErrors Counter64, sm24tat4xbStatisticsLocalTotalFramePeriodErrorEvents Integer32, sm24tat4xbStatisticsLocalSymbolPeriodErrorEventTimestamp Integer32, sm24tat4xbStatisticsLocalSymbolPeriodErrorEventWindow Counter64, sm24tat4xbStatisticsLocalSymbolPeriodErrorEventThreshold Counter64, sm24tat4xbStatisticsLocalSymbolPeriodErrors Counter64, sm24tat4xbStatisticsLocalSymbolFramePeriodErrors Counter64, sm24tat4xbStatisticsLocalSymbolFramePeriodErrorEvents Integer32, sm24tat4xbStatisticsLocalEventSecondsSummaryTimeStamp Integer32, sm24tat4xbStatisticsLocalEventSecondsSummaryWindow Integer32, sm24tat4xbStatisticsLocalEventSecondsSummaryThreshold Integer32, sm24tat4xbStatisticsLocalEventSecondsSummaryEvents Integer32, sm24tat4xbStatisticsLocalEventSecondsSummaryErrorTotal Integer32, sm24tat4xbStatisticsLocalEventSecondsSummaryEventTotal Integer32, sm24tat4xbStatisticsRemoteFrameErrorEventTimestamp Integer32, sm24tat4xbStatisticsRemoteFrameErrorEventWindow Integer32, sm24tat4xbStatisticsRemoteFrameErrorEventThreshold Integer32, sm24tat4xbStatisticsRemoteFrameErrors Integer32, sm24tat4xbStatisticsRemoteTotalFrameErrors Counter64, sm24tat4xbStatisticsRemoteTotalFrameErrorEvents Integer32, sm24tat4xbStatisticsRemoteFramePeriodErrorEventTimestamp Integer32, sm24tat4xbStatisticsRemoteFramePeriodErrorEventWindow Integer32, sm24tat4xbStatisticsRemoteFramePeriodErrorEventThreshold Integer32, sm24tat4xbStatisticsRemoteFramePeriodErrors Integer32, sm24tat4xbStatisticsRemoteTotalFramePeriodErrors Counter64, sm24tat4xbStatisticsRemoteTotalFramePeriodErrorEvents Integer32, sm24tat4xbStatisticsRemoteSymbolPeriodErrorEventTimestamp Integer32, sm24tat4xbStatisticsRemoteSymbolPeriodErrorEventWindow Counter64, sm24tat4xbStatisticsRemoteSymbolPeriodErrorEventThreshold Counter64, sm24tat4xbStatisticsRemoteSymbolPeriodErrors Counter64, sm24tat4xbStatisticsRemoteSymbolFramePeriodErrors Counter64, sm24tat4xbStatisticsRemoteSymbolFramePeriodErrorEvents Integer32, sm24tat4xbStatisticsRemoteEventSecondsSummaryTimeStamp Integer32, sm24tat4xbStatisticsRemoteEventSecondsSummaryWindow Integer32, sm24tat4xbStatisticsRemoteEventSecondsSummaryThreshold Integer32, sm24tat4xbStatisticsRemoteEventSecondsSummaryEvents Integer32, sm24tat4xbStatisticsRemoteEventSecondsSummaryErrorTotal Integer32, sm24tat4xbStatisticsRemoteEventSecondsSummaryEventTotal Integer32 } sm24tat4xbDetailedStatisticsIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 1 } sm24tat4xbStatisticsLocalSequenceNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the total number of events occurred at the remote end." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 2 } sm24tat4xbStatisticsLocalFrameErrorEventTimestamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 3 } sm24tat4xbStatisticsLocalFrameErrorEventWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the duration of the period in terms of 100 ms intervals. 1) The default value is one second. 2) The lower bound is one second. 3) The upper bound is one minute." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 4 } sm24tat4xbStatisticsLocalFrameErrorEventThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of detected errored frames in the period is required to be equal to or greater than in order for the event to be generated. 1) The default value is one frame error. 2) The lower bound is zero frame errors. 3) The upper bound is unspecified." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 5 } sm24tat4xbStatisticsLocalFrameErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of detected errored frames in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 6 } sm24tat4xbStatisticsLocalTotalFrameErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the sum of errored frames that have been detected since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 7 } sm24tat4xbStatisticsLocalTotalFrameErrorEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Frame Event TLVs that have been generated since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 8 } sm24tat4xbStatisticsLocalFramePeriodErrorEventTimestamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 9 } sm24tat4xbStatisticsLocalFramePeriodErrorEventWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the duration of period in terms of frames." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 10 } sm24tat4xbStatisticsLocalFramePeriodErrorEventThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of errored frames in the period is required to be equal to or greater than in order for the event to be generated." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 11 } sm24tat4xbStatisticsLocalFramePeriodErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of frame errors in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 12 } sm24tat4xbStatisticsLocalTotalFramePeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the sum of frame errors that have been detected since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 13 } sm24tat4xbStatisticsLocalTotalFramePeriodErrorEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Frame Period Event TLVs that have been generated since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 14 } sm24tat4xbStatisticsLocalSymbolPeriodErrorEventTimestamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 15 } sm24tat4xbStatisticsLocalSymbolPeriodErrorEventWindow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the number of symbols in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 16 } sm24tat4xbStatisticsLocalSymbolPeriodErrorEventThreshold OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the number of errored symbols in the period is required to be equal to or greater than in order for the event to be generated." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 17 } sm24tat4xbStatisticsLocalSymbolPeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the number of symbol errors in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 18 } sm24tat4xbStatisticsLocalSymbolFramePeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the sum of symbol errors since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 19 } sm24tat4xbStatisticsLocalSymbolFramePeriodErrorEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Symbol Period Event TLVs that have been generated since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 20 } sm24tat4xbStatisticsLocalEventSecondsSummaryTimeStamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 21 } sm24tat4xbStatisticsLocalEventSecondsSummaryWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the duration of the period in terms of 100 ms intervals, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 22 } sm24tat4xbStatisticsLocalEventSecondsSummaryThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the number of errored frame seconds in the period is required to be equal to or greater than in order for the event to be generated, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 23 } sm24tat4xbStatisticsLocalEventSecondsSummaryEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the number of errored frame seconds in the period, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 24 } sm24tat4xbStatisticsLocalEventSecondsSummaryErrorTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the sum of errored frame seconds that have been detected since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 25 } sm24tat4xbStatisticsLocalEventSecondsSummaryEventTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Frame Seconds Summary Event TLVs that have been generated since the OAM sublayer was reset, encoded as a 32bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 26 } sm24tat4xbStatisticsRemoteFrameErrorEventTimestamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 27 } sm24tat4xbStatisticsRemoteFrameErrorEventWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the duration of the period in terms of 100 ms intervals. 1) The default value is one second. 2) The lower bound is one second. 3) The upper bound is one minute." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 28 } sm24tat4xbStatisticsRemoteFrameErrorEventThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of detected errored frames in the period is required to be equal to or greater than in order for the event to be generated. 1) The default value is one frame error. 2) The lower bound is zero frame errors. 3) The upper bound is unspecified." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 29 } sm24tat4xbStatisticsRemoteFrameErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of detected errored frames in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 30 } sm24tat4xbStatisticsRemoteTotalFrameErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the sum of errored frames that have been detected since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 31 } sm24tat4xbStatisticsRemoteTotalFrameErrorEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Frame Event TLVs that have been generated since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 32 } sm24tat4xbStatisticsRemoteFramePeriodErrorEventTimestamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 33 } sm24tat4xbStatisticsRemoteFramePeriodErrorEventWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the duration of period in terms of frames." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 34 } sm24tat4xbStatisticsRemoteFramePeriodErrorEventThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of errored frames in the period is required to be equal to or greater than in order for the event to be generated." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 35 } sm24tat4xbStatisticsRemoteFramePeriodErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of frame errors in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 36 } sm24tat4xbStatisticsRemoteTotalFramePeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the sum of frame errors that have been detected since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 37 } sm24tat4xbStatisticsRemoteTotalFramePeriodErrorEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Frame Period Event TLVs that have been generated since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 38 } sm24tat4xbStatisticsRemoteSymbolPeriodErrorEventTimestamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 39 } sm24tat4xbStatisticsRemoteSymbolPeriodErrorEventWindow OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the number of symbols in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 40 } sm24tat4xbStatisticsRemoteSymbolPeriodErrorEventThreshold OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the number of errored symbols in the period is required to be equal to or greater than in order for the event to be generated." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 41 } sm24tat4xbStatisticsRemoteSymbolPeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the number of symbol errors in the period." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 42 } sm24tat4xbStatisticsRemoteSymbolFramePeriodErrors OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION "This eight-octet field indicates the sum of symbol errors since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 43 } sm24tat4xbStatisticsRemoteSymbolFramePeriodErrorEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Symbol Period Event TLVs that have been generated since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 44 } sm24tat4xbStatisticsRemoteEventSecondsSummaryTimeStamp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the time reference when the event was generated, in terms of 100 ms intervals, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 45 } sm24tat4xbStatisticsRemoteEventSecondsSummaryWindow OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the duration of the period in terms of 100 ms intervals, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 46 } sm24tat4xbStatisticsRemoteEventSecondsSummaryThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the number of errored frame seconds in the period is required to be equal to or greater than in order for the event to be generated, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 47 } sm24tat4xbStatisticsRemoteEventSecondsSummaryEvents OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This two-octet field indicates the number of errored frame seconds in the period, encoded as a 16-bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 48 } sm24tat4xbStatisticsRemoteEventSecondsSummaryErrorTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the sum of errored frame seconds that have been detected since the OAM sublayer was reset." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 49 } sm24tat4xbStatisticsRemoteEventSecondsSummaryEventTotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This four-octet field indicates the number of Errored Frame Seconds Summary Event TLVs that have been generated since the OAM sublayer was reset, encoded as a 32bit unsigned integer." ::= { sm24tat4xbEthLinkOAMPortEventDetailedStatisticsEntry 50 } sm24tat4xbIPMC OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 32 } sm24tat4xbIGMPSnooping OBJECT IDENTIFIER ::= { sm24tat4xbIPMC 1 } sm24tat4xbIGMPSnoopingBasicConfigSnoopingEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Snooping Enabled 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnooping 2 } sm24tat4xbIGMPSnoopingUnregisteredIPMCv4FloodingEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Unregistered IPMCv4 Flooding Enabled 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnooping 3 } sm24tat4xbIGMPSnoopingBasicConfigIGMPSSMRange OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IGMP SSM Range IPv4 multicast address." ::= { sm24tat4xbIGMPSnooping 4 } sm24tat4xbIGMPSnoopingBasicConfigIGMPSSMRangeLength OBJECT-TYPE SYNTAX Integer32(4..32) MAX-ACCESS read-write STATUS current DESCRIPTION "IGMP SSM Range prefix. " ::= { sm24tat4xbIGMPSnooping 5 } sm24tat4xbIGMPSnoopingBasicConfigLeaveProxyEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Leave Proxy Enabled 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnooping 6 } sm24tat4xbIGMPSnoopingBasicConfigProxyEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Proxy Enabled 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnooping 7 } sm24tat4xbIGMPSnoopingPortRelatedTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIGMPSnoopingPortRelatedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbIGMPSnooping 8 } sm24tat4xbIGMPSnoopingPortRelatedEntry OBJECT-TYPE SYNTAX SM24TAT4XBIGMPSnoopingPortRelatedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbIGMPSnoopingPortRelatedPort } ::= { sm24tat4xbIGMPSnoopingPortRelatedTable 1 } SM24TAT4XBIGMPSnoopingPortRelatedEntry ::= SEQUENCE { sm24tat4xbIGMPSnoopingPortRelatedPort Integer32, sm24tat4xbIGMPSnoopingPortRouterPort Integer32, sm24tat4xbIGMPSnoopingPortFastLeave Integer32, sm24tat4xbIGMPSnoopingPortThrottling Integer32, sm24tat4xbIGMPSnoopingPortFilteringProfile DisplayString } sm24tat4xbIGMPSnoopingPortRelatedPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbIGMPSnoopingPortRelatedEntry 1 } sm24tat4xbIGMPSnoopingPortRouterPort OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Router Port 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnoopingPortRelatedEntry 2 } sm24tat4xbIGMPSnoopingPortFastLeave OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Fast Leave 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnoopingPortRelatedEntry 3 } sm24tat4xbIGMPSnoopingPortThrottling OBJECT-TYPE SYNTAX Integer32(0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Throttling. Range: 0:unlimited, 1-10" ::= { sm24tat4xbIGMPSnoopingPortRelatedEntry 4 } sm24tat4xbIGMPSnoopingPortFilteringProfile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Filtering Profile" ::= { sm24tat4xbIGMPSnoopingPortRelatedEntry 5 } sm24tat4xbIGMPSnoopingVLANConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIGMPSnoopingVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbIGMPSnooping 9 } sm24tat4xbIGMPSnoopingVLANConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBIGMPSnoopingVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbIGMPSnoopingVLANConfigIndex } ::= { sm24tat4xbIGMPSnoopingVLANConfigTable 1 } SM24TAT4XBIGMPSnoopingVLANConfigEntry ::= SEQUENCE { sm24tat4xbIGMPSnoopingVLANConfigIndex Integer32, sm24tat4xbIGMPSnoopingVLANConfigVLANID Integer32, sm24tat4xbIGMPSnoopingVLANConfigSnoopingEnabled Integer32, sm24tat4xbIGMPSnoopingVLANConfigQuerierElection Integer32, sm24tat4xbIGMPSnoopingVLANConfigQuerierAddress IpAddress, sm24tat4xbIGMPSnoopingVLANConfigCompatibility Integer32, sm24tat4xbIGMPSnoopingVLANConfigPRI Integer32, sm24tat4xbIGMPSnoopingVLANConfigRV Integer32, sm24tat4xbIGMPSnoopingVLANConfigQI Integer32, sm24tat4xbIGMPSnoopingVLANConfigQRI Integer32, sm24tat4xbIGMPSnoopingVLANConfigLLQI Integer32, sm24tat4xbIGMPSnoopingVLANConfigURI Integer32 } sm24tat4xbIGMPSnoopingVLANConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 1 } sm24tat4xbIGMPSnoopingVLANConfigVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 2 } sm24tat4xbIGMPSnoopingVLANConfigSnoopingEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IGMP Snooping Enabled 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 3 } sm24tat4xbIGMPSnoopingVLANConfigQuerierElection OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Querier Election 0:Disable 1:Enable" ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 4 } sm24tat4xbIGMPSnoopingVLANConfigQuerierAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Querier Address" ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 5 } sm24tat4xbIGMPSnoopingVLANConfigCompatibility OBJECT-TYPE SYNTAX Integer32(0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Compatibility 0:IGMP-Auto 1:Forced IGMPv1 2:Forced IGMPv2 3:Forced IGMPv3" ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 6 } sm24tat4xbIGMPSnoopingVLANConfigPRI OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority of Interface. " ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 7 } sm24tat4xbIGMPSnoopingVLANConfigRV OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Robustness Variable." ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 8 } sm24tat4xbIGMPSnoopingVLANConfigQI OBJECT-TYPE SYNTAX Integer32(1..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Query Interval." ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 9 } sm24tat4xbIGMPSnoopingVLANConfigQRI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Query Response Interval." ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 10 } sm24tat4xbIGMPSnoopingVLANConfigLLQI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Last Member Query Interval." ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 11 } sm24tat4xbIGMPSnoopingVLANConfigURI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Unsolicited Report Interval." ::= { sm24tat4xbIGMPSnoopingVLANConfigEntry 12 } sm24tat4xbIGMPSnoopingStatusClear OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Clears all Statistics counters." ::= { sm24tat4xbIGMPSnooping 10 } sm24tat4xbIGMPSnoopingStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIGMPSnoopingStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbIGMPSnooping 11 } sm24tat4xbIGMPSnoopingStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBIGMPSnoopingStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbIGMPSnoopingStatusIndex } ::= { sm24tat4xbIGMPSnoopingStatusTable 1 } SM24TAT4XBIGMPSnoopingStatusEntry ::= SEQUENCE { sm24tat4xbIGMPSnoopingStatusIndex Integer32, sm24tat4xbIGMPSnoopingStatusVLANID Integer32, sm24tat4xbIGMPSnoopingStatusQuerierVersion DisplayString, sm24tat4xbIGMPSnoopingStatusHostVersion DisplayString, sm24tat4xbIGMPSnoopingStatusQuerierStatus Integer32, sm24tat4xbIGMPSnoopingStatusQueriesTransmitted Integer32, sm24tat4xbIGMPSnoopingStatusQueriesReceived Integer32, sm24tat4xbIGMPSnoopingStatusV1ReportsReceived Integer32, sm24tat4xbIGMPSnoopingStatusV2ReportsReceived Integer32, sm24tat4xbIGMPSnoopingStatusV3ReportsReceived Integer32, sm24tat4xbIGMPSnoopingStatusV2LeavesReceived Integer32 } sm24tat4xbIGMPSnoopingStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbIGMPSnoopingStatusEntry 1 } sm24tat4xbIGMPSnoopingStatusVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbIGMPSnoopingStatusEntry 2 } sm24tat4xbIGMPSnoopingStatusQuerierVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Querier Version" ::= { sm24tat4xbIGMPSnoopingStatusEntry 3 } sm24tat4xbIGMPSnoopingStatusHostVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host Version" ::= { sm24tat4xbIGMPSnoopingStatusEntry 4 } sm24tat4xbIGMPSnoopingStatusQuerierStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Querier Status. 0:Init 1:Idle 2:Active" ::= { sm24tat4xbIGMPSnoopingStatusEntry 5 } sm24tat4xbIGMPSnoopingStatusQueriesTransmitted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Queries Transmitted." ::= { sm24tat4xbIGMPSnoopingStatusEntry 6 } sm24tat4xbIGMPSnoopingStatusQueriesReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Queries Received." ::= { sm24tat4xbIGMPSnoopingStatusEntry 7 } sm24tat4xbIGMPSnoopingStatusV1ReportsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V1 Reports Received" ::= { sm24tat4xbIGMPSnoopingStatusEntry 8 } sm24tat4xbIGMPSnoopingStatusV2ReportsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V2 Reports Received" ::= { sm24tat4xbIGMPSnoopingStatusEntry 9 } sm24tat4xbIGMPSnoopingStatusV3ReportsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V3 Reports Received" ::= { sm24tat4xbIGMPSnoopingStatusEntry 10 } sm24tat4xbIGMPSnoopingStatusV2LeavesReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V2 Leaves Received" ::= { sm24tat4xbIGMPSnoopingStatusEntry 11 } sm24tat4xbIGMPSnoopingStatusRouterPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIGMPSnoopingStatusRouterPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbIGMPSnooping 12 } sm24tat4xbIGMPSnoopingStatusRouterPortEntry OBJECT-TYPE SYNTAX SM24TAT4XBIGMPSnoopingStatusRouterPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbIGMPSnoopingStatusRouterPortIndex } ::= { sm24tat4xbIGMPSnoopingStatusRouterPortTable 1 } SM24TAT4XBIGMPSnoopingStatusRouterPortEntry ::= SEQUENCE { sm24tat4xbIGMPSnoopingStatusRouterPortIndex Integer32, sm24tat4xbIGMPSnoopingStatusRouterPortPort Integer32 } sm24tat4xbIGMPSnoopingStatusRouterPortIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbIGMPSnoopingStatusRouterPortEntry 1 } sm24tat4xbIGMPSnoopingStatusRouterPortPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Switch port number. 0:DISABLE 1:IDLE 2:ACTIVE" ::= { sm24tat4xbIGMPSnoopingStatusRouterPortEntry 2 } sm24tat4xbIGMPSnoopingGroupInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIGMPSnoopingGroupInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbIGMPSnooping 13 } sm24tat4xbIGMPSnoopingGroupInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBIGMPSnoopingGroupInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbIGMPSnoopingGroupInfoIndex } ::= { sm24tat4xbIGMPSnoopingGroupInfoTable 1 } SM24TAT4XBIGMPSnoopingGroupInfoEntry ::= SEQUENCE { sm24tat4xbIGMPSnoopingGroupInfoIndex Integer32, sm24tat4xbIGMPSnoopingGroupInfoVLANID Integer32, sm24tat4xbIGMPSnoopingGroupInfoGroups IpAddress, sm24tat4xbIGMPSnoopingGroupInfoPortMembers DisplayString } sm24tat4xbIGMPSnoopingGroupInfoIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbIGMPSnoopingGroupInfoEntry 1 } sm24tat4xbIGMPSnoopingGroupInfoVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbIGMPSnoopingGroupInfoEntry 2 } sm24tat4xbIGMPSnoopingGroupInfoGroups OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Groups" ::= { sm24tat4xbIGMPSnoopingGroupInfoEntry 3 } sm24tat4xbIGMPSnoopingGroupInfoPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Port Members" ::= { sm24tat4xbIGMPSnoopingGroupInfoEntry 4 } sm24tat4xbIGMPSFMInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIGMPSFMInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbIGMPSnooping 14 } sm24tat4xbIGMPSFMInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBIGMPSFMInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbIGMPSFMInfoIndex } ::= { sm24tat4xbIGMPSFMInfoTable 1 } SM24TAT4XBIGMPSFMInfoEntry ::= SEQUENCE { sm24tat4xbIGMPSFMInfoIndex Integer32, sm24tat4xbIGMPSFMInfoVLANID Integer32, sm24tat4xbIGMPSFMInfoGroup IpAddress, sm24tat4xbIGMPSFMInfoPort Integer32, sm24tat4xbIGMPSFMInfoMode Integer32, sm24tat4xbIGMPSFMInfoSourceAddress DisplayString, sm24tat4xbIGMPSFMInfoType Integer32, sm24tat4xbIGMPSFMInfoHardwareFilterSwitch Integer32 } sm24tat4xbIGMPSFMInfoIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbIGMPSFMInfoEntry 1 } sm24tat4xbIGMPSFMInfoVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbIGMPSFMInfoEntry 2 } sm24tat4xbIGMPSFMInfoGroup OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Group" ::= { sm24tat4xbIGMPSFMInfoEntry 3 } sm24tat4xbIGMPSFMInfoPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port" ::= { sm24tat4xbIGMPSFMInfoEntry 4 } sm24tat4xbIGMPSFMInfoMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mode 0:Exclude. 1:Include" ::= { sm24tat4xbIGMPSFMInfoEntry 5 } sm24tat4xbIGMPSFMInfoSourceAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Source Address" ::= { sm24tat4xbIGMPSFMInfoEntry 6 } sm24tat4xbIGMPSFMInfoType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Type 0:Deny 1:Allow" ::= { sm24tat4xbIGMPSFMInfoEntry 7 } sm24tat4xbIGMPSFMInfoHardwareFilterSwitch OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Filter\Switch 0:No 1:Yes" ::= { sm24tat4xbIGMPSFMInfoEntry 8 } sm24tat4xbMLDSnooping OBJECT IDENTIFIER ::= { sm24tat4xbIPMC 2 } sm24tat4xbMLDSnoopingBasicConfigSnoopingEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Snooping Enabled 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnooping 2 } sm24tat4xbMLDSnoopingUnregisteredIPMCv6FloodingEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Unregistered IPMCv6 Flooding Enabled 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnooping 3 } sm24tat4xbMLDSnoopingBasicConfigMLDSSMRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "MLD SSM Range IPv6 multicast address." ::= { sm24tat4xbMLDSnooping 4 } sm24tat4xbMLDSnoopingBasicConfigMLDSSMRangeLength OBJECT-TYPE SYNTAX Integer32(8..128) MAX-ACCESS read-write STATUS current DESCRIPTION "MLD SSM Range prefix. " ::= { sm24tat4xbMLDSnooping 5 } sm24tat4xbMLDSnoopingBasicConfigLeaveProxyEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Leave Proxy Enabled 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnooping 6 } sm24tat4xbMLDSnoopingBasicConfigProxyEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Proxy Enabled 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnooping 7 } sm24tat4xbMLDSnoopingPortRelatedTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMLDSnoopingPortRelatedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMLDSnooping 8 } sm24tat4xbMLDSnoopingPortRelatedEntry OBJECT-TYPE SYNTAX SM24TAT4XBMLDSnoopingPortRelatedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMLDSnoopingPortRelatedPort } ::= { sm24tat4xbMLDSnoopingPortRelatedTable 1 } SM24TAT4XBMLDSnoopingPortRelatedEntry ::= SEQUENCE { sm24tat4xbMLDSnoopingPortRelatedPort Integer32, sm24tat4xbMLDSnoopingPortRouterPort Integer32, sm24tat4xbMLDSnoopingPortFastLeave Integer32, sm24tat4xbMLDSnoopingPortThrottling Integer32, sm24tat4xbMLDSnoopingPortFilteringProfile DisplayString } sm24tat4xbMLDSnoopingPortRelatedPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMLDSnoopingPortRelatedEntry 1 } sm24tat4xbMLDSnoopingPortRouterPort OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Router Port 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnoopingPortRelatedEntry 2 } sm24tat4xbMLDSnoopingPortFastLeave OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Fast Leave 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnoopingPortRelatedEntry 3 } sm24tat4xbMLDSnoopingPortThrottling OBJECT-TYPE SYNTAX Integer32(0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Throttling. Range: 0:unlimited, 1-10" ::= { sm24tat4xbMLDSnoopingPortRelatedEntry 4 } sm24tat4xbMLDSnoopingPortFilteringProfile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Filtering Profile" ::= { sm24tat4xbMLDSnoopingPortRelatedEntry 5 } sm24tat4xbMLDSnoopingVLANConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMLDSnoopingVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMLDSnooping 9 } sm24tat4xbMLDSnoopingVLANConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBMLDSnoopingVLANConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMLDSnoopingVLANConfigIndex } ::= { sm24tat4xbMLDSnoopingVLANConfigTable 1 } SM24TAT4XBMLDSnoopingVLANConfigEntry ::= SEQUENCE { sm24tat4xbMLDSnoopingVLANConfigIndex Integer32, sm24tat4xbMLDSnoopingVLANConfigVLANID Integer32, sm24tat4xbMLDSnoopingVLANConfigSnoopingEnabled Integer32, sm24tat4xbMLDSnoopingVLANConfigQuerierElection Integer32, sm24tat4xbMLDSnoopingVLANConfigCompatibility Integer32, sm24tat4xbMLDSnoopingVLANConfigPRI Integer32, sm24tat4xbMLDSnoopingVLANConfigRV Integer32, sm24tat4xbMLDSnoopingVLANConfigQI Integer32, sm24tat4xbMLDSnoopingVLANConfigQRI Integer32, sm24tat4xbMLDSnoopingVLANConfigLLQI Integer32, sm24tat4xbMLDSnoopingVLANConfigURI Integer32 } sm24tat4xbMLDSnoopingVLANConfigIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 1 } sm24tat4xbMLDSnoopingVLANConfigVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 2 } sm24tat4xbMLDSnoopingVLANConfigSnoopingEnabled OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IGMP Snooping Enabled 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 3 } sm24tat4xbMLDSnoopingVLANConfigQuerierElection OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Querier Election 0:Disable 1:Enable" ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 4 } sm24tat4xbMLDSnoopingVLANConfigCompatibility OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Compatibility 0:MLD-Auto 1:Forced MLDv1 2:Forced MLDv2" ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 6 } sm24tat4xbMLDSnoopingVLANConfigPRI OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Priority of Interface. " ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 7 } sm24tat4xbMLDSnoopingVLANConfigRV OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Robustness Variable." ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 8 } sm24tat4xbMLDSnoopingVLANConfigQI OBJECT-TYPE SYNTAX Integer32(1..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Query Interval." ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 9 } sm24tat4xbMLDSnoopingVLANConfigQRI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Query Response Interval." ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 10 } sm24tat4xbMLDSnoopingVLANConfigLLQI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Last Member Query Interval." ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 11 } sm24tat4xbMLDSnoopingVLANConfigURI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-write STATUS current DESCRIPTION "Unsolicited Report Interval." ::= { sm24tat4xbMLDSnoopingVLANConfigEntry 12 } sm24tat4xbMLDSnoopingStatusClear OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Clears all Statistics counters." ::= { sm24tat4xbMLDSnooping 10 } sm24tat4xbMLDSnoopingStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMLDSnoopingStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMLDSnooping 11 } sm24tat4xbMLDSnoopingStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBMLDSnoopingStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMLDSnoopingStatusIndex } ::= { sm24tat4xbMLDSnoopingStatusTable 1 } SM24TAT4XBMLDSnoopingStatusEntry ::= SEQUENCE { sm24tat4xbMLDSnoopingStatusIndex Integer32, sm24tat4xbMLDSnoopingStatusVLANID Integer32, sm24tat4xbMLDSnoopingStatusQuerierVersion DisplayString, sm24tat4xbMLDSnoopingStatusHostVersion DisplayString, sm24tat4xbMLDSnoopingStatusQuerierStatus Integer32, sm24tat4xbMLDSnoopingStatusQueriesTransmitted Integer32, sm24tat4xbMLDSnoopingStatusQueriesReceived Integer32, sm24tat4xbMLDSnoopingStatusV1ReportsReceived Integer32, sm24tat4xbMLDSnoopingStatusV2ReportsReceived Integer32, sm24tat4xbMLDSnoopingStatusV1LeavesReceived Integer32 } sm24tat4xbMLDSnoopingStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMLDSnoopingStatusEntry 1 } sm24tat4xbMLDSnoopingStatusVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMLDSnoopingStatusEntry 2 } sm24tat4xbMLDSnoopingStatusQuerierVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Querier Version" ::= { sm24tat4xbMLDSnoopingStatusEntry 3 } sm24tat4xbMLDSnoopingStatusHostVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Host Version" ::= { sm24tat4xbMLDSnoopingStatusEntry 4 } sm24tat4xbMLDSnoopingStatusQuerierStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Querier Status. 0:Init 1:Idle 2:Active" ::= { sm24tat4xbMLDSnoopingStatusEntry 5 } sm24tat4xbMLDSnoopingStatusQueriesTransmitted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Queries Transmitted." ::= { sm24tat4xbMLDSnoopingStatusEntry 6 } sm24tat4xbMLDSnoopingStatusQueriesReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Queries Received." ::= { sm24tat4xbMLDSnoopingStatusEntry 7 } sm24tat4xbMLDSnoopingStatusV1ReportsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V1 Reports Received" ::= { sm24tat4xbMLDSnoopingStatusEntry 8 } sm24tat4xbMLDSnoopingStatusV2ReportsReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V2 Reports Received" ::= { sm24tat4xbMLDSnoopingStatusEntry 9 } sm24tat4xbMLDSnoopingStatusV1LeavesReceived OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "V1 Leaves Received" ::= { sm24tat4xbMLDSnoopingStatusEntry 11 } sm24tat4xbMLDSnoopingStatusRouterPortTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMLDSnoopingStatusRouterPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMLDSnooping 12 } sm24tat4xbMLDSnoopingStatusRouterPortEntry OBJECT-TYPE SYNTAX SM24TAT4XBMLDSnoopingStatusRouterPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMLDSnoopingStatusRouterPortIndex } ::= { sm24tat4xbMLDSnoopingStatusRouterPortTable 1 } SM24TAT4XBMLDSnoopingStatusRouterPortEntry ::= SEQUENCE { sm24tat4xbMLDSnoopingStatusRouterPortIndex Integer32, sm24tat4xbMLDSnoopingStatusRouterPortPort Integer32 } sm24tat4xbMLDSnoopingStatusRouterPortIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMLDSnoopingStatusRouterPortEntry 1 } sm24tat4xbMLDSnoopingStatusRouterPortPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Switch port number. 0:DISABLE 1:IDLE 2:ACTIVE" ::= { sm24tat4xbMLDSnoopingStatusRouterPortEntry 2 } sm24tat4xbMLDSnoopingGroupInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMLDSnoopingGroupInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMLDSnooping 13 } sm24tat4xbMLDSnoopingGroupInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBMLDSnoopingGroupInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMLDSnoopingGroupInfoIndex } ::= { sm24tat4xbMLDSnoopingGroupInfoTable 1 } SM24TAT4XBMLDSnoopingGroupInfoEntry ::= SEQUENCE { sm24tat4xbMLDSnoopingGroupInfoIndex Integer32, sm24tat4xbMLDSnoopingGroupInfoVLANID Integer32, sm24tat4xbMLDSnoopingGroupInfoGroups IpAddress, sm24tat4xbMLDSnoopingGroupInfoPortMembers DisplayString } sm24tat4xbMLDSnoopingGroupInfoIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMLDSnoopingGroupInfoEntry 1 } sm24tat4xbMLDSnoopingGroupInfoVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMLDSnoopingGroupInfoEntry 2 } sm24tat4xbMLDSnoopingGroupInfoGroups OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Groups" ::= { sm24tat4xbMLDSnoopingGroupInfoEntry 3 } sm24tat4xbMLDSnoopingGroupInfoPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Port Members" ::= { sm24tat4xbMLDSnoopingGroupInfoEntry 4 } sm24tat4xbMLDSFMInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMLDSFMInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMLDSnooping 14 } sm24tat4xbMLDSFMInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBMLDSFMInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMLDSFMInfoIndex } ::= { sm24tat4xbMLDSFMInfoTable 1 } SM24TAT4XBMLDSFMInfoEntry ::= SEQUENCE { sm24tat4xbMLDSFMInfoIndex Integer32, sm24tat4xbMLDSFMInfoVLANID Integer32, sm24tat4xbMLDSFMInfoGroup IpAddress, sm24tat4xbMLDSFMInfoPort Integer32, sm24tat4xbMLDSFMInfoMode Integer32, sm24tat4xbMLDSFMInfoSourceAddress DisplayString, sm24tat4xbMLDSFMInfoType Integer32, sm24tat4xbMLDSFMInfoHardwareFilterSwitch Integer32 } sm24tat4xbMLDSFMInfoIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMLDSFMInfoEntry 1 } sm24tat4xbMLDSFMInfoVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMLDSFMInfoEntry 2 } sm24tat4xbMLDSFMInfoGroup OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Group" ::= { sm24tat4xbMLDSFMInfoEntry 3 } sm24tat4xbMLDSFMInfoPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port" ::= { sm24tat4xbMLDSFMInfoEntry 4 } sm24tat4xbMLDSFMInfoMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mode 0:Exclude. 1:Include" ::= { sm24tat4xbMLDSFMInfoEntry 5 } sm24tat4xbMLDSFMInfoSourceAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Source Address" ::= { sm24tat4xbMLDSFMInfoEntry 6 } sm24tat4xbMLDSFMInfoType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Type 0:Deny 1:Allow" ::= { sm24tat4xbMLDSFMInfoEntry 7 } sm24tat4xbMLDSFMInfoHardwareFilterSwitch OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Filter\Switch 0:No 1:Yes" ::= { sm24tat4xbMLDSFMInfoEntry 8 } sm24tat4xbMVR OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 33 } sm24tat4xbMVRConfig OBJECT IDENTIFIER ::= { sm24tat4xbMVR 1 } sm24tat4xbMVRConfigMVRMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "MVR Mode 0:Disable 1:Enable" ::= { sm24tat4xbMVRConfig 2 } sm24tat4xbVLANInterfaceSettingTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANInterfaceSettingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MVR Config table" ::= { sm24tat4xbMVRConfig 3 } sm24tat4xbVLANInterfaceSettingEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANInterfaceSettingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MVR Config table" INDEX { sm24tat4xbVLANInterfaceSettingIndex } ::= { sm24tat4xbVLANInterfaceSettingTable 1 } SM24TAT4XBVLANInterfaceSettingEntry ::= SEQUENCE { sm24tat4xbVLANInterfaceSettingIndex Integer32, sm24tat4xbVLANInterfaceSettingMVRVID Integer32, sm24tat4xbVLANInterfaceSettingMVRName DisplayString, sm24tat4xbVLANInterfaceSettingIGMPAddress IpAddress, sm24tat4xbVLANInterfaceSettingMode Integer32, sm24tat4xbVLANInterfaceSettingTagging Integer32, sm24tat4xbVLANInterfaceSettingPriority Integer32, sm24tat4xbVLANInterfaceSettingLLQI Integer32, sm24tat4xbVLANInterfaceSettingInterfaceChannelProfile DisplayString, sm24tat4xbVLANInterfaceSettingRowStatus RowStatus } sm24tat4xbVLANInterfaceSettingIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "MVR Config index." ::= {sm24tat4xbVLANInterfaceSettingEntry 1 } sm24tat4xbVLANInterfaceSettingMVRVID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "MVR VLAN ID" ::= {sm24tat4xbVLANInterfaceSettingEntry 2 } sm24tat4xbVLANInterfaceSettingMVRName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "MVR Name. Length:0-16" ::= {sm24tat4xbVLANInterfaceSettingEntry 3 } sm24tat4xbVLANInterfaceSettingIGMPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IPv4 IGMP Address" ::= {sm24tat4xbVLANInterfaceSettingEntry 4 } sm24tat4xbVLANInterfaceSettingMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Mode. 0:Dynamic 1:Compatible" ::= {sm24tat4xbVLANInterfaceSettingEntry 5 } sm24tat4xbVLANInterfaceSettingTagging OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Tagging. 0:Untagged 1:Tagged" ::= {sm24tat4xbVLANInterfaceSettingEntry 6 } sm24tat4xbVLANInterfaceSettingPriority OBJECT-TYPE SYNTAX Integer32(0..7) MAX-ACCESS read-create STATUS current DESCRIPTION "Priority" ::= {sm24tat4xbVLANInterfaceSettingEntry 7 } sm24tat4xbVLANInterfaceSettingLLQI OBJECT-TYPE SYNTAX Integer32(0..31744) MAX-ACCESS read-create STATUS current DESCRIPTION "LLQI" ::= {sm24tat4xbVLANInterfaceSettingEntry 8 } sm24tat4xbVLANInterfaceSettingInterfaceChannelProfile OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Interface Channel Profile." ::= {sm24tat4xbVLANInterfaceSettingEntry 9 } sm24tat4xbVLANInterfaceSettingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbVLANInterfaceSettingEntry 10 } sm24tat4xbMVRVIDIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Set VIDIndex before use VLANInterfaceSettingPortRoleTable table." ::= { sm24tat4xbMVRConfig 4 } sm24tat4xbVLANInterfaceSettingPortRoleTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBVLANInterfaceSettingPortRoleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN Interface Setting Port Role table" ::= { sm24tat4xbMVRConfig 5 } sm24tat4xbVLANInterfaceSettingPortRoleEntry OBJECT-TYPE SYNTAX SM24TAT4XBVLANInterfaceSettingPortRoleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN Interface Setting Port Role table" INDEX { sm24tat4xbVLANInterfaceSettingPortRoleIndex } ::= { sm24tat4xbVLANInterfaceSettingPortRoleTable 1 } SM24TAT4XBVLANInterfaceSettingPortRoleEntry ::= SEQUENCE { sm24tat4xbVLANInterfaceSettingPortRoleIndex Integer32, sm24tat4xbVLANInterfaceSettingPortRolePort Integer32 } sm24tat4xbVLANInterfaceSettingPortRoleIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "VLAN Interface Setting Port Role index." ::= {sm24tat4xbVLANInterfaceSettingPortRoleEntry 1 } sm24tat4xbVLANInterfaceSettingPortRolePort OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Port Role. 0:Inactive 1:Source 2:Receiver" ::= {sm24tat4xbVLANInterfaceSettingPortRoleEntry 2 } sm24tat4xbImmediateLeaveSettingTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBImmediateLeaveSettingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Immediate Leave Setting table" ::= { sm24tat4xbMVRConfig 6 } sm24tat4xbImmediateLeaveSettingEntry OBJECT-TYPE SYNTAX SM24TAT4XBImmediateLeaveSettingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Immediate Leave Setting table" INDEX { sm24tat4xbImmediateLeaveSettingPort } ::= { sm24tat4xbImmediateLeaveSettingTable 1 } SM24TAT4XBImmediateLeaveSettingEntry ::= SEQUENCE { sm24tat4xbImmediateLeaveSettingPort Integer32, sm24tat4xbImmediateLeaveSettingImmediateLeave Integer32 } sm24tat4xbImmediateLeaveSettingPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Immediate Leave Setting index." ::= {sm24tat4xbImmediateLeaveSettingEntry 1 } sm24tat4xbImmediateLeaveSettingImmediateLeave OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Immediate Leave 0:Disable 1:Enable" ::= {sm24tat4xbImmediateLeaveSettingEntry 2 } sm24tat4xbStatistics OBJECT IDENTIFIER ::= { sm24tat4xbMVR 2 } sm24tat4xbMVRStatisticsClear OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Statistics Clear. 1:Clear" ::= { sm24tat4xbStatistics 2 } sm24tat4xbMVRStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMVRStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbStatistics 3 } sm24tat4xbMVRStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBMVRStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMVRStatisticsIndex } ::= { sm24tat4xbMVRStatisticsTable 1 } SM24TAT4XBMVRStatisticsEntry ::= SEQUENCE { sm24tat4xbMVRStatisticsIndex Integer32, sm24tat4xbMVRStatisticsVLANID Integer32, sm24tat4xbMVRStatisticsIGMPMLDQueriesReceived DisplayString, sm24tat4xbMVRStatisticsIGMPMLDQueriesTransmitted DisplayString, sm24tat4xbMVRStatisticsIGMPv1JoinsReceived DisplayString, sm24tat4xbMVRStatisticsIGMPv2MLDv1ReportsReceived DisplayString, sm24tat4xbMVRStatisticsIGMPv3MLDv2ReportsReceived DisplayString, sm24tat4xbMVRStatisticsIGMPv2MLDv1LeavesReceived DisplayString } sm24tat4xbMVRStatisticsIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMVRStatisticsEntry 1 } sm24tat4xbMVRStatisticsVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMVRStatisticsEntry 2 } sm24tat4xbMVRStatisticsIGMPMLDQueriesReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IGMP/MLD Queries Received" ::= { sm24tat4xbMVRStatisticsEntry 3 } sm24tat4xbMVRStatisticsIGMPMLDQueriesTransmitted OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IGMP/MLD Queries Transmitted" ::= { sm24tat4xbMVRStatisticsEntry 4 } sm24tat4xbMVRStatisticsIGMPv1JoinsReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IGMPv1 Joins Received" ::= { sm24tat4xbMVRStatisticsEntry 5 } sm24tat4xbMVRStatisticsIGMPv2MLDv1ReportsReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IGMPv2/MLDv1 Reports Received" ::= { sm24tat4xbMVRStatisticsEntry 6 } sm24tat4xbMVRStatisticsIGMPv3MLDv2ReportsReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IGMPv3/MLDv2 Reports Received" ::= { sm24tat4xbMVRStatisticsEntry 7 } sm24tat4xbMVRStatisticsIGMPv2MLDv1LeavesReceived OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IGMPv2/MLDv1 Leaves Received" ::= { sm24tat4xbMVRStatisticsEntry 8 } sm24tat4xbGroupInformation OBJECT IDENTIFIER ::= { sm24tat4xbMVR 3 } sm24tat4xbMVRGroupInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMVRGroupInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbGroupInformation 1 } sm24tat4xbMVRGroupInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBMVRGroupInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMVRGroupInfoIndex } ::= { sm24tat4xbMVRGroupInfoTable 1 } SM24TAT4XBMVRGroupInfoEntry ::= SEQUENCE { sm24tat4xbMVRGroupInfoIndex Integer32, sm24tat4xbMVRGroupInfoVLANID Integer32, sm24tat4xbMVRGroupInfoGroups DisplayString, sm24tat4xbMVRGroupInfoPortMembers DisplayString } sm24tat4xbMVRGroupInfoIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMVRGroupInfoEntry 1 } sm24tat4xbMVRGroupInfoVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMVRGroupInfoEntry 2 } sm24tat4xbMVRGroupInfoGroups OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Groups" ::= { sm24tat4xbMVRGroupInfoEntry 3 } sm24tat4xbMVRGroupInfoPortMembers OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Port Members" ::= { sm24tat4xbMVRGroupInfoEntry 4 } sm24tat4xbMVRSFMInformation OBJECT IDENTIFIER ::= { sm24tat4xbMVR 4 } sm24tat4xbMVRSFMInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMVRSFMInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbMVRSFMInformation 2 } sm24tat4xbMVRSFMInfoEntry OBJECT-TYPE SYNTAX SM24TAT4XBMVRSFMInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbMVRSFMInfoIndex } ::= { sm24tat4xbMVRSFMInfoTable 1 } SM24TAT4XBMVRSFMInfoEntry ::= SEQUENCE { sm24tat4xbMVRSFMInfoIndex Integer32, sm24tat4xbMVRSFMInfoVLANID Integer32, sm24tat4xbMVRSFMInfoGroup DisplayString, sm24tat4xbMVRSFMInfoPort Integer32, sm24tat4xbMVRSFMInfoMode Integer32, sm24tat4xbMVRSFMInfoSourceAddress DisplayString, sm24tat4xbMVRSFMInfoType Integer32, sm24tat4xbMVRSFMInfoHardwareFilterSwitch Integer32 } sm24tat4xbMVRSFMInfoIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbMVRSFMInfoEntry 1 } sm24tat4xbMVRSFMInfoVLANID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID" ::= { sm24tat4xbMVRSFMInfoEntry 2 } sm24tat4xbMVRSFMInfoGroup OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Group" ::= { sm24tat4xbMVRSFMInfoEntry 3 } sm24tat4xbMVRSFMInfoPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Port" ::= { sm24tat4xbMVRSFMInfoEntry 4 } sm24tat4xbMVRSFMInfoMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Mode 0:Exclude. 1:Include" ::= { sm24tat4xbMVRSFMInfoEntry 5 } sm24tat4xbMVRSFMInfoSourceAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Source Address" ::= { sm24tat4xbMVRSFMInfoEntry 6 } sm24tat4xbMVRSFMInfoType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Type 0:Deny 1:Allow" ::= { sm24tat4xbMVRSFMInfoEntry 7 } sm24tat4xbMVRSFMInfoHardwareFilterSwitch OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Filter\Switch 0:No 1:Yes" ::= { sm24tat4xbMVRSFMInfoEntry 8 } sm24tat4xbIPMCLIB OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 34 } sm24tat4xbMulticastFilteringProfileMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Multicast Filtering Profile Mode. 0:Disable 1:Enable" ::= { sm24tat4xbIPMCLIB 1 } sm24tat4xbMulticastFilteringProfileSettingTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMulticastFilteringProfileSettingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Setting table" ::= { sm24tat4xbIPMCLIB 2 } sm24tat4xbMulticastFilteringProfileSettingEntry OBJECT-TYPE SYNTAX SM24TAT4XBMulticastFilteringProfileSettingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Setting table." INDEX { sm24tat4xbMulticastFilteringProfileSettingIndex } ::= { sm24tat4xbMulticastFilteringProfileSettingTable 1 } SM24TAT4XBMulticastFilteringProfileSettingEntry ::= SEQUENCE { sm24tat4xbMulticastFilteringProfileSettingIndex Integer32, sm24tat4xbMulticastFilteringProfileSettingProfileName DisplayString, sm24tat4xbMulticastFilteringProfileSettingProfileDescription DisplayString, sm24tat4xbMulticastFilteringProfileSettingRowStatus RowStatus } sm24tat4xbMulticastFilteringProfileSettingIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Setting index." ::= {sm24tat4xbMulticastFilteringProfileSettingEntry 1 } sm24tat4xbMulticastFilteringProfileSettingProfileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Profile Name. Length:1-16" ::= {sm24tat4xbMulticastFilteringProfileSettingEntry 2 } sm24tat4xbMulticastFilteringProfileSettingProfileDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Profile Description. Length:0-64" ::= {sm24tat4xbMulticastFilteringProfileSettingEntry 3 } sm24tat4xbMulticastFilteringProfileSettingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbMulticastFilteringProfileSettingEntry 4 } sm24tat4xbMulticastFilterProfRuleSettingsProfileNameIndex OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Set this Profile Name value before use MulticastFilteringProfileRuleSettingsTable table" ::= { sm24tat4xbIPMCLIB 3 } sm24tat4xbMulticastFilteringProfileRuleSettingsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMulticastFilteringProfileRuleSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Rule Setting table" ::= { sm24tat4xbIPMCLIB 4 } sm24tat4xbMulticastFilteringProfileRuleSettingsEntry OBJECT-TYPE SYNTAX SM24TAT4XBMulticastFilteringProfileRuleSettingsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Rule Setting table." INDEX { sm24tat4xbMulticastFilteringProfileRuleSettingsIndex } ::= { sm24tat4xbMulticastFilteringProfileRuleSettingsTable 1 } SM24TAT4XBMulticastFilteringProfileRuleSettingsEntry ::= SEQUENCE { sm24tat4xbMulticastFilteringProfileRuleSettingsTableIndex Integer32, sm24tat4xbMulticastFilteringProfileRuleSettingsProfileName DisplayString, sm24tat4xbMulticastFilteringProfileRuleSettingsIndex Integer32, sm24tat4xbMulticastFilteringProfileRuleSettingsEntryName DisplayString, sm24tat4xbMulticastFilteringProfileRuleSettingsAddressRange DisplayString, sm24tat4xbMulticastFilteringProfileRuleSettingsAction Integer32, sm24tat4xbMulticastFilteringProfileRuleSettingsLog Integer32, sm24tat4xbMulticastFilteringProfileRuleSettingsRowStatus RowStatus } sm24tat4xbMulticastFilteringProfileRuleSettingsTableIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Rule Setting index." ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 1 } sm24tat4xbMulticastFilteringProfileRuleSettingsProfileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Profile Name" ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 2 } sm24tat4xbMulticastFilteringProfileRuleSettingsIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Index" ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 3 } sm24tat4xbMulticastFilteringProfileRuleSettingsEntryName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Entry Name, Length: 1-16" ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 4 } sm24tat4xbMulticastFilteringProfileRuleSettingsAddressRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Address Range" ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 5 } sm24tat4xbMulticastFilteringProfileRuleSettingsAction OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "0:Deny 1:Permit" ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 6 } sm24tat4xbMulticastFilteringProfileRuleSettingsLog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "0:Disable 1:Enable" ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 7 } sm24tat4xbMulticastFilteringProfileRuleSettingsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbMulticastFilteringProfileRuleSettingsEntry 8 } sm24tat4xbMulticastFilteringProfileAddressConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBMulticastFilteringProfileAddressConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Address Config table" ::= { sm24tat4xbIPMCLIB 5 } sm24tat4xbMulticastFilteringProfileAddressConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBMulticastFilteringProfileAddressConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Address Config table." INDEX { sm24tat4xbMulticastFilteringProfileAddressConfigTableIndex } ::= { sm24tat4xbMulticastFilteringProfileAddressConfigTable 1 } SM24TAT4XBMulticastFilteringProfileAddressConfigEntry ::= SEQUENCE { sm24tat4xbMulticastFilteringProfileAddressConfigTableIndex Integer32, sm24tat4xbMulticastFilteringProfileAddressConfigEntryName DisplayString, sm24tat4xbMulticastFilteringProfileAddressConfigStartAddress DisplayString, sm24tat4xbMulticastFilteringProfileAddressConfigEndAddress DisplayString, sm24tat4xbMulticastFilteringProfileAddressConfigRowStatus RowStatus } sm24tat4xbMulticastFilteringProfileAddressConfigTableIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Multicast Filtering Profile Address Config index." ::= {sm24tat4xbMulticastFilteringProfileAddressConfigEntry 1 } sm24tat4xbMulticastFilteringProfileAddressConfigEntryName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Entry Name, Length: 1-16" ::= {sm24tat4xbMulticastFilteringProfileAddressConfigEntry 2 } sm24tat4xbMulticastFilteringProfileAddressConfigStartAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IPv4/IPv6 Multicast Group Address" ::= {sm24tat4xbMulticastFilteringProfileAddressConfigEntry 3 } sm24tat4xbMulticastFilteringProfileAddressConfigEndAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "IPv4/IPv6 Multicast Group Address" ::= {sm24tat4xbMulticastFilteringProfileAddressConfigEntry 4 } sm24tat4xbMulticastFilteringProfileAddressConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row Status." ::= {sm24tat4xbMulticastFilteringProfileAddressConfigEntry 5 } sm24tat4xbEEE OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 35 } sm24tat4xbPortPowerSavings OBJECT IDENTIFIER ::= { sm24tat4xbEEE 1 } sm24tat4xbEnergyEfficientEthernetConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBEnergyEfficientEthernetConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortPowerSavings 2 } sm24tat4xbEnergyEfficientEthernetConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBEnergyEfficientEthernetConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbEnergyEfficientEthernetConfigPort } ::= { sm24tat4xbEnergyEfficientEthernetConfigTable 1 } SM24TAT4XBEnergyEfficientEthernetConfigEntry ::= SEQUENCE { sm24tat4xbEnergyEfficientEthernetConfigPort Integer32, sm24tat4xbEnergyEfficientEthernetConfigPortConfig Integer32 } sm24tat4xbEnergyEfficientEthernetConfigPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index" ::= { sm24tat4xbEnergyEfficientEthernetConfigEntry 1 } sm24tat4xbEnergyEfficientEthernetConfigPortConfig OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether EEE is enabled for this port. 0:Disable 1:Enable" ::= { sm24tat4xbEnergyEfficientEthernetConfigEntry 2 } -- ======================================================================================================================= sm24tat4xbAggregation OBJECT IDENTIFIER ::= { sm24tat4xbConfiguration 36 } sm24tat4xbAggregationStatic OBJECT IDENTIFIER ::= { sm24tat4xbAggregation 1 } sm24tat4xbAggrSourceMACAddress OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Source MAC Address" ::= { sm24tat4xbAggregationStatic 2 } sm24tat4xbAggrDestinationMACAddress OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Destination MAC Address" ::= { sm24tat4xbAggregationStatic 3 } sm24tat4xbAggrIPAddress OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "IP Address" ::= { sm24tat4xbAggregationStatic 4 } sm24tat4xbAggrTCPUDPPortNumber OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "TCP/UDP Port Number" ::= { sm24tat4xbAggregationStatic 5 } sm24tat4xbAggrGroupConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBAggrGroupConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbAggregationStatic 6 } sm24tat4xbAggrGroupConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBAggrGroupConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbAggrGroupConfigPort } ::= { sm24tat4xbAggrGroupConfigTable 1 } SM24TAT4XBAggrGroupConfigEntry ::= SEQUENCE { sm24tat4xbAggrGroupConfigPort Integer32, sm24tat4xbAggrGroupConfigGroup Integer32, sm24tat4xbAggrGroupConfig Integer32 } sm24tat4xbAggrGroupConfigPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "port index" ::= { sm24tat4xbAggrGroupConfigEntry 1 } sm24tat4xbAggrGroupConfigGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "group index" ::= { sm24tat4xbAggrGroupConfigEntry 2 } sm24tat4xbAggrGroupConfig OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Aggregation Group Configuration" ::= { sm24tat4xbAggrGroupConfigEntry 3 } sm24tat4xbLACPConfiguration OBJECT IDENTIFIER ::= { sm24tat4xbAggregation 2 } sm24tat4xbLACPPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLACPPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLACPConfiguration 1 } sm24tat4xbLACPPortConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBLACPPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLACPPortConfigPort } ::= { sm24tat4xbLACPPortConfigTable 1 } SM24TAT4XBLACPPortConfigEntry ::= SEQUENCE { sm24tat4xbLACPPortConfigPort Integer32, sm24tat4xbLACPPortConfigEnabled Integer32, sm24tat4xbLACPPortConfigKey Integer32, sm24tat4xbLACPPortConfigRole Integer32, sm24tat4xbLACPPortConfigTimeout Integer32, sm24tat4xbLACPPortConfigPrio Integer32 } sm24tat4xbLACPPortConfigPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "port index" ::= { sm24tat4xbLACPPortConfigEntry 1 } sm24tat4xbLACPPortConfigEnabled OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether LACP is enabled on this switch port. 0:Disable 1:Enable" ::= { sm24tat4xbLACPPortConfigEntry 2 } sm24tat4xbLACPPortConfigKey OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Key value incurred by the port, range 1-Number of link aggregations. 0:autokey." ::= { sm24tat4xbLACPPortConfigEntry 3 } sm24tat4xbLACPPortConfigRole OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "The Role shows the LACP activity status. 0:Passive 1:Active" ::= { sm24tat4xbLACPPortConfigEntry 4 } sm24tat4xbLACPPortConfigTimeout OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "The Timeout controls the period between BPDU transmissions. 0:Slow 1:Fast" ::= { sm24tat4xbLACPPortConfigEntry 5 } sm24tat4xbLACPPortConfigPrio OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The Prio controls the priority of the port." ::= { sm24tat4xbLACPPortConfigEntry 6 } sm24tat4xbLacpSystemStatus OBJECT IDENTIFIER ::= { sm24tat4xbAggregation 3 } sm24tat4xbLacpSystemStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLacpSystemStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLacpSystemStatus 1 } sm24tat4xbLacpSystemStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBLacpSystemStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLacpSystemStatusIndex } ::= { sm24tat4xbLacpSystemStatusTable 1 } SM24TAT4XBLacpSystemStatusEntry ::= SEQUENCE { sm24tat4xbLacpSystemStatusIndex Integer32, sm24tat4xbLacpSystemStatusAggrID DisplayString, sm24tat4xbLacpSystemStatusPartnerSystemID DisplayString, sm24tat4xbLacpSystemStatusPartnerKey DisplayString, sm24tat4xbLacpSystemStatusPartnerPrio DisplayString, sm24tat4xbLacpSystemStatusLastChanged DisplayString, sm24tat4xbLacpSystemStatusLocalPorts DisplayString } sm24tat4xbLacpSystemStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "index" ::= { sm24tat4xbLacpSystemStatusEntry 1 } sm24tat4xbLacpSystemStatusAggrID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Aggregation ID associated with this aggregation instance." ::= { sm24tat4xbLacpSystemStatusEntry 2 } sm24tat4xbLacpSystemStatusPartnerSystemID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system ID (MAC address) of the aggregation partner." ::= { sm24tat4xbLacpSystemStatusEntry 3 } sm24tat4xbLacpSystemStatusPartnerKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Key that the partner has assigned to this aggregation ID." ::= { sm24tat4xbLacpSystemStatusEntry 4 } sm24tat4xbLacpSystemStatusPartnerPrio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The priority that the partner has assigned to this aggregation ID." ::= { sm24tat4xbLacpSystemStatusEntry 5 } sm24tat4xbLacpSystemStatusLastChanged OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time since this aggregation changed." ::= { sm24tat4xbLacpSystemStatusEntry 6 } sm24tat4xbLacpSystemStatusLocalPorts OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows which ports are a part of this aggregation for this switch." ::= { sm24tat4xbLacpSystemStatusEntry 7 } sm24tat4xbLACPInternalPortStatus OBJECT IDENTIFIER ::= { sm24tat4xbAggregation 4 } sm24tat4xbLACPInternalPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLACPInternalPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLACPInternalPortStatus 1 } sm24tat4xbLACPInternalPortStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBLACPInternalPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLACPInternalPortStatusIndex } ::= { sm24tat4xbLACPInternalPortStatusTable 1 } SM24TAT4XBLACPInternalPortStatusEntry ::= SEQUENCE { sm24tat4xbLACPInternalPortStatusIndex Integer32, sm24tat4xbLACPInternalPortStatusPort DisplayString, sm24tat4xbLACPInternalPortStatusState DisplayString, sm24tat4xbLACPInternalPortStatusKey DisplayString, sm24tat4xbLACPInternalPortStatusPriority DisplayString, sm24tat4xbLACPInternalPortStatusActivity DisplayString, sm24tat4xbLACPInternalPortStatusTimeout DisplayString, sm24tat4xbLACPInternalPortStatusAggregation DisplayString, sm24tat4xbLACPInternalPortStatusSynchronization DisplayString, sm24tat4xbLACPInternalPortStatusCollecting DisplayString, sm24tat4xbLACPInternalPortStatusDistributing DisplayString, sm24tat4xbLACPInternalPortStatusDefaulted DisplayString, sm24tat4xbLACPInternalPortStatusExpired DisplayString } sm24tat4xbLACPInternalPortStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "index" ::= { sm24tat4xbLACPInternalPortStatusEntry 1 } sm24tat4xbLACPInternalPortStatusPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The switch port number." ::= { sm24tat4xbLACPInternalPortStatusEntry 2 } sm24tat4xbLACPInternalPortStatusState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current port state: Down: The port is not active. Active: The port is in active state. Standby: The port is in standby state." ::= { sm24tat4xbLACPInternalPortStatusEntry 3 } sm24tat4xbLACPInternalPortStatusKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The key assigned to this port. Only ports with the same key can aggregate together." ::= { sm24tat4xbLACPInternalPortStatusEntry 4 } sm24tat4xbLACPInternalPortStatusPriority OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The priority assigned to this aggregation group." ::= { sm24tat4xbLACPInternalPortStatusEntry 5 } sm24tat4xbLACPInternalPortStatusActivity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The LACP mode of the group (Active or Passive)." ::= { sm24tat4xbLACPInternalPortStatusEntry 6 } sm24tat4xbLACPInternalPortStatusTimeout OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The timeout mode configured for the port (Fast or Slow)." ::= { sm24tat4xbLACPInternalPortStatusEntry 7 } sm24tat4xbLACPInternalPortStatusAggregation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show whether the system considers this link to be aggregateable. i.e., a potential candidate for aggregation." ::= { sm24tat4xbLACPInternalPortStatusEntry 8 } sm24tat4xbLACPInternalPortStatusSynchronization OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show whether the system considers this link to be IN_SYNC." ::= { sm24tat4xbLACPInternalPortStatusEntry 9 } sm24tat4xbLACPInternalPortStatusCollecting OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if collection of incoming frames on this link is enabled." ::= { sm24tat4xbLACPInternalPortStatusEntry 10 } sm24tat4xbLACPInternalPortStatusDistributing OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if distribution of outgoing frames on this link is enabled." ::= { sm24tat4xbLACPInternalPortStatusEntry 11 } sm24tat4xbLACPInternalPortStatusDefaulted OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if the Actor's Receive machine is using Defaulted operational Partner information." ::= { sm24tat4xbLACPInternalPortStatusEntry 12 } sm24tat4xbLACPInternalPortStatusExpired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if that the Actor's Receive machine is in the EXPIRED state." ::= { sm24tat4xbLACPInternalPortStatusEntry 13 } sm24tat4xbLACPNeighborPortStatus OBJECT IDENTIFIER ::= { sm24tat4xbAggregation 5 } sm24tat4xbLACPNeighborPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLACPNeighborPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLACPNeighborPortStatus 1 } sm24tat4xbLACPNeighborPortStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBLACPNeighborPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLACPNeighborPortStatusIndex } ::= { sm24tat4xbLACPNeighborPortStatusTable 1 } SM24TAT4XBLACPNeighborPortStatusEntry ::= SEQUENCE { sm24tat4xbLACPNeighborPortStatusIndex Integer32, sm24tat4xbLACPNeighborPortStatusPort DisplayString, sm24tat4xbLACPNeighborPortStatusState DisplayString, sm24tat4xbLACPNeighborPortStatusAggrID DisplayString, sm24tat4xbLACPNeighborPortStatusPartnerKey DisplayString, sm24tat4xbLACPNeighborPortStatusPartnerPort DisplayString, sm24tat4xbLACPNeighborPortStatusPartnerPortPrio DisplayString, sm24tat4xbLACPNeighborPortStatusActivity DisplayString, sm24tat4xbLACPNeighborPortStatusTimeout DisplayString, sm24tat4xbLACPNeighborPortStatusAggregation DisplayString, sm24tat4xbLACPNeighborPortStatusSynchronization DisplayString, sm24tat4xbLACPNeighborPortStatusCollecting DisplayString, sm24tat4xbLACPNeighborPortStatusDistributing DisplayString, sm24tat4xbLACPNeighborPortStatusDefaulted DisplayString, sm24tat4xbLACPNeighborPortStatusExpired DisplayString } sm24tat4xbLACPNeighborPortStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "index" ::= { sm24tat4xbLACPNeighborPortStatusEntry 1 } sm24tat4xbLACPNeighborPortStatusPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The switch port number." ::= { sm24tat4xbLACPNeighborPortStatusEntry 2 } sm24tat4xbLACPNeighborPortStatusState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The current port state: Down: The port is not active. Active: The port is in active state. Standby: The port is in standby state." ::= { sm24tat4xbLACPNeighborPortStatusEntry 3 } sm24tat4xbLACPNeighborPortStatusAggrID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The aggregation group ID which the port is assigned to." ::= { sm24tat4xbLACPNeighborPortStatusEntry 4 } sm24tat4xbLACPNeighborPortStatusPartnerKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The key assigned to this port by the partner." ::= { sm24tat4xbLACPNeighborPortStatusEntry 5 } sm24tat4xbLACPNeighborPortStatusPartnerPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The partner port number associated with this link." ::= { sm24tat4xbLACPNeighborPortStatusEntry 6 } sm24tat4xbLACPNeighborPortStatusPartnerPortPrio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The priority assigned to this partner port ." ::= { sm24tat4xbLACPNeighborPortStatusEntry 7 } sm24tat4xbLACPNeighborPortStatusActivity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The LACP mode of the group (Active or Passive)." ::= { sm24tat4xbLACPNeighborPortStatusEntry 8 } sm24tat4xbLACPNeighborPortStatusTimeout OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The timeout mode configured for the partner port (Fast or Slow)." ::= { sm24tat4xbLACPNeighborPortStatusEntry 9 } sm24tat4xbLACPNeighborPortStatusAggregation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show whether the partner considers this link to be aggregateable." ::= { sm24tat4xbLACPNeighborPortStatusEntry 10 } sm24tat4xbLACPNeighborPortStatusSynchronization OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show whether the partner considers this link to be IN_SYNC" ::= { sm24tat4xbLACPNeighborPortStatusEntry 11 } sm24tat4xbLACPNeighborPortStatusCollecting OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if collection of incoming frames on this link is enabled." ::= { sm24tat4xbLACPNeighborPortStatusEntry 12 } sm24tat4xbLACPNeighborPortStatusDistributing OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if distribution of outgoing frames on this link is enabled." ::= { sm24tat4xbLACPNeighborPortStatusEntry 13 } sm24tat4xbLACPNeighborPortStatusDefaulted OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if the partners Receive machine is using Defaulted operational Partner information." ::= { sm24tat4xbLACPNeighborPortStatusEntry 14 } sm24tat4xbLACPNeighborPortStatusExpired OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Show if that the partners Receive machine is in the EXPIRED state." ::= { sm24tat4xbLACPNeighborPortStatusEntry 15 } sm24tat4xbLACPStatus OBJECT IDENTIFIER ::= { sm24tat4xbAggregation 6 } sm24tat4xbLACPStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBLACPStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbLACPStatus 1 } sm24tat4xbLACPStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBLACPStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbLACPStatusPort } ::= { sm24tat4xbLACPStatusTable 1 } SM24TAT4XBLACPStatusEntry ::= SEQUENCE { sm24tat4xbLACPStatusPort Integer32, sm24tat4xbLACPStatusLACP DisplayString, sm24tat4xbLACPStatusKey DisplayString, sm24tat4xbLACPStatusAggrID DisplayString, sm24tat4xbLACPStatusPartnerSystemID DisplayString, sm24tat4xbLACPStatusPartnerPort DisplayString, sm24tat4xbLACPStatusPartnerPrio DisplayString } sm24tat4xbLACPStatusPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "index" ::= { sm24tat4xbLACPStatusEntry 1 } sm24tat4xbLACPStatusLACP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Yes: means that LACP is enabled and the port link is up. No: means that LACP is not enabled or that the port link is down. Backup: means that the port could not join the aggregation group but will join if other port leaves. Meanwhile it's LACP status is disabled." ::= { sm24tat4xbLACPStatusEntry 2 } sm24tat4xbLACPStatusKey OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The key assigned to this port. Only ports with the same key can aggregate together." ::= { sm24tat4xbLACPStatusEntry 3 } sm24tat4xbLACPStatusAggrID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The Aggregation ID assigned to this aggregation group." ::= { sm24tat4xbLACPStatusEntry 4 } sm24tat4xbLACPStatusPartnerSystemID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The partner's System ID (MAC address)." ::= { sm24tat4xbLACPStatusEntry 5 } sm24tat4xbLACPStatusPartnerPort OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The partner's port number connected to this port." ::= { sm24tat4xbLACPStatusEntry 6 } sm24tat4xbLACPStatusPartnerPrio OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The partner's port priority." ::= { sm24tat4xbLACPStatusEntry 7 } sm24tat4xbAggrGroupStateTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBAggrGroupStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbAggregation 7 } sm24tat4xbAggrGroupStateEntry OBJECT-TYPE SYNTAX SM24TAT4XBAggrGroupStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbAggrGroupStateIndex } ::= { sm24tat4xbAggrGroupStateTable 1 } SM24TAT4XBAggrGroupStateEntry ::= SEQUENCE { sm24tat4xbAggrGroupStateIndex Integer32, sm24tat4xbAggrGroupStateAggrID DisplayString, sm24tat4xbAggrGroupStateName DisplayString, sm24tat4xbAggrGroupStateType DisplayString, sm24tat4xbAggrGroupStateSpeed DisplayString, sm24tat4xbAggrGroupStateConfiguredPorts DisplayString, sm24tat4xbAggrGroupStateAggregatedPorts DisplayString, sm24tat4xbAggrGroupStateAggregatedBandwidth DisplayString } sm24tat4xbAggrGroupStateIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "index" ::= { sm24tat4xbAggrGroupStateEntry 1 } sm24tat4xbAggrGroupStateAggrID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "AggrID" ::= { sm24tat4xbAggrGroupStateEntry 2 } sm24tat4xbAggrGroupStateName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name" ::= { sm24tat4xbAggrGroupStateEntry 3 } sm24tat4xbAggrGroupStateType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Type" ::= { sm24tat4xbAggrGroupStateEntry 4 } sm24tat4xbAggrGroupStateSpeed OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Speed" ::= { sm24tat4xbAggrGroupStateEntry 5 } sm24tat4xbAggrGroupStateConfiguredPorts OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Configured Ports" ::= { sm24tat4xbAggrGroupStateEntry 6 } sm24tat4xbAggrGroupStateAggregatedPorts OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Aggregated Ports" ::= { sm24tat4xbAggrGroupStateEntry 7 } sm24tat4xbAggrGroupStateAggregatedBandwidth OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Aggregated Bandwidth" ::= { sm24tat4xbAggrGroupStateEntry 8 } -- ======================================================================================================================= sm24tat4xbSecurity OBJECT IDENTIFIER ::= { sm24tat4xbProductId 3 } sm24tat4xbIPSourceGuard OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 1 } sm24tat4xbIPSourceGuardConf OBJECT IDENTIFIER ::= { sm24tat4xbIPSourceGuard 1 } -- RowStatus Info: createAndGo, notReady not supported. -- ======================================================================================================================= -- Textual Conventions for the SM24TAT4XB IP Source Guard Mib -- ======================================================================================================================= -- -- sm24tat4xbIPSourceGuard OBJECT IDENTIFIER ::= { sm24tat4xbIPSourceGuardMIB 1 } -- sm24tat4xbIPSourceGuardConf OBJECT IDENTIFIER ::= { sm24tat4xbIPSourceGuard 1 } -- -- ======================================================================================================================= -- Start sm24tat4xbIPSourceGuard group -- ======================================================================================================================= --sm24tat4xbIPSourceGuardConf sm24tat4xbIPSourceGuardMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Enable the Global IP Source Guard or disable the Global IP Source Guard." ::= { sm24tat4xbIPSourceGuardConf 1 } sm24tat4xbIPSourceGuardDynamicToStaticCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Translate all dynamic entries to static entries." DEFVAL { noAction } ::= { sm24tat4xbIPSourceGuardConf 2 } --sm24tat4xbIPSourceGuardPortConfigTable sm24tat4xbIPSourceGuardPortConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPSourceGuardPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Source Guard Port Configuration Table. INDEX for this table is ifIndex which is equivalent to the panel port number." ::= { sm24tat4xbIPSourceGuardConf 3 } sm24tat4xbIPSourceGuardPortConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPSourceGuardPortConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Source Guard Port Configuration Entry." INDEX { ifIndex } ::= { sm24tat4xbIPSourceGuardPortConfigTable 1 } SM24TAT4XBIPSourceGuardPortConfigEntry ::= SEQUENCE { sm24tat4xbIPSourceGuardPortConfigMode AdminMode, sm24tat4xbIPSourceGuardPortMaxDynamicClients Integer32 } sm24tat4xbIPSourceGuardPortConfigMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Specify IP Source Guard is enabled on which ports." ::= { sm24tat4xbIPSourceGuardPortConfigEntry 2 } sm24tat4xbIPSourceGuardPortMaxDynamicClients OBJECT-TYPE SYNTAX Integer32(0..2|99) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum number of dynamic clients that can be learned on given port. default: 99 0~2: Max Dynamic clients 99:Unlimited " ::= { sm24tat4xbIPSourceGuardPortConfigEntry 3 } --sm24tat4xbIPSourceGuardStaticTable sm24tat4xbIPSourceGuardStaticTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPSourceGuardStaticEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Source Guard Static Table." ::= { sm24tat4xbIPSourceGuard 2 } sm24tat4xbIPSourceGuardStaticEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPSourceGuardStaticEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Source Guard Static Entry." INDEX { sm24tat4xbIPSourceGuardStaticIndex } ::= { sm24tat4xbIPSourceGuardStaticTable 1 } SM24TAT4XBIPSourceGuardStaticEntry ::= SEQUENCE { sm24tat4xbIPSourceGuardStaticSwitchIndex Integer32, sm24tat4xbIPSourceGuardStaticIndex Integer32, sm24tat4xbIPSourceGuardStaticPort Integer32, sm24tat4xbIPSourceGuardStaticVLANId Integer32, sm24tat4xbIPSourceGuardStaticIPAddress IpAddress, -- sm24tat4xbIPSourceGuardStaticIPMask IpAddress, sm24tat4xbIPSourceGuardStaticMACAddress DisplayString, sm24tat4xbIPSourceGuardStaticRowStatus RowStatus } sm24tat4xbIPSourceGuardStaticSwitchIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch Index." ::= { sm24tat4xbIPSourceGuardStaticEntry 1 } sm24tat4xbIPSourceGuardStaticIndex OBJECT-TYPE SYNTAX Integer32(1..28) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of table." ::= { sm24tat4xbIPSourceGuardStaticEntry 2 } sm24tat4xbIPSourceGuardStaticPort OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "The port number of table. range: 1 - port number." ::= { sm24tat4xbIPSourceGuardStaticEntry 3 } sm24tat4xbIPSourceGuardStaticVLANId OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "VLAN ID, range: 1 - 4095." ::= { sm24tat4xbIPSourceGuardStaticEntry 4 } sm24tat4xbIPSourceGuardStaticIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "IP address allowed for doing IP source guard." ::= { sm24tat4xbIPSourceGuardStaticEntry 5 } -- sm24tat4xbIPSourceGuardStaticIPMask OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-create -- STATUS current -- DESCRIPTION -- "IP Mask allowed for doing IP source guard." -- ::= { sm24tat4xbIPSourceGuardStaticEntry 6 } sm24tat4xbIPSourceGuardStaticMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Allowed Source MAC address, format: 0a 1b 2c 3d 4e 5f." ::= { sm24tat4xbIPSourceGuardStaticEntry 7 } sm24tat4xbIPSourceGuardStaticRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbIPSourceGuardStaticEntry 8 } --sm24tat4xbIPSourceGuardDynamicTable sm24tat4xbIPSourceGuardDynamicTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBIPSourceGuardDynamicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Source Guard Dynamic Table." ::= { sm24tat4xbIPSourceGuard 3 } sm24tat4xbIPSourceGuardDynamicEntry OBJECT-TYPE SYNTAX SM24TAT4XBIPSourceGuardDynamicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The IP Source Guard Dynamic Entry." INDEX { sm24tat4xbIPSourceGuardDynamicIndex } ::= { sm24tat4xbIPSourceGuardDynamicTable 1 } SM24TAT4XBIPSourceGuardDynamicEntry ::= SEQUENCE { sm24tat4xbIPSourceGuardDynamicSwitchIndex Integer32, sm24tat4xbIPSourceGuardDynamicIndex Integer32, sm24tat4xbIPSourceGuardDynamicPort Integer32, sm24tat4xbIPSourceGuardDynamicVLANId Integer32, sm24tat4xbIPSourceGuardDynamicIPAddress IpAddress, sm24tat4xbIPSourceGuardDynamicMACAddress DisplayString } sm24tat4xbIPSourceGuardDynamicSwitchIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch Index." ::= { sm24tat4xbIPSourceGuardDynamicEntry 1 } sm24tat4xbIPSourceGuardDynamicIndex OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of table." ::= { sm24tat4xbIPSourceGuardDynamicEntry 2 } sm24tat4xbIPSourceGuardDynamicPort OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The logical port for the settings." ::= { sm24tat4xbIPSourceGuardDynamicEntry 3 } sm24tat4xbIPSourceGuardDynamicVLANId OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The vlan id for the settings." ::= { sm24tat4xbIPSourceGuardDynamicEntry 4 } sm24tat4xbIPSourceGuardDynamicIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Allowed Source IP address." ::= { sm24tat4xbIPSourceGuardDynamicEntry 5 } sm24tat4xbIPSourceGuardDynamicMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Allowed Source MAC address." ::= { sm24tat4xbIPSourceGuardDynamicEntry 6 } -- ======================================================================================================================= sm24tat4xbARPInspection OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 2 } -- RowStatus Info: createAndGo, notReady not supported. -- ======================================================================================================================= -- Textual Conventions for the sm24tat4xb Arp Mib -- ======================================================================================================================= -- sm24tat4xbARP OBJECT IDENTIFIER ::= { sm24tat4xbARPInspection 1 } sm24tat4xbARPConfig OBJECT IDENTIFIER ::= { sm24tat4xbARP 1 } -- -- ======================================================================================================================= -- Start sm24tat4xbARP group -- ======================================================================================================================= --sm24tat4xbARPConfig sm24tat4xbARPConfMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Enable the Global ARP Inspection or disable the Global ARP Inspection." ::= { sm24tat4xbARPConfig 1 } --sm24tat4xbARPPortConfTable sm24tat4xbARPPortConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBARPPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Port Configuration Table." ::= { sm24tat4xbARPConfig 3 } sm24tat4xbARPPortConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBARPPortConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Port Configuration Entry." INDEX { sm24tat4xbARPPortConfPort } ::= { sm24tat4xbARPPortConfTable 1 } SM24TAT4XBARPPortConfEntry ::= SEQUENCE { sm24tat4xbARPPortConfPort Integer32, sm24tat4xbARPPortConfMode AdminMode, sm24tat4xbARPPortConfCheckVLAN AdminMode, sm24tat4xbARPPortConfLogType INTEGER } sm24tat4xbARPPortConfPort OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The port number for which the configuration below applies. range: 1 - port number." ::= { sm24tat4xbARPPortConfEntry 1 } sm24tat4xbARPPortConfMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Specify ARP Inspection is enabled on which ports." ::= { sm24tat4xbARPPortConfEntry 2 } sm24tat4xbARPPortConfCheckVLAN OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "When the setting of 'Check VLAN' is disabled, the log type of ARP Inspection will refer to the port setting. And the setting of 'Check VLAN' is enabled, the log type of ARP Inspection will refer to the VLAN setting." ::= { sm24tat4xbARPPortConfEntry 3 } sm24tat4xbARPPortConfLogType OBJECT-TYPE SYNTAX INTEGER{none(0),deny(1),permit(2),all(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "The log type of ARP Inspection will refer to the port setting. 0: none, 1: deny, 2: permit, 3: all, range: 0-3." ::= { sm24tat4xbARPPortConfEntry 4 } --sm24tat4xbARPVlanConfig sm24tat4xbARPVlanConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBARPVlanConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Vlan Configuration Table." ::= { sm24tat4xbARP 2 } sm24tat4xbARPVlanConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBARPVlanConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Vlan Configuration Entry." INDEX { sm24tat4xbARPVlanConfigVlan } ::= { sm24tat4xbARPVlanConfigTable 1 } SM24TAT4XBARPVlanConfigEntry ::= SEQUENCE { sm24tat4xbARPPortConfigIndex Integer32, sm24tat4xbARPVlanConfigVlan Integer32, sm24tat4xbARPVlanConfigLogType INTEGER, sm24tat4xbARPVlanConfigRowStatus RowStatus } sm24tat4xbARPPortConfigIndex OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Index of Vlan config Table" ::= { sm24tat4xbARPVlanConfigEntry 1 } sm24tat4xbARPVlanConfigVlan OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "Specify ARP Inspection is enabled on which VLANs. range: 1 - 4095." ::= { sm24tat4xbARPVlanConfigEntry 2 } sm24tat4xbARPVlanConfigLogType OBJECT-TYPE SYNTAX INTEGER{none(0),deny(1),permit(2),all(3)} MAX-ACCESS read-create STATUS current DESCRIPTION "The log type also can be configured on per VLAN setting. 0: none, 1: deny, 2: permit, 3: all, range: 0-3." ::= { sm24tat4xbARPVlanConfigEntry 3 } sm24tat4xbARPVlanConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbARPVlanConfigEntry 4 } --sm24tat4xbARPStaticTable sm24tat4xbARPStaticTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBARPStaticEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Static Table." ::= { sm24tat4xbARP 3 } sm24tat4xbARPStaticEntry OBJECT-TYPE SYNTAX SM24TAT4XBARPStaticEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Static Entry." INDEX { sm24tat4xbARPStaticIndex } ::= { sm24tat4xbARPStaticTable 1 } SM24TAT4XBARPStaticEntry ::= SEQUENCE { sm24tat4xbARPStaticSwitchIndex Integer32, sm24tat4xbARPStaticIndex Integer32, sm24tat4xbARPStaticPort Integer32, sm24tat4xbARPStaticVlanID Integer32, sm24tat4xbARPStaticMACAddress DisplayString, sm24tat4xbARPStaticIPAddress IpAddress, sm24tat4xbARPStaticRowStatus RowStatus } sm24tat4xbARPStaticSwitchIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch Index." ::= { sm24tat4xbARPStaticEntry 1 } sm24tat4xbARPStaticIndex OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of table." ::= { sm24tat4xbARPStaticEntry 2 } sm24tat4xbARPStaticPort OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "The logical port for the settings. range: 1 - port number." ::= { sm24tat4xbARPStaticEntry 3 } sm24tat4xbARPStaticVlanID OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "The vlan id for the settings. range: 1-4095." ::= { sm24tat4xbARPStaticEntry 4 } sm24tat4xbARPStaticMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Allowed Source MAC address in ARP request packets." ::= { sm24tat4xbARPStaticEntry 5 } sm24tat4xbARPStaticIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Allowed Source IP address in ARP request packets." ::= { sm24tat4xbARPStaticEntry 6 } sm24tat4xbARPStaticRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbARPStaticEntry 7 } --sm24tat4xbARPDynamicTable sm24tat4xbARPDynamicTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBARPDynamicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Dynamic Table." ::= { sm24tat4xbARP 4 } sm24tat4xbARPDynamicEntry OBJECT-TYPE SYNTAX SM24TAT4XBARPDynamicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ARP Dynamic Entry." INDEX { sm24tat4xbARPDynamicIndex } ::= { sm24tat4xbARPDynamicTable 1 } SM24TAT4XBARPDynamicEntry ::= SEQUENCE { sm24tat4xbARPDynamicIndex Integer32, sm24tat4xbARPDynamicPort Integer32, sm24tat4xbARPDynamicVLANId Integer32, sm24tat4xbARPDynamicMACAddress MacAddress, sm24tat4xbARPDynamicIPAddress IpAddress, sm24tat4xbARPDynamicToStaticCmd INTEGER } sm24tat4xbARPDynamicIndex OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry of table." ::= { sm24tat4xbARPDynamicEntry 1 } sm24tat4xbARPDynamicPort OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Switch Port Number for which the entries are displayed." ::= { sm24tat4xbARPDynamicEntry 2 } sm24tat4xbARPDynamicVLANId OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN-ID in which the ARP traffic is permitted." ::= { sm24tat4xbARPDynamicEntry 3 } sm24tat4xbARPDynamicMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "User MAC address of the entry." ::= { sm24tat4xbARPDynamicEntry 4 } sm24tat4xbARPDynamicIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "User IP address of the entry." ::= { sm24tat4xbARPDynamicEntry 5 } sm24tat4xbARPDynamicToStaticCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Enable the Global ARP Inspection or disable the Global ARP Inspection." ::= { sm24tat4xbARPDynamicEntry 6 } -- ======================================================================================================================= -- sm24tat4xbARPConformance -- ======================================================================================================================= sm24tat4xbARPConformance OBJECT IDENTIFIER ::= { sm24tat4xbARPInspection 200 } sm24tat4xbARPCompliances OBJECT IDENTIFIER ::= { sm24tat4xbARPConformance 1 } sm24tat4xbARPGroups OBJECT IDENTIFIER ::= { sm24tat4xbARPConformance 2 } sm24tat4xbARPGroup OBJECT-GROUP OBJECTS { -- sm24tat4xbARPConfig sm24tat4xbARPConfMode, --sm24tat4xbARPPortConfTable sm24tat4xbARPPortConfMode, sm24tat4xbARPPortConfCheckVLAN, sm24tat4xbARPPortConfLogType, --sm24tat4xbARPVlanConfig sm24tat4xbARPVlanConfigLogType, sm24tat4xbARPVlanConfigRowStatus, --sm24tat4xbARPStaticTable sm24tat4xbARPStaticPort, sm24tat4xbARPStaticVlanID, sm24tat4xbARPStaticMACAddress, sm24tat4xbARPStaticIPAddress, sm24tat4xbARPStaticRowStatus, --sm24tat4xbARPDynamicTable sm24tat4xbARPDynamicPort, sm24tat4xbARPDynamicVLANId, sm24tat4xbARPDynamicMACAddress, sm24tat4xbARPDynamicIPAddress, sm24tat4xbARPDynamicToStaticCmd } STATUS current DESCRIPTION "The collection of objects which are used to indicate sm24tat4xb ARP information." ::= { sm24tat4xbARPGroups 1 } -- ======================================================================================================================= sm24tat4xbDHCPSnooping OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 3 } sm24tat4xbDHCPSnoopingConf OBJECT IDENTIFIER ::= { sm24tat4xbDHCPSnooping 1 } sm24tat4xbDHCPSnoopingMode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: enable" ::= { sm24tat4xbDHCPSnoopingConf 1 } sm24tat4xbDHCPSnoopingPortModeConfigurationTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBDHCPSnoopingPortModeConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingConf 2 } sm24tat4xbDHCPSnoopingPortModeConfigurationEntry OBJECT-TYPE SYNTAX SM24TAT4XBDHCPSnoopingPortModeConfigurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbDHCPSnoopingPortModeConfigurationPort } ::= { sm24tat4xbDHCPSnoopingPortModeConfigurationTable 1 } SM24TAT4XBDHCPSnoopingPortModeConfigurationEntry ::= SEQUENCE { sm24tat4xbDHCPSnoopingPortModeConfigurationPort Integer32, sm24tat4xbDHCPSnoopingPortModeConfigurationMode Integer32 } sm24tat4xbDHCPSnoopingPortModeConfigurationPort OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingPortModeConfigurationEntry 1 } sm24tat4xbDHCPSnoopingPortModeConfigurationMode OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 1 0: trust port mode 1: untrust port mode" ::= { sm24tat4xbDHCPSnoopingPortModeConfigurationEntry 2 } sm24tat4xbDHCPSnoopingStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBDHCPSnoopingStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnooping 2 } sm24tat4xbDHCPSnoopingStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBDHCPSnoopingStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbDHCPSnoopingStatisticsPort } ::= { sm24tat4xbDHCPSnoopingStatisticsTable 1 } SM24TAT4XBDHCPSnoopingStatisticsEntry ::= SEQUENCE { sm24tat4xbDHCPSnoopingStatisticsPort Integer32, sm24tat4xbDHCPSnoopingStatisticsClear Integer32, sm24tat4xbDHCPSnoopingRxDiscover Counter32, sm24tat4xbDHCPSnoopingRxOffer Counter32, sm24tat4xbDHCPSnoopingRxRequest Counter32, sm24tat4xbDHCPSnoopingRxDecline Counter32, sm24tat4xbDHCPSnoopingRxACK Counter32, sm24tat4xbDHCPSnoopingRxNAK Counter32, sm24tat4xbDHCPSnoopingRxRelease Counter32, sm24tat4xbDHCPSnoopingRxInform Counter32, sm24tat4xbDHCPSnoopingRxLeaseQuery Counter32, sm24tat4xbDHCPSnoopingRxLeaseUnassigned Counter32, sm24tat4xbDHCPSnoopingRxLeaseUnknown Counter32, sm24tat4xbDHCPSnoopingRxLeaseActive Counter32, sm24tat4xbDHCPSnoopingTxDiscover Counter32, sm24tat4xbDHCPSnoopingTxOffer Counter32, sm24tat4xbDHCPSnoopingTxRequest Counter32, sm24tat4xbDHCPSnoopingTxDecline Counter32, sm24tat4xbDHCPSnoopingTxACK Counter32, sm24tat4xbDHCPSnoopingTxNAK Counter32, sm24tat4xbDHCPSnoopingTxRelease Counter32, sm24tat4xbDHCPSnoopingTxInform Counter32, sm24tat4xbDHCPSnoopingTxLeaseQuery Counter32, sm24tat4xbDHCPSnoopingTxLeaseUnassigned Counter32, sm24tat4xbDHCPSnoopingTxLeaseUnknown Counter32, sm24tat4xbDHCPSnoopingTxLeaseActive Counter32, sm24tat4xbDHCPSnoopingRxDiscardedChecksumError Counter32, sm24tat4xbDHCPSnoopingRxDiscardedFromUntrusted Counter32 } sm24tat4xbDHCPSnoopingStatisticsPort OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 1 } sm24tat4xbDHCPSnoopingStatisticsClear OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: none 1: clear" ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 2 } sm24tat4xbDHCPSnoopingRxDiscover OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 3 } sm24tat4xbDHCPSnoopingRxOffer OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 4 } sm24tat4xbDHCPSnoopingRxRequest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 5 } sm24tat4xbDHCPSnoopingRxDecline OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 6 } sm24tat4xbDHCPSnoopingRxACK OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 7 } sm24tat4xbDHCPSnoopingRxNAK OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 8 } sm24tat4xbDHCPSnoopingRxRelease OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 9 } sm24tat4xbDHCPSnoopingRxInform OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 10 } sm24tat4xbDHCPSnoopingRxLeaseQuery OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 11 } sm24tat4xbDHCPSnoopingRxLeaseUnassigned OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 12 } sm24tat4xbDHCPSnoopingRxLeaseUnknown OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 13 } sm24tat4xbDHCPSnoopingRxLeaseActive OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 14 } sm24tat4xbDHCPSnoopingTxDiscover OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 15 } sm24tat4xbDHCPSnoopingTxOffer OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 16 } sm24tat4xbDHCPSnoopingTxRequest OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 17 } sm24tat4xbDHCPSnoopingTxDecline OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 18 } sm24tat4xbDHCPSnoopingTxACK OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 19 } sm24tat4xbDHCPSnoopingTxNAK OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 20 } sm24tat4xbDHCPSnoopingTxRelease OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 21 } sm24tat4xbDHCPSnoopingTxInform OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 22 } sm24tat4xbDHCPSnoopingTxLeaseQuery OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 23 } sm24tat4xbDHCPSnoopingTxLeaseUnassigned OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 24 } sm24tat4xbDHCPSnoopingTxLeaseUnknown OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 25 } sm24tat4xbDHCPSnoopingTxLeaseActive OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 26 } sm24tat4xbDHCPSnoopingRxDiscardedChecksumError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 27 } sm24tat4xbDHCPSnoopingRxDiscardedFromUntrusted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPSnoopingStatisticsEntry 28 } sm24tat4xbDHCPRelay OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 4 } sm24tat4xbDHCPRelayConfiguration OBJECT IDENTIFIER ::= { sm24tat4xbDHCPRelay 1 } sm24tat4xbDHCPRelayMode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: enable We need at least one server" ::= { sm24tat4xbDHCPRelayConfiguration 1 } sm24tat4xbDHCPRelayServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayConfiguration 2 } sm24tat4xbDHCPRelayInformationMode OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: enable " ::= { sm24tat4xbDHCPRelayConfiguration 3 } sm24tat4xbDHCPRelayInformationPolicy OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: replace 1: keep 2: drop " ::= { sm24tat4xbDHCPRelayConfiguration 4 } sm24tat4xbDHCPRelayStatistics OBJECT IDENTIFIER ::= { sm24tat4xbDHCPRelay 2 } sm24tat4xbDHCPRelayServerStatistics OBJECT IDENTIFIER ::= { sm24tat4xbDHCPRelayStatistics 1 } sm24tat4xbServerStatTransmitToServer OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 1 } sm24tat4xbServerStatTransmitError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 2 } sm24tat4xbServerStatReceiveFromServer OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 3 } sm24tat4xbServerStatReceiveMissingAgentOption OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 4 } sm24tat4xbServerStatReceiveMissingCircuitID OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 5 } sm24tat4xbServerStatReceiveMissingRemoteID OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 6 } sm24tat4xbServerStatReceiveBadCircuitID OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 7 } sm24tat4xbServerStatReceiveBadRemoteID OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayServerStatistics 8 } sm24tat4xbDHCPRelayClientStatistics OBJECT IDENTIFIER ::= { sm24tat4xbDHCPRelayStatistics 2 } sm24tat4xbClientStatTransmitToClient OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 1 } sm24tat4xbClientStatTransmitError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 2 } sm24tat4xbClientStatReceivefromClient OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 3 } sm24tat4xbClientStatReceiveAgentOption OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 4 } sm24tat4xbClientStatReplaceAgentOption OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 5 } sm24tat4xbClientStatKeepAgentOption OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 6 } sm24tat4xbClientStatDropAgentOption OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbDHCPRelayClientStatistics 7 } sm24tat4xbPortSecurity OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 5 } sm24tat4xbPortSecLimitCtrl OBJECT IDENTIFIER ::= { sm24tat4xbPortSecurity 1 } sm24tat4xbPortSecLimitCtrlSystemConf OBJECT IDENTIFIER ::= { sm24tat4xbPortSecLimitCtrl 1 } -- sm24tat4xbPortSecurityMode OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0 -- 0: disable -- 1: enable " -- ::= { sm24tat4xbPortSecLimitCtrlSystemConf 1 } sm24tat4xbPortSecurityAging OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: enable " ::= { sm24tat4xbPortSecLimitCtrlSystemConf 1 } sm24tat4xbPortSecurityAgingPeriod OBJECT-TYPE SYNTAX Integer32(10..10000000) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 3600, range: 10-10000000 " ::= { sm24tat4xbPortSecLimitCtrlSystemConf 2 } sm24tat4xbPortSecurityHoldTime OBJECT-TYPE SYNTAX Integer32(10..10000000) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 300, range: 10-10000000 " ::= { sm24tat4xbPortSecLimitCtrlSystemConf 3 } sm24tat4xbPortSecLimitCtrlTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPortSecLimitCtrlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecLimitCtrl 2 } sm24tat4xbPortSecLimitCtrlEntry OBJECT-TYPE SYNTAX SM24TAT4XBPortSecLimitCtrlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPortSecLimitCtrlPort } ::= { sm24tat4xbPortSecLimitCtrlTable 1 } SM24TAT4XBPortSecLimitCtrlEntry ::= SEQUENCE { sm24tat4xbPortSecLimitCtrlPort Integer32, sm24tat4xbPortSecLimitCtrlPortMode Integer32, sm24tat4xbPortSecLimitCtrlPortLimit Integer32, sm24tat4xbPortSecLimitCtrlPortViolationmMode Integer32, sm24tat4xbPortSecLimitCtrlPortViolationmLimit Integer32, sm24tat4xbPortSecLimitCtrlPortState DisplayString, sm24tat4xbPortSecLimitCtrlPortReOpen Integer32, sm24tat4xbPortSecLimitCtrlPortSticky Integer32, sm24tat4xbPortSecLimitCtrlPortClear Integer32 } sm24tat4xbPortSecLimitCtrlPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecLimitCtrlEntry 1 } sm24tat4xbPortSecLimitCtrlPortMode OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: enable" ::= { sm24tat4xbPortSecLimitCtrlEntry 2 } sm24tat4xbPortSecLimitCtrlPortLimit OBJECT-TYPE SYNTAX Integer32(1..1024) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 4, range: 1-1024" ::= { sm24tat4xbPortSecLimitCtrlEntry 3 } sm24tat4xbPortSecLimitCtrlPortViolationmMode OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: Protect 1: Restrict 2: Shutdown" ::= { sm24tat4xbPortSecLimitCtrlEntry 4 } sm24tat4xbPortSecLimitCtrlPortViolationmLimit OBJECT-TYPE SYNTAX Integer32(1..1024) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 4, range: 1-1024" ::= { sm24tat4xbPortSecLimitCtrlEntry 5 } sm24tat4xbPortSecLimitCtrlPortState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecLimitCtrlEntry 6 } sm24tat4xbPortSecLimitCtrlPortReOpen OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: none 1: reopen" ::= { sm24tat4xbPortSecLimitCtrlEntry 7 } sm24tat4xbPortSecLimitCtrlPortSticky OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: disable 1: enable" ::= { sm24tat4xbPortSecLimitCtrlEntry 8 } sm24tat4xbPortSecLimitCtrlPortClear OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 1: clear" ::= { sm24tat4xbPortSecLimitCtrlEntry 9 } sm24tat4xbPortSecSwitchStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPortSecSwitchStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecurity 2 } sm24tat4xbPortSecSwitchStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBPortSecSwitchStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPortSecSwitchStatusPort } ::= { sm24tat4xbPortSecSwitchStatusTable 1 } SM24TAT4XBPortSecSwitchStatusEntry ::= SEQUENCE { sm24tat4xbPortSecSwitchStatusPort Integer32, -- sm24tat4xbPortSecSwitchStatusUsers DisplayString, sm24tat4xbPortSecSwitchStatusViolationmMode DisplayString, sm24tat4xbPortSecSwitchStatusState DisplayString, sm24tat4xbPortSecSwitchStatusMACCountCurrent Integer32, sm24tat4xbPortSecSwitchStatusMACCountViolating Integer32, sm24tat4xbPortSecSwitchStatusMACCountLimit Integer32, sm24tat4xbPortSecSwitchStatusClear Integer32 } sm24tat4xbPortSecSwitchStatusPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecSwitchStatusEntry 1 } -- sm24tat4xbPortSecSwitchStatusUsers OBJECT-TYPE -- SYNTAX DisplayString -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " Users Abbr: L = Limit Control, 8 = 802.1X, D = DHCP Snooping, V = Voice VLAN, -- '-' means that the corresponding user module is not enabled. " -- ::= { sm24tat4xbPortSecSwitchStatusEntry 2 } sm24tat4xbPortSecSwitchStatusViolationmMode OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Shows the configured Violation Mode of the port." ::= { sm24tat4xbPortSecSwitchStatusEntry 3 } sm24tat4xbPortSecSwitchStatusState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Shows the current state of the port : Disabled, Ready, Limit Reached, Shutdown. " ::= { sm24tat4xbPortSecSwitchStatusEntry 4 } sm24tat4xbPortSecSwitchStatusMACCountCurrent OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecSwitchStatusEntry 5 } sm24tat4xbPortSecSwitchStatusMACCountViolating OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecSwitchStatusEntry 6 } sm24tat4xbPortSecSwitchStatusMACCountLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecSwitchStatusEntry 7 } sm24tat4xbPortSecSwitchStatusClear OBJECT-TYPE SYNTAX Integer32 (0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Remove all MAC addresses on all VLANs on this port." ::= { sm24tat4xbPortSecSwitchStatusEntry 8 } sm24tat4xbPortSecPortStatus OBJECT IDENTIFIER ::= { sm24tat4xbPortSecurity 3 } sm24tat4xbPortSecPortStatusPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "port number default: 1 range: 1 - port number." ::= { sm24tat4xbPortSecPortStatus 1 } sm24tat4xbPortSecPortStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBPortSecPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecPortStatus 2 } sm24tat4xbPortSecPortStatusEntry OBJECT-TYPE SYNTAX SM24TAT4XBPortSecPortStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbPortSecPortStatusIndex } ::= { sm24tat4xbPortSecPortStatusTable 1 } SM24TAT4XBPortSecPortStatusEntry ::= SEQUENCE { sm24tat4xbPortSecPortStatusIndex Integer32, sm24tat4xbPortSecPortStatusMACAddress DisplayString, sm24tat4xbPortSecPortStatusVLANId Integer32, sm24tat4xbPortSecPortStatusState DisplayString, sm24tat4xbPortSecPortStatusAgeAndHold DisplayString, sm24tat4xbPortSecPortStatusClear Integer32 } sm24tat4xbPortSecPortStatusIndex OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecPortStatusEntry 1 } sm24tat4xbPortSecPortStatusMACAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address that is seen on this port." ::= { sm24tat4xbPortSecPortStatusEntry 2 } sm24tat4xbPortSecPortStatusVLANId OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "VLAN ID that is seen on this port" ::= { sm24tat4xbPortSecPortStatusEntry 3 } sm24tat4xbPortSecPortStatusState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the corresponding MAC address is violating (administrative user has configured the interface in Restrict mode and the MAC address is blocked), blocked, or forwarding." ::= { sm24tat4xbPortSecPortStatusEntry 4 } sm24tat4xbPortSecPortStatusAgeAndHold OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " " ::= { sm24tat4xbPortSecPortStatusEntry 5 } sm24tat4xbPortSecPortStatusClear OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "Remove particular MAC addresses from MAC table 1:clear" ::= { sm24tat4xbPortSecPortStatusEntry 6 } sm24tat4xbAccessManagement OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 6 } sm24tat4xbAccessMgmtConf OBJECT IDENTIFIER ::= { sm24tat4xbAccessManagement 1 } sm24tat4xbAccessMgmtStatistics OBJECT IDENTIFIER ::= { sm24tat4xbAccessManagement 2 } -- -- ======================================================================================================================= -- Start sm24tat4xbAccessManagement group -- ======================================================================================================================= --sm24tat4xbAccessMgmtConf sm24tat4xbAccessMgmtConfMode OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the access management mode operation." DEFVAL { disable } ::= { sm24tat4xbAccessMgmtConf 1 } --sm24tat4xbAccessMgmtConfTable sm24tat4xbAccessMgmtConfTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBAccessMgmtConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Access Mgmt Conf Table. " ::= { sm24tat4xbAccessMgmtConf 2 } sm24tat4xbAccessMgmtConfEntry OBJECT-TYPE SYNTAX SM24TAT4XBAccessMgmtConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Access Mgmt Conf Entry " INDEX { sm24tat4xbAccessMgmtIndex } ::= { sm24tat4xbAccessMgmtConfTable 1 } SM24TAT4XBAccessMgmtConfEntry ::= SEQUENCE { sm24tat4xbAccessMgmtIndex Integer32, sm24tat4xbAccessMgmtVlanID Integer32, sm24tat4xbAccessMgmtStartIpAddress IpAddress, sm24tat4xbAccessMgmtEndIpAddress IpAddress, sm24tat4xbAccessMgmtHttpHttps AdminMode, sm24tat4xbAccessMgmtSNMP AdminMode, sm24tat4xbAccessMgmtTelnetSSH AdminMode, sm24tat4xbAccessMgmtRowStatus RowStatus } sm24tat4xbAccessMgmtIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Access Management config index. range : 1-16." ::= { sm24tat4xbAccessMgmtConfEntry 1 } sm24tat4xbAccessMgmtVlanID OBJECT-TYPE SYNTAX Integer32 (1..4095) MAX-ACCESS read-create STATUS current DESCRIPTION "The VLAN ID for the access management entry. range: 1-4095." ::= { sm24tat4xbAccessMgmtConfEntry 2 } sm24tat4xbAccessMgmtStartIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The start IP address for the access management entry." ::= { sm24tat4xbAccessMgmtConfEntry 3 } sm24tat4xbAccessMgmtEndIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The end IP address for the access management entry. " ::= { sm24tat4xbAccessMgmtConfEntry 4 } sm24tat4xbAccessMgmtHttpHttps OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates that the host can access the switch from HTTP/HTTPS interface if the host IP address matches the IP address range provided in the entry." DEFVAL { disable } ::= { sm24tat4xbAccessMgmtConfEntry 5 } sm24tat4xbAccessMgmtSNMP OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates that the host can access the switch from SNMP interface if the host IP address matches the IP address range provided in the entry." DEFVAL { disable } ::= { sm24tat4xbAccessMgmtConfEntry 6 } sm24tat4xbAccessMgmtTelnetSSH OBJECT-TYPE SYNTAX AdminMode MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates that the host can access the switch from TELNET/SSH interface if the host IP address matches the IP address range provided in the entry." DEFVAL { disable } ::= { sm24tat4xbAccessMgmtConfEntry 7 } sm24tat4xbAccessMgmtRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object indicates the status of this entry, and is used to create/delete entries. Any object in an entry of this table may be modified while the value of the corresponding instance of this object is active(1). createAndGo, notReady not supported." ::= { sm24tat4xbAccessMgmtConfEntry 8 } --sm24tat4xbAccessMgmtStatistics sm24tat4xbAccessMgmtStatisticsClear OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Clear all statistics." ::= { sm24tat4xbAccessMgmtStatistics 1 } --sm24tat4xbAccessMgmtStatisticsTable sm24tat4xbAccessMgmtStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBAccessMgmtStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Access Mgmt Statistics Table. " ::= { sm24tat4xbAccessMgmtStatistics 2 } sm24tat4xbAccessMgmtStatisticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBAccessMgmtStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Access Mgmt Statistics Entry. " INDEX { sm24tat4xbAccessMgmtStatisticsInterface } ::= { sm24tat4xbAccessMgmtStatisticsTable 1 } SM24TAT4XBAccessMgmtStatisticsEntry ::= SEQUENCE { sm24tat4xbAccessMgmtStatisticsInterface INTEGER, sm24tat4xbAccessMgmtStatisticsReceivedPackets Integer32, sm24tat4xbAccessMgmtStatisticsAllowedPackets Integer32, sm24tat4xbAccessMgmtStatisticsDiscardedPackets Integer32 } sm24tat4xbAccessMgmtStatisticsInterface OBJECT-TYPE SYNTAX INTEGER { http(1), https(2), snmp(3), telnet(4), ssh (5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The interface type through which the remote host can access the switch. 1: HTTP, 2: HTTPs, 3: SNMP, 4: TELNET, 5: SSH" ::= { sm24tat4xbAccessMgmtStatisticsEntry 1 } sm24tat4xbAccessMgmtStatisticsReceivedPackets OBJECT-TYPE SYNTAX Integer32(1..10000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of received packets from the interface when access management mode is enabled. " ::= { sm24tat4xbAccessMgmtStatisticsEntry 2 } sm24tat4xbAccessMgmtStatisticsAllowedPackets OBJECT-TYPE SYNTAX Integer32(1..10000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of allowed packets from the interface when access management mode is enabled. " ::= { sm24tat4xbAccessMgmtStatisticsEntry 3 } sm24tat4xbAccessMgmtStatisticsDiscardedPackets OBJECT-TYPE SYNTAX Integer32(1..10000000) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of discarded packets from the interface when access management mode is enabled. " ::= { sm24tat4xbAccessMgmtStatisticsEntry 4 } -- ======================================================================================================================= --sm24tat4xbSSH OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 7 } -- --sm24tat4xbSSHMode OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 1 -- 0: disable -- 1: enable" -- ::= { sm24tat4xbSSH 1 } --sm24tat4xbSSHPort OBJECT-TYPE -- SYNTAX Integer32(1..65535) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "SSH service port number. -- range : 1-65535, default : 22." -- ::= { sm24tat4xbSSH 2 } sm24tat4xbHTTPS OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 8 } -- --sm24tat4xbHTTPSMode OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 1 -- 0: disable -- 1: enable" -- ::= { sm24tat4xbHTTPS 1 } -- --sm24tat4xbHTTPSAutoRedirect OBJECT-TYPE -- SYNTAX Integer32(0|1) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "default: 0 -- 0: disable -- 1: enable" -- ::= { sm24tat4xbHTTPS 2 } -- --sm24tat4xbHTTPSPort OBJECT-TYPE -- SYNTAX Integer32(1..65535) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "HTTPS service port number. -- range : 1-65535, default : 443." -- ::= { sm24tat4xbHTTPS 3 } -- sm24tat4xbHTTPSCertificateMaintain OBJECT-TYPE SYNTAX Integer32(2..3) MAX-ACCESS read-write STATUS current DESCRIPTION "2: Upload 3: Generate" ::= { sm24tat4xbHTTPS 4 } sm24tat4xbHTTPSCertificatePassPhrase OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Enter the pass phrase in this field if your uploading certificate is protected by a specific passphrase." ::= { sm24tat4xbHTTPS 5 } sm24tat4xbHTTPSCertificateUpload OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "default: 0 0: TFTP 1: URL" ::= { sm24tat4xbHTTPS 6 } sm24tat4xbHTTPSFileUploadFileURL OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "TFTP: filename URL: URL" ::= { sm24tat4xbHTTPS 7 } sm24tat4xbHTTPSFileUploadTFTPServer OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "TFTP server IP address" ::= { sm24tat4xbHTTPS 8 } sm24tat4xbHTTPSApply OBJECT-TYPE SYNTAX Integer32(0|1) MAX-ACCESS read-write STATUS current DESCRIPTION "1: apply the above https settings" ::= { sm24tat4xbHTTPS 9 } sm24tat4xbHTTPSCertificateStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Display the current status of certificate on the switch." ::= { sm24tat4xbHTTPS 10 } sm24tat4xbAuthMethod OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 9 } -- -- ======================================================================================================================= -- Start sm24tat4xbAuthMethodConfig group -- ======================================================================================================================= --sm24tat4xbAuthMethodConfigTable sm24tat4xbAuthMethodConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBAuthMethodConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Auth Method Config Table." ::= { sm24tat4xbAuthMethod 1 } sm24tat4xbAuthMethodConfigEntry OBJECT-TYPE SYNTAX SM24TAT4XBAuthMethodConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Auth Method Config Entry." INDEX { sm24tat4xbAuthMethodConfigClient } ::= { sm24tat4xbAuthMethodConfigTable 1 } SM24TAT4XBAuthMethodConfigEntry ::= SEQUENCE { sm24tat4xbAuthMethodConfigClient INTEGER, sm24tat4xbAuthMethodConfigMethod1 INTEGER, sm24tat4xbAuthMethodConfigMethod2 INTEGER, sm24tat4xbAuthMethodConfigMethod3 INTEGER, sm24tat4xbAuthMethodConfigMethod4 INTEGER, sm24tat4xbAuthMethodConfigServicePort Integer32 } sm24tat4xbAuthMethodConfigClient OBJECT-TYPE SYNTAX INTEGER { console ( 1 ), telnet ( 2 ), ssh ( 3 ), http ( 4 ), https ( 5 ) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "1: console. 2: telnet. 3: ssh. 4: http. 5: https. " ::= { sm24tat4xbAuthMethodConfigEntry 1 } sm24tat4xbAuthMethodConfigMethod1 OBJECT-TYPE SYNTAX INTEGER {no(0) ,redirect(1) ,local(2) ,radius(3) ,tacacs(4)} MAX-ACCESS read-write STATUS current DESCRIPTION "Methods that involves remote servers are timed out if the remote servers are offline.Each method is tried from left to right and continues until a method either approves or rejects a user. 0: no, Authentication is disabled and login is not possible. 1: redirect, When HTTPS is enabled, enable HTTPS automatic redirect on the switch. 2: local, Use the local user database on the switch for authentication. 3: radius, Use remote RADIUS server(s) for authentication. 4: tacacs+, Use remote TACACS+ server(s) for authentication." ::= { sm24tat4xbAuthMethodConfigEntry 2 } sm24tat4xbAuthMethodConfigMethod2 OBJECT-TYPE SYNTAX INTEGER {no(0) ,redirect(1) ,local(2) ,radius(3) ,tacacs(4)} MAX-ACCESS read-write STATUS current DESCRIPTION "Methods that involves remote servers are timed out if the remote servers are offline.Each method is tried from left to right and continues until a method either approves or rejects a user. 0: no, Authentication is disabled and login is not possible. 1: redirect, When HTTPS is enabled, enable HTTPS automatic redirect on the switch. 2: local, Use the local user database on the switch for authentication. 3: radius, Use remote RADIUS server(s) for authentication. 4: tacacs+, Use remote TACACS+ server(s) for authentication." ::= { sm24tat4xbAuthMethodConfigEntry 3 } sm24tat4xbAuthMethodConfigMethod3 OBJECT-TYPE SYNTAX INTEGER {no(0) ,redirect(1) ,local(2) ,radius(3) ,tacacs(4)} MAX-ACCESS read-write STATUS current DESCRIPTION "Methods that involves remote servers are timed out if the remote servers are offline.Each method is tried from left to right and continues until a method either approves or rejects a user. 0: no, Authentication is disabled and login is not possible. 1: redirect, When HTTPS is enabled, enable HTTPS automatic redirect on the switch. 2: local, Use the local user database on the switch for authentication. 3: radius, Use remote RADIUS server(s) for authentication. 4: tacacs+, Use remote TACACS+ server(s) for authentication." ::= { sm24tat4xbAuthMethodConfigEntry 4 } sm24tat4xbAuthMethodConfigMethod4 OBJECT-TYPE SYNTAX INTEGER {no(0) ,redirect(1) ,local(2) ,radius(3) ,tacacs(4)} MAX-ACCESS read-write STATUS current DESCRIPTION "Methods that involves remote servers are timed out if the remote servers are offline.Each method is tried from left to right and continues until a method either approves or rejects a user. 0: no, Authentication is disabled and login is not possible. 1: redirect, When HTTPS is enabled, enable HTTPS automatic redirect on the switch. 2: local, Use the local user database on the switch for authentication. 3: radius, Use remote RADIUS server(s) for authentication. 4: tacacs+, Use remote TACACS+ server(s) for authentication." ::= { sm24tat4xbAuthMethodConfigEntry 5 } sm24tat4xbAuthMethodConfigServicePort OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The network port number this client bound to provide service." ::= { sm24tat4xbAuthMethodConfigEntry 6 } sm24tat4xbCommandAuthorizationMethodTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBCommandAuthorizationMethodEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Command Authorized Method Config Table." ::= { sm24tat4xbAuthMethod 2 } sm24tat4xbCommandAuthorizationMethodEntry OBJECT-TYPE SYNTAX SM24TAT4XBCommandAuthorizationMethodEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Command Authorized Method Config Entry." INDEX { sm24tat4xbCommandAuthorizationMethodClient } ::= { sm24tat4xbCommandAuthorizationMethodTable 1 } SM24TAT4XBCommandAuthorizationMethodEntry ::= SEQUENCE { sm24tat4xbCommandAuthorizationMethodClient INTEGER, sm24tat4xbCommandAuthorizationMethodMethod Integer32, sm24tat4xbCommandAuthorizationMethodCmdLvl Integer32, sm24tat4xbCommandAuthorizationMethodCfgCmd Integer32 } sm24tat4xbCommandAuthorizationMethodClient OBJECT-TYPE SYNTAX INTEGER { console ( 1 ), telnet ( 2 ), ssh ( 3 ), http ( 4 ), https ( 5 ) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "1: console. 2: telnet. 3: ssh. 4: http. 5: https. " ::= { sm24tat4xbCommandAuthorizationMethodEntry 1 } sm24tat4xbCommandAuthorizationMethodMethod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Method can be set to one of the following values: 0:no: Command authorization is disabled. User is granted access to CLI commands according to his privilege level. 4:tacacs: Use remote TACACS+ server(s) for command authorization. If all remote servers are offline, the user is granted access to CLI commands according to his privilege level." ::= { sm24tat4xbCommandAuthorizationMethodEntry 2 } sm24tat4xbCommandAuthorizationMethodCmdLvl OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Authorize all commands with a privilege level higher than or equal to this level. Valid values are in the range 0 to 15." ::= { sm24tat4xbCommandAuthorizationMethodEntry 3 } sm24tat4xbCommandAuthorizationMethodCfgCmd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Also authorize configuration commands. 0:Disable 1:Enable" ::= { sm24tat4xbCommandAuthorizationMethodEntry 4 } sm24tat4xbAccountingMethodTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBAccountingMethodEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Accounting Method Config Table." ::= { sm24tat4xbAuthMethod 3 } sm24tat4xbAccountingMethodEntry OBJECT-TYPE SYNTAX SM24TAT4XBAccountingMethodEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Accounting Method Config Entry." INDEX { sm24tat4xbAccountingMethodClient } ::= { sm24tat4xbAccountingMethodTable 1 } SM24TAT4XBAccountingMethodEntry ::= SEQUENCE { sm24tat4xbAccountingMethodClient INTEGER, sm24tat4xbAccountingMethodMethod Integer32, sm24tat4xbAccountingMethodCmdLvl Integer32, sm24tat4xbAccountingMethodCfgCmd Integer32 } sm24tat4xbAccountingMethodClient OBJECT-TYPE SYNTAX INTEGER { console ( 1 ), telnet ( 2 ), ssh ( 3 ), http ( 4 ), https ( 5 ) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "1: console. 2: telnet. 3: ssh. 4: http. 5: https. " ::= { sm24tat4xbAccountingMethodEntry 1 } sm24tat4xbAccountingMethodMethod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Method can be set to one of the following values: 0:no: Accounting is disabled. 4:tacacs: Use remote TACACS+ server(s) for accounting." ::= { sm24tat4xbAccountingMethodEntry 2 } sm24tat4xbAccountingMethodCmdLvl OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable accounting of all commands with a privilege level higher than or equal to this level. Valid values are in the range 0 to 15. Leave the field empty to disable command accounting." ::= { sm24tat4xbAccountingMethodEntry 3 } sm24tat4xbAccountingMethodCfgCmd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Enable exec (login) accounting. 0:Disable 1:Enable" ::= { sm24tat4xbAccountingMethodEntry 4 } -- sm24tat4xbTELNET OBJECT IDENTIFIER ::= { sm24tat4xbSecurity 10 } -- sm24tat4xbTELNETPort OBJECT-TYPE -- SYNTAX Integer32(1..65535) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "TELNET service port number. -- range : 1-65535, default : 23." -- ::= { sm24tat4xbTELNET 1 } -- ======================================================================================================================= sm24tat4xbMaintenance OBJECT IDENTIFIER ::= { sm24tat4xbProductId 4 } sm24tat4xbSoftware OBJECT IDENTIFIER ::= { sm24tat4xbMaintenance 3 } sm24tat4xbConfig OBJECT IDENTIFIER ::= { sm24tat4xbMaintenance 4 } -- -- ======================================================================================================================= -- Objects in the sm24tat4xbMaintenance Group -- ======================================================================================================================= sm24tat4xbRestartDevice OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Command to restart the device." DEFVAL { noAction } ::= { sm24tat4xbMaintenance 1 } sm24tat4xbFactoryDefaults OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Reset the configuration to Factory Defaults keep-ip." DEFVAL { noAction } ::= { sm24tat4xbMaintenance 2 } --sm24tat4xbSoftware sm24tat4xbSoftwareUsername OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the username for 'tftp' firmware upgrading." ::= { sm24tat4xbSoftware 1 } sm24tat4xbSoftwarePassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the password for 'tftp' firmware upgrading." ::= { sm24tat4xbSoftware 2 } sm24tat4xbSoftwareIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the firmware tftp server." ::= { sm24tat4xbSoftware 3 } sm24tat4xbSoftwareFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the path and filename for firmware upgrading." ::= { sm24tat4xbSoftware 4 } sm24tat4xbSoftwareUpgradeCmd OBJECT-TYPE SYNTAX INTEGER { noAction ( 0 ), tftpUpgrade ( 1 ), ftpUpgrade ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Firmware upgrade command. noAction(0 )- do nothing (read only). tftpUpgrade (1) - activate 'tftp' firmware upgrade" DEFVAL { noAction } ::= { sm24tat4xbSoftware 5 } sm24tat4xbSoftwareImageSelectionCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Activate firmware image selection. noAction(0) - do nothing - returned upon get. activate(1) - activate firmware image selection." DEFVAL { noAction } ::= { sm24tat4xbSoftware 6 } sm24tat4xbSaveStartCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "This copies running-config to startup-config, thereby ensuring that the currently active configuration will be used at the next reboot. " DEFVAL { noAction } ::= { sm24tat4xbConfig 1 } sm24tat4xbConfigUsername OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the username for 'tftp' 'upload config' or 'download config'." ::= { sm24tat4xbConfig 2 } sm24tat4xbConfigPassword OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the password for 'tftp' 'upload config' or 'download config'." ::= { sm24tat4xbConfig 3 } sm24tat4xbConfigIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the IP address for 'tftp' 'upload config' or 'download config'." ::= { sm24tat4xbConfig 4 } sm24tat4xbConfigFilename OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Get/Set the filename in switch for 'tftp' 'upload config' or 'download config'." ::= { sm24tat4xbConfig 5 } sm24tat4xbConfigFileTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBConfigFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The config file tabe." ::= { sm24tat4xbConfig 6 } sm24tat4xbConfigFileEntry OBJECT-TYPE SYNTAX SM24TAT4XBConfigFileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry in the config file tabe." INDEX { sm24tat4xbConfigFileIndex } ::= { sm24tat4xbConfigFileTable 1 } SM24TAT4XBConfigFileEntry ::= SEQUENCE { sm24tat4xbConfigFileIndex Integer32, sm24tat4xbShowConfigFileName DisplayString, sm24tat4xbActivateConfigCmd ActivateCmd, sm24tat4xbDeleteConfigCmd ActivateCmd, sm24tat4xbUploadConfigCmd INTEGER, sm24tat4xbDownloadConfigCmd INTEGER } sm24tat4xbConfigFileIndex OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The config file index." ::= { sm24tat4xbConfigFileEntry 1 } sm24tat4xbShowConfigFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Shows the config file name. Without config filename:'NewConfig' is temp file when 'activate download config' can 'create new file' and 'change create filename'." ::= { sm24tat4xbConfigFileEntry 2 } sm24tat4xbActivateConfigCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Activate config command. noAction(0) : do nothing (read only). activate(1) : activate the config" DEFVAL { noAction } ::= { sm24tat4xbConfigFileEntry 3 } sm24tat4xbDeleteConfigCmd OBJECT-TYPE SYNTAX ActivateCmd MAX-ACCESS read-write STATUS current DESCRIPTION "Delete config command. noAction(0) : do nothing (read only). activate(1) : delete the config" DEFVAL { noAction } ::= { sm24tat4xbConfigFileEntry 4 } sm24tat4xbDownloadConfigCmd OBJECT-TYPE SYNTAX INTEGER { noAction ( 0 ), tftpUpload ( 1 ) --ftpUpload ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Download config command. noAction (0) - do nothing (read only). tftpUpload (1) - activate 'tftp' config download." DEFVAL { noAction } ::= { sm24tat4xbConfigFileEntry 5 } sm24tat4xbUploadConfigCmd OBJECT-TYPE SYNTAX INTEGER { noAction ( 0 ), tftpDownload ( 1 ) --ftpDownload ( 2 ) } MAX-ACCESS read-write STATUS current DESCRIPTION "Upload config command. noAction (0) - do nothing (read only). tftpDownload (1) - activate 'tftp' config upload. For merge/replace running-config: 1:merge 3:replace" DEFVAL { noAction } ::= { sm24tat4xbConfigFileEntry 6 } -- ======================================================================================================================= sm24tat4xbDiagnostics OBJECT IDENTIFIER ::= { sm24tat4xbMaintenance 5 } sm24tat4xbPingIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " The destination IP Address. " ::= { sm24tat4xbDiagnostics 1 } sm24tat4xbPingSize OBJECT-TYPE SYNTAX Integer32(60..1400) MAX-ACCESS read-write STATUS current DESCRIPTION " Size of ICMP echo packet. range : 60-1400, default : 64. " ::= { sm24tat4xbDiagnostics 2 } sm24tat4xbDoPingConfig OBJECT-TYPE SYNTAX Integer32(1) MAX-ACCESS read-write STATUS current DESCRIPTION "Do ping-config. Get this OID always return zero. 1 - ping. Uses the ICMP protocol's mandatory ECHO_REQUEST datagram to elicit an ICMP ECHO_RESPONSE from a host or gateway. " ::= { sm24tat4xbDiagnostics 3 } sm24tat4xbPingResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Show ping result. " ::= { sm24tat4xbDiagnostics 4 } sm24tat4xbPing6IpAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " The destination IPv6 Address. " ::= { sm24tat4xbDiagnostics 5 } sm24tat4xbPing6Size OBJECT-TYPE SYNTAX Integer32(60..1400) MAX-ACCESS read-write STATUS current DESCRIPTION " Size of ICMP echo packet. range : 60-1400. " ::= { sm24tat4xbDiagnostics 6 } sm24tat4xbPing6EgressInterface OBJECT-TYPE SYNTAX Integer32(1..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "The VLAN ID (VID) of the specific egress IPv6 interface which ICMP packet goes." ::= { sm24tat4xbDiagnostics 7 } sm24tat4xbDoPing6Config OBJECT-TYPE SYNTAX Integer32(1) MAX-ACCESS read-write STATUS current DESCRIPTION "Do ping-config. Get this OID always return zero. 1 - ping. Uses the ICMP protocol's mandatory ECHO_REQUEST datagram to elicit an ICMP ECHO_RESPONSE from a host or gateway. " ::= { sm24tat4xbDiagnostics 8 } sm24tat4xbPing6Result OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Show ping result. " ::= { sm24tat4xbDiagnostics 9 } sm24tat4xbtracerouteIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " The destination IP Address. " ::= { sm24tat4xbDiagnostics 10 } --sm24tat4xbtracerouteProtocol OBJECT-TYPE -- SYNTAX Integer32(0..2) -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- " Specify protocol including icmp=0, udp=1 and tcp=2. -- range : 0-2, default : 0. " -- ::= { sm24tat4xbDiagnostics 11 } sm24tat4xbtracerouteWaittime OBJECT-TYPE SYNTAX Integer32(1..60) MAX-ACCESS read-write STATUS current DESCRIPTION " Specify wait time for waiting probe packets come back. range : 1-60(sec), default : 5(sec). " ::= { sm24tat4xbDiagnostics 12 } sm24tat4xbtracerouteMaxTTL OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS read-write STATUS current DESCRIPTION " Specify max TTL. range : 1-255, default : 30. " ::= { sm24tat4xbDiagnostics 13 } sm24tat4xbtracerouteNqueries OBJECT-TYPE SYNTAX Integer32(1..10) MAX-ACCESS read-write STATUS current DESCRIPTION " Specify number of probe packets. range : 1-10, default : 3. " ::= { sm24tat4xbDiagnostics 14 } sm24tat4xbDotracerouteConfig OBJECT-TYPE SYNTAX Integer32(1) MAX-ACCESS read-write STATUS current DESCRIPTION "Do traceroute-config. Get this OID always return zero. 1 - ping. Uses the traceroute program to get ip address of the middle gateway. " ::= { sm24tat4xbDiagnostics 15 } sm24tat4xbtracerouteResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Show traceroute result. " ::= { sm24tat4xbDiagnostics 16 } sm24tat4xbCableDiagnostics OBJECT IDENTIFIER ::= { sm24tat4xbDiagnostics 17 } sm24tat4xbCableDiagnosticsTest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Run Cable Diagnostics. port, range : 1 - port number." ::= { sm24tat4xbCableDiagnostics 1 } sm24tat4xbCableDiagnosticsTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBCableDiagnosticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { sm24tat4xbCableDiagnostics 2 } sm24tat4xbCableDiagnosticsEntry OBJECT-TYPE SYNTAX SM24TAT4XBCableDiagnosticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbCableDiagnosticsPort } ::= { sm24tat4xbCableDiagnosticsTable 1 } SM24TAT4XBCableDiagnosticsEntry ::= SEQUENCE { sm24tat4xbCableDiagnosticsPort Integer32, sm24tat4xbCableDiagnosticsLinkStatus DisplayString, sm24tat4xbCableDiagnosticsTestResult DisplayString, sm24tat4xbCableDiagnosticsLength DisplayString } sm24tat4xbCableDiagnosticsPort OBJECT-TYPE SYNTAX Integer32(1..65535) MAX-ACCESS not-accessible STATUS current DESCRIPTION "port index" ::= { sm24tat4xbCableDiagnosticsEntry 1 } sm24tat4xbCableDiagnosticsLinkStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the cable." ::= { sm24tat4xbCableDiagnosticsEntry 2 } sm24tat4xbCableDiagnosticsTestResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Test Result of the cable." ::= { sm24tat4xbCableDiagnosticsEntry 3 } sm24tat4xbCableDiagnosticsLength OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The length (in meters) of the cable." ::= { sm24tat4xbCableDiagnosticsEntry 4 } sm24tat4xbSwitchRebootSchedule OBJECT IDENTIFIER ::= { sm24tat4xbMaintenance 6 } sm24tat4xbSwitchRebootMode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Switch Reboot Mode. 0:disable 1:enable" ::= { sm24tat4xbSwitchRebootSchedule 1 } sm24tat4xbSwitchRebootTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF SM24TAT4XBSwitchRebootTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Configure the Switch reboot time. " ::= { sm24tat4xbSwitchRebootSchedule 2 } sm24tat4xbSwitchRebootTimeEntry OBJECT-TYPE SYNTAX SM24TAT4XBSwitchRebootTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { sm24tat4xbSwitchRebootWeekIndex } ::= { sm24tat4xbSwitchRebootTimeTable 1 } SM24TAT4XBSwitchRebootTimeEntry ::= SEQUENCE { sm24tat4xbSwitchRebootWeekIndex Integer32, sm24tat4xbSwitchRebootTimeHour Integer32, sm24tat4xbSwitchRebootTimeMinute Integer32 } sm24tat4xbSwitchRebootWeekIndex OBJECT-TYPE SYNTAX Integer32 (1..7) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch reboot week index. 1: Sun, 2: Mon, 3:Tue, 4: Wed, 5: Thu, 6: Fri, 7: Sat" ::= { sm24tat4xbSwitchRebootTimeEntry 1 } sm24tat4xbSwitchRebootTimeHour OBJECT-TYPE SYNTAX Integer32 (-1..23) MAX-ACCESS read-write STATUS current DESCRIPTION "Switch Reboot Time (Hour). Range: 0-23. -1:disable" ::= { sm24tat4xbSwitchRebootTimeEntry 2 } sm24tat4xbSwitchRebootTimeMinute OBJECT-TYPE SYNTAX Integer32 (-1..55) MAX-ACCESS read-write STATUS current DESCRIPTION "Switch Reboot Time (Minute). Range:0,5,10,...,55. -1:disable" ::= { sm24tat4xbSwitchRebootTimeEntry 3 } sm24tat4xbiPerf OBJECT IDENTIFIER ::= { sm24tat4xbMaintenance 7 } sm24tat4xbiPerfMethod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The measuring method of iPerf. 2:iPerf version 2 3:iPerf version 3" ::= { sm24tat4xbiPerf 2 } sm24tat4xbiPerfHost OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The address of iPerf server. " ::= { sm24tat4xbiPerf 3 } sm24tat4xbiPerfPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The listen port of iPerf server. The default value is 5001 for iPerf, 5201 for iPerf3. " ::= { sm24tat4xbiPerf 4 } sm24tat4xbiPerfTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds to transmit for (default 10 secs). " ::= { sm24tat4xbiPerf 5 } sm24tat4xbiPerfInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds between periodic bandwidth reports (default no periodic reports). " ::= { sm24tat4xbiPerf 6 } sm24tat4xbiPerfTTL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The time-to-live, for multicast (default 1). " ::= { sm24tat4xbiPerf 7 } sm24tat4xbiPerfStart OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Start iPerf 1:Start." ::= { sm24tat4xbiPerf 8 } sm24tat4xbiPerfResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Test result of iPerf" ::= { sm24tat4xbiPerf 9 } -- ======================================================================================================================= sm24tat4xbTrap OBJECT IDENTIFIER ::= { sm24tat4xbProductId 5 } sm24tat4xbTrapEvent OBJECT IDENTIFIER ::= { sm24tat4xbTrap 1 } sm24tat4xbEmergency NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Emergency. Emergency conditions." ::= { sm24tat4xbTrapEvent 1 } sm24tat4xbAlert NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Alert. Alert conditions." ::= { sm24tat4xbTrapEvent 2 } sm24tat4xbCritical NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Critical. Critical conditions." ::= { sm24tat4xbTrapEvent 3 } sm24tat4xbError NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Error. Error conditions." ::= { sm24tat4xbTrapEvent 4 } sm24tat4xbWarning NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Warning. Warning conditions." ::= { sm24tat4xbTrapEvent 5 } sm24tat4xbNotice NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Notice. Notice conditions." ::= { sm24tat4xbTrapEvent 6 } sm24tat4xbInformational NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Informational. Informational conditions." ::= { sm24tat4xbTrapEvent 7 } sm24tat4xbDebug NOTIFICATION-TYPE OBJECTS { sm24tat4xbInformation } STATUS current DESCRIPTION "The severity level is Debug. Debug conditions." ::= { sm24tat4xbTrapEvent 8 } sm24tat4xbTrapVariable OBJECT IDENTIFIER ::= { sm24tat4xbTrap 2 } sm24tat4xbInformation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Trap information." ::= { sm24tat4xbTrapVariable 1 } sm24tat4xbZTPTrap OBJECT IDENTIFIER ::= { sm24tat4xbTrap 3 } sm24tat4xbZTPTrapEvent OBJECT IDENTIFIER ::= { sm24tat4xbZTPTrap 0 } sm24tat4xbZTPOnboardTrap NOTIFICATION-TYPE OBJECTS { sysObjectID, sm24tat4xbSnmpSystemVersion, sm24tat4xbSnmpSystemReadCommunity, sm24tat4xbSnmpSystemWriteCommunity, sm24tat4xbSystemInfoSeriesNumber, sm24tat4xbSystemInfoHostMACAddress, sm24tat4xbIPInterfacesIPv4Address } STATUS current DESCRIPTION "The switch information." ::= { sm24tat4xbZTPTrapEvent 1 } END